共查询到20条相似文献,搜索用时 25 毫秒
1.
Anna Bandurska-Luque Tomasz Piotrowski Agnieszka Skroba?a Adam Ryczkowski Krystyna Adamska Joanna Ka?mierska 《Reports of Practical Oncology and Radiotherapy》2015,20(2):145-152
Aim
This prospective study aims to assess feasibility of helical tomotherapy (HT) for craniospinal irradiation (CSI) and perform dosimetric comparison of treatment plans for both HT and 3D conformal radiotherapy (3DCRT).Background
CSI is a challenging procedure. Large PTV size requires field matching due to technical limitations of standard linear accelerators, which cannot irradiate such volumes as a single field. HT could help to avoid these limitations as irradiation of long fields is possible without field matching.Materials and methods
Three adults were enrolled from 2009 to 2010. All patients received radiochemotherapy. Treatment plans in prone position for 3DCRT and in supine position for HT were generated. The superior plan was used for patients’ irradiation. Plans were compared with the application of DVH, Dx parameters – where x represents a percentage of the structure volume receiving a normalized dose and homogeneity index (HI).Results
All patients received HT irradiation. The treatment was well tolerated. The HT plans resulted in a better dose coverage and uniformity in the PTV: HI were 5.4, 7.8, 6.8 for HT vs. 10.3, 6.6, 10.4 for 3DCRT. For most organs at risk (OARs), the D(V80) was higher for HT than for 3DCRT, whereas D(V5) was lower for HT.Conclusions
HT is feasible for CSI, and in comparison with 3DCRT it improves PTV coverage. HT reduces high dose volumes of OARs, but larger volumes of normal tissue receive low radiation dose. HT requires further study to establish correlations between dosimetrical findings and clinical outcomes, especially with regard to late sequelae of treatment. 相似文献2.
Tomasz Bajon Tomasz Piotrowski Andrzej Antczak Bartosz B?k Barbara B?asiak Joanna Ka?mierska 《Reports of Practical Oncology and Radiotherapy》2011,16(2):65-70
Aim
To compare DVHs for OARs in two different positions – prone and supine – for prostate cancer patients irradiated with a Tomotherapy unit.Background
In the era of dose escalation, the choice of optimal patient immobilization plays an essential role in radiotherapy of prostate cancer.Materials and methods
The study included 24 patients who were allocated to 3 risk groups based on D’Amico criteria; 12 patients represented a low or intermediate and 12 a high risk group.For each patient two treatment plans were performed: one in the supine and one in the prone position. PTV included the prostate, seminal vesicles and lymph nodes for the high risk group and the prostate and seminal vesicles for the intermediate or low risk groups. DVHs for the two positions were compared according to parameters: Dmean, D70, D50 and D20 for the bladder and rectum and Dmean, D10 for the intestine. The position accuracy was verified using daily MVCT.Results
Prone position was associated with lower doses in OARs, especially in the rectum. Despite the fact that in the entire group the differences between tested parameters were not large, the Dmean and D10 for the intestine were statistically significant. In the case of irradiation only to the prostate and seminal vesicles, the prone position allowed for substantial reduction of all tested DVH parameters in the bladder and rectum, except D20 for bladder. Moreover, the Dmean and D50 parameter differences for the bladder were statistically significant.No significant differences between positions reproducibility were demonstrated.Conclusion
In patients irradiated to prostate and seminal vesicles, the prone position may support sparing of the rectum and bladder.The reproducibility of position arrangement in both positions is comparable. 相似文献3.
