首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Dhawan S 《Peptides》2002,23(12):2099-2110
Spherical polystyrene microparticles expressing a large number of highly reactive functional groups were chemically engineered to generate antibody–enzyme conjugates as novel signal amplification systems. Chemically modified goat anti-human IgG and horseradish peroxidase (HRP) were combined in a 1:5 ratio and attached to 0.44 μm streptavidin microparticles or N-succinimidyl-S-acetylthioacetate (SATA)-activated 0.29 μm amino microparticles with highly reactive free sulfhydryl groups on their surface. The numbers of HRP molecules/microparticle were further increased by coupling HRP to primary amines on N-terminal biotinylated or bromoacetylated polypeptides containing 20 lysine residues prior to conjugation with streptavidin or sulfhydryl groups-containing microparticles. The antibody–poly-HRP immunoconjugates contained an estimated number of 105 HRP/streptavidin microparticle and 106 HRP/amino microparticle, respectively. These microparticle immunoconjugates efficiently bound to plasma anti-HIV-1 antibodies that had been captured by HIV antigens on 5 μm carboxyl magnetic microparticles and, upon reaction with orthophenyldiamine substrate, produced a detection signal with 5–8 times more sensitivity as compared to conventional HRP-conjugated goat anti-human IgG. The signal amplification technique by microparticle immunoconjugates may provide potentially novel tools for the development of highly sensitive diagnostic systems.  相似文献   

2.
Among the methods used to detect pathogenic bacteria, enzyme linked immunosorbent assay (ELISA) is one of the most widely used techniques in routine sample analysis. For Salmonella enterica serovar Typhimurium detection, a typical ELISA yields a sensitivity of 10(6)-10(7)CFU/ml. To enhance the detection sensitivity, single-walled carbon nanotubes (SWCNTs) was employed in this study as a labelling platform for antibody and horseradish peroxidase (HRP) co-immobilizing. With high proteins recovery after the coupling process, the resulting Ab/SWCNTs/HRP bioconjugate was used in the proof-of-concept ELISA experiments. Limit of detection (LOD) was found to be 10(3) and 10(4)CFU/ml for direct and sandwich ELISA, respectively, when Ab/HRP at 1:400 ratio was used. This figure accounts for 1000-time greater in detection sensitivity when compared to a commercial Ab-HRP conjugate. The Ab/SWCNTs/HRP bioconjugate was tested further in real samples and found a superior activity over the commercial Ab-HRP by showing 100-time greater detection limit.  相似文献   

3.
酶标免疫测定法(ELISA)中最关键的化合物是酶-抗体结合物,将酶和抗体交联起来需用交联剂。本文作者使用了N-琥珀酰亚胺基3-(2-吡啶基二硫)丙酸酯(简称SPDP)将辣根过氧化物酶(HRP)和兔抗小鼠IgG(兔IgG)交联起来。我们试验了SPDP/HRP,SPDP/IgG和HRP/IgG的不同比例,以期获得活性高的酶-抗体结合物。此外还研究了从结合物中去除自由HRP和自由IgG的方法。用SDS-PAGE及硝酸纤维膜电泳转移法证明本法制备的结合物不含HRP及IgG的自身聚合物。用ELISA法鉴定结合物制品时,一般稀释度可达到1:10,000以上,有的可达到1:20,000(当结合物浓度A_(280nm)=1.0,底物显色A_(492nm)=1.0时)。  相似文献   

4.
Dhawan S 《Peptides》2002,23(12):1239-2098
Immunoconjugates are widely used for indirect detection of analytes (such as antibodies or antigens) in a variety of immunoassays. However, the availability of functional groups such as primary amines or free sulfhydryls in an immunoglobulin molecule is the limiting factor for optimal conjugation and, therefore, determines the sensitivity of an assay. In the present study, an N-terminal bromoacetylated 20 amino acid peptide containing 20 lysine residues was conjugated to N-succinimidyl-S-acetylthioacetate (SATA)-modified IgG or free sulfhydryl groups on 2-mercaptoethylamine (2-MEA)-reduced IgG molecules via a thioether (S---CH2CONH) linkage to introduce multiple reactive primary amines per IgG. These primary amines were then covalently coupled with maleimide-activated horseradish peroxidase (HRP). The poly-HRP–antibody conjugates thus generated demonstrated greater than 15-fold signal amplification upon reaction with orthophenyldiamine substrate. The poly-HRP–antibody conjugates efficiently detected human immunodeficiency virus (HIV)-1 antibodies in plasma specimens with significantly higher sensitivity than conventionally prepared HRP–antibody conjugates in an HIV-1 solid-phase enzyme immunoassay and Western blot analysis. The signal amplification techniques reported here could have the potential for development of highly sensitive immunodiagnostic assay systems.  相似文献   

