首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method operated in the positive/negative electrospray ionization (ESI) switching mode has been developed and validated for the simultaneous determination of asperosaponin VI and its active metabolite hederagenin in rat plasma. After addition of internal standards diazepam (for asperosaponin VI) and glycyrrhetic acid (for hederagenin), the plasma sample was deproteinized with acetonitrile, and separated on a reversed phase C18 column with a mobile phase of methanol (solvent A)-0.05% glacial acetic acid containing 10 mM ammonium acetate and 30 μM sodium acetate (solvent B) using gradient elution. The detection of target compounds was done in multiple reaction monitoring (MRM) mode using a tandem mass spectrometry equipped with positive/negative ion-switching ESI source. At the first segment, the MRM detection was operated in the positive ESI mode using the transitions of m/z 951.5 ([M+Na](+))→347.1 for asperosaponin VI and m/z 285.1 ([M+H](+))→193.1 for diazepam for 4 min, then switched to the negative ESI mode using the transitions of m/z 471.3 ([M-H](-))→471.3 for hederagenin and m/z 469.4 ([M-H](-))→425.4 for glycyrrhetic acid, respectively. The sodiated molecular ion [M+Na](+) at m/z 951.5 was selected as the precursor ion for asperosaponin VI, since it provided better sensitivity compared to the deprotonated and protonated molecular ions. Sodium acetate was added to the mobile phase to make sure that abundant amount of the sodiated molecular ion of asperosaponin VI could be produced, and more stable and intensive mass response of the product ion could be obtained. For the detection of hederagenin, since all of the mass responses of the fragment ions were very weak, the deprotonated molecular ion [M-H](-)m/z 471.3 was employed as both the precursor ion and the product ion. But the collision energy was still used for the MRM, in order to eliminate the influences induced by the interference substances from the rat plasma. The validated method was successfully applied to study the pharmacokinetics of asperosaponin VI and its active metabolite hederagenin in rat plasma after oral administration of asperosaponin VI at a dose of 90 mg/kg.  相似文献   

2.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

3.
To support pharmacokinetic studies of ginsenosides, a novel method to quantitatively analyze ginsenoside Rg3 (Rg3), its prosapogenin ginsenoside Rh2 (Rh2) and aglycone 20(S)-protopanaxadiol (ppd) in rat plasma was developed and validated. The method was based on gradient separation of ginsenosides present in rat plasma using high performance liquid chromatography (HPLC), followed by detection with electrospray ionization(ESI) mass spectrometry (MS) in negative ion mode with the mobile phase additive, ammonium chloride (500 microM). Differentiation of ginsenosides was achieved through simultaneous detection of the [M(+)Cl(-)] adduct of ginsenoside Rg3 and [M(+)Cl(-)] adducts of its deglycosylated metabolites Rh2 and ppd, and other ions after solid phase extraction (SPE). The /specific ions monitored were m/z 819.50 for Rg3, m/z 657.35 for Rh2, m/z 495.40 for ppd and m/z 799.55 for the internal standard (digitoxin). The mean recoveries for Rg3, Rh2 and ppd were 77.85, 82.65 and 98.33%, respectively using 0.1 ml plasma for extraction. The lower limits of quantification were 10.0, 2.0 and 8.0 ng/ml (equivalent to 0.1, 0.02 and 0.08 ng in each 10 microl injection onto the HPLC column) for Rg3, Rh2 and ppd, respectively. The method has been demonstrated to be highly sensitive and accurate for the determination of Rg3 and its metabolites in rat plasma.  相似文献   

4.
A sensitive and selective liquid chromatographic method coupled with mass spectrometry (LC-MS) was developed for the quantification of phloroglucinol in human plasma. Resorcinol was used as internal standard, with plasma samples extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase. The reconstituted samples were injected into a C(18) XTerra MS column (2.1 x 100 mm) with 3.5-microm particle size. The analytical column lasted for at least 500 injections. The mobile phase was 15% acetonitrile (pH 3.0), with flow-rate at 200 microl/min. The mass spectrometer was operated in negative ion mode with selective ion monitoring (SIM). Phloroglucinol was detected without severe interferences from plasma matrix when used negative ion mode. Phloroglucinol produced a parent molecule ([M-H](-)) at m/z 125 in negative ion mode. Detection of phloroglucinol in human plasma was accurate and precise, with quantification limit at 5 ng/ml. This method has been successfully applied to a study of phloroglucinol in human specimens.  相似文献   