Tomasz Piotrowski Slav Yartsev George Rodrigues Tomasz Bajon 《Reports of Practical Oncology and Radiotherapy》2014,19(3):206-213
Aim/Background
The analysis of systematic and random errors obtained from the pooled data on inter-fraction prostate motion during radiation therapy in two institutions.Materials and methods
Data of 6085 observations for 216 prostate cancer patients treated on tomotherapy units in two institutions of position correction shifts obtained by co-registration of planning and daily CT studies were investigated. Three independent variables: patient position (supine or prone), target (prostate or prostate bed), and imaging mode (normal or coarse) were analyzed. Systematic and random errors were evaluated and used to calculate the margins for different options of referencing based on the position corrections observed with one, three, or five imaging sessions.Results
Statistical analysis showed that only the difference between normal and coarse modes of imaging was significant, which allowed to merge the supine and prone position sub-groups as well as the prostate and prostate bed patients. In the normal and coarse imaging groups, the margins calculated using systematic and random errors in the medio-lateral and cranio-caudal directions (5.5 mm and 4.5 mm, respectively) were similar, but significantly different (5.3 mm for the normal mode and 7.1 mm for the coarse mode) in the anterio-posterior direction. The reference scheme based on the first three fractions (R3) was found to be the optimal one.Conclusions
The R3 reference scheme effectively reduced systematic and random errors. Larger margins in the anterio-posterior direction should be used during prostate treatment on the tomotherapy unit, as coarse imaging mode is chosen in order to reduce imaging time and dose. 相似文献4.
Anna ?ladowska Marcin Hetna? Pawe? Dymek Damian Kabat Kamil Kisielewicz Micha? Wawrzak Pawe? Zawadzki Jan Lesiak Edward Byrski Micha? Waligórski 《Reports of Practical Oncology and Radiotherapy》2011,16(3):110-114
Background
Fracture of the femur is the most frequent late complication in patients with soft tissue sarcomas (STS) who receive external beam radiotherapy after limb-sparing surgery.Aim
To reduce the risk of bone fracture following radiotherapy of STS of the thigh, we minimized the dose to the femur and to surrounding normal tissues by applying intensity modulated radiation therapy (IMRT). We report preliminary results of post-surgery IMRT of the thigh in patients with STS in this extremity.Materials and methods
10 adult patients undergoing post-operative radiotherapy of STS of the thigh were treated using IMRT. Clinical IMRT plans with simultaneous integrated boost (SIB) and 3-phase three-dimensional conformal radiotherapy (3D-CRT) were designed to adequately treat the planning target volume and to spare the femur to the largest extent possible. Dose distributions and dose-volume histograms were compared.Results
For either technique, a comparable target coverage was achieved; however, target volume was better covered and critical structures were better spared in IMRT plans. Mean and maximum doses to OAR structures were also significantly reduced in the IMRT plans. On average, the mean dose to the femur in 3D-CRT plans was about two times higher than that in IMRT plans.Conclusion
Compared with 3D-CRT, the application of IMRT improves the dose distribution within the concave target volumes and reduces dose to the OAR structures without compromising target coverage. 相似文献5.
Stacie Deiner Isaac Chu Michelle Mahanian Hung-Mo Lin Andrew C. Hecht Jeffrey H. Silverstein 《PloS one》2014,9(9)
Purpose
A variety of hemodynamic and respiratory alterations accompany patients in the prone position; however the effect of the prone position on intraoperative cerebral saturation has not been studied. We sought to examine whether the incidence of cerebral oxygen desaturation in elderly patients (≥68 years of age) undergoing spine surgery in the prone position was more common than patients undergoing major surgery in the supine position.Methods
We performed a retrospective cohort study of 205 patients; 63 patients underwent surgery in the prone position and 142 in the supine position. Patients were evaluated for cerebral desaturation with bilateral cerebral oximetry. The primary predictor was position, secondary were: length of the surgery, incidence and duration of cerebral desaturation episodes at several thresholds, average time of Bispectral index below threshold of 45 in minutes, average electroencephalogram suppression ratio >0, amount of blood transfused, and the incidence of hypotension and hypertension.Results
Elderly spine surgery patients in the prone position were more than twice as likely to experience mild cerebral desaturation as patients in the supine position. Patients in the prone position had longer surgeries; however cerebral desaturation in the prone position was significantly more common even when adjusted for surgery time and the occurrence of intraoperative hypotension.Conclusion
Cerebral desaturation is related to the prone position in elderly surgery patients. Future studies are necessary to determine whether this translates to a higher incidence of postoperative cognitive dysfunction and delirium. 相似文献6.