5.
In this study, we applied tyramide signal amplification (TSA) to fluorescence enzyme-linked immunosorbent assay (ELISA) employing horseradish peroxidase (HRP) as the detection enzyme. When used with a human epidermal growth factor ELISA kit, the TSA method led to a >100-fold increase in fluorescence signal intensity in comparison to an unamplified method. It also showed wider dynamic range and better sensitivity compared to a conventional method using tetramethylbenzidine as the HRP substrate.  相似文献   

6.
Sensitive sandwich enzyme-linked immunosorbent assay (ELISA) systems for the quantification of 3 pathogenic factors of Pseudomonas aeruginosa-alkaline proteinase (aeruginolysin), elastase (pseudolysin ), and exotoxin A-were developed. The maleimide-pyridyl disulfide method was applied for the labeling of rabbit anti-each antigen IgG with horseradish peroxidase (HRP) and the conjugates were used as secondary antibodies (detection antibodies) in the ELISA systems. The EDTA, a chelating agent, was added to the buffers for sample and detection antibody, which inhibited the degradation of IgG by elastase derived from P. aeruginosa for improving the assay precision. The ELISA systems using the HRP-labeled detection antibodies produced by the maleimide-pyridyl disulfide method exhibited higher sensitivity than previously reported methods. The detection limits for alkaline proteinase, elastase, and exotoxin A were 18 pg/ml, 34 pg/ml, and 22 pg/ml, respectively. The intra-assay coefficients of variation for alkaline proteinase, elastase, and exotoxin A were 3.4%-5.0%, 1.9%-3.5%, and 1.3%-5.4%, respectively. These ELISA systems exhibited good inter-assay precision, non-cross-reactivity, dilution linearity, and recovery . Employing these ELISA systems, we revealed that pathogenic factor concentrations were different among the P. aeruginosa strains tested, which may relate to the different pathogenicity of each strain.  相似文献   

7.
Activation of p53 by conjugation to the ubiquitin-like protein SUMO-1   总被引:26,自引:0,他引:26       下载免费PDF全文
The growth-suppressive properties of p53 are controlled by posttranslational modifications and by regulation of its turnover rate. Here we show that p53 can be modified in vitro and in vivo by conjugation to the small ubiquitin-like protein SUMO-1. A lysine residue at amino acid position 386 of p53 is required for this previously undescribed modification, strongly suggesting that this lysine residue serves as the major attachment site for SUMO-1. Unlike ubiquitin, attachment of SUMO-1 does not appear to target proteins for rapid degradation but rather, has been proposed to change the ability of the modified protein to interact with other cellular proteins. Accordingly, we provide evidence that conjugation of SUMO-1 to wild-type p53 results in an increased transactivation ability of p53. We suggest that posttranslational modification of p53 by SUMO-1 conjugation provides a novel mechanism to regulate p53 activity.  相似文献   

8.
This paper describes the development of an immunosensor coupled to glassy carbon electrode (GCE) modified with multiwall carbon nanotubes (MWCNT) (CNT-GCE) integrated with microfluidic systems for rapid and sensitive quantification of prostate specific antigen (PSA) in human serum samples. Mouse monoclonal (5G6) to PSA antibodies were immobilized on a rotating disk. PSA in the serum sample are allowed to react immunologically with the immobilized anti-tPSA and horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to PSA. HRP, in the presence of hydrogen peroxide (H(2)O(2)) catalyzes the oxidation of 4-tert-butylcatechol (4-TBC), whose back electrochemical reduction was detected on CNT-GCE at -0.15 V. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.08 and 0.5 microg L(-1), respectively and the intra- and inter-assay coefficients of variation were below 4.5%. The electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows potential for detecting PSA in clinical diagnosis.  相似文献   

