首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Normal and modified urinary nucleosides represent potential biomarkers for cancer diagnosis. To selectively extract modified nucleosides, we developed a molecularly imprinted polymer (MIP) of 5-methyluridine as selective material for molecularly imprinted solid-phase extraction (MISPE). The MIPs were obtained from vinyl-phenylboronate ester derivative of the template, acrylamide and pentaerythritol triacrylate co-polymer, and were tested in batch and cartridge experiments with aqueous samples. Our results indicated that the imprinted polymer was selective for pyrimidine nucleosides with a K(d) and a B(max) of 46 microM and 18 micromol/g, respectively. Finally, a MISPE of the most common pyrimidine nucleoside cancer markers in urine sample was realized.  相似文献   

2.
The evaluation of molecularly imprinted polymers (MIPs) as selective sorbents for the solid-phase extraction of sildenafil and its principal metabolite, desmethylsildenafil, was investigated. Two MIPs were synthesised using structural analogues of sildenafil as templates, and a comparison of the performance of the two MIP sorbents in organic and aqueous media was performed. Additionally, the feasibility of applying molecularly imprinted solid-phase extraction (MISPE) to the clean-up of plasma samples containing sildenafil and desmethylsildenafil was investigated. A preliminary, quantitative MISPE for the determination of both compounds in plasma was also performed. The results showed that the MIPs used for the selective extraction of sildenafil gave better compound recovery when aqueous samples were used in comparison to organic-based samples. A preliminary, quantitative MISPE of sildenafil and desmethylsildenafil indicated that the imprinted materials could be used successfully as SPE sorbents for sample pre-treatment for the determination of sildenafil, and related compounds, in plasma.  相似文献   

3.
Group-selective molecularly imprinted polymers (MIPs) made from sulfonamides (SAs) using functional monomer methacrylic acid (MAA) were synthesized. The derived molecularly imprinted solid-phase extraction (MISPE) cartridges were developed for the purification and enrichment of aquatic products. The optimum template molecule and the ratio of the functional monomer to the template for obtaining group selectivity to SAs were sulfadimethoxine (SDM) and 4:1, respectively. The MIPs were characterized by Brunauer-Emmett-Teller (BET), scatchard plot, and chromatography analysis, all of which demonstrate better chromatographic behavior and group-selectivity of MIPs for SAs compared with those of corresponding NIPs. The extraction conditions of MISPE for six SAs were optimized; the method precision and accuracy were satisfactory for the fish and shrimp samples at 0.05, 0.1, and 0.2 mg kg(-1) spiked levels. Recoveries ranging from 85.5% to 106.1% (RSD, 1.2-7.0%, n=3) were achieved. The limits of detection (S/N=3) and quantitation (S/N=10) in the shrimp and fish samples were achieved from 8.4 to 10.9 μg kg(-1) and from 22.4 to 27.7 μg kg(-1), respectively. Therefore, the obtained MIPs and MISPE can be employed for the enrichment and clean-up of SAs. This paper presents a new analytical method which enables the simultaneous determination and quantification of SAs in aquaculture products.  相似文献   

4.
This study investigates matrix effects on a molecularly imprinted solid-phase extraction (MISPE) method developed for the clean-up of diphenyl phosphate (a hydrolysis product of the commonly used flame retardant and plasticizer, triphenyl phosphate) in urine samples. The influence of potentially interfering compounds that naturally occur in urine was examined with respect to extraction recovery, repeatability and selectivity. The components tested were NaCl, urea, creatinine and hippuric acid. The imprinted polymer was prepared using 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate as crosslinker and a structural analogue of the analyte as the template molecule. The recovery of diphenyl phosphate from water standards was over 90% using MISPE, compared to less than 25% using a non-imprinted SPE (NISPE) counterpart. The selectivity of MISPE compared to NISPE was achieved in a wash step with a basic modifier in methanol. The recovery and repeatability of the MISPE method were affected most by NaCl in the tested concentrations, while urea, creatinine and hippuric acid had no significant influence. NaCl most likely weakens the binding during the loading of the sample. This effect could be suppressed by diluting the sample with a citrate buffer at pH 4.0.  相似文献   

5.
白藜芦醇分子印迹聚合物微球的制备及特性评价(英文)   总被引:1,自引:0,他引:1  
以聚苯乙烯微球为种球,白藜芦醇为模板分子,采用单步溶胀聚合法在N,N-二甲基甲酰胺体系中制备了单分散分子印迹聚合物微球。用扫描电镜对微球的结构和形貌进行了表征,并研究了微球的制备条件和吸附特性。微球的凹陷可有效地增加微球的比表面积和结合位点,从而提高了模板分子的结合速率及微球的印迹容量。  相似文献   

