1.
A simple and sensitive liquid chromatography-mass spectrometry method is described for the determination of nicardipine in human plasma. Chromatographic separation of the analyte was achieved on a C(18) column using a mobile phase of methanol, water and formic acid (320:180:0.4, v/v/v). Selected ion monitoring (SIM) in positive mode was used for analyte quantification at m/z 480.2 for nicardipine and m/z 256.4 for diphenhydramine. The run time was less than 5 min. The linearity over the concentration range of 0.05-20.0 ng/ml for nicardipine was obtained and the lower limit of quantification was 0.05 ng/ml. For each level of QC samples, inter-day and intra-day precisions (R.S.D.) were < or =9.3 and 11.1%, respectively, and accuracy (RE) was +/-4.9%. The present LC-MS method was successfully applied in the pharmacokinetic studies of nicardipine hydrochloride delayed-release tablets in two formulations after oral administration to healthy volunteers.  相似文献   

2.
A sensitive and selective liquid chromatographic procedure using fluorimetric detection was developed to quantify dextromethorphan (DTM), 3-methoxymorphinan (3MM), dextrorphan (DT), 3-hydroxymorphinan (3OH) and two internal standards, codeine (COD) and ethylmorphine (ETM), in urine. Precision and accuracy of the assay were determined over a concentration range of 5–3200 ng/ml urine for DTM, 5–400 ng/ml urine for 3MM, 400–40 000 ng/ml urine for DT and 200–16 000 ng/ml urine for 3OH, by assaying freshly prepared calibration standards and replicates of six quality control (QC) samples on separate days. All of the inter-day and intra-day coefficients of variation (C.V.s) were less than 20% except for a low QC for 3MM. The inter-day and intra-day accuracies were less than 20% for the low QCs, less than 15% for the medium QCs and less than 12% for the high QCs, for all compounds. The limit of quantification (LOQ) was 2 ng/ml urine for DTM and 3MM, 250 ng/ml urine for DT, and 100 ng/ml urine for 3OH. Absolute recovery was 76% for DTM, 74% for 3MM, 77% for DT, 46% for 3OH, 73% for ETM, and 57% for COD. The frequency distribution of the CYP2D6 metabolic ratio (DTM/DT) illustrated a bimodal distribution whereas, the CYP3A metabolic ratio (DTM/3MM) exhibited a unimodal distribution in overnight urine samples of volunteers who ingested 30 mg dextromethorphan hydrobromide. The CYP2D6 metabolic ratio significantly correlated with 3MM/3OH (r=0.82) and DTM/3OH (r=0.95) but did not correlate with the CYP3A metabolic ratio (r=0.27).  相似文献   

3.
This method describes the determination of propiomazine by direct injection of rat plasma into a chromatography system based on coupled reversed-phase columns. An extraction column, packed with porous silica particles with covalent-bound 1-acid glycoprotein (AGP), was used to separate the plasma proteins from the analyte. After isolation the analyte was transferred to the analytical column for separation and detection. Propiomazine was detected by an electrochemical detector and the limit of quantification was 2.0 ng/ml (100 pg injected). The absolute recovery was 80.9±2.4% at 9.0 ng/ml level. The inter-day and intra-day precision was 10.9% (5.6 ng/ml) and 2.8% (9.0 ng/ml), respectively.  相似文献   

4.
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies.  相似文献   

5.
A liquid chromatography tandem mass spectrometry assay for serum testosterone (T) and trideuterated testosterone (d(3)T) was developed in order to support clinical research studies that determine the pharmacokinetics, production rate, and clearance of testosterone by administration of trideuterated testosterone. After adding 19-nortestosterone as the internal standard (I.S.), sodium acetate buffer, and ether, to a serum aliquot, the mixture was shaken and centrifuged, and the ether was dried. The extract was reconstituted in methanol and 15 microl was injected into a liquid chromatograph equipped with an autosampler and Applied Biosystems-Sciex API 300 triple quadrupole mass spectrometer operated in the positive ion mode. T, d(3)T, and I.S. were monitored with transitions m/z 289 to m/z 97, m/z 292 to m/z 97, and m/z 275 to m/z 109, respectively. The two calibration curves were linear over the entire measurement range of 0-20 ng/ml for T and 0-2.0 ng/ml for d(3)T. The LOQs for T and d(3)T were 0.5 ng/ml and 0.05 ng/ml. The recoveries for T and d(3)T were 91.5 and 96.4%. For T at 1.25 ng/ml and 4.0 ng/ml, the intra-day precision (RSD, %) was 3.9 and 4.3% and intra-day accuracy 0.01 and 4.5%, respectively. The inter-day precision at these levels was 5.3 and 5.4% and inter-day accuracy was 1.9 and 0.3%. For d(3)T at 0.125 ng/ml and 0.4 ng/ml, the intra-day precision (RSD, %) was 2.8 and 8.3% and intra-day accuracy was 1.8 and 5.6%. The inter-day precision at these levels was 10.0 and 7.6% and inter-day accuracy was 5.7 and 3.4%. The concentrations of T in the 38 healthy subjects ranged from 2.5 to 14.0 ng/ml (mean 6.2 ng/ml).  相似文献   

