首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
韩静  陈晨  曹红  陈福勇 《病毒学报》2005,21(4):293-297
将禽白血病病毒(ALV)的p27基因克隆人表达性载体pET28a,在大肠杆菌以His Tag融合蛋白的形式获得了高效表达。以表达产物免疫家兔,制备了抗ALV p27的多克隆抗体,经亲和纯化后,用此抗体建立了对ALV抗原的双抗体夹心法ELISA,并对疑似病料进行了实验室诊断。检测结果与IDEXX的禽白血病抗原检测试剂盒符合率达到98.6%,证明表达产物保留了天然p27蛋白的相关抗原性。交叉试验和群特异性试验证明,此方法具有良好的特异件,并且可以检测出A、B、J亚群的禽白血病病毒p27抗原。用此ALV抗体和所建立的ELISA方法成功地进行了禽白血病病毒抗原的实验室诊断。  相似文献   

2.
Rhesus macaques were immunized with live vaccinia virus recombinants expressing the envelope glycoproteins (gp70 and gp22) of simian type D retrovirus (SRV), serotype 1 or 3. All of the animals immunized with either the SRV-1 env or the SRV-3 env vaccinia virus recombinant developed neutralizing antibodies against the homologous SRV. In addition, both groups developed cross-reactive antibodies and were protected against an intravenous live-virus challenge with SRV-1. The four control animals immunized with a vaccinia virus recombinant expressing the G protein of respiratory syncytial virus were not protected against the same SRV-1 challenge. Although SRV-1 and SRV-3 immune sera showed cross-neutralization, they failed to neutralize a separate, more distantly related serotype, SRV-2, in an in vitro assay. These findings are consistent with the known degree of serologic and genetic relatedness of these three SRV strains.  相似文献   

3.
Monoclonal antibodies (MoAbs) to the major gag core protein p27 and a viral protein p44 of type D retrovirus (SRV-2) were produced and used in the detection of SRV-2 antigens in infected Raji cells and in tissues from macaques with simian acquired immunodeficiency syndrome (SAIDS) and retroperitoneal fibromatosis (RF). Anti-p44 MoAb showed inhibition of syncytium formation by both SRV-1- and SRV-2-infected Raji cells.  相似文献   

4.
5.
The object of this study was to develop a simple, rapid, specific, and highly sensitive method to detect HCV core antigen. A nucleic acid aptamer was designed with the high specificity and sensitivity in a nucleic acid lateral flow strip to compete with HCV core antigen and DNA probes. The lower detection limit of the test strip was calculated to be 10 pg/mL with the scanner and 100 pg/mL with naked eyes. Results showed that there were no cross-interactions with other proteins such as HCV NS3, E1/E2 antigens, HIV p24 antigens, or BSA proteins (HCV unrelated protein). When the viral load exceeded 104 copies/mL, the positive coincidence rates of ELISA and strip detection, when compared with the HCV RNA assay, were 98.44% and 97.28%, respectively. The results indicated that the ELISA detection and strip assay were in good agreement with the measured value. The results indicated that a nucleic acid lateral flow strip was a simple, rapid, specific, highly sensitive, and cost-effective field-based method for detecting HCV core antigen. The strip assay is an acceptable alternative to diagnose HCV core antigen and to investigate its epidemiology in clinical laboratories lacking specialized equipment and skills.  相似文献   

6.
Celebes macaques were tested for type D simian retrovirus (SRV) infection. SRV infection was first detected in one serum sample collected during 1980. By 1983, 32 of 46 monkeys (70%) were infected. Serotyping of the SRV isolates determined that 0/26 of the isolates were SRV-1; 24/26 were SRV-2; 1/26 was SRV-5; and 1/26 could not be typed. Restriction endonuclease mapping confirmed the SRV-2C and SRV-5 isolates. In addition, two SRV-2C variants were detected.  相似文献   

7.
8.
ABSTRACT: BACKGROUND: HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1) which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA) with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA) assays combined with polymerase chain reaction (PCR) and gel electrophoresis to quantify HIV-1 p24 antigen. METHOD: A pair of anti-p24 monoclonal antibodies (mAbs) were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs) to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs) containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. RESULTS: The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD) of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. CONCLUSIONS: When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3--4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected with HIV.  相似文献   

