1.
During the last years increasingly cementless hip endoprostheses have been implanted. Radiological wear measurement of cemented hip endoprostheses for the material couples polyethylene cup-ceramic- or metal head has been established in the literature. However, for cups encased by metal (screwing or pressfit cups), this method of measurement is not applicable. Therefore, a method has been developed to measure wear on radiographs on cementless spherical implants. The data were compared to those, obtained from conventional wear measurements on cemented hip cups. The results indicate that both techniques generate comparable results, thus validating the new technique as being suited for cementless cup implants.  相似文献   

2.
In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ?A) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ?A. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.  相似文献   

3.
Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.  相似文献   

4.
AIM: Most methods used for the determination of volumetric wear of polyethylene cups are based on the assumption that the head of the prosthesis penetrates the cup in "cylindrical" fashion. The new accurate optical method is independent of this disputable assumption. METHOD: The articulating surface of the cup is scanned with light and a data set of 60,000 pixels obtained in this way is stored in a computer. Data obtained from used cups were compared with those obtained from unused cups. The volumetric wear was calculated directly by threefold integration. To assess the changes in surface shape, the data are fitted by an ellipsoid whose long axis defines the mean direction of load. A total of 18 retrieved and 3 unused cups of different types were studied. RESULTS: The unused acetabular cups deviated only slightly from ideal hemispheres. The surfaces showed rotational symmetry, and an undulation having an amplitude of 0.1 mm between dome and equator. For all explanted cups, the assumption of cylindrical penetration of the head into the polyethylene was shown not to represent the true situation. The cup expands in all directions, and the volumetric wear is underestimated by 50% with the traditional methods. The data suggest that long-term survival may be jeopardized when the main direction of loading is centered on the dome of the cup. Ceramic heads were associated with smaller rates of volumetric wear. CONCLUSION: The new optical method is characterised by short measuring times, precision and simple application. Analysis of the wear patterns of polyethylene components using this technique may contribute to a further understanding of the complex mechanisms of aseptic loosening.  相似文献   

5.
The precision of digital vs. manual radiostereometric measurements in total hip arthroplasty was evaluated using repeated stereoradiographic exposures with an interval of 10-15 min. Ten Lubinus SP2 stems cemented into bone specimens and 12 patients with the same stem design were used to evaluate the precision of stem translations and rotations. The precision of translations and rotations of the cup and femoral head penetration was studied in 12 patients with whole polyethylene cups.The use of a measurement method based on digitised radiographs improved the precision for some of the motion parameters, whereas many of them did not change. A corresponding pattern was observed for both the intra- and interobserver error. Of the wear parameters, the most pronounced improvements were the 3D wear and in the proximal-distal direction, although the anterior-posterior precision was also improved. The mean errors of rigid body and elliptic fitting decreased in all evaluations but one, consistent with a more reproducible identification of the markers centres and the edge of the femoral head.Increased precision of radiostereometric measurements may be used to increase the statistical power of future randomised studies and to study new fields in orthopaedics requiring higher precision than has been available with RSA based on manual measurements.  相似文献   

6.
To isolate the primary variables influencing acetabular cup and interface stresses, we performed an evaluation of cup loading and cup support variables, using a Statistical Design of Experiments (SDOE) approach. We developed three-dimensional finite element (FEM) models of the pelvis and adjacent bone. Cup support variables included fixation mechanism (cemented or noncemented), amount of bone support, and presence of metal backing. Cup loading variables included head size and cup thickness, cup/head friction, and conformity between the cup and head. Interaction between and among variables was determined using SDOE techniques. Of the variables tested, conformity, head size, and backing emerged as significant influences on stresses. Since initially nonconforming surfaces would be expected to wear into conforming surfaces, conformity is not expected to be a clinically significant variable. This indicates that head size should be tightly toleranced during manufacturing, and that small changes in head size can have a disproportionate influence on the stress environment. In addition, attention should be paid to the use of nonmetal backed cups, in limiting cup/bone interface stresses. No combination of secondary variables could compensate for, or override the effect of, the primary variables. Based on the results using the SDOE approach, adaptive FEM models simulating the wear process may be able to limit their parameters to head size and cup backing.  相似文献   

