首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Unexplained length-dependence of flexural rigidity and Young's modulus of microtubules is studied using an orthotropic elastic shell model. It is showed that vibration frequencies and buckling load predicted by the accurate orthotropic shell model are much lower than that given by the approximate isotropic beam model for shorter microtubules, although the two models give almost identical results for sufficiently long microtubules. It is this inaccuracy of the isotropic beam model used by all previous researchers that leads to reported lower flexural rigidity and Young's modulus for shorter microtubules. In particular, much lower shear modulus and circumferential Young's modulus, which only weaken flexural rigidity of shorter microtubules, are responsible for the observed length-dependence of the flexural rigidity. These results confirm that longitudinal Young's modulus of microtubules is length-independent, and the observed length-dependence of the flexural rigidity and Young's modulus is a result of strongly anisotropic elastic properties of microtubules which have a length-dependent weakening effect on flexural rigidity of shorter microtubules.  相似文献   

2.
Mammalian auditory outer hair cells generate high-frequency mechanical forces that enhance sound-induced displacements of the basilar membrane within the inner ear. It has been proposed that the resulting cell deformation is directed along the longitudinal axis of the cell by the cortical cytoskeleton. We have tested this proposal by making direct mechanical measurements on outer hair cells. The resultant stiffness modulus along the axis of whole dissociated cells was 3 x 10(-3) N/m, consistent with previously published values. The resultant axial and circumferential stiffness moduli for the cortical lattice were 5 x 10(-4) N/m and 3 x 10(-3) N/m, respectively. Thus the cortical lattice is a highly orthotropic structure. Its axial stiffness is small compared with that of the intact cell, but its circumferential stiffness is within the same order of magnitude. These measurements support the theory that the cortical cytoskeleton directs electrically driven length changes along the longitudinal axis of the cell. The Young's modulus of the circumferential filamentous components of the lattice were calculated to be 1 x 10(7) N/m2. The axial cross-links, believed to be a form of spectrin, were calculated to have a Young's modulus of 3 x 10(6) N/m2. Based on the measured values for the lattice and intact cell cortex, an estimate for the resultant stiffness modulus of the plasma membrane was estimated to be on the order of 10(-3) N/m. Thus, the plasma membrane appears to be relatively stiff and may be the dominant contributor to the axial stiffness of the intact cell.  相似文献   

3.
Rats use specialized tactile hairs on their snout, called vibrissae (whiskers), to explore their surroundings. Vibrissae have no sensors along their length, but instead transmit mechanical information to receptors embedded in the follicle at the vibrissa base. The transmission of mechanical information along the vibrissa, and thus the tactile information ultimately received by the nervous system, depends critically on the mechanical properties of the vibrissa. In particular, transmission depends on the bending stiffness of the vibrissa, defined as the product of the area moment of inertia and Young's modulus. To date, Young's modulus of the rat vibrissa has not been measured in a uniaxial tensile test. We performed tensile tests on 22 vibrissae cut into two halves: a tip-segment and a base-segment. The average Young's modulus across all segments was 3.34±1.48GPa. The average modulus of a tip-segment was 3.96±1.60GPa, and the average modulus of a base-segment was 2.90±1.25GPa. Thus, on average, tip-segments had a higher Young's modulus than base-segments. High-resolution images of vibrissae were taken to seek structural correlates of this trend. The fraction of the cross-sectional area occupied by the vibrissa cuticle was found to increase along the vibrissa length, and may be responsible for the increase in Young's modulus near the tip.  相似文献   

4.
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.  相似文献   

5.
This work consists of the validation of a novel approach to estimate the local anisotropic elastic constants of the bone extracellular matrix using nanoindentation. For this purpose, nanoindentation on two planes of material symmetry were analyzed and the resulting longitudinal elastic moduli compared to the moduli measured with a macroscopic tensile test. A combined lathe and tensile system was designed that allows machining and testing of cylindrical microspecimens of approximately 4mm in length and 300 microm in diameter. Three bovine specimens were tested in tension and their outer geometry and porosity assessed by synchrotron radiation microtomography. Based on the results of the traction test and the precise outer geometry, an apparent longitudinal Young's modulus was calculated. Results between 20.3 and 27.6 GPa were found that match with previously reported values for bovine compact bone. The same specimens were then characterized by nanoindentation on a transverse and longitudinal plane. A longitudinal Young's modulus for the bone matrix was then derived using the numerical scheme proposed by Swadener and Pharr and the fabric-elasticity relationship by Zysset and Curnier. Based on the matrix modulus and a power law effective volume fraction, an apparent longitudinal Young's modulus was predicted for each microspecimen. This alternative approach provided values between 19.9 and 30.0 GPa, demonstrating differences between 2% and 13% to the values provided by the initial tensile test. This study therefore raises confidence in our nanoindentation protocol of the bone extracellular matrix and supports the underlying hypotheses used to extract the anisotropic elastic constants.  相似文献   

