1.
As one of the alternatives to traditional metal-on-polyethylene total hip replacements, metal-on-metal hip resurfacing prostheses demonstrating lower wear have been introduced for younger and more active patients during the past decade. However, in vitro hip simulator testing for the predicted increased lifetime of these surface replacements is time-consuming and costly. Computational wear modelling based on the Archard wear equation and finite element contact analysis was developed in this study for artificial hip joints and particularly applied to metal-on-metal resurfacing bearings under simulator testing conditions to address this issue. Wear factors associated with the Archard wear equation were experimentally determined and based on the short-term hip simulator wear results. The computational wear simulation was further extended to a long-term evaluation up to 50 million cycles assuming that the wear rate stays constant. The prediction from the computational model shows good agreement with the corresponding simulator study in terms of volumetric wear and the wear geometry. The simulation shows the progression of linear wear penetrations, and the complexity of contact stress distribution on the worn bearing surfaces. After 50 million cycles, the maximum linear wear was predicted to be approximately 6 and 8 microm for the cup and head, respectively, and no edge contact was found.  相似文献   

2.
Using the combination ceramic on ceramic for hip prostheses, the wear rate can be reduced to less than 1 micron per million cycles. More than 20 years of experience are now available for various concepts involving alumina ceramics in THR. In the early days, monolithic ceramic cups were employed. However, since alumina ceramic has an unsatisfactory potential for bone integration, soft tissue forms at the interface, with the result that the sockets migrate and penetrate. To improve bony integration, monoblock cups surfaced with ceramic beads were introduced. For the past 10 years, there has been a trend towards the use of modular acetabular components comprising a metal shell and a liner made of Biolox forte ceramic. Two concepts for the fixation of the ceramic liners are employed: locking of the ceramic in the metal shell (CeraLock) and the sandwich concept with a polyethylene layer interposed between liner and shell. The basic design and important aspects such as diameter, range of motion, and the possibility for revision, clinical experience, and trends are discussed.  相似文献   

3.
Bone morphology and density changes are commonly observed following joint replacement, may contribute to the risks of implant loosening and periprosthetic fracture and reduce the available bone stock for revision surgery. This study was presented in the ‘Bone and Cartilage Mechanobiology across the scales’ WCCM symposium to review the development of remodelling prediction methods and to demonstrate simulation of adaptive bone remodelling around hip replacement femoral components, incorporating intrinsic (prosthesis) and extrinsic (activity and loading) factors. An iterative bone remodelling process was applied to finite element models of a femur implanted with a cementless total hip replacement (THR) and a hip resurfacing implant. Previously developed for a cemented THR implant, this modified process enabled the influence of pre- to post-operative changes in patient activity and joint loading to be evaluated. A control algorithm used identical pre- and post-operative conditions, and the predicted extents and temporal trends of remodelling were measured by generating virtual X-rays and DXA scans. The modified process improved qualitative and quantitative remodelling predictions for both the cementless THR and resurfacing implants, but demonstrated the sensitivity to DXA scan region definition and appropriate implant–bone position and sizing. Predicted remodelling in the intact femur in response to changed activity and loading demonstrated that in this simplified model, although the influence of the extrinsic effects were important, the mechanics of implantation were dominant. This study supports the application of predictive bone remodelling as one element in the range of physical and computational studies, which should be conducted in the preclinical evaluation of new prostheses.  相似文献   

4.
A lack of initial stability of the fixation is associated with aseptic loosening of the tibial components of cementless knee prostheses. With sufficient stability after surgery, minimal relative motion between the prosthesis and bone interfaces allows osseointegation to occur thereby providing a strong prosthesis-to-bone biological attachment. Finite element modelling was used to investigate the bone–prosthesis interface micromotion and the relative risk of aseptic loosening. It was anticipated that by prescribing different joint loads representing gait and other activities, and the consideration of varying tibial–femoral contact points during knee flexion, it would influence the computational prediction of the interface micromotion. In this study, three-dimensional finite element models were set up with applied loads representing walking and stair climbing, and the relative micromotions were predicted. These results were correlated to in-vitro measurements and to the results of prior retrieval studies. Two load conditions, (i) a generic vertical joint load of 3×body weight with 70%/30% M/L load share and antero-posterior/medial-lateral shear forces, acted at the centres of the medial and lateral compartments of the tibial tray, and (ii) a peak vertical joint load at 25% of the stair climbing cycle with corresponding antero-posterior shear force applied at the tibial–femoral contact points of the specific knee flexion angle, were found to generate interface micromotion responses which corresponded to in-vivo observations. The study also found that different loads altered the interface micromotion predicted, so caution is needed when comparing the fixation performance of various reported cementless tibial prosthetic designs if each design was evaluated with a different loading condition.  相似文献   