6.
A novel method based on the molecularly imprinted solid-phase extraction (MISPE) procedure has been developed for the simultaneous determination of concentrations of sulfonylurea herbicides such as chlorsulfuron (CS), monosulfuron (MNS), and thifensulfuron methyl (TFM) in maize samples by liquid chromatography–tandem quadrupole mass spectrometry (LC–MS/MS). The molecularly imprinted polymer (MIP) for sulfonylurea herbicides was synthesized by precipitation polymerization using chlorsulfuron as the template molecule, 2-(diethylamino)ethyl methacrylate (DEAMA) as the functional monomer, and trimethylolpropane trimethacrylate (TRIM) as the cross-linker. The selectivities of the chlorsulfuron template and its analogs on the molecularly imprinted polymer were evaluated by high-performance liquid chromatography (HPLC). The extraction and purification procedures for the solid-phase extraction (SPE) cartridge with a molecularly imprinted polymer as the adsorbent for the selected sulfonylurea herbicides were then established. A molecularly imprinted solid-phase extraction method followed by high-performance liquid chromatography–tandem mass spectrometry for the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl was also established. The mean recoveries of these compounds in maize were in the range 75–110% and the limits of detection (LOD) of chlorsulfuron, monosulfuron, and thifensulfuron methyl were 0.02, 0.75, and 1.45 μg kg−1, respectively. It was demonstrated that the MISPE–HPLC–MS/MS method could be applied to the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl in maize samples.  相似文献   

7.
This study presents a novel, sensitive and selective molecularly imprinted solid‐phase extraction (MISPE)–spectrofluorimetric method for the removal and determination of atenolol from human urine. Molecularly imprinted and non‐imprinted polymers were synthesized thermally using a radical chain polymerization technique and used as solid‐phase extraction sorbents. Acrylic acid ethylene glycol dimethacrylate, dibenzoyl peroxide and dichloroethane were used as a functional monomer, cross‐linker, initiator and porogen, respectively. The calibration curve was in the range of 0.10–2.0 μg/ml for the developed method. Limit of detection and limit of quantification values were 0.032 and 0.099 μg/ml, respectively. Owing to the selectivity of the MISPE technique and the sensitivity of spectrofluorimetry, trace levels of atenolol have been successfully determined from both organic and aqueous media. Relatively high imprinting factor (4.18) and recovery results (74.5–75.3%) were obtained. In addition, intra‐ and interday precision values were 0.38–1.03% and 0.47–2.05%, respectively, proving the precision of the proposed method. Thus, a selective, sensitive and simple MISPE–spectrofluorimetric method has been developed and applied to the direct determination of atenolol from human urine.  相似文献   

8.
A useful approach was proposed to easily synthesize molecularly imprinted adsorbent for the purification of tylosin from broth. Firstly, by molecular simulation based on density functional theory, methacrylic acid was chosen as a functional monomer by comparing the binding energy. Second, a novel method of polymerization based on precipitation polymerization with added seeds was used in water-mixed solvent for the preparation of water-compatible micron-sized MIP. Its static adsorption capacity for tylosin in aqueous solution was estimated to be 106.5 mg/g with the highest imprinting factor (IF) of 3.6. The selectivity coefficient (α) of tylosin to desmycosin was 3.3. The antibiotic in fermentation broth could be purified by means of molecularly imprinted solid phase extraction (MISPE), which allows MIP to be used for the purification of tylosin from a complex sample.  相似文献   

9.
A highly selective molecularly imprinted solid-phase extraction (MISPE) coupled with high performance liquid chromatography (HPLC) ultraviolet-visible detection was developed for the simultaneous isolation and determination of four Sudan dyes (I, II, III and IV) in catsup products. The novel molecularly imprinted microspheres (MIM) were synthesized by aqueous suspension polymerization using phenylamine and naphthol as template, which showed high affinity to Sudan dyes in aqueous solution. In order to develop a selective extraction protocol for simultaneous determination the four Sudan dyes from catsup products, the molecular recognition properties of MIM as a SPE sorbent were evaluated. Under the optimized condition, good linearity was obtained from 0.01 to 2.5 μg g(-1) (r(2)≥ 0.9990) with the relative standard deviations of less than 3.4%. This proposed MISPE-HPLC procedure eliminated the effect of template leakage on quantitative analysis and could be applied to direct determination of four Sudan dyes in complicated food samples.  相似文献   

