共查询到20条相似文献,搜索用时 0 毫秒
1.
J.W.C. Alffenaar A.M.A. WesselsK. van Hateren B. GreijdanusJ.G.W. Kosterink D.R.A. Uges 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):39-44
Fungal infections occur in immunocompromised patients. Azole antifungal agents are used for the prophylaxis and treatment of these infections. The interest in therapeutic drug monitoring azole agents has increased over the last few years. Inter- and intra-patient variability of pharmacokinetics, drug–drug interactions, serum concentration related toxicity and success of therapy has stressed the need of frequently therapeutic drug monitoring of the drugs, belonging to the group of azoles. Therefore a simple, rapid and flexible method of analysis is required. This method is based on the precipitation of proteins in human serum with LC/MS/MS detection. Validation was performed according to the guidelines for bioanalytical method validation of the food and drug administration agency. The four most used azole drugs can be detected in human serum within the clinical relevant serum levels with good accuracy and reproducibility at the limit of quantification. Intra- and inter-day validation demonstrated good accuracy and reproducibility. A rapid, sensitive and flexible LC/MS/MS method has been developed and validated to measure voriconazole (VRZ), fluconazole (FLZ), itraconazole (ITZ) and posaconazole (PSZ) in human serum. This new method is suitable for clinical pharmacokinetic studies and routine monitoring in daily practice. 相似文献
2.
d-Serine is an endogenous modulator of N-methyl-d-aspartate (NMDA) receptors. Plasma concentrations of d-serine and the ratio of d-serine to total serine may be used as clinically-translatable biomarkers in NMDA receptor-related disease. We developed a highly sensitive and specific method using high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the d- and l-isomers of serine in human plasma. Since d- and l-serine are endogenous components, phosphate buffered saline was used as the surrogate matrix. d- and l-serine in human plasma and PBS were treated by cationic exchange solid phase extraction. d-Serine (m/z 106.1 > 60.0), l-serine (m/z 106.1 > 60.1) and dl-serine-d3 (m/z 109.1 > 63.0) were detected using a multiple reaction monitoring. The enantiomer separation of d- and l-serine was successfully achieved without any derivatization step using tandemly-arranged and ice-cold CROWNPAK CR-I(+) columns with an isocratic mobile phase comprised of 0.3% trifluoroacetic acid in 10% acetonitrile. The standard curves were linear throughout the calibration range with 0.01–10 μg/mL (d-serine) and 0.1–100 μg/mL (l-serine), respectively. Intra-day and inter-day precision and accuracy of the quality control samples were within relative standard deviations of less than 15%. The endogenous concentrations of d- and l-serine in human plasma were 0.124–0.199 and 7.97–13.1 μg/mL, respectively. 相似文献
3.
Geng-Nan Wang Rui-Le Pan Yong-Hong Liao Ying Chen Jing-Tian Tang Qi Chang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):102-106
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%. 相似文献
4.
HPLC-DAD和LC-MS/MS法对各种芦荟样品中蒽醌类成分的分析研究 总被引:1,自引:0,他引:1
采用HPLC-DAD和LC-MS/MS对各种芦荟样品中蒽醌类成分进行鉴定,在此基础上建立了同时测定各种芦荟样品中芦荟苷与芦荟大黄素含量的方法。采用Nucleodur-silica色谱柱(250mm*4.6mm,5μm),流动相A为甲醇-醋酸(500:1.70),B为水.醋酸(500:1.70),梯度洗脱,流速1.0mL/min,DAD扫描波长范围为190~370nm,紫外检测波长为254和356nm。质谱离子源为ESI,采用全扫描一级质谱和选择离子全扫描二级质谱两种方式同时测定。结果表明:各种芦荟样品中主要的蒽醌类成分为芦荟苷A、B与芦荟大黄素,未检测到大黄素、大黄酸、大黄素甲醚、大黄酚;芦荟干粉中所含的芦荟苷含量最高。该法准确、可靠、重现性好,可行性高。 相似文献
5.