Krzysztof ?losarek Wojciech Osewski Aleksandra Grz?dziel Micha? Radwan ?ukasz Dolla Marta Szlag Ma?gorzata St?pór-Fudzińska 《Reports of Practical Oncology and Radiotherapy》2015,20(2):99-103
Aim
Comparisons of integral dose delivered to the treatment planning volume and to the whole patient body during stereotactic, helical and intensity modulated radiotherapy of prostate.Background
Multifield techniques produce large volumes of low dose inside the patient body. Delivered dose could be the result of the cytotoxic injuries of the cells even away from the treatment field. We calculated the total dose absorbed in the patient body for four radiotherapy techniques to investigate whether some methods have a potential to reduce the exposure to the patient.Materials and methods
We analyzed CyberKnife plans for 10 patients with localized prostate cancer. Five alternative plans for each patient were calculated with the VMAT, IMRT and TomoTherapy techniques. Alternative dose distributions were calculated to achieve the same coverage for PTV. Integral Dose formula was used to calculate the total dose delivered to the PTV and whole patient body.Results
Analysis showed that the same amount of dose was deposited to the treated volume despite different methods of treatment delivery. The mean values of total dose delivered to the whole patient body differed significantly for each treatment technique. The highest integral dose in the patient''s body was at the TomoTherapy and CyberKnife treatment session. VMAT was characterized by the lowest integral dose deposited in the patient body.Conclusions
The highest total dose absorbed in normal tissue was observed with the use of a robotic radiosurgery system and TomoTherapy. These results demonstrate that the exposure of healthy tissue is a dosimetric factor which differentiates the dose delivery methods. 相似文献7.
Marta Krystyna Gizynska Anna Zawadzka Wojciech Bulski 《Reports of Practical Oncology and Radiotherapy》2010,15(6):155-160
Aim
The purpose of this study was to examine the usefulness of using Simultaneous Integrated Boost (SIB) radiotherapy for thyroid cancer treatment.Background
At our hospital a 3D Conformal RadioTherapy (3D-CRT) technique involving photon and electron beams for the treatment of thyroid cancer was often used.1 High dose to the spinal canal was limiting the total dose of such a treatment. After investigation of Intensity Modulated Radiotherapy (IMRT) technique involving seven photon beams for first course of treatment3 we decided to examine possibility of reducing treatment fractions by using SIB radiotherapy.Material and methods
Plans for 10 patients were studied. For each patient, IMRT plan for the first course of treatment (50 Gy for PTV), two plans for the second course of treatment (10 Gy for BOOST) and a SIB plan (50 Gy for PTV, 56 Gy for BOOST) were prepared. For all plans, comparisons of dose statistics for the PTV, BOOST, PTV without BOOST (defined as PTV without BOOST with 1 cm margin), spinal canal and Patient Outline (Body) was done.Results
Minimum dose for BOOST is higher in the SIB technique than in the two course treatment. PTV without BOOST receives the same average dose in SIB and the 1st course IMRT – 50.10 Gy and 49.84 Gy, respectively. In the SIB technique, higher reduction of dose delivered to the spinal canal is possible (27 Gy compared with 30 Gy).Conclusion
SIB therapy for thyroid cancer with relation to typical two course treatment is a good proposal of reducing the number of fractions with the same dose for BOOST and PTV without BOOST. Additionally, better sparing of the spinal canal is achieved. 相似文献8.
