鲁米诺是一种对于不可见血迹进行增强显示的试剂,是法医科学中最敏感的显色试剂之一,同时也可作为发光试剂应用于各种生物检测体系中。出于对安全与健康的担心,该试剂在英国和其他一些欧洲国家的使用一直受到限制。本文综述了有关鲁米诺试剂对于健康的影响的研究进展,分析显示只要采取适当的防护措施,在犯罪现场或在实验室使用鲁米诺试剂的安全风险可控。  相似文献   

2.
The forensic luminol test has long been valued for its ability to detect trace amounts of blood that are invisible to the naked eye. This is the first quantitative study to determine the effect on the luminol test when an attempt is made to clean bloodstained tiles with a known interfering catalyst (bleach). Tiles covered with either wet or dry blood were tested, and either water or sodium hypochlorite solution (bleach) was used to clean the tiles. As expected, the chemiluminescence intensity produced when luminol was applied generally decreased with the number of times that a tile was cleaned with water, until the chemiluminescence was neither visible nor detectable. However, when the tiles were cleaned with bleach there was an initial drop in chemiluminescence intensity, followed by a rise to a consistently high value, visibly indistinguishable from that of blood. Examination of bleach drying time suggested that any interfering effect becomes negligible after 8 h.  相似文献   

3.
《Luminescence》2003,18(4):193-198
This paper presents the ?rst comprehensive and quantitative study of substances that interfere with the forensic luminol test for blood. Two hundred and ?fty substances have been selected on the basis of modern lifestyles and of contiguity with crime scenes. The intensity of the chemiluminescence produced by each substance has been measured relative to that of haemoglobin and the peak wavelength shift has also been determined. The following is a short list of nine substances that produce chemiluminescence intensities comparable with that of haemoglobin: turnips, parsnips, horseradishes, commercial bleach (NaClO), copper metal, some furniture polishes, some enamel paints, and some interior fabrics in motor vehicles. Care needs to be taken when the luminol test for blood is used in the presence of these substances. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
Na Li  Shubiao Ni 《Luminescence》2014,29(8):1130-1134
The use of noble metal nanoparticles (NPs) as reductants in chemiluminescence (CL) has been reported only rarely owing to their high oxidation potentials. Interestingly, nucleophiles could dramatically lower the oxidation potential of Ag NPs, such that in the presence of nucleophiles Ag NPS could be used as reductants to induce the CL emission of luminol, an important CL reagent widely used in forensic analysis for the detection of trace amounts of blood. Although nucleophiles are indispensible in Ag NP‐luminol CL, only inorganic nucleophiles such as Cl, Br, I and S2O32‐ have been shown to be efficient. The effects of organic nucleophiles on CL remain unexplored. In this study, 20 standard amino acids were evaluated as novel organic nucleophiles in Ag NP‐luminol CL. Histidine, lysine and arginine could initiate CL emission; the others could not. It is proposed that the different behaviors of 20 standard amino acids in the CL reactions derive from the interface chemistry between Ag NPs and these amino acids. UV/vis absorption spectra were studied to validate the interface chemistry. In addition, imidazole and histidine were chosen as a model pair to compare the behavior of the monodentate nucleophile with that of the corresponding multidentate nucleophile in Ag NP‐luminol CL. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
This study evaluates the sensitivity, specificity and predictive values of several techniques commonly used for the detection of Helicobacter pylori in an analysis of 105 biopsy specimens (gastric and duodenal). For comparative purposes, the techniques investigated were divided into 2 groups: histopathological and microbiological. The former included hematoxylin-eosin and Giemsa stains, a Gram stain modified for use in tissue, and immunohistochemical techniques. Microbiological analysis was performed using culture, the urease test and the conventional Gram stain. The immunohistochemical techniques proved to be the most sensitive (93%). The modified Gram stain was sufficiently sensitive (92%) and specific (97%) for the detection of the bacterium. When combined with a microbiological technique such as the urease test, this stain showed increased sensitivity (96%) but its specificity was reduced to 94%. This combination of tests is recommended for the detection of H. pylori in biopsy specimens since it is easily performed at low cost and gives excellent results. For economical reasons, it is suggested that the use of immunohistochemical techniques should be restricted to specific cases.  相似文献   