目的:建立液相色谱串联质谱同位素内标法检测神经递质类氨基酸并用于癫痫患者临床评价。方法:选用AAA-C18柱色谱柱,以乙腈水(含有0.01%七氟丁酸、0.1%甲酸)为流动相,采用梯度洗脱进行分离,血浆样品用iTRAQ-115衍生化试剂处理后,加入iTRAQ-114衍生化的氨基酸内标并进样,选用3200QTRAP型质谱仪的多重反应监测(MRM)扫描方式进行检测。疾病组与健康组的统计采用t检验和主成份分析。结果:疾病组和健康组氨基酸测定结果显示:Trp、GABA两组间没有显著性差异(P〉0.05),Arg、Gly、Ser、Tau、Asp、Glu、EtN、两组间有显著性差异(P〈0.05),通过PCA分析显示,疾病组与健康组之间差异明显,Asp、Glu、Ser等是引起差异的主要氨基酸。结论:试验方法灵敏、专属性强,并初步的用于癫痫患者体内氨基酸评价。 相似文献
6.
Chikh K Chik K Flourie F Arab K Steghens JP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,827(1):32-38
gamma-Glutamylcysteine ligase (GCL) combines cysteine and glutamate through its gamma carboxyl moiety as the first step for glutathione (GSH) synthesis and is considered to be the rate-limiting enzyme in this pathway. The enzyme is a heterodimer, with a heavy catalytic and a light regulatory subunit, which plays a critical role in the anti-oxidant response. Besides the original method of Seelig designed for the measurement of a purified enzyme, few endpoint methods, often unrefined, are available for measuring it in complex biological samples. We describe a new, fast and reliable kinetic LC/MS method which enabled us to optimize its detection. l-2-Aminobutyrate is used instead of cysteine (to avoid glutathione synthetase interference) as triggering substrate with saturating concentrations of glutamate and ATP; the gamma glutamylaminobutyrate formed is measured at m/z=233 at regular time intervals. Reaction rate is maximum because ATP is held constant by enzymatic recycling of ADP by pyruvate kinase and phosphoenolpyruvate. The repeatability of the method is good, with CV% of 6.5 and 4% for catalytic activities at, respectively 0.9 and 34 U/l. The affinities of rat and human enzymes for glutamate and aminobutyrate are in good agreement with previous published data. However, unlike the rat enzyme, human GCL is not sensitive to reduced glutathione and displays a more basic optimum pH. 相似文献
7.
Bitna Yi Changsung Kim Mihi Yang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(27):2606-2610
Biological monitoring is a necessary process for risk assessment of endocrine disrupting chemicals (EDCs), particularly, bisphenol A (BPA), in breast milk, because its human risks are not clear yet, and infants, who feed on breast milk, are highly susceptible for EDCs. Concerning biological monitoring of BPA, the HPLC/FLD has been widely used before the LC/MS/MS. However, there was no report, which simultaneously evaluated the two methods in real analyses. Therefore, we analyzed BPA with LC/MS/MS and HPLC/FLD in human breast milk and conducted comparison of two methods in analyzed BPA levels. After establishing optimal condition, e.g. linearity, recovery, reproducibility and free BPA system, we analyzed BPA levels in human breast milk samples (N = 100). The LOQs were similar in the two methods, i.e. 1.8 and 1.3 ng/mL for the HPLC/FLD and LC/MS/MS assays, respectively. There were strong associations between total BPA levels with the two methods (R2 = 0.40, p < 0.01), however, only 11% of them were analyzed as similar levels with 15% CVs. In addition, the detection range of BPA was broader in the HPLC method than the LC/MS/MS method. However, the BPA levels in the HPLC/FLD analysis were lower than those in the LC/MS/MS analysis (p < 0.01). Thus, the differences in BPA levels between the two methods may come from mainly over-estimation with the LC/MS/MS method in low BPA samples and some of poor resolution with the HPLC/FLD in high BPA samples. 相似文献
8.