6.
In order to determine the accuracy of measurements of Young's modulus of cancellous bone by conventional compression testing, two independent strain measurements were made simultaneously during non-destructive uniaxial compression to 0.8% strain of rectangular specimens (n = 18). Strain was measured by an extensometer attached to the compression anvils close to the specimen and by an optical system covering the central half of the specimens. Mean Young's modulus determined by the extensometer technique was 689 MPa, but was 871 MPa when determined by the optical technique (mean difference = 182 MPa, SED = 50 MPa, p less than 0.002). Uneven strain distribution due to lack of support of cut vertical trabeculae at the anvil-specimen interface is believed to be causing the underestimation of Young's modulus measured by the extensometer technique. The influence of friction at the specimen-anvil interface was studied by performing a finite element analysis. It is concluded that Young's modulus of specimens of the chosen geometry on average is underestimated by about 20% by conventional compressing testing. The underestimation seems not to be dependent upon specimen density.  相似文献   

7.
A linear incremental finite element model is used to analyze the mechanical behavior of the left ventricle. The ventricle is treated as a heterogeneous, non-linearly elastic, isotropic, thick-walled solid of revolution. A new triaxial constitutive relation for the myocardium is presented which exhibits the observed exponential length-passive tension behavior of left ventricular papillary muscle in the limit of uniaxial tension. This triaxial relation contains three parameters: (a) a “small strain” Young's modulus, (b) a Poisson's ratio, and (c) a parameter which characterizes the nonlinear aspect of the elastic behavior of heart muscle. The inner third and outer two-thirds of the ventricular wall are assumed to have small strain Young's moduli of 30 and 60 g/cm2, respectively. The Poisson's ratio is assumed to be equal to 0.49 throughout the ventricular wall. In general, the results of this study indicate that while a linearly elastic model for the ventricle may be adequate in terms of predicting pressure-volume relationships, a linear model may have serious limitations with regard to predicting fiber elongation within the ventricular wall. For example, volumes and midwall equatorial circumferential strains predicted by the linear and nonlinear models considered in this study differ by approximately 20 and 90%, respectively, at a transmural pressure of 12 cm H2O.  相似文献   

8.
Ionic Polymer-Metal Composite (IPMC) can work as an actuator by applying a few voltages.A thick IPMC actuator,whereNafion-117 membrane was synthesized with polypyrrole/alumina composite filler,was analyzed to verify the equivalent beamand equivalent bimorph beam models.The blocking force and tip displacement of the IPMC actuator were measured with a DCpower supply and Young’s modulus of the IPMC strip was measured by bending and tensile tests respectively.The calculatedmaximum tip displacement and the Young’s modulus by the equivalent beam model were almost identical to the correspondingmeasured data.Finite element analysis with thermal analogy technique was utilized in the equivalent bimorph beam model tonumerically reproduce the force-displacement relationship of the IPMC actuator.The results by the equivalent bimorph beammodel agreed well with the force-displacement relationship acquired by the measured data.It is confirmed that the equivalentbeam and equivalent bimorph beam models are practically and effectively suitable for predicting the tip displacement,blockingforce and Young’s modulus of IPMC actuators with different thickness and different composite of ionic polymer membrane.  相似文献   

9.
At mechanical equilibrium, articular cartilage is usually characterized as an isotropic elastic material with no interstitial fluid flow. In this study, the equilibrium properties (Young's modulus, aggregate modulus and Poisson's ratio) of bovine humeral, patellar and femoral cartilage specimens (n=26) were investigated using unconfined compression, confined compression, and indentation tests. Optical measurements of the Poisson's ratio of cartilage were also carried out. Mean values of the Young's modulus (assessed from the unconfined compression test) were 0.80+/-0.33, 0.57+/-0.17 and 0.31+/-0.18MPa and of the Poisson's ratio (assessed from the optical test) 0.15+/-0.06, 0.16+/-0.05 and 0.21+/-0.05 for humeral, patellar, and femoral cartilages, respectively. The indentation tests showed 30-79% (p<0.01) higher Young's modulus values than the unconfined compression tests. In indentation, values of the Young's modulus were independent of the indenter diameter only in the humeral cartilage. The mean values of the Poisson's ratio, obtained indirectly using the mathematical relation between the Young's modulus and the aggregate modulus in isotropic material, were 0.16+/-0.06, 0.21+/-0.05, and 0.26+/-0.08 for humeral, patellar, and femoral cartilages, respectively. We conclude that the values of the elastic parameters of the cartilage are dependent on the measurement technique in use. Based on the similar values of Poisson's ratios, as determined directly or indirectly, the equilibrium response of articular cartilage under unconfined and confined compression is satisfactorily described by the isotropic elastic model. However, values of the isotropic Young's modulus obtained from the in situ indentation tests are higher than those obtained from the in vitro unconfined or confined compression tests and may depend on the indenter size in use.  相似文献   