10.
A new surface imprinting technique was reported to synthesize multi-walled carbon nanotubes-molecularly imprinted polymers (MWNTs-MIPs) using erythromycin as the template, acryloyl-β-cyclodextrin (acryloyl-β-CD) and methacrylic acid (MAA) as the binary functional monomers. The MWNTs-MIPs were characterized by transmission electron microscopy (TEM), scanning electron micrograph (SEM) and Fourier transform-infrared spectroscopy (FT-IR). Adsorption experiments indicated the MWNTs-MIPs prepared with acryloyl-β-CD and MAA have high selective for erythromycin. The feasibility of the MWNTs-MIPs as solid-phase extraction (SPE) sorbent was evaluated, and the results showed that it can selectively extract erythromycin from chicken muscle samples with the recoveries ranging from 85.3% to 95.8%. The molecularly imprinted solid-phase extraction (MISPE) method could be applied for preconcentration and purification of erythromycin from chicken muscle samples.  相似文献   

11.
In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%.  相似文献   

12.
This paper describes the rational design, generation and testing of a molecularly imprinted polymer specific for Ibuprofen. Ibuprofen is a member of the class of drugs termed non-steroidal anti-inflammatory drugs (NSAIDS). In the present study, Ibuprofen was used as a template molecule for the preparation of molecularly imprinted polymers. A MIP has been produced which is capable of recognising Ibuprofen in aqueous media. Furthermore, Ibuprofen can be selectively extracted from aqueous conditions by molecularly imprinted solid phase extraction (MISPE). Recoveries were typically high (>80%) and good selectivity for Ibuprofen over structurally related analogues was seen. Moreover, the nature of the recognition between MIP and template has been investigated by NMR and molecular modelling to analyse whether or not it is possible to predict how well a given MIP will perform under set conditions. In addition, the physical characteristics of the MIP have been investigated including the particle size distribution on exposure of the MIP to different solvents. This has been related to the ability of the MIP to rebind Ibuprofen under the same conditions. The data from the characterisation of the MIP has been used to further enhance the understanding of the nature of MIP recognition.  相似文献   

13.
In this study, a novel method is described for the determination of tramadol in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as the sample clean-up technique combined with high-performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and tramadol as template molecule. The novel imprinted polymer was used as a solid-phase extraction (SPE) sorbent for the extraction of tramadol from human plasma and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for the MIP cartridges were studied. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of tramadol. The limit of detection (LOD) and limit of quantification (LOQ) for tramadol in urine samples were 1.2 and 3.5 μg L−1, respectively. These limits for tramadol in plasma samples were 3.0 and 8.5 μg L−1, respectively. The recoveries for plasma and urine samples were higher than 91%.  相似文献   

14.
Yang Y  Yi C  Luo J  Liu R  Liu J  Jiang J  Liu X 《Biosensors & bioelectronics》2011,26(5):2607-2612
A voltammetric glucose sensor was prepared from novel molecularly imprinted polymeric micelles (MIPMs) through direct electrodeposition. The MIPMs, which were photo-crosslinkable and nano-scaled with high specific surface area, were prepared via macromolecule self-assembly of an amphiphilic photo-crosslinkable copolymer, combined with a molecular imprinting technique using glucose as the template molecule. A MIP film was formed in situ on the electrode surface by electrodeposition of the MIPMs, while photo-crosslinking led to a robust film which showed good solvent resistant to dissolution. With these features, the resulting sensor showed good response and selectivity towards glucose. In particular, the linear response of this glucose sensor ranged from 0.2 mM to 8 mM and its comparatively higher detection limit, about 10 mM, indicated numerous effective recognition sites among the polymer matrix due to the large specific surface area of MIPM. In addition, this MIP sensor also showed good stability and reversibility. The contribution of this work lies in not only the invention of a new type of glucose MIP sensor with good performance, but also the creation of a novel strategy to develop advanced MIP sensors for a wide range of templates in viewing of the versatility of the amphiphilic copolymers and the ease of control and applicability of the electrodeposition process.  相似文献   