5.
Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface.  相似文献   

6.
Ceramic hip resurfacing may offer improved wear resistance compared to metallic components. The study is aimed at investigating the effects of stiffer ceramic components on the stress/strain-related failure mechanisms in the resurfaced femur, using three-dimensional finite element models of intact and resurfaced femurs with varying stem–bone interface conditions. Tensile stresses in the cement varied between 1 and 5 MPa. Postoperatively, 20–85% strain shielding was observed inside the resurfaced head. The variability in stem–bone interface condition strongly influenced the stresses and strains generated within the resurfaced femoral head. For full stem–bone contact, high tensile (151–158 MPa) stresses were generated at the cup–stem junction, indicating risk of fracture. Moreover, there was risk of femoral neck fracture due to elevated bone strains (0.60–0.80% strain) in the proximal femoral neck region. Stresses in the ceramic component are reduced if a frictionless gap condition exists at the stem–bone interface. High stresses, coupled with increased strain shielding in the ceramic resurfaced femur, appear to be major concerns regarding its use as an alternative material.  相似文献   

7.
The effect of a short-stem femoral resurfacing component on load transfer and potential failure mechanisms has rarely been studied. The stem length has been reduced by approximately 50% as compared to the current long-stem design. Using 3-D FE models of natural and resurfaced femurs, the study is aimed at investigating the influence of a short-stem resurfacing component on load transfer and bone remodelling. Applied loading conditions include normal walking and stair climbing. The mechanical role of the stem along with implant–cement and stem–bone contact conditions was observed to be crucial. Shortening the stem length to half of the current length (long-stem) led to several favourable effects, even though the stress distributions in the implant and the cement were similar in both the cases. The short-stem implant led not only to a more physiological stress distribution but also to bone apposition (increase of 20–70% bone density) in the superior resurfaced head, when the stem–bone contact prevailed. This also led to a reduction in strain concentration in the cancellous bone around the femoral neck–component junction. The normalised peak strain in this region was lower for the short-stem design as compared to that of the long-stem one, thereby reducing the initial risk of neck fracture. The effect of strain shielding (50–75% reduction) was restricted to a small bone volume underlying the cement, which was approximately half of that of the long-stem design. Consequently, bone resorption was considerably less for the short-stem design. The short-stem design offers better prospects than the long-stem resurfacing component.  相似文献   

8.
Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR). A three-dimensional finite element model was developed based on a modular MoP bearing. Different cup inclination angles and head lateral microseparation were modelled and their effect on the contact mechanics of the modular MoP hip replacement were examined. The results showed that lateral microseparation caused loading of the head on the rim of the cup, which produced substantial increases in the maximum von Mises stress in the polyethylene liner and the maximum contact pressure on both the articulating surface and backside surface of the liner. Plastic deformation of the liner was observed under both standard conditions and microseparation conditions, however, the maximum equivalent plastic strain in the liner under microseparation conditions of 2000 µm was predicted to be approximately six times that under standard conditions. The study has indicated that correct positioning the components to avoid edge loading is likely to be important clinically even for hard-on-soft bearings for THR.  相似文献   

9.
10.
Failure of total knee arthroplasty is relatively often caused by problems of the patellofemoral replacement. The purpose of this study was to analyze the distribution of stresses within an anatomical patella and the changes in stress distribution after patellar resurfacing with a Miller-Galante I patellar implant using two- and three dimensional finite element models (FEM). To assess validity, FEM results were compared with morphological findings from contact radiographs and densitographs. Internal orientation of bone trabeculae is in good agreement with the orientation of theoretically calculated principal stresses. Almost unchanged principal tensile stresses after implantation, together with the lack of extreme stress peaks within the cancellous bone ensure stress compatibility of the implant. In the case of a firmly seated implant with good bone ingrowth, increased von Mises stresses are found near the fixation peg/plate junction. Their relevance for improved bone ingrowth near this part of the interface is emphasized. At the same time, material failure at the peg/plate junction can be better understood. An analysis of the early postoperative period assuming nonlinear interface conditions failed to demonstrate an uniform distribution of normal and tangential interface forces.  相似文献   