10.
The aim of this study was to examine the mechanical behavior of the colon using tensile tests under different loading speeds.Specimens were taken from different locations of the colonic frame from refrigerated cadavers. The specimens were submitted to uniaxial tensile tests after preconditioning using a dynamic load (1 m/s), intermediate load (10 cm/s), and quasi-static load (1 cm/s).A total of 336 specimens taken from 28 colons were tested. The stress-strain analysis for longitudinal specimens indicated a Young’s modulus of 3.17 ± 2.05 MPa under dynamic loading (1 m/s), 1.74 ± 1.15 MPa under intermediate loading (10 cm/s), and 1.76 ± 1.21 MPa under quasi-static loading (1 cm/s) with p < 0.001. For the circumferential specimen, the stress-strain curves indicated a Young’s modulus of 3.15 ± 1.73 MPa under dynamic loading (1 m/s), 2.14 ± 1.3 MPa under intermediate loading (10 cm/s), and 0.63 ± 1.25 MPa under quasi-static loading (1 cm/s) with p < 0.001. The curves reveal two types of behaviors of the colon: fast break behavior at high speed traction (1 m/s) and a lower break behavior for lower speeds (10 cm/s and 1 cm/s). The circumferential orientation required greater levels of stress and strain to obtain lesions than the longitudinal orientation. The presence of taeniae coli changed the mechanical response during low-speed loading.Colonic mechanical behavior varies with loading speeds with two different types of mechanical behavior: more fragile behavior under dynamic load and more elastic behavior for quasi-static load.  相似文献   

11.
The viscoelastic properties of porcine carotid tissue are investigated in this work. Experimental uniaxial stress relaxation tests along the longitudinal and circumferential directions of the vessel were performed for carotid strips extracted from 10 vessels. Directional and local differences - distal versus proximal position - in the tissue behavior were investigated. The experimental tests reveal a highly anisotropic, non-linear viscoelastic response and local dependence of the samples. The carotid artery shows anisotropic relaxation behavior for both proximal and distal samples. The highest stress relaxation was found in the circumferential tensile test for the highest applied strain at the distal position. For the circumferential direction, the relaxation stress was higher than in the longitudinal being at its highest in the distal position. These facts show that the stress relaxation is higher in the distal than in the proximal position. However, there are no differences between both positions in the longitudinal direction. In addition, a constitutive law that takes into account the fundamental features, including non-linear viscoelasticity, of the arterial tissue is proposed. The present results are correlated with the purely elastic response and the microstructural analysis of the tissue by means of histological quantification presented in a previous study.  相似文献   

12.
The epicardial coronary arteries experience significant torsion in the axial direction due to changes in the shape of the heart during the cardiac cycle. The objective of this study was to determine the torsional mechanical properties of the coronary arteries under various circumferential and longitudinal loadings. The coronary artery was treated as a two-layer composite vessel consisting of intima-medial and adventitial layers, and the shear modulus of each layer was determined. Eight porcine hearts were obtained at a local abattoir, and their right coronary and left anterior descending arteries were isolated and tested in vitro with a triaxial torsion machine (inflation, longitudinal stretch, and circumferential twist). After the intact vessel was tested, the adventitia was dissected away, leaving an intact media that was then tested under identical triaxial loading conditions. We proposed a biomechanical analysis to compute the shear modulus of the adventitia from the measured shear moduli of the intact vessel and the media. To validate our predictions, we used four additional hearts in which the shear modulus of the adventitia was measured after dissection of media. Our results show that the shear modulus does not depend on the shear stress or strain but varies linearly with circumferential and longitudinal stresses and in a nonlinear way with the corresponding strains. Furthermore, we found that the shear modulus of the adventitia is larger than that of the intact vessel, which is larger than the vessel media. These results may have important implications for baroreceptor sensitivity, circulation of the vasa vasorum, and coronary dissection.  相似文献   