5.
A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was established for the determination of 5-aminoimidazole-4-carboxamide (AICA) in human plasma. The method included a solvent extraction of AICA as an ion pair with 1-pentanesulfonate ion and a separation on a Hypersil ODS2 column with the mobile phase of methanol-water (68:32, v/v). Determination was performed using an electrospray ionization source in positive ion mode (ESI(+)). Multiple reaction monitoring (MRM) was utilized for the detection monitoring m/z at 127-->110 for AICA, and 172-->128 for IS. The calibration curve was linear within a range from 20 to 2000 ng/mL and the limit of quantity for AICA in plasma was 20 ng/mL. RSD of intra-assay and inter-assay were no more than 5.90% and 5.65%.  相似文献   

6.
Prostaglandin (PG) D(2) ethanolamide (prostamide D(2)) was reduced to 9alpha,11beta-PGF(2) ethanolamide (9alpha,11beta-prostamide F(2)) by PGF synthase, which also catalyzes the reduction of PGH(2) and PGD(2) to PGF(2alpha) and 9alpha,11beta-PGF(2), respectively. These enzyme activities were measured by a new method, the liquid chromatographic-electrospray ionization-mass spectrometry (LC/ESI/MS) technique, which could simultaneously detect the substrate and all products. PGF(2alpha), 9alpha,11beta-PGF(2), PGD(2), PGH(2), 9alpha,11beta-prostamide F(2), and prostamide D(2) were separated on a TSKgel ODS 80Ts column, ionized by electrospray, and detected in the negative mode. Selected ion monitoring (SIM) of m/z 353 ([M-H](-)), 353 ([M-H](-)), 351 ([M-H](-)), 333 ([M-H-H(2)O](-)), 456 ([M+59](-)), and m/z 358 ([M-37](-)) was used for quantifying PGF(2alpha), 9alpha,11beta-PGF(2), PGD(2), PGH(2), 9alpha,11beta-prostamide F(2), and prostamide D(2), respectively. The detection limit for PGF(2alpha) and 9alpha,11beta-PGF(2) was 0.01pmol; that for PGH(2) and PGD(2), 0.1pmol; and that for prostamide D(2) and 9alpha,11beta-prostamide F(2), 0.5 and 0.03pmol, respectively. The LC/ESI/MS technique for measuring PGF synthase activity showed higher sensitivity than other methods. Using this method, we found that Bimatoprost, the ethyl amide analog of 17-phenyl-trinor PGF(2alpha) and an anti-glaucoma agent, inhibited all three reductase activities of PGF synthase when used at a low concentration. These results suggest that Bimatoprost also behaves as a potent PGF synthase inhibitor in addition to having prostamide-like activity.  相似文献   

7.
We applied the improved sensitivity and soft ionization characteristics of electrospray Ionization (ESI)-MS/MS and matrix-assisted laser desorption/ionization(MALDI)-time of flight (TOF) mass spectrometry (MS) to analysis of the GPI-anchored C-terminal peptide derived from 5'-nucleotidase. ESI-MS/MS analysis was applied to the core structure (MW, 2,743). In the collision-induced dissociation (CID) spectrum, single-charged ions such as m/z 162 (glucosamine), 286 (mannose-phosphate-ethanolamine), and 447 ([mannose-phosphate-ethanolamine]-glucosamine) were clearly detected as characteristic fragment ions of the GPI-anchored peptide. On MALDI-TOF-MS analysis, heterogeneous peaks of GPI-anchored peptides were detected as single-charged ions in the positive mode. Product ions were obtained by post-source decay (PSD) of m/z 2,905 using curved field reflectron of TOF-MS. Most of the expected product ions derived from the GPI-anchored peptide, containing the core structure and an additional mannose side chain, were successively obtained. Thus, ESI-MS/MS and MALDI-TOF-PSD-MS proved to be effective and sensitive methods for analyzing the GPI-anchored peptide structure with less than 10 pmol of sample. These characteristic fragments or fragmentation patterns seem to be very useful for identification of GPI-anchored C-terminal peptides derived from any kind of GPI-anchored protein.  相似文献   