6.
A simple determination method of amphetamine (AP) and methamphetamine (MA) in biological materials was developed using on-column derivatization and gas chromatography-mass spectrometry (GC-MS). AP and MA in biological materials were adsorbed on the surface of Extrelut and then extracted and derivatized simultaneously on the Extrelut column. AP and MA were derivatized to the N-propoxycarbonyl derivatives using propylchloroformate. Pentadeuterated MA was used as an internal standard. The recoveries of AP and MA from urine were 88.2 and 92.5%, and those from blood were 89.7 and 90.3%, respectively. The calibration curves showed linearity in the range of 12.5-2000 ng/ml (ng/g) for AP and MA in urine and blood, and 0.25-20 ng/mg in hair. When urine samples containing two different concentrations (200 and 1000 ng/ml) of AP and MA, blood samples containing two different concentrations (200 and 1000 ng/g) of AP and MA, hair samples containing two different concentrations (0.5 and 5.0 ng/mg) of AP and MA, the coefficients of variation of intra-day and inter-day were 0.68-3.60% in urine, 0.42-4.58% in blood, and 1.20-13.1% in hair. Furthermore, this proposed method was applied to a medico-legal case of MA intoxication.  相似文献   

7.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

8.
A rugged and robust liquid chromatographic tandem mass spectrometric (LC-MS/MS) method utilizing dried blood spots (DBS) was developed and validated for the analysis of posaconazole in human whole blood. Posaconazole fortified blood samples were spotted (15 μL) onto Ahlstrom Alh-226 DBS cards and dried for at least 2h. Punched spots were then extracted by using a mixture of acetonitrile and water containing stable labeled internal standard (IS). Posaconazole and its IS were separated from endogenous matrix components on a Kinetex? C18 column under gradient conditions with a mobile phase A consisting of 0.1% formic acid and a mobile phase B consisting of 0.1% formic acid in acetonitrile/methanol (70/30, v/v). The analyte and IS were detected using a Sciex API 4000 triple quadrupole LC-MS/MS system equipped with a TurboIonSpray? source operated in the positive ion mode. The assay was linear over the concentration range of 5-5000 ng/mL. The inter-run accuracy and precision of the assay were -1.8% to 0.8% and 4.0% to 10.4%, respectively. Additional assessments unique to DBS were investigated including sample spot homogeneity, spot volume, and hematocrit. Blood spot homogeneity was maintained and accurate and precise quantitation results were obtained when using a blood spot volume of between 15 and 35 μL. Human blood samples with hematocrit values ranging between 25% and 41% gave acceptable quantitation results. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible.  相似文献   