9.
The bifunctional compound, ethylene-glycol bis(N-hydroxysuccinimidylsuccinate) (EGNHS), stabilizes horseradish peroxidase C (HRP) by reaction with the enzyme's lysine residues. In this study we compare native and modified HRP by proteolytic fragmentation, peptide sequencing, and mass spectroscopy, and identify the sites of modification. Most significantly, EGNHS is shown to form a crosslink between Lys232 and Lys241 of HRP and modifies Lys174 without formation of a crosslink. These findings are in agreement with the lysine side-chain reactivities predicted from the surface accessibility of the amino groups, and the maximal span of 16 A of the EGNHS crosslinker.  相似文献   

10.
目的酶联免疫吸附测定(ELISA)被广泛用于抗体或抗原的检测,并被视为临床实践中的金标准,可提供相对可靠、灵敏和特异的检测结果。ELISA的本质是抗原与相应抗体之间的特异性相互作用。然而,天然抗体固有的不稳定性是ELISA的一个难以克服的弱点,并可能导致检测结果的重现性差甚至错误的诊断结果。本课题组先前应用构象工程方法开发了一种基于金纳米粒子的人工抗体(简称金抗体)。金抗体可以像天然抗体一样特异性地与抗原相互作用,并且具备远优于天然抗体的稳定性。出色的稳定性使金抗体可能成为天然抗体更好的替代物,用于ELISA中。方法经过必要的优化并与辣根过氧化物酶(HRP)耦联后,制得酶标金抗体10HRP-(Au-400P1),然后用酶标金抗体代替天然酶标抗体用于ELISA检测中。结果通过一系列的实验证明,抗溶菌酶金抗体可用于ELISA特异性检测1~16 mg/L范围内的鸡蛋清溶菌酶(HEWL)样品。结论金抗体可以替代天然抗体用于ELISA检测,并具有优于传统ELISA法的检测准确性和一致性。  相似文献   

11.
Conventional methods, such as gastric biopsy, enzyme-linked immunosorbent assay (ELISA), culture, require a long time for the determination of Helicobacter pylori infections. This study reports an amperometric immunoreactor for rapid and sensitive quantification of human serum immunoglobulin G (IgG) antibodies to H. pylori. Antibodies in the serum sample are allowed to react immunologically with the purified H. pylori antigens that are immobilized on a rotating disk. The bound antibodies are quantified by horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to human IgG. HRP in the presence of hydrogen peroxide catalyzes the oxidation of hydroquinone to p-benzoquinone. The electrochemical reduction back to hydroquinone is detected on a glassy carbon electrode surface at -0.15 V. The electrochemical detection can be done within 1 min, and the analysis time does not exceed 30 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.6 and 1.9 U ml-1, respectively. The amperometric immunoreactors showed higher sensitivity and lower time consumed than did the standard spectrophotometric detection ELISA method. It can also be used for rapid analysis in conventional and field conditions in biological, physiological, and analytical practices.  相似文献   

12.
Antibody–drug conjugates (ADCs) are antibody‐based therapeutics that have proven to be highly effective cancer treatment platforms. They are composed of monoclonal antibodies conjugated with highly potent drugs via chemical linkers. Compared to cysteine‐targeted chemistries, conjugation at native lysine residues can lead to a higher degree of structural heterogeneity, and thus it is important to evaluate the impact of conjugation on antibody conformation. Here, we present a workflow involving native ion mobility (IM)‐MS and gas‐phase unfolding for the structural characterization of lysine‐linked monoclonal antibody (mAb)–biotin conjugates. Following the determination of conjugation states via denaturing Liquid Chromatography‐Mass Spectrometry (LC–MS) measurements, we performed both size exclusion chromatography (SEC) and native IM‐MS measurements in order to compare the structures of biotinylated and unmodified IgG1 molecules. Hydrodynamic radii (Rh) and collision cross‐sectional (CCS) values were insufficient to distinguish the conformational changes in these antibody–biotin conjugates owing to their flexible structures and limited instrument resolution. In contrast, collision induced unfolding (CIU) analyses were able to detect subtle structural and stability differences in the mAb upon biotin conjugation, exhibiting a sensitivity to mAb conjugation that exceeds native MS analysis alone. Destabilization of mAb–biotin conjugates was detected by both CIU and differential scanning calorimetry (DSC) data, suggesting a previously unknown correlation between the two measurement tools. We conclude by discussing the impact of IM‐MS and CIU technologies on the future of ADC development pipelines.  相似文献   