8.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers.  相似文献   

9.
A method for quantifying two toxic glycoalkaloids, alpha-solanine and alpha-chaconine, in potato (Solanum tuberosum) tuber tissue was developed using HPLC-electrospray ionisation (ESI)/MS. Potato samples were extracted with 5% aqueous acetic acid, and the extracts were subjected directly to HPLC-ESI/MS after filtration. By determining the intensities of the protonated molecules of alpha-solanine (m/z 868) and alpha-chaconine (m/z 852) using selected ion monitoring (positive ion mode), a sensitive assay was attained with detection limits of 38 and 14 ppb for the two glycoalkaloids, respectively. The high sensitivity and selectivity of MS detection effectively reduced the time of analysis thus enabling a high throughput assay of glycoalkaloids in potato tubers.  相似文献   

10.
A sensitive, specific and reproducible method for the quantitative determination of kavain in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride. The hair sample (about 50 mg) was incubated in 1 ml of methanol for 1 h, in an ultrasonic bath, in presence of 20 ng of methaqualone-d7 used as internal standard. The methanolic solution was evaporated to dryness, and the residue reconstituted by adding 30 microl of methanol. A 2 microl aliquot of the extract was injected onto the column (Optima5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.25 mm i.d. x 0.25 mm film thickness) of a Hewlett-Packard (Palo Alto, CA) gas chromatograph (5890). Kavain was detected by its parent ion at m/z 230 and daughter ions at m/z 111 and 202 through a Finnigan TSQ 700 MS/MS system. The assay was capable of detecting 30 pg/mg of kavain (limit of detection (LOD)). Linearity was observed for kavain concentrations ranging from 100 to 2000 pg/mg with a correlation coefficient of 0.998. Intra-day precision at 400 pg/mg was 13.7%. The analysis of a segment of hair, obtained from an occasional consumer, revealed the presence of kavain at the concentration of 418 pg/mg. A higher concentration (1708 pg/mg) was detected in the corresponding pubic hair.  相似文献   

11.
A simple, sensitive and specific liquid chromatography coupled electrospray ionization mass spectrometric (LC/ESI/MS) method for the determination of 13-O-demethylated metabolite (MI), one of the major metabolites of tacrolimus has been developed. The assay uses 32-demethoxyrapamycin (IS) as the internal standard; ethyl acetate as extraction solvent; a Hypersil-Keystone Beta Basic-18 reversed-phase column; and a gradient mobile phase of consisting 0.1% formic acid in water and methanol-acetonitrile (3:49, v/v). Mass detection is performed on a single quadrupole mass spectrometer equipped with an electrospray ionization (ESI) interface and operated in a positive ionization mode. MI in the microsomal incubates was quantitated by computing the peak area ratio (MI/IS) analyzed in single ion monitoring (SIM) mode (m/z: 804 and m/z: 901 for MI and IS, respectively). Precision of the assay was determined by calculating the intra-run and inter-run variation at three concentrations (15, 25, 80 ng/ml); the intra run relative standard deviation (R.S.D.) was less than 10% and ranged from 5.0 to 8.3%; and the inter-run R.S.D. was less than 10% and ranged from 4.6 to 9.6%. The limits of detection was 2 ng/ml. This assay has been used to evaluate the effect of three human immunodeficiency virus (HIV) protease inhibitors on the metabolism of tacrolimus in human liver microsomes.  相似文献   

12.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers.  相似文献   

13.
A liquid chromatography/tandem mass spectrometry (LC/MS) with atmospheric pressure chemical ionization (APCI) for the quantification of ergosterol, lanosterol, and squalene was developed to evaluate the combination effects of phenolic compounds with fluconazole on ergosterol biosynthesis in Candida albicans. The three analytes were separated by a column of C18 and were quantified without interference with each other using positive mode tandem mass spectrometry (MS/MS). Molecular ions of ergosterol and lanosterol were detected as the [M+H-H2O]+ ion species at m/z 380 and 410, whereas squalene appeared as the [M+H]+ ion species at m/z 412. On fragmentation of ergosterol, lanosterol, and squalene, the product ions at m/z 69, 149, and 109, respectively, were present as major fragments. These product ions were used for the quantification of them in multiple reaction monitoring acquisition mode. The relationship between signal intensity and the analytes' concentration was linear over the concentration range of 0.05-10 microg/ml. Following the treatment of C. albicans with fluconazole in combination with albicanyl caffeate, resveratrol, and 3,4'-difluorostilbene, respectively, the content of ergosterol in both the sensitive and resistant C. albicans showed depletion, whereas the squalene showed accumulation especially in the sensitive isolates determined with the method developed.  相似文献   