7.
A new finite element model (FEM) based on an elasto-plastic behavior of ultra high molecular weight polyethylene (UHMWPE) was used to study the wear behavior of UHMWPE acetabular cup, which has a 32 mm diameter femoral head. The model imposed a plastic yield stress of 8 MPa on the UHMWPE so that any stresses beyond this would automatically be redistributed to its neighbor. The FEM model adopted a unique mesh design based on an open cube concept which eliminated the problems of singularities. Wear prediction combined the influences of contact stress, sliding distance and a surface wear coefficient. The new model predicted significantly higher volumetric wear rate (57 mm(3)/yr) well within the average reported clinical values. The model was also used to study the effect of friction and clearance between the acetabular cup and the femoral head. Increase in friction increased the volumetric wear rate but did not appear to affect the linear wear rate, which remained at 0.12 +/- 0.02 mm/yr. The predicted wear was sensitive to clearance. It was found that when the clearance was close to 0 and >0.5mm, severe wear occurred. The best clearance range was between 0.1 and 0.15 mm where the average linear wear rate was 0.1mm/yr and the volumetric wear was 55 mm(3)/yr. The present work indicates the importance of avoiding too tight or too loose a diametrical clearance.  相似文献   

8.
Proper cup alignment is crucial in total hip arthroplasty for reducing impingement risks, dislocations and wear. The Lewinnek “safe zone” is often used in clinical routine. This safe zone does not consider functional aspects and dislocation can occur even when the cup is oriented within the safe zone. Functional safe zones based on the hip range of motion (ROM) were introduced but are not commonly used in clinical routine. The reason might be that these methods are time-consuming due to complex simulations. A relatively fast method based on analytical mathematical formulas was proposed, but it is difficult to consider arbitrary motion. This work introduces an efficient algorithm for calculating a patient-specific target zone based on the target ROM which can consider any set of motions. The method is based on matrix transformations and trigonometric formulas. The resulting target zone which contains all impingement-free cup orientations is dependent on the patient-specific pelvic tilt, the 3D angular neck and stem orientation within the femur, and the technical prosthesis ROM. This method could be integrated into computer-assisted preoperative planning and intra-operative navigation tools. As pelvic tilt and stem orientation influence the optimal cup orientation they need to be acquired from the patient to derive a patient-specific ROM-based target zone.  相似文献   

9.
In this paper an application of the boundary element method for simulating wear in total hip prosthesis is presented. Several examples including different update periods of the worn acetabular cup, various femoral head sizes and various materials for both the femoral head and the acetabular cup are simulated under the same variable loading conditions for up to 20 years of service. Moreover, two different femoral models are considered in order to investigate the influence of the femoral modelling. The analysis demonstrates that due to the boundary only modelling requirement, the computational time and storage remains low, allowing large service periods to be simulated. Generally, the results obtained are in good agreement with other researchers findings. Moreover, ignoring the bending of the femoral neck in the model, results in a small overestimation of the maximum wear depth, while the volumetric wear is slightly underestimated. However, these differences are trivial considering the reduction of the computational effort.  相似文献   