Fernandes RM Gomes GC Porcari AM Pimentel JR Porciúncula PM Martins-Júnior HA Miguez PH da Costa JL Amaral PH Perecin F Meurer EC Furtado PV Simas RC Eberlin MN Ferreira CR Madureira EH 《Theriogenology》2011,76(7):1266-1274
Quantitation of progesterone (P4) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P4 in plasma of cattle with no sample derivatization. The quantitation of plasma P4 released from three nonbiodegradable, commercial, intravaginal P4-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P4 kinetics (P > 0.05) whereas results of P4 quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P4 limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P4 quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. 相似文献
9.
目的:建立人血浆中伊伐布雷定的液相色谱-质谱-质谱联用测定方法,研究健康人体药代动力学。方法:以地西泮为内标物,采用液相色谱-质谱-质谱联用法,电喷雾电离源选择性正离子峰检测。测30名健康志愿者单剂量口服盐酸伊伐布雷定片的体内血药浓度,获得药动学参数。结果:伊伐布雷定在0.101-101 ng·mL-1浓度范围内呈良好的线性关系(r=0.998),最低检测浓度为0.101 ng·mL-1。高、中、低浓度的方法提取回收率分别为93.2%、86.6%、87.5%,日内、日间精密度RSD均小于15%。结论:LC-MS/MS方法灵敏度高,专属性强,准确,简便,适用于盐酸伊伐布雷定片的人体药代动力学研究。 相似文献
10.
目的:采用液相色谱-串联质谱法(LC-MS/MS)分析人支气管上皮细胞与烟曲霉共培养模型中胶霉毒素的含量。方法建立人支气管上皮细胞与烟曲霉共培养模型并于不同时间段检测共培养模型中胶霉毒素的含量。以支气管上皮细胞单独培养为对照组,分别于12h、24h、36h收集对照组、AF293(烟曲霉标准株)共培养组、AFB5233WT(烟曲霉野生株)及AFB5233ΔGlip(烟曲霉胶霉毒素基因敲除株)共培养组细胞培养上清液,采用LC-MS/MS检测胶霉毒素的含量。结果共培养模型中胶霉毒素水平随培养时间增加而逐渐升高(P〈005),胶霉毒素回收率为687%~726%。结论该方法快速、灵敏、结果准确,适用于测定人支气管上皮细胞与烟曲霉共培养模型中胶霉毒素的含量。 相似文献
11.
Tracie L Williams Steven R Monday Peter C H Feng Steven M Musser 《Journal of biomolecular techniques》2005,16(2):134-142
We have investigated the use of a top-down liquid chromatography/mass spectrometric (LC/MS) approach for the identification of specific protein biomarkers useful for differentiation of closely related strains of bacteria. The sequence information derived from the protein biomarker was then used to develop specific polymerase chain reaction primers useful for rapid identification of the strains. Shiga-toxigenic Escherichia coli (STEC) strains were used for this evaluation. The expressed protein profiles of two closely related serotype 0157:H7 strains, the predominant strain implicated in illness worldwide, and the nonpathogenic E. coli K-12 strain were compared with each other in an attempt to identify new protein markers that could be used to distinguish the 0157:H7 strains from each other and from the E. coli K-12 strain. Sequencing of a single protein unique to one of the 0157:H7 strains identified it as a cytolethal distending toxin, a potential virulence marker. The protein sequence information enabled the derivation of genetic sequence information for this toxin, thus allowing the development of specific polymerase chain reaction primers for its detection. In addition, the top-down LC/MS technique was able to identify other unique biomarkers and differentiate nearly identical 0157:H7 strains, which exhibited identical phenotypic, serologic, and genetic traits. The results of these studies demonstrate that this approach can be expanded to other serotypes of interest and provide a rational approach to identifying new molecular targets for detection. 相似文献
12.
13.