6.
The luminol chemiluminescence reaction has, for some time, been used as a tool for the detection of haemoglobin at crime scenes. More recently, the luminol test has been suggested as a possible tool for estimating the post‐mortem interval (PMI) of skeletal remains. The preliminary results from the following study indicate that the chemiluminescent luminol test is a relatively easy and economical method for distinguishing between remains of medico‐legal (≤100 years) and historical (>100 years) interest. The femur was the preferred bone for PMI measurements using the luminol test, due to its robustness and relative resistance to diagenesis. Initial results suggest that bone that was historical in nature, produced a demonstrably weaker reaction than that of medico‐legal interest. These results suggest that the luminol test is a promising technique, albeit with some limitations, for the assessment of skeletal material that may be potentially of medico‐legal interest. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
At very low horseradish peroxidase (HRP) concentrations, the enhanced chemiluminescence reaction is often characterized by a lag time between initiation of the reaction and beginning of light output. In this study, four treatments of luminol solution were examined in an effort to remove the lag time and to improve chemiluminescence light output. Addition of ammonium persulphate stimulated light output more than tenfold. Ultraviolet irradiation and photoactive dye pretreatment of luminol solution both increased light output fourfold. Luminol purity was the most important factor affecting detection sensitivity. Recrystallization of luminol from base improved the detection limit 13-fold although there was an improvement in the detection limit from 13 attomoles per millilitre to 5 attomoles per millilitre with highly purified luminol when photoactive dye pretreatment was utilized. The results are consistent with a simple interference mechanism whereby enhancer radicals produced by the enzyme are preferentially quenched by contaminants present in the luminol, in the enhancer and in the solvent used to dissolve the enhancer. Consumption of these interferences prior to light emission results in a lag time and a less favourable HRP detection limit.  相似文献   

8.
We here in report the synthesis of gold nanoparticles (AuNPs) using a Crinum macowanii bulb water extract. The as‐synthesized AuNPs were characterized using ultraviolet–visible spectroscopy, Fourier transform infrared spectroscopy, X‐ray diffraction, transmission electron microscopy, and a zeta potential‐sizer. The results showed that the as‐synthesized AuNPs were crystalline and mostly spherical in shape with a small mixture of triangular, tetrahedral, hexagonal, octagonal, and diamond shapes. The as‐synthesized AuNPs together with those synthesized by conventional methods were subsequently used as enhancers for the luminol signal in blood detection. It was noted that the AuNPs synthesized from the Crinum macowanii bulb water extract could enhance the chemiluminescence signal for blood detection by luminol to the same extent as AuNPs prepared by conventional methods. Furthermore, both types of AuNPs served as fluorescence enhancers for blood detection when luminol was replaced with the bulb water extract.  相似文献   

9.
Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on‐line photoreactor. This method is based on on‐line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
New imaging techniques are still the topic of many evaluations for both the diagnosis of Helicobacter pylori gastritis and the detection of early gastric cancer. Concerning invasive tests, there were studies on the reuse of the rapid urease test material for other tests, and a novel fluorescent method to be used for histology but with limited sensitivity. Progress occurred essentially in the molecular methods area, especially next‐generation sequencing which is applied to detect both H pylori and the mutations associated with antibiotic resistance. For non‐invasive tests, a few studies have been published on the validity of breath collection bags, the shortening of the testing time, the performance of different analysers or the added value of citric acid in the protocol. The accuracy of serological immunochromatographic tests is also improving. Multiplex serology detecting antibodies to certain proteins allows confirmation of a current infection. Dried blood spots can be used to collect and store blood without a loss of accuracy. Finally, the serum antibody titer can be useful in predicting the risk of gastric cancer. Several stool antigen tests were evaluated with good results, and a novel test using immunomagnetic beads coated with monoclonal antibodies is potentially interesting. PCR detection in stools can also be effective but needs an efficient DNA extraction method. The use of easyMAG® (bioMérieux) combined with Amplidiag® H pylori + ClariR (Mobidiag) appears to be powerful.  相似文献   