11.
Abstract

One of the major causes of implant loosening is due to excessive bone resorption surrounding the implant due to bone remodelling. The objective of the study is to investigate the effects of implant material and implant–bone interface conditions on bone remodelling around tibia bone due to total ankle replacement. Finite element models of intact and implanted ankles were developed using CT scan data sets. Bone remodelling algorithm was used in combination with FE analysis to predict the bone density changes around the ankle joint. Dorsiflexion, neutral, and plantar flexion positions were considered, along with muscle force and ligaments. Implant–bone interfacial conditions were assumed as debonded and bonded to represent non-osseointegration and fully osseointegration at the porous coated surface of the implant. To investigate the effect of implant material, three finite element models having different material combinations of the implant were developed. For model 1, tibial and talar components were made of Co–Cr–Mo, and meniscal bearing was made of UHMWPE. For model 2, tibial and talar components were made of ceramic and meniscal bearing was made of UHMWPE. For model 3, tibial and talar components were made of ceramic and meniscal bearing was made of CFR-PEEK. Changes in implant material showed no significant changes in bone density due to bone remodelling. Therefore, ceramic appears to be a viable alternative to metal and CFR-PEEK can be used in place of UHMWPE. This study also indicates that proper bonding between implant and bone is essential for long-term survival of the prosthetic components.  相似文献   

12.
Glenoid prosthesis loosening is the most common cause for revision total shoulder arthroplasty. Stress-induced bone remodeling may compromise long-term prosthesis fixation and significantly contribute to loosening. Realistic, robust analysis of bone-prosthesis constructs need to look beyond initial post-implantation mechanics provided by static finite element (FE) simulation. Adaptive bone remodeling simulations based on Wolff's law are needed for evaluating long-term glenoid prostheses fixation. The purpose of this study was to take a first step towards this goal and create and validate two-dimensional FE simulations, using the intact glenoid, for computing subject-specific adaptive glenoid remodeling. Two-dimensional glenoid FE models were created from scapulae computed tomography images. Two distinct processes, “element” and “node” simulations, used the forward-Euler method to compute bone remodeling. Initial bone density was homogeneous. Center and offset load combinations were iteratively applied. To validate the simulations we performed location-specific statistical comparisons between predicted and actual bone density, load combinations, and “element” and “node” processes. Visually and quantitatively “element” simulations produced better results (p>0.22), and correlation coefficients ranged 0.51–0.69 (p<0.001). Having met this initial work's goals, we expect subject-specific FE glenoid bone remodeling simulations together with static FE stress analyses to be effective tools for designing and evaluating glenoid prostheses.  相似文献   

13.
Hip implants heat up due to friction during long lasting, high loading activities like walking. Thermal damage in the surrounding soft and hard tissues and deteriorated lubrication of synovial fluid could contribute to implant loosening. The goal of this study was to determine the implant temperatures in vivo under varying conditions. Temperatures and contact forces in the joints were measured in seven joints of five patients using instrumented prostheses with alumina ceramic heads and telemetry data transmission. The peak temperature in implants with polyethylene cups rose up to 43.1 degrees C after an hour of walking but varied considerably individually. Even higher temperatures at the joints are probable for patients with higher body weight or while jogging. The peak temperature was lower with a ceramic cup, showing the influence of friction in the joint. During cycling the peak temperatures were lower than during walking, proving the effect of force magnitudes on the produced heat. However, no positive correlation was found between force magnitude and maximum temperature during walking. Other individual parameters than just the joint force influence the implant temperatures. Based on the obtained data and the available literature about thermal damage of biological tissues a detrimental effect of friction induced heat on the stability of hip implants cannot be excluded. Because the potential risk for an individual patient cannot be foreseen, the use and improvement of low friction implant materials is important.  相似文献   