A selective, sensitive, and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of aripiprazole and its active metabolite dehydroaripiprazole in human plasma has been developed using papaverine as internal standard (IS). LC-MS/MS analysis was carried out on a Finnigan LC-TSQ Quantum mass spectrometer using positive ion electrospray ionization (ESI+) and selected reaction monitoring (SRM). The assays for aripiprazole and dehydroaripiprazole were linear over the ranges of 0.1 to 600 ng/ml and 0.01 to 60 ng/ml, respectively. The average recoveries in plasma samples both were better than 85%. The intra- and interrun precision and accuracy values were found to be within the assay variability criteria limits according to the US Food and Drug Administration guidelines. The developed method was proved to be suitable for use in a clinical pharmacokinetic study after a single oral administration of a 5-mg aripiprazole tablet in healthy Chinese volunteers. 相似文献
14.
F. Baumann R. Regenthal I.L. Burgos-Guerrero U. Hegerl R. Preiss 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):107-111
As part of a joint clinical research project to study the effects of nicotine on the brain, a HPLC electrospray ionisation mass spectrometry method with a solid-phase extraction sample preparation was developed for the quantitative determination of nicotine and cotinine in human serum in volunteers. The measured concentrations of nicotine and cotinine were used as control for smoking behaviour. A X-Bridge-column from Waters, and a SSQ 7000 single quadropole mass spectrometer with a TSP liquid chromatographic system were used. The method includes a simple and robust sample preparation and this assay has been shown to be of a sufficient sensitivity for this application. The limits of quantification were 5 and 2 ng/ml for cotinine and nicotine, respectively. A simultaneous study was conducted to measure nicotine receptor availability and the vigilance in the same group of volunteers. 相似文献
15.
Medvedovici A Albu F Georgita C Sora DI Galaon T Udrescu S David V 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):327-335
Bioequivalence data for two pharmaceutical formulations (solid oral dosage forms) containing carvedilol is presented for both racemic and enantiomers of the active substance. This was achieved by on-line coupling of two liquid chromatographic separations followed by fluorescence detection. The first LC dimension was used for a fast separation of racemic carvedilol from propranolol (IS) and the endogenous matrix, by means of a reversed phase mechanism. The peak of racemic carvedilol was on-line transferred to the second enantioselective LC dimension, based on a reversed phase separation on cellulose tris(3,5-dimethyl-phenylcarbamate) stationary phase. Both stages were monitored over a single run by means of a fluorescence detector operated at an excitation wavelength of 285 nm and an emission wavelength of 355 nm. Automated shortcutting of the racemic carvedilol peak to the chiral column and simultaneous detection over the two LC dimensions have been obtained by using an experimental set-up based on two six-port rotative switching valves. Linearity was demonstrated on the interval 2-150 ng/mL for racemic carvedilol and on 1-75 ng/mL intervals for enantiomers. LLOQ fits between 0.7 and 1.4 ng/mL. Recoveries of the target compounds are 87+/-4 and 81+/-4% for the IS. Precision ranged from 0.6 to 2.5% and the mean accuracy obtained on quality control samples (measured as % bias) over the whole study falls between -0.8 and 6.3%. 相似文献
16.
C. Dall’Asta S. Sforza A. Moseriti G. Galaverna A. Dossena R. Marchelli 《Mycotoxin Research》2005,21(4):218-223
Zearalenone is a mycotoxin mainly produced by severalFusarium species, which are known to colonize grains in temperate climates. The purpose of the study is to provide a reliable isotope
dilution method for the quantification of this mycotoxin. A derivative of the analyte to be used as standard is obtained by
reaction with acetic anhydride, which is available in two pure isotopic forms, a protonated (“light”) and a hexadeuterated
(“heavy”). The derivatized standards are added to the matrix split intwo parts. Then, the derivatization procedure is repeated
on both matrices derivatizing the part containing the “heavy” labelled standard with the “light” acetic anhydride and the
part containing the “light” labelled standard with the “heavy” acetic anhydride. Both extracted mixtures are analyzed by LC/MS,
monitoring the “light” and the “heavy” labelled analytes and using the former as standard for the latter in one case and viceversa
in the other case. The method allowed to obtain very good results, without the need of IAC purification.