9.
Three monoclonal antibodies to human T cell lymphotropic virus type I (HTLVI) p19 internal core protein, designated as alpha HTLV-2, 3, and 4, have been developed. In indirect immunofluorescence (IF) assays, these antibodies reacted with acetone-fixed cytocentrifuge preparations of culture HTLVI-infected peripheral blood leukocyte (PBL) from a patient (SD) with Japanese adult T cell leukemia and with infected HUT-102 T cells but not with cultured normal PBL. Anti-p19 antibodies alpha HTLV-2, 3, and 4 all reacted with the same HTLVI p19 identified both by antibodies in HTLVI+ patient sera and by antisera raised against two synthetic peptides encoded by the p19 gag region of HTLVI. Partial proteolytic cleavage of p19 immunoprecipitates obtained with antibodies alpha HTLV-2, 3, and 4 produced a 17,000-dalton cleavage product, in agreement with the size of the fragment predicted from the nucleic acid sequence of the HTLVI p19 gag region. Antibodies alpha HTLV-3 and 4 reacted with HTLVI but not HTLVII proteins and were useful diagnostic probes in identifying HTLVI- but not HTLVII-infected lymphoid cells in immunofluorescence assays. In addition to reacting with HTLVI p19, antibodies 2 and 4 also cross-reacted with a wide variety of HTLV-uninfected normal and neoplastic cells and tissues. In addition, HTLVI+ patient sera contained antibodies that competed for binding to the antigenic site on p19 recognized by antibody 4. Thus, anti-p19 monoclonal antibodies alpha HTLV-2 and 4 reacted with a 19,000-dalton viral-encoded protein of HTLVI and cross-reacted with normal host tissues, while anti-p19 antibody alpha HTLV-3 was specific for HTLVI p19 core protein.  相似文献   

10.
Reactivity of sera from patients with primary biliary cirrhosis (PBC) with a 60 kDa component of nuclear pore complexes (NPCs), purified by affinity chromatography on wheat-germ agglutinin (WGA)-Sepharose, was previously detected. Recently, clinical significance of the anti-NPC antibodies in PBC became evident. In the light of recent reports, indicating the correlation of the anti-NPC antibodies with severity and progression of the disease, the characterization of the reactive antigens is becoming essential in the clinical management of patients with PBC. Since accurate autoantibody detection represents one of the fundamental requirements for a reliable testing, we have generated a human recombinant p62 protein and validated an immunoprecipitation assay for the detection of anti-p62. We also demonstrated that the generated human recombinant p62 nucleoporin was modified by N-acetylglucosamine residues. More than 50% of tested PBC sera precipitated (35)S-radioactively labeled p62 recombinant nucleoporin and 40% recognized this recombinant antigen by immunoblotting. We compared the reactivity of PBC sera with rat and human nucleoporin. The incidence of anti-p62 nucleoporin positive PBC sera increased by 15% when human recombinant antigen was used. The titer of autoantibodies in p62-positive PBC samples strongly varied. Preadsorption of the PBC sera with p62 recombinant protein completely abolished their reactivity with the antigen. In conclusion, this study unequivocally proves that autoantibodies reacting with the 60 kDa component of NPCs target p62 nucleoporin and, more importantly, provide a better antigen source for future evaluations of the clinical role of anti-p62 in PBC.  相似文献   

11.
The serologic detection of anti-Toxoplasma gondii immunoglobulins plays a key role in the clinical diagnosis of Toxoplasmosis. In this paper, a simple, rapid and highly sensitive agglutination-based piezoelectric immunoassay has been firstly developed for directly detecting anti-T. gondii immunoglobulins in infected rabbit serum (IRS) and infected rabbit blood (IRB). The proposed technique is based on that the specific agglutination of antigen-coated gold nanoparticles, averaging 10nm in diameter, in the presence of the corresponding antibody causes a frequency change that is monitored by a piezoelectric device. In contrast to the commonly used piezoelectric assays, it possesses an attractive advantage in that the immobilization of antibody or antigen on the crystal is unnecessary. Use of a newly prepared sensing probe which was modified by a plasma-polymerized film (PPF) of n-butyl amine and further by a heparin layer resulted in a response-enhanced immunoagglutination and a high compatibility of the probe with biological samples. An appropriate reagent consisting of 1% normal rabbit serum (NRS) and 0.1% bovine serum albumin (BSA) for diluting the analytes were verified in counteracting the background interference of assay. Moreover, an optimization of assay medium composition with the addition of poly(ethylene glycol) (PEG) serving as immunoagglutination rate and sensitivity enhancer was investigated in detail. It is found that the developed immunoagglutination assay system is sensitive to dilution ratio of anti-T. gondii antibody as low as 1:5500. Analytical results of several specimens obtained using the developed technique are in satisfactory agreement with those given by the ELISA method, implying a promising alternative approach for detecting anti-T. gondii antibodies in the clinical diagnosis.  相似文献   