14.
Conventional bone plates are commonly used for surgical mandibular fracture fixation. Improper alignment between bone segments, however, can result in malocclusion. Current methods of fixation require a surgeon to visually align segments of bone and affix a metal plate using bone screws, after which little can be done to adjust alignment. A method of adjusting fracture alignment after plate placement, without screw removal, presents an improvement over costly and risky revision surgery. A modified bone plate has been designed with a deformable section to give surgeons the ability to reduce misalignments at the fracture site. The mechanics of deformation for various adjustment mechanisms was explored analytically, numerically, and experimentally to ensure that the adjustable plate is comparable to conventional bone plates. A static force of 358.8 N is required to deform the adjustable bone plate, compared with predicted values of 351 N using numerical simulation and 362 N using a simple beam theory. Dynamic testing was performed to simulate in vivo loading conditions and evaluate load-capacity in both deformed and un-deformed bone plates. Results indicate that bending stiffness of a rectangular bone plate is 709 N/mm, compared with 174 N/mm for an octagonal plate and 176 N/mm for standard plates. Once deformed, the rectangular and octagonal plates had a stiffness of 323 N/mm and 228 N/mm, respectively. Un-deformed and deformed adjustable bone plates have efficacy in bone segment fixation and healing.  相似文献   

15.
Abstract

Finite element modeling (FEM) can predict hip cartilage contact mechanics. This study investigated how subject-specific boundary conditions and joint geometry affect acetabular cartilage contact mechanics using a multi-scale workflow. For two healthy subjects, musculoskeletal models calculated subject-specific hip kinematics and loading, which were used as boundary conditions for FEM. Cartilage contact mechanics were predicted using either generic or subject-specific FEM and boundary conditions. A subject-specific mesh resulted in a more lateral contact. Effects of subject-specific boundary conditions varied between both subjects. Results highlight the complex interplay between loading and kinematics and their effect on cartilage contact mechanics.  相似文献   

16.
Wear of the central bushing made of ultra-high molecular weight polyethylene (PE-UHMW) of the hinged knee endoprosthesis of a tumour-resection system is the leading reason for revision. The aim of the study was to optimize the wear characteristics of the endoprosthesis on the basis of the tribological properties of new materials and an additional finite element (FE) calculation taking account of the given design. In screening tests the reference combination of PE-UHMW bushing and CoCr axis--used in the clinical setting--was first tested. The PE-UHMW bushing was then replaced by one made of each of the materials reinforced high-density polyethylene (PE-HD) and carbon fibre-reinforced epoxy resin (CFRP). In addition, a new material combination with an alumina ceramic bushing and a CFRP axis was investigated. In comparison with the reference combination PE-UHMW/metal, the combination of ceramic bushing and CFRP axis showed less wear. However, with the particular design of the prosthesis studied here, high mechanical loading applied experimentally resulted in mechanical failure. FE calculations confirmed these experimental results. Improvement of the wear characteristics of this specific implant caused therefore be achieved only by optimizing the bearing design.  相似文献   

17.
Loosening and migration of tibial prostheses have been identified as causes of early total knee replacement (TKR) failure. The problem is made more complex when defects occur in the proximal tibia compromising fixation and alignment. Clinical studies using metal augments have shown these to be an alternative to other means of defect treatment. Finite element (FE) analysis can be used to identify regions that may be prone to loosening and migration. In the current work, 3D FE models of TKR uncontained type-2 defects treated with block augments have been constructed and analysed. It has been shown that a metal augment is the most suitable. The use of bone cement (PMMA) to fill proximal defects is not considered suitable as stresses carried by the cement block exceed those of the fatigue limit of bone cement. It has been shown that the stresses in the proximal cancellous bone of block-augmented models are significantly below levels likely to cause damage due to overloading. Furthermore, the use of stem extensions has been shown to reduce the cancellous bone stresses in the proximal region thus increasing the likelihood of bone resorption. Given this, it is recommended that stem extensions are not required unless necessary to mitigate some other problem.  相似文献   