14.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of the new anticancer agent picropodophyllin (AXL1717) and its isomer podophyllotoxin levels in human serum has been developed. Monitoring of hexylamine adducts rather than proton adducts was used to optimize sensitivity. The chromatography system was an Acquity BEH C18, 2.1 mm × 50 mm 1.7 μm column with gradient elution (mobile phase A: 2.5 mM hexylamine and 5 mM formic acid in Milli-Q water and mobile phase B: methanol). The retention times were 1.4 min for picropodophyllin, 1.5 min for podophyllotoxin and 1.9 min for internal standard deoxypodophyllotoxin. The isomers were base-line separated. The analytes were detected after electrospray ionization in positive mode with selected reaction monitoring (SRM) with ion transitions m/z 516→102 for picropodophyllin and podophyllotoxin and m/z 500→102 for internal standard. The sample preparation was protein precipitation with acetonitrile (1:3) containing internal standard followed by dilution of the supernatant with mobile phase A (1:1). The limit of quantification (LOQ) was 0.01 μmol/L for picropodophyllin and podophyllotoxin. The limit of detection (LOD) at 3 times the signal to noise (S/N) was estimated below 0.001 μmol/L for picropodophyllin and podophyllotoxin. The quantification range of the method was between 0.01 μmol/L and 5 μmol/L for both isomers. The accuracy was within ±15% of the theoretical value for both picropodophyllin and podophyllotoxin and inter-assay precision did not exceed ±15%, except for the 0.016 μmol/L level of podophyllotoxin, which was 18%. The selectivity of the method was verified by analysis of two different product ions for each analyte and by analysis for interference of seven different batches of blank human serum. The combined recovery and matrix effects were about 83% for picropodophyllin and podophyllotoxin. The new LC-MS/MS method showed sufficient sensitivity and selectivity for determination of picropodophyllin and its isomer podophyllotoxin levels in human serum from subjects receiving therapeutic doses of AXL1717.  相似文献   

15.
Holmes MJ  Teo SL  Khoo HW 《Natural toxins》1999,7(6):361-364
A negative mode liquid chromatography-selected reaction monitoring mass spectrometry (LC-SRM MS) method was developed to detect low concentrations of the diarrhetic shellfish poisoning (DSP) toxins okadaic acid and dinophysistoxin-1 (DTX-1). Detection relies upon monitoring the transition of negative precursor ions [M - H]- to a common fragment ion of m/z 255. Our limit of detection for okadaic acid with this method is 0.5 pg on column. LC-SRM MS has allowed us to detect persistent, low concentrations of DSP toxins from Singapore shellfish.  相似文献   

16.
A rapid and sensitive assay for the determination of dihydroergocryptine (DHEC) in human plasma and urine samples with dihydroergotamine (DHET) as the internal standard was developed. The procedure employs on-line sample preparation using an extraction pre-column and an octadecylsilylsilica (ODS) analytical column. After centrifugation human plasma or urine were injected onto the pre-column, concentrated and extracted, back-flushed onto the analytical column and eluted with a binary methanol--aqueous formic acid gradient. Either determination of DHEC as well of its mono- and dihydroxy-metabolites was performed by measurement of the signal responses from MS detection in the selected reaction monitoring (SRM) mode using the transition of the respective parent ions to the common daughter ion at m/z=270.2 amu. The limit of quantitation (LOQ) for determinations of DHEC in both plasma and urine were 25 pg/ml for injected sample volumes of 400 microl. Proportionality of signal responses versus concentration was accomplished within the range of 25-1000 pg/ml. Recovery of target analyte from plasma was 99%. Mean values of the coefficients of variation (CV) for the target analyte in plasma ranged from 1.7 to 13.8% (within-day) and 5.0 to 9.1% (between-day) and accuracy from 91.7 to 102.6% for the within-day and from 95.8 to 98.8% for the between-day measurements. The corresponding values for determinations in urine were 1.7-14.5% (within-day) and 5.3-11.8% (between-day) for CV and 95.8-110.7% (within-day) and 100.1-104.6% (between-day) for accuracy.  相似文献   