11.
A specific and sensitive assay for the detection of human blood was developed using polyester cloth coated with goat anti-human IgG antibody to capture human IgG, an abundant and stable protein in blood. The captured IgG was detected by the reaction between goat anti-human IgG antibody-peroxidase conjugate and a chromogenic peroxidase substrate. Because the assay is simple and rapid, and permits simultaneous analysis of multiple samples, it has the potential to be used as a forensic test for human blood.  相似文献   

12.
Antigen testing is now recognized as the method of choice for detection of Wuchereria bancrofti infections. Unlike tests that detect microfilariae, antigen tests can be performed with blood collected during the day or night. However, existing enzyme-linked immunosorbent assay (ELISA) tests for filarial antigenemia are difficult to perform in the field, and this has limited their use in endemic countries. In this article, Gary Weil, Patrick Lammie and Niggi Weiss review their experience with a new rapid-format filarial antigen test. They found that the ICT card test was very easy to perform and that it was comparable with ELISA for the detection of filarial antigen in sera from people with microfilaremia. The introduction now of an antigen test suitable for use in the field is especially timely, in that it may facilitate implementation of new strategies proposed by the World Health Organization for control and elimination of lymphatic filariasis.  相似文献   

13.
The luminol test for blood was carried out on a set of interior fittings and surfaces inside three different makes of modern motor car. The surfaces and fittings provided little interference with the test for blood, although there was some detectable chemiluminescence when the test was applied to blood-free material from a seatbelt, a boot-lining and a gear-knob. The case with which haemoglobin samples could be washed off interior car surfaces was also examined for seat fabrics, carpets, roof-linings and various other plastic interior surfaces. A standard wash with water alone was not very effective and removed only ca. 50% of the haemoglobin. A standard wash with soapy water or with a proprietary multipurpose car cleaner removed ca. 90% of the haemoglobin from the tested surface. The effect of high car interior temperatures on haemoglobin samples that were subsequently used in the luminol test was also examined. It was shown that the sensitivity of the luminol test was not decreased but was increased by the prior heating of a haemoglobin sample. This effect was attributed to the thermal conversion of haemoglobin to the more brighter catalyst for chemiluminescence, methaemoglobin. The enthalpy of this conversion in the solid state was found to be 14.1 kJ/mol.  相似文献   

14.
Antibody production tests have traditionally been used to test biological materials for viral contamination. Now molecular biology techniques have emerged as an alternative. The authors compare MAP testing with PCR-based detection methods, focusing on differences in animal use, laboratory requirements, sample size, and limits of detection.  相似文献   

15.
Chemiluminescence enzyme immunoassay of 8-oxoguanine in DNA.   总被引:1,自引:0,他引:1  
A test system has been developed to determine 8-oxoguanine in DNA, the most important biomarker of damage to DNA bases by reactive oxygen species. The system is based on a chemiluminescence enzyme immunoassay with the use of monoclonal antibodies (mcAB) against 8-oxoguanine. The test involves several stages: 1) immobilization of DNA on nitrocellulose membrane filters using an efficient technique with preliminary formation of a complex with protamine sulfate; 2) formation of antigen--antibody complexes (mcAB with 8-oxoguanine in DNA) with secondary antibodies and with a peroxidase--antiperoxidase complex (PAP method); 3) detection of increased chemiluminescence in a solution of hydrogen peroxide, luminol, and p-iodophenol. The increased chemiluminescence is determined with a conventional liquid scintillation counter for measuring beta-radioactivity. The system was tested by determining 8-oxoguanine formation in DNA upon gamma-irradiation and upon photosensitized oxidation of guanine under visible light in the presence of methylene blue. A linear dose dependence of 8-oxoguanine formation in DNA was shown for gamma-irradiation. The radiation-chemical yield of 8-oxoguanine (G = 0.57 molecule per 100 eV) is convenient to use for calibration of the amount of 8-oxoguanine formed under other conditions. The sensitivity of the method permits the detection of several femtomoles of 8-oxoguanine in a 40 microg sample of DNA.  相似文献   