13.
Meniscal attachments are ligamentous tissues anchoring the menisci to the underlying subchondral bone. Currently little is known about the behavior of meniscal attachments, with only a few studies quantitatively documenting their properties. The objective of this study was to quantify and compare the tensile mechanical properties of human meniscal attachments in the transverse direction, curve fit experimental Cauchy stress-stretch data to evaluate the hyperelastic behavior, and couple these results with previously obtained longitudinal data to generate a more complete constitutive model. Meniscal attachment specimens were tested using a uniaxial tension test with the collagen fibers oriented perpendicular to the loading axis. Tests were run until failure and load-optical displacement data was recorded for each test. The medial posterior attachment was shown to have a significantly greater elastic modulus (6.42±0.78 MPa) and ultimate stress (1.73±0.32 MPa) when compared to the other three attachments. The Mooney-Rivlin material model was selected as the best fit for the transverse data and used in conjunction with the longitudinal data. A novel computational approach to determining the transition point between the toe and linear regions is presented for the hyperelastic stress-stretch curves. Results from piece-wise non-linear longitudinal curve fitting correlate well with previous linear elastic and SEM findings. These data can be used to advance the design of meniscal replacements and improve knee joint finite element models.  相似文献   

14.
Costal cartilage (CC) is one of the load-bearing tissues of the rib cage. Literature on material characterisation of the CC is limited. Atomic force microscopy (AFM) has been extremely successful in characterising the elastic properties of soft biomaterials such as articular cartilage and hydrogels, which are often the material of choice for cartilage models. But AFM data on CC are absent in the literature. In this study, AFM indentations using spherical beaded tips were performed on human CC to isolate the mechanical properties. A novel method was developed for modelling the relaxation indentation experiments based on Fung's quasi-linear viscoelasticity and a continuous relaxation spectrum. This particular model has been popular for uniaxial compression test data analysis. Using the model, the mean Young's modulus of CC was found to be about 2.17, 4.11 and 5.49?MPa for three specimens. A large variation of modulus was observed over the tissue. Also, the modulus values decreased with distance from the costochondral junction.  相似文献   

15.
The objective of this study was to examine the dependence of the elastic properties of cortical bone as a transversely isotropic material on its porosity. The longitudinal Young's modulus, transverse Young's modulus, longitudinal shear modulus, transverse shear modulus, and longitudinal Poisson's ratio of cortical bone were determined from eighteen groups of longitudinal and transverse specimens using tensile and torsional tests on a servo-hydraulic material testing system. These cylindrical waisted specimens of cortical bone were harvested from the middle diaphysis of three pairs of human femora. The porosity of these specimens was assessed by means of histology. Our study demonstrated that the longitudinal Young's and shear moduli of human femoral cortical bone were significantly (p<0.01) negatively correlated with the porosity of cortical bone. Conversely, the elastic properties in the transverse direction did not have statistically significant correlations with the porosity of cortical bone. As a result, the transverse elastic properties of cortical bone were less sensitive to changes in porosity than those in the longitudinal direction. Additionally, the anisotropic ratios of cortical bone elasticity were found to be significantly (p<0.01) negatively correlated with its porosity, indicating that cortical bone tended to become more isotropic when its porosity increased. These results may help a number of researchers develop more accurate micromechanics models of cortical bone.  相似文献   

16.
Although bacterial cells are known to experience large forces from osmotic pressure differences and their local microenvironment, quantitative measurements of the mechanical properties of growing bacterial cells have been limited. We provide an experimental approach and theoretical framework for measuring the mechanical properties of live bacteria. We encapsulated bacteria in agarose with a user-defined stiffness, measured the growth rate of individual cells and fit data to a thin-shell mechanical model to extract the effective longitudinal Young's modulus of the cell envelope of Escherichia coli (50-150 MPa), Bacillus subtilis (100-200 MPa) and Pseudomonas aeruginosa (100-200 MPa). Our data provide estimates of cell wall stiffness similar to values obtained via the more labour-intensive technique of atomic force microscopy. To address physiological perturbations that produce changes in cellular mechanical properties, we tested the effect of A22-induced MreB depolymerization on the stiffness of E. coli. The effective longitudinal Young's modulus was not significantly affected by A22 treatment at short time scales, supporting a model in which the interactions between MreB and the cell wall persist on the same time scale as growth. Our technique therefore enables the rapid determination of how changes in genotype and biochemistry affect the mechanical properties of the bacterial envelope.  相似文献   