10.
Excessive wear in total knee arthroplasty is detected by measuring the minimum joint space width (mJSW) in anterioposterior radiographs. The accuracy of conventional measurement methods is limited and can be improved using model-based techniques. In this study, the model-based wear measurement (MBWM) is introduced. Its accuracy and reproducibility are assessed and compared to the conventional measurement. Forty anterioposterior radiographs were obtained of a knee prosthesis using a phantom setup. Both measurement methods were applied and the accuracy and precision were compared. The reproducibility was calculated with inter- and intra-observer experiments. Three observers measured the mJSW in 30 clinical radiographs with both the conventional measurement and the MBWM and repeated this after 6 weeks. The experiments were conducted with a NexGen mobile bearing and fixed bearing prostheses. In the phantom experiment, the accuracy (mean of the absolute error) was significantly higher (t-test, p<0.01) for the MBWM as for the conventional measurement (0.15 mm versus 0.43 mm, 0.14 mm versus 0.35 mm for the mobile and fixed bearing, respectively). The standard deviation of the measurements is the smallest for the MBWM measurement for both prosthesis types (0.16 mm versus 0.47 mm, Levene's test, p<0.01). In the reproducibility experiment, both the intra- and inter-observer agreements were higher for the MBWM than for the conventional method. The results show that the MBWM is superior to the conventional measurement in both accuracy and reproducibility. Although the use of a phantom experiment poses some limitations in conveying the findings to clinical practice, this improved mJSW measurement can lead to better wear detection for surgery decisions and research purposes.  相似文献   

11.
For assessing migration of cups, standard X-rays or stereo radiological images (SRI) are available. In addition, software is also available for measurements. The accuracies of the various systems are established statistically, in part combined with phantoms, and compared. To date, no known phantom is available for the simulation of acetabular cup migration with account being taken of the position of the pelvis in the X-ray beam. Such an appliance covering 8 different parameters has now been developed, the cup can be moved horizontally, vertically and in the loading direction. Angular accuracy is +/- 0.5 degree, and wear of a magnitude of 0.25 mm can be simulated. Two degree elevation of the pelvis, left or right, can be simulated. The position of the pelvis around the horizontal axis permits continuous variation. This appliance can simulate migratory movements of the acetabular cup within a pelvis, and wear within the cup. In addition, the spatial position of the pelvis can be varied. The X-ray images can be used to investigate the accuracy of evaluation strategies.  相似文献   

12.
Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.  相似文献   

13.

Background  

Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups.  相似文献   

14.
The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study.  相似文献   

15.
Polyethylene wear after total hip arthroplasty may occur as a result of normal gait and as a result of subluxation and relocation with impact. Relocation of a subluxed hip may impart a moment to the cup creating sliding as well as compression at the cup liner interface. The purpose of the current study is to quantify, by a validated finite element model, the forces generated in a hip arthroplasty as a result of subluxation relocation and compare them to the forces generated during normal gait. The micromotion between the liner and acetabular shell was quantified by computing the sliding track and the deformation at several points of the interface. A finite element analysis of polyethylene liner stress and liner/cup micromotion in total hip arthroplasty was performed under two dynamic profiles. The first profile was a gait loading profile simulating the force vectors developed in the hip arthroplasty during normal gait. The second profile is generated during subluxation and subsequent relocation of the femoral head. The forces generated by subluxation relocation of a total hip arthroplasty can exceed those forces generated during normal gait. The induced micromotion at the cup polyethylene interface as a result of subluxation can exceed micromotion as a result of the normal gait cycle. This may play a significant role in the generation of backsided wear. Minimizing joint subluxation by restoring balance to the hip joint after arthroplasty should be explored as a strategy to minimize backsided wear.  相似文献   

16.

Background

Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators.

Methods

Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators.

Results

The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm3/MC and 0.89±0.04 mm3/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC.

Conclusions

This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release.