16.
While the incidence of Human African Trypanosomiasis (HAT) is decreasing, the control approach is shifting from active population screening by mobile teams to passive case detection in primary care centers. We conducted a systematic review of the literature between 1970 and 2011 to assess which diagnostic tools are most suitable for use in first-line health facilities in endemic countries. Our search retrieved 16 different screening and confirmation tests for HAT. The thermostable format of the Card Agglutination Test for Trypanosomiasis (CATT test) was the most appropriate screening test. Lateral flow antibody detection tests could become alternative screening tests in the near future. Confirmation of HAT diagnosis still depends on visualizing the parasite in direct microscopy. All other currently available confirmation tests are either technically too demanding and/or lack sensitivity and thus rather inappropriate for use at health center level. Novel applications of molecular tests may have potential for use at district hospital level.  相似文献   

17.
An overview is presented on the power and drawbacks of the relatively unfamiliar chemiluminescence-based detection technique applied in analysis by capillary electrophoresis, for determining chemically derivatized biomolecules. Examples of the most common systems are given for many series of biologically active compounds as well as for some pharmaceuticals. The most common chemiluminescent systems include the application of peroxyoxalate ester chemiluminescence, acridinium esters, luminol and derivatives, detection based on the tris(2,2'-bipyridine)ruthenium(III) system, the huge potentials offered by direct oxidations-though often with still unelucidated reaction mechanisms-and the powerful area of bioluminescence techniques, revealing as well the fast developing area of microchip-based analysis employing this specific luminescence principle.  相似文献   

18.
The passive hemagglutination test (Sero-Test CCB) for the detection of hepatitis B surface antigen (HBsAg) has been developed. The comparative study of the sensitivity of Sero-Test CCB, the passive hemagglutination test Hepanostikon (developed by Organon, the Netherlands) and the radioimmunoassay (with the use of an experimental assay kit provided by the Institute of Vaccines in Dessau, GDR) has been carried out by the determination of HBsAg in 100 coded sera from viral hepatitis patients and hepatitis virus carriers. Both passive hemagglutination tests (Sero-Test CCB and Hepanostikon) have yielded coinciding results (r = 0.90). The sensitivity of Sero-Test CCB has been found to exceed that achieved with the use of electrophoretic techniques 30-150 times, though it is 8 times lower than the sensitivity of the radioimmunoassay. The test kits Sero-Test CCB HBsAg are used for the examination of donor blood and for the survey of groups of persons subjected to a high risk of contacting hepatitis B infection in hemodialysis and transplantation centers, surgical wards, etc.  相似文献   

19.
Abstract

Detection of fingermarks at a crime scene or on related items is of prime interest for forensic investigators, mainly for identification purposes. Most of the fingermarks are invisible to the naked eye, however. The application of detection techniques is required to establish visual contrast between the secretion residue and the underlying substrate. We give here a review of the field related to the concept of using stains to detect fingermarks. A distinction has been made between the physically driven classical detection techniques, the chemically driven ones, and those based on nanostructured materials, an emerging field in forensic science.  相似文献   

20.
The determination of the post-mortem interval (PMI) of skeletal remains is a challenging aspect in the forensic field. Previous studies focused their attention on different macroscopic and morphological aspects but a thorough and complete evaluation of the potential of chemical and physical analyses in this field of research has not been performed. In addition to luminol test and Oxford histology index (OHI) reported in a recent paper, widely spread and accessible methods based on physical aspect and chemical characteristics of skeletal remains have been investigated as potential alternatives to dating by determination of 14C.The investigation was performed on a total of 24 archeological and forensic bone samples with known PMI, with inductively coupled plasma optical emission spectrometer (ICP-OES), inductively coupled plasma quadruple mass spectrometry (ICP-MS), Fourier transform infrared (FT-IR) spectroscopy, energy dispersive X-ray analysis (EDX), powder X-ray diffraction analysis (XRPD) and scanning electron microscopy (SEM). Finally, the feasibility of such alternative methods was discussed. Some results such as carbonates/phosphates ratio from FT-IR, the amounts of organic and inorganic matter by EDX, crystallite sizes with XRPD, and surface morphology obtained by SEM, showed significant trends along with PMI. Though, from a chemical point of view cut-off values and gold-standard methods still present challenges, and rather different techniques together can provide useful information toward the assessment of the PMI of skeletal remains. It is however clear that in a hypothetical flowchart those methods may be placed practically at the same level and a choice should always consider the evaluation of results by each technique, execution times and a costs/benefits relationship.  相似文献   