12.
Exogenous type D simian retroviruses (SRV/D) are prevalent in captive and feral populations of various macaque monkeys. Thus far, five subtypes of SRV/Ds have been reported, three of which (SRV-1, -2 and -3) have been molecularly characterized. Two SRV/D strains (N27 and T150) were isolated from seropositive cynomolgus macaques at the Tsukuba Primate Center (TPC) in Japan, showing clinical signs of SRV/D infection, including anemia and persistent unresponsive diarrhea. Electron microscopy demonstrated that both SRV/D isolates have a virion morphology typical of type D retrovirus. The SRV/D N27 and T150 isolates were essentially the same based on sequence analysis. From homology analysis of the entire gag sequence, the N27 isolate is closely related to the other known SRV/Ds but is distinct from the three molecularly characterized SRV/Ds. Thus, we have tentatively designated the N27 and T150 viruses isolated from TPC cynomolgus macaques as SRV/D-Tsukuba (SRV/D-T).  相似文献   

13.
HIV感染早期病毒p24蛋白的检测   总被引:1,自引:0,他引:1  
目的:建立敏感、特异的检测血清中HIV-p24蛋白的方法,作为HIV感染早期即窗口期的监测手段。方法:用纯化的p24蛋白免疫小鼠及家兔,获得单克隆及多克隆抗体,经DEAE-52阴离子交换柱纯化后,标记辣根过氧化物酶,建立ELISA双抗体夹心及间接双抗体夹心方法,检测HIV-p24蛋白。结果:包被单抗、标记多抗或包被多抗、标记单抗,均能特异地检出系列稀释的p24蛋白,包被混合单抗较包被多抗更敏感;经标记的抗种属抗体放大可明显提高检测的敏感性。结论:建立了敏感、特异的检测p24蛋白的双抗体夹心法,间接放大方法可检出50pg/mL的HIV-p24蛋白,检测敏感性与国际同类产品相似。  相似文献   

14.
We are developing a reference device to be used in the validation of immunohistochemical imaging of biomarkers by microscopy. The prototype device consists of p53 protein immobilized at various concentrations on a glass slide. The device is designed as a reference control to be used with assays that incorporate commercially available anti-p53 antibodies. p53 protein was characterized by mass spectrometry and covalently immobilized through amide linkage to the (3-aminopropyl)trietoxysilane-modified glass surface. This procedure is reproducible and provides a chemically stable product in high yield. The surface-bound protein was shown to be immunoreactive by its specific interaction with anti-p53 antibody (Ab) and detection by absorbance and fluorescence spectroscopy. Also, comparison was made with microscopic images of Ab-stained tissue samples, known to stain positive for p53. Further development will be required to establish accurate surface protein concentrations in the range required for specific clinical applications. (J Histochem Cytochem 58:1005–1014, 2010)  相似文献   

15.
The gag gene encoded protein, p24 of bovine leukemia virus (BLV), was cloned and expressed as thioredoxin-6xHis-p24 protein in Escherichia coli. The bacterial cells carrying plasmid pT7THis-p24 expressed the protein of 38 kDa that was detected by immunoblotting analysis using anti-p24 monoclonal antibodies and sera from BLV infected cattle and sheep. The purified p24 fusion protein was shown to be sensitive and specific for detection of BLV antibodies in the infected cattle.  相似文献   