Purpose
Flattening filter free (FFF) beams show the potential for a higher dose rate and lower peripheral dose. We investigated the planning study of FFF beams with their role for volumetric modulated arc therapy (VMAT) in squamous cell carcinoma of the scalp.Methods and Materials
One patient with squamous cell carcinoma which had involvement of entire scalp was subjected to VMAT using TrueBeam linear accelerator. As it was a rare skin malignancy, CT data of 7 patients with brain tumors were also included in this study, and their entire scalps were outlined as target volumes. Three VMAT plans were employed with RapidArc form: two half-field full-arcs VMAT using 6 MV standard beams (HFF-VMAT-FF), eight half-field quarter-arcs VMAT using 6 MV standard beams (HFQ-VMAT-FF), and HFQ-VMAT using FFF beams (HFQ-VMAT-FFF). Prescribed dose was 25×2 Gy (50 Gy). Plan quality and efficiency were assessed for all plans.Results
There were no statistically significant differences among the three VMAT plans in target volume coverage, conformity, and homogeneity. For HFQ-VMAT-FF plans, there was a significant decrease by 12.6% in the mean dose to the brain compared with HFF-VMAT-FF. By the use of FFF beams, the mean dose to brain in HFQ-VMAT-FFF plans was further decreased by 7.4% compared with HFQ-VMAT-FF. Beam delivery times were similar for each technique.Conclusions
The HFQ-VMAT-FF plans showed the superiority in dose distributions compared with HFF-VMAT-FF. HFQ-VMAT-FFF plans might provide further normal tissue sparing, particularly in the brain, showing their potential for radiation therapy in squamous cell carcinoma of the scalp. 相似文献9.
Rajesh Thiyagarajan Arunai Nambiraj Sujit Nath Sinha Girigesh Yadav Ashok Kumar Vikraman Subramani Kothandaraman 《Reports of Practical Oncology and Radiotherapy》2016,21(1):50-56
Aim
The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.Background
VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system.Materials and methods
Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values.Results
The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement.Conclusions
The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA. 相似文献10.
Vis JC De Bruin-Bon HA Bouma BJ Huisman SA Imschoot L van den Brink K Mulder BJ 《Netherlands heart journal》2012,20(6):264-269
Objective
Physical fitness is reduced in adults with Down syndrome (DS). The present study was conducted to elucidate the exercise response in adults with DS.Design
Case controlled before-after trial.Setting
Residential centre for people with intellectual disabilities.Participants
96 Adults with DS, 25 non-DS adults with an intellectual disability, 33 controls.Interventions
Echocardiography to exclude heart defects and to measure cardiac index (CI) in the supine position, supine position with raised legs, and following ten knee bends.Main outcome measure
Exercise testingResults
At rest, mean CI was not significantly different between persons with DS and controls (2.3 vs. 2.4 l/min/m2, p = 0.3). However, mean CI after exercise was significantly lower in DS (2.9 vs. 3.7 l/min/m2, p < 0.001) and mean CI increase from rest to exercise was more than 50% lower in DS. On the contrary, CI after exercise was similar among controls and non-DS adults with an intellectual disability. Significantly lower stroke volumes in DS were found with insufficient heart rate response.Conclusions
CI at rest was similar in adults with DS and controls; however persons with DS have a diminished cardiac response to exercise. Stroke volumes were significantly lower in DS during exercise and a compensated heightened heart rate was absent. 相似文献11.