9.
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the simultaneous analysis of hydrocodone (HYC) and its metabolite hydromorphone (HYM) in human plasma. A robotic liquid handler and a 96-channel liquid handling workstation were used to aliquot samples, to add internal standard (I.S.), and to extract analytes of interest. A 96-well mixed-mode solid-phase cartridge plate was used to extract the analytes and I.S. The chromatographic separation was on a silica column (50 x 3 mm, 5-microm) with a mobile phase consisting of acetonitrile, water and trifluoroacetic acid (TFA) (92:8:0.01, v/v). The run time for each injection was 2.5 min with the retention times of approximately 2.1 and 2.2 min for HYC and HYM, respectively. The tandem mass spectrometric detection was by monitoring singly charged precursor-->product ion transition 300-->199 (m/z) for HYC, and 28-->185 (m/z) for HYM. The validated calibration curve range was 0.100-100 ng/ml, based on a plasma volume of 0.3 ml. The correlation coefficients were greater than or equal to 0.9996 for both HYC and HYM. The low limit of quantitation (LLOQ) was 0.100 ng/ml for both HYC and HYM with signal-to-noise ratio (S/N) of 50 and 10. respectively. The deuterated analytes, used as internal standards, were monitored at mass transitions 303-->199 (m/z) for HYC-d3 and 289-->185 (m/z) for HYM-d3. The inter-day (n= 17) precision of the quality control (QC) samples were < or = 3.5% RSD (relative standard deviation) for HYC and < or = 4.7% RSD for HYM, respectively. The inter-day accuracy of the QC samples were < or = 2.1% RE (relative error) for HYC and < or = 1.8% RE for HYM. The intra-day (n=6) precision and accuracy of the QC samples were < or = 2.6% RSD and < or = 3.0% RE for HYC, and < or = 4.7% RSD and < or = 2.4% RE for HYM. There was no significant deviation from the nominal values after a 5-fold dilution of high concentration QC samples by blank matrix. The QC samples were stable when kept at room temperature for 24-h or experienced three freeze-thaw cycles. The extraction recoveries were 86% for HYC and 78% for HYM. No detectable carryover was observed when a blank sample was injected immediately after a 2500 ng/ml sample that was 25-fold more concentrated than the upper limit of quantitation (ULOQ).  相似文献   

10.
A sensitive and specific liquid chromatographic-tandem mass spectrometric method is described for the determination of cefaclor in human plasma. The plasma samples were treated by two sample preparation procedures, i.e. protein precipitation (PPT) and solid-phase extraction (SPE). The pretreated samples were analyzed on a C(18) HPLC column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization (ESI) was employed as the ionization source. The analyte and internal standard ampicillin (for PPT) or cefetamet (for SPE) were detected by use of selected reaction monitoring (SRM) mode. The lower limit of quantitation obtained as a result of the PPT procedure was 100 ng/ml. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 12% for cefaclor. The accuracy as determined from QC samples was within +/-3% for the analyte. The SPE procedure could provide the lower limit of quantitation of 2 ng/ml. The precision and accuracy were measured to be below 7.1% and between -3.6% and 1.1%, respectively, for all QC samples. The method was applied for the evaluation of the pharmacokinetic profiles of cefaclor sustained-release formulation.  相似文献   

11.
A high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) procedure for the simultaneous determination of diazepam from avizafone, atropine and pralidoxime in human plasma is described. Sample pretreatment consisted of protein precipitation from 100microl of plasma using acetonitrile containing the internal standard (diazepam D5). Chromatographic separation was performed on a X-Terra MS C8 column (100mmx2.1mm, i.d. 3.5microm), with a quick stepwise gradient using a formate buffer (pH 3, 2mM) and acetonitrile at a flow rate of 0.2ml/min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges of 1-500ng/ml for diazepam, 0.25-50ng/ml for atropine and 5-1000ng/ml for pralidoxime. The coefficients of variation were always <15% for both intra-day and inter-day precision for each analyte. Mean accuracies were also within +/-15%. This method has been successfully applied to a pharmacokinetic study of the three compounds after intramuscular injection of an avizafone-atropine-pralidoxime combination, in healthy subjects.  相似文献   

12.
A sensitive and selective reversed-phase liquid chromatographic assay for tenofovir in human plasma has been developed and validated. Tenofovir was isolated from a 200 microl plasma sample using protein precipitation with trichloroacetic acid. The fluorescent 1,N(6)-etheno derivative is formed at 98 degrees C in the buffered extract with chloroacetaldehyde. This derivative was analysed using gradient ion-pair liquid chromatography and fluorescence detection at 254 nm for excitation and 425 nm for emission. In the evaluated concentration range (20-1000 ng/ml), the intra-day precision was 4% and the inter-day precision was 5-6%. An accuracy of between 97 and 110% was determined. The lower limit of quantification was 20 ng/ml with an inter-day precision of 11%, an intra-day precision of 12% and an accuracy of 103%. The assay is subject to interference from co-administered abacavir. The usefulness of the assay was demonstrated for samples obtained from an HIV-infected patient treated with tenofovir.  相似文献   