Clinical Relevance

This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.  相似文献   

17.
Prediction of lubricating film thickness in UHMWPE hip joint replacements   总被引:4,自引:0,他引:4  
An elastohydrodynamic lubrication model developed for a ball-in-socket configuration in a previous studies by the present authors (Jalali-Vahid et al., Thinning films and tribological interfaces, 26th Leeds-Lyon Symposium on Tribology, 2000, pp. 329-339) was applied to analyse the lubrication problem of a typical artificial hip joint replacement, consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup against a metallic or ceramic femoral head. The cup was assumed to be stationary whilst the ball was assumed to rotate at a steady angular velocity and under a constant load. A wide range of main design parameters were considered. It has been found that the predicted lubricating film thickness increases with a decrease in the radial clearance, an increase in the femoral head radius, an increase in UHMWPE thickness and a decrease in UHMWPE modulus. However, the predicted lubricating film thicknesses are not found to be sufficiently large in relation to the surface roughness of the cup and head to indicate separation of the two articulating surfaces. It should also be noted that if the design features are unable to secure full fluid film lubrication, it may be preferable to select them for minimum wear rather than maximum film thickness. For example, an increase in head radius will enhance the film thickness, but it will also increase the sliding distance and hence wear in mixed or boundary lubrication conditions. Furthermore, it is pointed out that an increase in the predicted lubricant film thickness is usually associated with an increase in the contact area, and this may cause lubricant starvation and stress concentration at the edge of the cup, and adversely affect the tribological performance of the implant. The effect of running-in process on the lubrication in UHMWPE hip joint replacements is also discussed.  相似文献   

18.
The present investigation focuses on total hip replacement using ceramic acetabular components. The relationship between the position of the cup and the range of motion (ROM) was investigated. A limited range of motion may cause impingement, which is defined as contact between the femoral neck and the rim of the acetabular cup. Impingement may result in wear, chipping, fracture or dislocation of the femoral head. Joint movements were simulated in a three-dimensional CAD program. The results obtained underscore the importance of correct positioning and design of the cup for achieving a ROM as close to the physiological situation as possible. With ceramic cups, the inclination angle should not be more than 45 degrees, and the antetorsion angle between 10 and 15 degrees. If the cup is too vertical, the risk of dislocation and fracture of the ceramic increases. If, on the other hand, the angle of inclination is too small, flexion and abduction will be greatly limited. The study shows that acetabular components with non-recessed ceramic inserts should not be used. Slight recession of the insert helps to avoid impingement. The ROM is reduced and the risk of impingement appreciably increased when mushroom-shaped femoral heads (XL heads) or ceramic inserts protected by a polyethylene ring are used.  相似文献   

19.
Novel algorithms for radiostereometric (RSA) measurements of the femoral head and metal-backed, hemi-spherical cups of a total hip replacement are presented and evaluated on phantom images and clinical double examinations of 20 patients. The materials were analysed with classical RSA and three novel algorithms: (1) a dual-projection head algorithm using the outline of the femoral head together with markers in the cup; (2) a marker-less algorithm based on measurements of the outline of the femoral head, the cup shell and opening circle of the cup; and (3) a combination of both methods. The novel algorithms improve current, marker-based, RSA measurements, as well as allows studies without marked cups. This opens the possibility of performing wear measurements on larger group of patients, in clinical follow-ups, even retrospective studies. The novel algorithms may help to save patient data in current RSA studies lost due to insufficiently marked cups. Finally, the novel algorithms simplify the RSA procedure and allow new studies without markers, saving time, money, and reducing safety concerns. Other potential uses include migration measurements of re-surfacing heads and measuring spherical sections as implant landmarks instead of markers.  相似文献   

20.
A new bio-tribological simulator system was designed and built for basic wear tests on artificial hip joint materials and for common tribological studies applications. The module of hip joint simulator is consisted of Flexion and Extension (FE), Abduction and Adduction (AA) and Internal and External Rotation (IER). Preliminary tests were done with a 28 mm CoCrMo femoral head and a Ultra High Molecular Weight Polyethylene (UHMWPE) cup. Results showed that the wear rate was close to the clinical one. A frequency control system and a heating system were developed to offer a wide range of rotation frequency and temperature so as to provide proper experiments. In the Pin-on-Disk (POD) part, eight precision-made pins were generated and an advanced computer system was built up to measure the friction coefficient of the tests samples.  相似文献   