18.
Computational models may have the ability to quantify the relationship between hip morphology, cartilage mechanics and osteoarthritis. Most models have assumed the hip joint to be a perfect ball and socket joint and have neglected deformation at the bone-cartilage interface. The objective of this study was to analyze finite element (FE) models of hip cartilage mechanics with varying degrees of simplified geometry and a model with a rigid bone material assumption to elucidate the effects on predictions of cartilage stress. A previously validated subject-specific FE model of a cadaveric hip joint was used as the basis for the models. Geometry for the bone-cartilage interface was either: (1) subject-specific (i.e. irregular), (2) spherical, or (3) a rotational conchoid. Cartilage was assigned either a varying (irregular) or constant thickness (smoothed). Loading conditions simulated walking, stair-climbing and descending stairs. FE predictions of contact stress for the simplified models were compared with predictions from the subject-specific model. Both spheres and conchoids provided a good approximation of native hip joint geometry (average fitting error ~0.5 mm). However, models with spherical/conchoid bone geometry and smoothed articulating cartilage surfaces grossly underestimated peak and average contact pressures (50% and 25% lower, respectively) and overestimated contact area when compared to the subject-specific FE model. Models incorporating subject-specific bone geometry with smoothed articulating cartilage also underestimated pressures and predicted evenly distributed patterns of contact. The model with rigid bones predicted much higher pressures than the subject-specific model with deformable bones. The results demonstrate that simplifications to the geometry of the bone-cartilage interface, cartilage surface and bone material properties can have a dramatic effect on the predicted magnitude and distribution of cartilage contact pressures in the hip joint.  相似文献   

19.
This study sought to develop a computational framework that emulates the anterior cruciate ligament reconstruction surgery using transtibial portal technique. The proposed model included the tibia–femoral and patella–femoral joints, articular cartilage and menisci. Key surgical parameters were incorporated including bone-patellar-tendon-bone graft excision and pre-tensioning, tunnel morphology, bone plugs, and bone plug fixation. Several simulation steps were parameterized to reflect the clinically reported surgical procedure. Our focus was to explore the intra-operative effects of variations in tunnel directions on the selected metrics of joint mechanics during Lachman and Anterior Drawer tests. A mathematical construct capable of transforming the limited and heterogeneous experimental and surgical data to evidence-based validation was adopted to ensure the viability of the finite element models. We found that the proposed models, subject to a variation in tunnel directions, resulted in simulation outputs that favor the reported experimental data of Lachman and Anterior Drawer tests under uncertainty. Simulation results for a population of three-dimensional tunnel orientations provided insights into the graft–tunnel contact mechanics and the spatial stress distribution in the graft, insights that have been anecdotally observed in prior experimental studies. The intraarticular graft tension was found to be higher than the estimated in tunnel graft force, and larger differences were found for the least inclined tunnels exhibiting higher contact pressures, transverse bending and twisting of the graft and Von-Mises stress at the graft–femoral tunnel interface. Conversely, tunnels with high inclination angles exhibited higher intraarticular graft tension and Von-Mises stress at the graft–tibial bone plug interface.  相似文献   

20.
Patellar resurfacing during knee replacement is still under debate, with several studies reporting higher incidence of anterior knee pain in unresurfaced patellae. Congruency between patella and femur impacts the mechanics of the patellar cartilage and strain in the underlying bone, with higher stresses and strains potentially contributing to cartilage wear and anterior knee pain. The material properties of the articulating surfaces will also affect load transfer between femur and patella. The purpose of this study was to evaluate the mechanics of the unresurfaced patella and compare with natural and resurfaced conditions in a series of finite element models of the patellofemoral joint. In the unresurfaced analyses, three commercially available implants were compared, in addition to an 'ideal' femoral component which replicated the geometry, but not the material properties, of the natural femur. Hence, the contribution of femoral component material properties could be assessed independently from geometry changes. The ideal component tracked the kinematics and patellar bone strain of the natural knee, but had consistently inferior contact mechanics. In later flexion, compressive patellar bone strain in unresurfaced conditions was substantially higher than in resurfaced conditions. Understanding how femoral component geometry and material properties in unresurfaced knee replacement alters cartilage contact mechanics and bone strain may aid in explaining why the incidence of anterior knee pain is higher in the unresurfaced population, and ultimately contribute to identifying criteria to pre-operatively predict which patients are suited to an unresurfaced procedure and reducing the incidence of anterior knee pain in the unresurfaced patient population.  相似文献   