David Corwin Clay Holdsworth Russell C. Rockne Andrew D. Trister Maciej M. Mrugala Jason K. Rockhill Robert D. Stewart Mark Phillips Kristin R. Swanson 《PloS one》2013,8(11)
Purpose
To demonstrate a method of generating patient-specific, biologically-guided radiotherapy dose plans and compare them to the standard-of-care protocol.Methods and Materials
We integrated a patient-specific biomathematical model of glioma proliferation, invasion and radiotherapy with a multiobjective evolutionary algorithm for intensity-modulated radiation therapy optimization to construct individualized, biologically-guided plans for 11 glioblastoma patients. Patient-individualized, spherically-symmetric simulations of the standard-of-care and optimized plans were compared in terms of several biological metrics.Results
The integrated model generated spatially non-uniform doses that, when compared to the standard-of-care protocol, resulted in a 67% to 93% decrease in equivalent uniform dose to normal tissue, while the therapeutic ratio, the ratio of tumor equivalent uniform dose to that of normal tissue, increased between 50% to 265%. Applying a novel metric of treatment response (Days Gained) to the patient-individualized simulation results predicted that the optimized plans would have a significant impact on delaying tumor progression, with increases from 21% to 105% for 9 of 11 patients.Conclusions
Patient-individualized simulations using the combination of a biomathematical model with an optimization algorithm for radiation therapy generated biologically-guided doses that decreased normal tissue EUD and increased therapeutic ratio with the potential to improve survival outcomes for treatment of glioblastoma. 相似文献12.
Janusz Winiecki Zbigniew ?urawski Barbara Drzewiecka Krzysztof ?losarek 《Reports of Practical Oncology and Radiotherapy》2011,16(1):1-9
Background
During a proper execution of dMLC plans, there occurs an undesired but frequent effect of the dose locally accumulated by tissue being significantly different than expected. The conventional dosimetric QA procedures give only a partial picture of the quality of IMRT treatment, because their solely quantitative outcomes usually correspond more to the total area of the detector than the actually irradiated volume.Aim
The aim of this investigation was to develop a procedure of dynamic plans verification which would be able to visualize the potential anomalies of dose distribution and specify which tissue they exactly refer to.Materials & methods
The paper presents a method discovered and clinically examined in our department. It is based on a Gamma Evaluation concept and allows accurate localization of deviations between predicted and acquired dose distributions, which were registered by portal as well as film dosimetry. All the calculations were performed on the self-made software GammaEval, the γ-images (2-dimensional distribution of γ-values) and γ-histograms were created as quantitative outcomes of verification.Results
Over 150 maps of dose distribution have been analyzed and the cross-examination of the gamma images with DRRs was performed.Conclusions
It seems, that the complex monitoring of treatment would be possible owing to the images obtained as a cross-examination of γ-images and corresponding DRRs. 相似文献13.
Takashi Kawahara Hiroki Ito Hideyuki Terao Yoshitake Kato Hiroji Uemura Yoshinobu Kubota Junichi Matsuzaki 《PloS one》2012,7(12)
Objective
To determine the impact of ureteroscopy-assisted retrograde nephrostomy (UARN) during percutaneous nephrolithotomy (PCNL).Materials and Methods
From April 2009 to September 2011, a total of 50 patients underwent PCNL for large renal stones (stone burden >2 cm). We performed UARN in the Galdakao-modified Valdivia position for 27 patients (UARN PCNL) and ultrasonography-assisted percutaneous nephrostomy in the prone position for 23 patients (prone PCNL).Results
UARN PCNL significantly improved the stone-free rate (81.5% vs 52.2%) and the rate of residual stones (<4 mm, 92.6% vs 65.2%, P<0.05). The median length of the operation was significantly shorter for UARN PCNL, at 160 min, compared to 299 min for prone PCNL (P<0.001). There was one intraoperative complication in prone PCNL, namely a hemorrhage that resulted in stopping the initial treatment, but it was cured conservatively. The postoperative complications included a high grade fever that persisted for three days in two UARN PCNL patients (7.4%) and six prone PCNL patients (26.1%). The Clavien grading scores showed significantly lower postoperative complications for UARN PCNL compared to prone PCNL.Conclusion
UARN is associated with a higher stone-free rate, shorter operation time, and fewer complications during PCNL than prone PCNL. 相似文献14.
15.