15.
A novel fluorescent nanosensor using molecularly imprinted silica nanospheres embedded CdTe quantum dots (CdTe@SiO2@MIP) was developed for detection and quantification of chloramphenicol (CAP). The imprinted sensor was prepared by synthesis of molecularly imprinting polymer (MIP) on the hydrophilic CdTe quantum dots via reverse microemulsion method using small amounts of solvents. The resulting CdTe@SiO2@MIP nanoparticles were characterized by fluorescence, UV–vis absorption and FT‐IR spectroscopy and transmission electron microscopy. They preserved 48% of fluorescence quantum yield of the parent quantum dots. CAP remarkably quenched the fluorescence of prepared CdTe@SiO2@MIP, probably via electron transfer mechanism. Under the optimal conditions, the relative fluorescence intensity of CdTe@SiO2@MIP decreased with increasing CAP by a Stern–Volmer type equation in the concentration range of 40–500 µg L–1. The corresponding detection limit was 5.0 µg L–1. The intra‐day and inter‐day values for the precision of the proposed method were all <4%. The developed sensor had a good selectivity and was applied to determine CAP in spiked human and bovine serum and milk samples with satisfactory results. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
Naturally occurring steroids such as progesterone, testosterone and 17β-estradiol were analyzed in this study. These bio-identical molecules paradoxically can be either beneficial or harmful. Unfortunately as growth promoters can be toxic and cancerogenic at elevated levels. Due to difficulty in monitoring at trace quantities of these hormones in biological matrices specific adsorption materials molecularly imprinted polymers (MIPs) were used for preconcentration and clean up in sample preparation step. A non-covalent imprinting approach was used for bulk polymerization of progesterone, testosterone and 17β-estradiol imprinted polymers. Synthesis of MIPs was achieved by thermal, UV and γ irradiation initiated polymerization whereby were used methacrylic acid (MAA), 4-vinylpyridine (4-VP) as functional monomers, ethylene glycol dimethacrylate (EDMA), trimethylolpropane trimethacrylate (TRIM) as cross-linking agents and acetonitrile, isooctane–toluene (1:99, v/v) and chloroform as porogen solvents. It was also used as initiator 2,2′-azobis(2-methylpropionitrile) (AIBN) or benzyl methyl ether (BME). The MIPs were applied as selective sorbents in solid-phase extraction (SPE). Molecularly imprinted solid-phase extraction (MISPE) considered as hyphenated technique were applied in extraction step before HPLC-DAD analysis of steroids from human urine.  相似文献   

17.
Molecularly imprinted polymeric microbeads (MIPMs) were prepared by the suspension and modified suspension polymerization methods using D-phenylalanine as the template, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, toluene as the porogen, polyvinyl alcohol as the stabilizer, and sodium dodecyl sulfate as the surfactant. The addition of a surfactant to the conventional suspension polymerization mixture decreased the mean particle size of the MIPMs and increased the adsorption selectivity. For the modified suspension polymerization method, the mean particle size of the MIPMs was smaller than the particle size of MIPMs prepared via conventional suspension polymerization. Moreover, the adsorption selectivity improved considerably compared to the adsorption selectivities of MIPs reported previously.  相似文献   

18.
Highly efficient enantioselective separation and quantitative recoveries of D- and L-tryptophan in aqueous and real samples can be achieved, with a monolithic molecularly imprinted polymeric fiber that serves both for micro-solid phase extraction and ultratrace sensing, without any false-positive (non-specific) contribution and cross-reactivity, in the range of 0.15-30.00 ng mL(-1) with detection limit as low as 0.0261 ng mL(-1) (relative standard deviation=0.64%, signal/noise=3). The proposed method combining molecularly imprinted micro-solid phase extraction fiber and a complementary molecularly imprinted polymer-carbon composite fiber sensor is proven to be useful for clinical diagnosis of stress-related diseases caused by acute tryptophan depletion.  相似文献   

19.
Molecularly imprinted polymers are highly stable and can be sterilised, making them ideal for use in biotransformation process. In this communication, we describe a novel application of molecularly imprinted polymers in an enzymatic reaction. The enzymatic condensation of Z-L-aspartic acid with L-phenylalanine methyl ester to give Z-L-Asp-L-Phe-OMe (Z-aspartame) was chosen as a model system to evaluate the applicability of using molecularly imprinted polymers to facilitate product formation. When the product-imprinted polymer is present, a considerable increase (40%) in product yield is obtained. Besides their use to enhance product yields, as demonstrated here, we suggest that imprinted polymers may also find use in the continuous removal of toxic compounds during biochemical reactions.  相似文献   

20.
An analytical methodology for the analysis of methamidophos in water and soil samples incorporating a molecularly imprinted solid-phase extraction process using methamidophos-imprinted polymer was developed. Binding study demonstrated that the polymer exhibited excellent affinity and high selectivity to the methamidophos. Evidence was also found by FT-IR analysis that hydrogen bonding between the CO(2)H in the polymer cavities and the NH(2) and P=O of the template was the origin of methamidophos recognition. The use of molecularly imprinted solid-phase extraction improved the accuracy and precision of the GC method and lowered the limit of detection. The recovery of methamidophos extracted from a 10.0 g soil sample at the 100 ng/g spike level was 95.4%. The limit of detection was 3.8 ng/g. The recovery of methamidophos extracted from 100 mL tap and river water at 1 ng/mL spike level was 96.1% and 95.8%, and the limits of detection were 10 and 13 ng/L respectively. These molecularly imprinted solid-phase extraction procedures enabled selective extraction of polar methamidophos successfully from water and soil samples, demonstrating the potential of molecularly imprinted solid-phase extraction for rapid, selective, and cost-effective sample pretreatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号