Presented at the 27th Mykotoxin-Workshop, Dortmund, Germany, June 13–15, 2005.
Financial support: The Italian Ministry of Health 相似文献
17.
《Bioscience, biotechnology, and biochemistry》2013,77(11):2676-2681
A highly sensitive and selective analytical method was developed to determine levels of acetyl-CoA and malonyl-CoA in plant tissues. The analytical method includes a convenient extraction method for plant samples and a new LC-MS/MS technique utilizing an ion pair reagent. These acyl-CoAs, present in germinating rice seeds, were then determined by the method developed. It was found that the concentrations of both acetyl-CoA and malonyl-CoA increased with time during the germination of rice seeds and also increased at the elevated cultivation temperatures among tested. These results reflect the development of enzymes that produce these acyl-CoAs in germinating rice seeds. 相似文献
18.
New highly sensitive, specific, reliable, reproducible and robust LC-MS/MS methods were developed to detect the anabolic steroids, nandrolone and stanozolol, in human hair for the first time. Hair samples from 180 participants (108 males, 72 females, 62% athletes) were screened using ELISA which revealed 16 athletes as positive for stanozolol and 3 for nandrolone. Positive samples were confirmed on LC-MS/MS in selective reaction monitoring (SRM) mode. The assays for stanozolol and nandrolone showed good linearity in the range 1-400 pg/mg and 5-400 pg/mg, respectively. The methods were validated for LLOD, interday precision, intraday precision, specificity, extraction recovery and accuracy. The assays were capable of detecting 0.5 pg stanozolol and 3.0 pg nandrolone per mg of hair, when approximately 20 mg of hair were processed. Analysis using LC-MS/MS confirmed 11 athletes’ positive for stanozolol (5.0 pg/mg to 86.3 pg/mg) and 1 for nandrolone (14.0 pg/mg) thus avoiding false results from ELISA screening. The results obtained demonstrate the application of these hair analysis methods to detect both steroids at low concentrations, hence reducing the amount of hair required significantly. The new methods complement urinalysis or blood testing and facilitate improved doping testing regimes. Hair analysis benefits from non-invasiveness, negligible risk of infection and facile sample storage and collection, whilst reducing risks of tampering and cross-contamination. Owing to the wide detection window, this approach may also offer an alternative approach for out-of-competition testing. 相似文献
19.
Nianbai Fang Shanggong Yu Martin JJ Ronis Thomas M Badger 《Experimental biology and medicine (Maywood, N.J.)》2015,240(4):488-497
High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt. 相似文献
20.
Differential expression analysis of Escherichia coli proteins using a novel software for relative quantitation of LC-MS/MS data 总被引:2,自引:0,他引:2
Johansson C Samskog J Sundström L Wadensten H Björkesten L Flensburg J 《Proteomics》2006,6(16):4475-4485
The study of changes in protein levels between samples derived from cells representing different biological conditions is a key to the understanding of cellular function. There are two main methods available that allow both for global scanning for significantly varying proteins and targeted profiling of proteins of interest. One method is based on 2-D gel electrophoresis and image analysis of labelled proteins. The other method is based on LC-MS/MS analysis of either unlabelled peptides or peptides derived from isotopically labelled proteins or peptides. In this study, the non-labelling approach was used involving a new software, DeCyder MS Differential Analysis Software (DeCyder MS) intended for automated detection and relative quantitation of unlabelled peptides in LC-MS/MS data.Total protein extracts of E. coli strains expressing varying levels of dihydrofolate reductase and integron integrase were digested with trypsin and analyzed using a nanoscale liquid chromatography system, Ettan MDLC, online connected to an LTQTM linear ion-trap mass spectrometer fitted with a nanospray interface. Acquired MS data were subjected to DeCyder MS analysis where 2-D representations of the peptide patterns from individual LC-MS/MS analyses were matched and compared.This approach to unlabelled quantitative analysis of the E. coli proteome resulted in relative protein abundances that were in good agreement with results obtained from traditional methods for measuring protein levels. 相似文献