16.
Legionella pneumophila peptidoglycan-associated lipoprotein (PAL) protein is an extremely conserved antigen among Legionella species. In this study, rabbit and rat anti-PAL immunoglobulin G antibodies were produced by immunization with purified, recombinant PAL (r-PAL) protein of L. pneumophila serogroup 1 and used as capture and detection antibodies in the PAL antigen-based enzyme-linked immunosorbent assay (ELISA) to detect urinary PAL antigen. Urine samples were obtained from rats experimentally infected with L. pneumophila serogroup 1. The PAL antigen was measured in urine samples of 40 infected and 40 uninfected rats. After choosing the cut-off value of 0.192, the sensitivity and specificity of the PAL antigen-based ELISA were 87.5 and 97.5 %, respectively. The results obtained by PAL antigen base ELISA were compared with those obtained by Biotest. The PAL antigen was detected efficiently by both of the assays and all of the control human urine samples were negative by the ELISA test. The PAL antigen-based ELISA assay was relatively simple to perform, precise, highly sensitive and specific, and reproducible. Based on our data the PAL antigen-based ELISA described here is the first indirect sandwich ELISA for urinary antigen detection which could easily be applied for diagnosis of Legionnaires disease.  相似文献   

17.
Screening assays for environmental mycotoxins in bulk samples currently use cytotoxicity in cell cultures, but their application to air particulate samples often lacks sensitivity and specificity for fungal spores. An assay based on inhibition of protein synthesis using translation of firefly luciferase in a rabbit reticulocyte system has been developed for the detection of trichothecene mycotoxins found in the spores of toxigenic fungi. Ethanol extracts of air particulates trapped on polycarbonate filters are ultrafiltered and applied at several dilutions to a translation reaction mixture. The activity of translated luciferase is measured directly in a luminometer, eliminating the need for radioisotopes and time-consuming sample processing. Parallel standard curves using a commercially available trichothecene provide for expression of the results in T-2 toxin equivalents per cubic meter of air. The assay can be completed in 2 h and is readily applicable to multiple samples. Comparison to the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide cytotoxicity assay indicates a 400-fold increase in sensitivity of trichothecene detection in addition to a much higher specificity for these toxins. Initial field testing indicates a strong correlation between the measured level of toxicity and the presence of toxigenic fungi detected with microbiological methods. In conclusion, this luciferase translation assay offers a rapid and highly sensitive and specific method for quantitative detection of trichothecene mycotoxin activity in air particulate samples.  相似文献   

18.
The effect of anti-p23,30, a rabbit antiserum to the human Ia-like antigen p23,30, on two macrophage-dependent T-cell functions, proliferation in response to soluble antigens, and production of lymphocyte mitogenic factor (LMF) was studied. T cells depleted of macrophages neither proliferate nor secrete LMF, and these functions are restored by addition of as few as 0.5% adherent macrophages. Treatment of macrophages with anti-p23,30 and C, however, abolishes their capacity to reconstitute these T-cell functions. In contrast, treatment of T cells with anti-p23,30 and C did not affect their capacity to respond in the presence of untreated adherent cells. We conclude that the presence of p23,30-bearing macrophages is critical for the expression of these antigen-induced T-cell responses.  相似文献   

19.
A sensitive, automated, and nonisotopic assay for protein-tyrosine kinases and phosphatases has been developed. The assay uses commercially available antiphosphotyrosine monoclonal antibodies and the recently developed particle concentration immunofluorescence immunoassay technology. The assay is specific for phosphotyrosine residues, can be performed faster, and is at least 100-fold more sensitive than the current standard filter type radioassay. Myelin basic protein and a synthetic peptide corresponding to the autophosphorylation site of p56lck performed equally well in the detection of p56lck kinase activity. Myelin basic protein phosphorylated on tyrosine residues by p56lck was successfully used as substrate in the detection of phosphatase activity and vanadate or molybdate were shown to inhibit the phosphatase activity. The assay is particularly useful for the rapid detection of enzyme activities in column fractions from biochemical procedures steps and also for screening of large numbers of potential inhibitors or activators of protein-tyrosine kinases and phosphatases.  相似文献   

20.
A simple, sensitive and stable ELISA (enzyme linked immunosorbent assay) was developed using rabbit antibody to fractionated Entamoeba histolytica antigen for the detection of copro antigen in the faeces of individuals with intestinal amoebiasis. In this test none of the healthy individuals, all trophozoite positive, 40% cyst passers and 6% individuals living in endemic area showed the presence of copro antigen. ELISA using polyclonal rabbit antibody could detect 1-5 trophozoites/well and 20-50 ng protein per well of NIH-200 strain of E. histolytica and the sensitivity of the test was comparable with that using monoclonal antibody. Cross reaction was observed only with E. invadens when faeces having other parasites were screened. The reagents of ELISA were stabilized and found to be stable for more than 6 months when stored at 4 degrees C.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号