Purpose
To determine whether negative associations between enrollment in a high-deductible health plan (HDHP) and one exemplar unhealthy behavior – daily smoking – are found only among people who chose these plans.Design
Cross-sectional analysis of nationally-representative data.Setting
United States from 2007 to 2008.Subjects
6,941 privately insured non-elderly adult participants in the 2007 Health Tracking Household Survey.Measures
Self-reported smoking status.Analysis
We classified subjects as HDHP or traditional health plan enrollees with employer-sponsored insurance (ESI) and no choice of plans, ESI with a choice of plans, or coverage through the non-group market. We used multivariate logistic regression to measure associations between HDHP enrollment and daily smoking within each of the 3 coverage source groups while controlling for potential confounders.Results
HDHP enrollment was associated with lower odds of smoking among individuals with ESI and a choice of plans (AOR 0.55, 95% CI 0.33–0.90) and those with non-group coverage (AOR 0.64, 95% CI 0.34–1.22), though the latter association was not statistically significant. HDHP enrollment was not associated with lower odds of smoking among individuals with ESI and no choice of plans (AOR 1.04, 95% CI 0.69–1.56).Conclusions
HDHP enrollment is associated with lower odds of smoking only among individuals who chose to enroll in an HDHP. Lower rates of unhealthy behaviors among HDHP enrollees may be a reflection of individuals who choose these plans. 相似文献16.
Patrycja Mantaj Grzegorz Zwierzchowski 《Reports of Practical Oncology and Radiotherapy》2013,18(3):139-147
Aim
The aim of the study was to verify the dose distribution optimisation method in pulsed brachytherapy.Background
The pulsed-dose rate brachytherapy is a very important method of breast tumour treatment using a standard brachytheraphy equipment. The appropriate dose distribution round an implant is an important issue in treatment planning. Advanced computer systems of treatment planning are equipped with algorithms optimising dose distribution.Materials and methods
The wax-paraffin phantom was constructed and seven applicators were placed within it. Two treatment plans (non-optimised, optimised) were prepared. The reference points were located at a distance of 5 mm from the applicators’ axis. Thermoluminescent detectors were placed in the phantom at suitable 35 chosen reference points.Results
The dosimetry verification was carried out in 35 reference points for the plans before and after optimisation. Percentage difference for the plan without optimisation ranged from −8.5% to 1.4% and after optimisation from −8.3% to 0.01%. In 16 reference points, the calculated percentage difference was negative (from −8.5% to 1.3% for the plan without optimisation and from −8.3% to 0.8% for the optimised plan). In the remaining 19 points percentage difference was from 9.1% to 1.4% for the plan without optimisation and from 7.5% to 0.01% for the optimised plan.No statistically significant differences were found between calculated doses and doses measured at reference points in both dose distribution non-optimised treatment plans and optimised treatment plans.Conclusions
No statistically significant differences were found in dose values at reference points between doses calculated by the treatment planning system and those measured by TLDs. This proves the consistency between the measurements and the calculations. 相似文献17.
Thibaud P. Coroller Raymond H. Mak John H. Lewis Elizabeth H. Baldini Aileen B. Chen Yolonda L. Colson Fred L. Hacker Gretchen Hermann David Kozono Edward Mannarino Christina Molodowitch Jon O. Wee David J. Sher Joseph H. Killoran 《PloS one》2014,9(4)
Purpose
To examine the frequency and potential of dose-volume predictors for chest wall (CW) toxicity (pain and/or rib fracture) for patients receiving lung stereotactic body radiotherapy (SBRT) using treatment planning methods to minimize CW dose and a risk-adapted fractionation scheme.Methods
We reviewed data from 72 treatment plans, from 69 lung SBRT patients with at least one year of follow-up or CW toxicity, who were treated at our center between 2010 and 2013. Treatment plans were optimized to reduce CW dose and patients received a risk-adapted fractionation of 18 Gy×3 fractions (54 Gy total) if the CW V30 was less than 30 mL or 10–12 Gy×5 fractions (50–60 Gy total) otherwise. The association between CW toxicity and patient characteristics, treatment parameters and dose metrics, including biologically equivalent dose, were analyzed using logistic regression.Results
With a median follow-up of 20 months, 6 (8.3%) patients developed CW pain including three (4.2%) grade 1, two (2.8%) grade 2 and one (1.4%) grade 3. Five (6.9%) patients developed rib fractures, one of which was symptomatic. No significant associations between CW toxicity and patient and dosimetric variables were identified on univariate nor multivariate analysis.Conclusions
Optimization of treatment plans to reduce CW dose and a risk-adapted fractionation strategy of three or five fractions based on the CW V30 resulted in a low incidence of CW toxicity. Under these conditions, none of the patient characteristics or dose metrics we examined appeared to be predictive of CW pain. 相似文献18.