17.
Force-elongation responses of the human abdominal wall in the linea alba region were determined by tensile tests in which the linea alba was seen to exhibit a nonlinear elastic, anisotropic behavior as is frequently observed in soft biological tissues. In addition, the geometry of the abdominal wall was determined, based on MRI data. The geometry can be specified by principal radii of curvature in longitudinal of approximately 470 mm and in the transverse direction of about 200 mm. The determined radii agree with values found in other studies. Mechanical stresses, deformations and abdominal pressures for load cases above 6% elongation can be related using Laplace's formula and our constitutive and geometrical findings. Results from uni- and biaxial tensile tests can thus be compared using this model. Calculations confirm that abdominal pressures of approximately 20 kPa correspond to related biaxial forces of about 3.4N/mm in the transverse and 1.5 N/mm in the longitudinal direction. Young's moduli can be calculated with respect to the uniaxial as well as the biaxial loading. At these physiological loadings, a compliance ratio of about 2:1 between the longitudinal and transversal directions is found. Young's moduli of about 50 kPa occur in transversal direction and of about 20 kPa in longitudinal direction at transverse and longitudinal strains both in the order of 6%. These findings coincide with results from other investigations in which the properties of the abdominal wall have been examined.  相似文献   

18.
The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of the water molecules in the tissue is correlated with its biomechanical property. Therefore, magnetic resonance imaging (MRI) represents a potential approach to assess the biophysical property of the engineered cartilage. In this study, we test the hypothesis that quantitative MRI can be used as a noninvasive assessment method to assess the biophysical property of the engineered cartilage. To reconstruct a model of cartilaginous tissue, chondrocytes harvested from the humeral head of calves were embedded in an agarose gel and cultured in vitro up to 4 weeks. Equilibrium Young's moduli were determined from the stress relaxation tests. After mechanical testing, MRI-derived parameters (longitudinal relaxation time T1, transverse relaxation time T2, and water self-diffusion coefficient D) were measured. The equilibrium Young's modulus of the engineered cartilage showed a tendency to increase with an increase in the culture time, whereas T1 and D decreased. Based on a regression analysis, T1 and D showed a strong correlation with the equilibrium Young's modulus. The results showed that T1 and D values derived from the MRI measurements could be used to noninvasively monitor the biophysical properties of the engineered cartilage.  相似文献   

19.
In this paper, mechanical properties of the anterior malleolar ligament (AML) of human middle ear were studied through the uniaxial tensile, stress relaxation and failure tests. The digital image correlation (DIC) method was used to assess the boundary effect in experiments and calculate the strain on specimens. The constitutive behavior of the AML was described by a transversely isotropic hyperelastic model which consists of a first-order Ogden model augmented by a I (4)-type reinforcing term. The material parameters of the model were estimated and the viscoelasticity of the AML was illustrated by hysteresis phenomena and stress relaxation function. The mechanical strength of the AML was obtained through the failure test and the mean ultimate stress and stretch ratio were measured as 1.05 MPa and 1.51, respectively. Finally, a linear Young's modulus-stress relationship of the AML was derived based on constitutive equation of the AML within a stress range of 0-0.5 MPa.  相似文献   

20.
The annulus fibrosus (AF) of the intervertebral disk undergoes large and multidirectional stresses and strains. Uniaxial tensile tests are limited for measuring AF material properties, because freely contracting edges can prevent fiber stretch and are not representative of in situ boundary conditions. The objectives of this study were to measure human AF biaxial tensile mechanics and to apply and validate a constitutive model to determine material properties. Biaxial tensile tests were performed on samples oriented along the circumferential–axial and the radial–axial directions. Data were fit to a structurally motivated anisotropic hyperelastic model composed of isotropic extra-fibrillar matrix, nonlinear fibers, and fiber–matrix interactions (FMI) normal to the fibers. The validated model was used to simulate shear and uniaxial tensile behavior, to investigate AF structure–function, and to quantify the effect of degeneration. The biaxial stress–strain response was described well by the model (R 2?>?0.9). The model showed that the parameters for fiber nonlinearity and the normal FMI correlated with degeneration, resulting in an elongated toe-region and lower stiffness with degeneration. The model simulations in shear and uniaxial tension successfully matched previously published circumferential direction Young’s modulus, provided an explanation for the low values in previously published axial direction Young’s modulus, and was able to simulate shear mechanics. The normal FMI were important contributors to stress and changed with degeneration, therefore, their microstructural and compositional source should be investigated. Finally, the biaxial mechanical data and constitutive model can be incorporated into a disk finite element model to provide improved quantification of disk mechanics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号