17.
Dage  JL; Ackermann  BL; Halsall  HB 《Glycobiology》1998,8(8):755-760
A simple, fast and sensitive method was developed to verify the presence of the sialyl Lewis(x) antigen on an N-linked glycoprotein. High performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI/MS) was used to identify which of the five N-linked glycosylation sites of human plasma alpha1-acid-glycoprotein (orosomucoid, OMD) contain the sialyl Lewis(x) antigen. OMD was digested with proteolytic enzymes and analyzed by reversed phase chromatography coupled with on-line ESI/MS. A tandem mass spectrometry experiment was designed to detect the presence of the sialyl Lewis(x) antigen based on the observation of an 803 mass to charge ratio ( m/z ) ion produced in the intermediate pressure region of the ESI interface. The ESI/MS signal at m/z 803 is consistent with an oxonium ion for a glycan structure containing NeuAc, Gal, GlcNAc, and Fuc. The identity of the m/z 803 ion was confirmed by ESI/MS/MS analysis of the m/z 803 fragment ion and comparison with a sialyl Lewis(x) standard. The stereochemistry and linkage positions were assigned using previous NMR analysis but could be determined with permethylation analysis if necessary. The analysis of OMD gave a pattern showing signal for the sialyl Lewis(x) antigen coeluting with each of the five N-linked glycopeptides. The ability to monitor sialyl Lewis(x) expression at each of the five sites is of interest in the study of OMD's role in inflammatory diseases.   相似文献   

18.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil.  相似文献   

19.
A rapid, specific and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for simultaneous quantitation of six Aconitum alkaloids, i.e. aconitine (AC), mesaconitine (MA), hypaconitine (HA), benzoylaconine (BAC), benzoylmesaconine (BMA) and benzoylhypaconine (BHA) in human plasma collected from 18 healthy volunteers after intravenous drop infusion of "SHEN-FU" injectable powder in three different dosages. Lappaconitine was selected as the internal standard (IS). LC/MS/MS system coupled with an electrospray ionization (ESI) source was performed in multiple-reaction monitoring (MRM) mode. The transitions of the Aconitum alkaloids executed as following: m/z 646.3-->586.0 for AC; m/z 632.4-->573.1 for MA; m/z 616.2-->556.1 for HA; m/z 604.2-->104.8 for BAC; m/z 590.1-->104.8 for BMA; m/z 574.1-->104.8 for BHA; m/z 585.2-->161.8 for IS. Sample preparation was performed with solid-phase extraction (SPE) on a 1 mL HLB cartridge prior to analysis. The separation was applied on a Waters C(18) column (1.7 microm, 2.1 mm x 100 mm) and a gradient elution of methanol and 0.1% formic acid-water was used as mobile phase. The retention time was less than 4.5 min. The concentrations ranged from 0.1 to 1000 ng/mL for all six Aconitum alkaloids and showed a good linearity with the correlation coefficient (r(2)) >0.995. The validated method was employed to simultaneous quantitation and successfully used for the first time for the pharmacokinetic evaluation of the six Aconitum alkaloids after intravenous drop administration of "SHEN-FU" injectable powder in phase I clinical trial.  相似文献   

20.
A sensitive method for the determination of glutathione (GSH) and glutathione disulfide (GSSG) in human saliva was developed and validated. GSH was captured and stabilized by the addition of N-ethylmaleimide (NEM). Solid-phase extraction (SPE) using an Oasis MAX extraction cartridge was employed for sample preparation and analysis was performed on a Shimadzu LCMS-2010 A that was operated in the single ion monitoring mode using positive ion electrospray ionization (ESI) as the interface. The monitored ion for GSH-NEM was m/z 433 and that for GSSG was m/z 613. Chromatography was carried out on an Atlantis HILIC silica column (150 mm x 2.1 mm, 5 microm) with acetonitrile and formate buffer as the mobile phase at the flow rate of 0.2 ml/min. The calibration curve was linear over the range of 0.1-100 microM for GSH-NEM. The extraction recoveries of GSH-NEM spiked at concentrations of 25 and 50 microM were 97.1 and 104.4%, respectively. Similar results were obtained for GSSG. The newly developed hydrophilic interaction chromatography with mass spectrometry (HILIC/MS) method showed superior sensitivity for the determination of GSH and GSSG in human saliva samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号