Charles Mayo Luis Fong de los Santos Jon Kruse Charles R. Blackwell Luke B. McLemore Deanna Pafundi Joshua Stoker Michael Herman 《PloS one》2013,8(3)
Introduction
Results of use of methodology for VMAT commissioning and quality assurance, utilizing both control point tests and dosimetric measurements are presented.Methods and Materials
A generalizable, phantom measurement approach is used to characterize the accuracy of the measurement system. Correction for angular response of the measurement system and inclusion of couch structures are used to characterize the full range gantry angles desirable for clinical plans. A dose based daily QA measurement approach is defined.Results
Agreement in the static vs. VMAT picket fence control point test was better than 0.5 mm. Control point tests varying gantry rotation speed, leaf speed and dose rate, demonstrated agreement with predicted values better than 1%. Angular dependence of the MatriXX array, varied over a range of 0.94–1.06, with respect to the calibration condition. Phantom measurements demonstrated central axis dose accuracy for un-modulated four field box plans was ≥2.5% vs. 1% with and without angular correction respectively with better results for VMAT (0.4%) vs. IMRT (1.6%) plans. Daily QA results demonstrated average agreement all three chambers within 0.4% over 9 month period with no false positives at a 3% threshold.Discussion
The methodology described is simple in design and characterizes both the inherit limitations of the measurement system as well at the dose based measurements that may be directly related to patient plan QA. 相似文献19.
Philip Verdonck Alain F. Kalmar Koen Suy Thomas Geeraerts Marcel Vercauteren Alex Mottrie Andre M. De Wolf Jan F. A. Hendrickx 《PloS one》2014,9(11)
Background
During robot assisted laparoscopic radical prostatectomy (RALRP), a CO2 pneumoperitoneum (CO2PP) is applied and the patient is placed in a head-down position. Intracranial pressure (ICP) is expected to acutely increase under these conditions. A non-invasive method, the optic nerve sheath diameter (ONSD) measurement, may warn us that the mechanism of protective cerebrospinal fluid (CSF) shifts becomes exhausted.Methods
After obtaining IRB approval and written informed consent, ONSD was measured by ocular ultrasound in 20 ASA I–II patients at various stages of the RALRP procedure: baseline awake, after induction, after applying the CO2PP, during head-down position, after resuming the supine position, in the postoperative anaesthesia care unit, and on day one postoperatively. Cerebral perfusion pressure (CPP) was calculated as the mean arterial (MAP) minus central venous pressure (CVP).Results
The ONSD did not change during head-down position, although the CVP increased from 4.2(2.5) mm Hg to 27.6(3.8) mm Hg. The CPP was decreased 70 min after assuming the head-down position until 15 min after resuming the supine position, but remained above 60 mm Hg at all times.Conclusion
Even though ICP has been documented to increase during CO2PP and head-down positioning, we did not find any changes in ONSD during head-down position. These results indicate that intracranial blood volume does not increase up to a point that CSF migration as a compensation mechanism becomes exhausted, suggesting any increases in ICP are likely to be small. 相似文献20.
Alejandro Floriano Icíar Santa-Olalla Alberto Sanchez-Reyes 《Reports of Practical Oncology and Radiotherapy》2013,18(3):173-178