13.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

14.
A method based on LC-MS-MS is described for the determination of methyldopa in human plasma using dopa-phenyl-D3 as the internal standard. The method has a chromatographic run time of 5.5 min and was linear in the range of 20-5000 ng/ml. The limit of quantitation was 20 ng/ml, the intra-day precisions were 7.3, 5.4 and 4.3% and the intra-day accuracies were -8.0, -1.3 and -2.0% for 30, 600 and 3000 ng/ml, respectively. The inter-day precisions were 7.7, 0.5 and 0.7% and the inter-day accuracies were 0.2, -1.1 and -2.3%, respectively, for the above concentrations. This method was employed in a bioequivalence study of two tablet formulations of methyldopa.  相似文献   

15.
An HPLC system using a simple liquid-liquid extraction and HPLC with UV detection has been validated to determine tramadol concentration in human plasma. The method developed was selective and linear for concentrations ranging from 10 to 2000 ng/ml with average recovery of 98.63%. The limit of quantitation (LOQ) was 10 ng/ml and the percentage recovery of the internal standard phenacetin was 76.51%. The intra-day accuracy ranged from 87.55 to 105.99% and the inter-day accuracy, 93.44 to 98.43% for tramadol. Good precision (5.32 and 6.67% for intra- and inter-day, respectively) was obtained at LOQ. The method has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

16.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

17.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

18.
An HPLC system using solid-phase extraction and HPLC with UV detection has been validated in order to determine tramadol and o-desmethyltramadol (M1) concentrations in human plasma. The method developed was selective and linear for concentrations ranging from 50 to 3500 ng/ml (tramadol) and 50 to 500 ng/ml (M1) with mean recoveries of 94.36±12.53% and 93.52±7.88%, respectively. Limit of quantitation (LOQ) was 50 ng/ml. For tramadol, the intra-day accuracy ranged from 95.48 to 114.64% and the inter-day accuracy, 97.21 to 103.24%. Good precision (0.51 and 18.32% for intra- and inter-day, respectively) was obtained at LOQ. The system has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

19.
A high-performance liquid chromatography (LC-MS) method has been developed and validated for the determination of dexamethasone in dried blood spot (DBS) samples. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30μl blood spots on specimen collection cards. An 8mm disc was cut from the DBS sample and extracted using a combination of methanol: water (70:30, v/v) containing the internal standard, triamcinolone acetonide. Extracts were centrifuged and chromatographic separation was achieved using a Zorbax Eclipse Plus C18 column using gradient elution with a mobile phase of acetonitrile and water with formic acid at a flow rate of 0.2ml/min. LC-MS detection was conducted with single ion monitoring using target ions at m/z 393.1 for dexamethasone and 435.1 for the internal standard. The developed method was linear within the tested calibration range of 15-800ng/ml. The overall extraction recovery of dexamethasone from DBS samples was 99.3% (94.3-105.7%). The accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤15% at all concentrations. Factors with potential to affect drug quantification measurements such as blood haematocrit, the volume of blood applied onto the collection card and spotting device were investigated. Although a haematocrit related effect was apparent, the assay accuracy and precision values remained within the 15% variability limit with fluctuations in haematocrit of ±5%. Variations in the volume of blood spotted did not appear to affect the performance of the developed assay. Similar observations were made regarding the spotting device used. The methodology has been applied to determine levels of dexamethasone in DBS samples collected from premature neonates. The measured concentrations were successfully evaluated using a simple 1-compartment pharmacokinetic model. Requiring only a microvolume (30μl) blood sample for analysis, the developed assay is particularly suited to pharmacokinetic studies involving paediatric populations.  相似文献   

20.
A simple and sensitive column-switching HPLC method has been developed for the simultaneous determination of NK-104 (HMG–CoA reductase inhibitor) and its lactone in human and dog plasma. Plasma sample was extracted with methyl tert-butyl ether and then the extract was subjected to methylation with diazomethane to prevent the mutual conversion between NK-104 and its lactone. The extract was injected into the column-switching HPLC system. The calibration curves of NK-104 and NK-104 lactone were linear over the ranges 0.5 to 100 ng/ml for human plasma samples and 0.5 to 500 ng/ml for dog plasma, respectively. The intra-day and inter-day C.V. values of these analytes were less than 13.3%. The intra-day and inter-day accuracies of these analytes were between −14.0 and 6.5%. The proposed method has been applied to plasma samples obtained after oral administration of a single 2 mg dose of NK-104 to volunteers.  相似文献   