13.
A novel probe based on colloidal gold nanoparticles (AuNPs) modified with goat anti-mouse IgG and horseradish peroxidase (HRP) was synthesized and an enhanced enzyme-linked immunosorbent assay (ELISA) based on the probe was developed. In the assay, the synthesized probe is bound with a monoclonal antibody (McAb) which is competitively bound by coated BSA-ITCBE-Pb(II) on plate and Pb(II) in samples. The HRP, used here for signal amplification catalytically oxidize the substrate and generate optical signals that is related to the concentration of Pb(II) and can be measured spectrophotometrically. For the monodisperse AuNPs having high surface areas, it can be conjugated with more amount of HRP than that of IgG. Therefore, compared with traditional ELISA, the signal amplification of catalytically oxidized substrate was enhanced. The detection limit for this novel modified AuNPs probe-based assay was 9 pg mL(-1). The recoveries obtained by standard Pb(II) addition to real samples, including a commercial mineral water, tap water, and lake water were all from 94.9% to 102.9%. And the coefficient of variation (CV) value of all samples was less than 10%. The results indicated that the enhanced assay gave higher sensitivity and reliable reproducibility. It could provide a general detection format for low-molecular weight contaminants.  相似文献   

14.
A non‐competitive immunoassay based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of luteinizing hormone (LH) in human serum. The work involved the development of separation and CL conditions, allowing for routine analysis of serum samples. In this study, horseradish peroxidase (HRP)‐labelled monoclonal anti‐LH can catalyse the luminol–hydrogen peroxide reaction. The determined LH can react with excessive amount of HRP‐labelled anti‐LH. Within 14 min, free enzyme conjugate and immune complex could be separated in alkaline borate buffer by means of a high voltage (15 kV). To improve sensitivity, a series of measures were adopted, including the choice of para‐iodophenol as a CL enhancer, unique design in detect window. Under the optimal conditions, the calibration curve for LH was established in the concentration range 1–200 mIU/mL and the detection limit was 0.08 mIU/mL. Compared with ELISA, this method decreased the detection limit by about 12 times, and it has been successfully employed in the determination of LH in human serum. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

15.
We have developed a new method for the rapid and sensitive detection of cell-free translation products. Biotinylated lysine is incorporated into newly synthesized proteins by means of lysyl-tRNA that is modified in the epsilon-position. After electrophoresis in a dodecyl sulfate gel and blotting onto nitrocellulose, the translation products can be identified by probing with streptavidin and biotinylated alkaline phosphatase, followed by incubation with a chromogenic enzyme substrate. The non-radioactive labelling by biotin approaches in its sensitivity that obtained by radioactive amino acids. The products are absolutely stable and can be rapidly identified. The new method has been tested with different mRNAs in the cell-free translation systems of wheat germ and reticulocytes. Neither the interaction of secretory proteins with the signal recognition particle nor the in vitro translocation across the endoplasmic reticulum membrane or core glycosylation of nascent polypeptides are prevented by the incorporation of biotinylated lysine residues. The results indicate that both the ribosome and the endoplasmic reticulum membrane permit the passage of polypeptides carrying bulky groups attached to the amino acids (by atomic models it was estimated that the size of the side chain of lysine changes from approximately equal to 0.8 nm to approximately equal to 2 nm after modification.  相似文献   

16.
17.
Tissue culture techniques are inadequate to diagnose some viral infections. Thus, solid-phase immunoassays have been developed for the direct detection of viral antigens in clinical specimens. While radioimmunoassays (RIA) have attained widespread use, solid-phase enzyme-linked immunosorbent assays (ELISA) offer a number of advantages over RIA systems. ELISAs can be established with approximately the same sensitivity as radioimmunoassays without utilizing unstable, gamma-emitting isotopes. However, before ELISA systems can obtain widespread usage, a number of aspects of the test must be optimized. These include the preparation and use of reagents, the nature of the solid phase, the choice of enzyme, and the enzyme-antibody conjugation method. With the solving of these problems, ELISA should attain widespread usage for rapid diagnosis of a large number of infectious agents.  相似文献   

18.
目的建立两种甲型肝炎病毒抗原(HAV-Ag)检测试剂盒,并对其检测效果进行评价。方法生物素标记甲型肝炎病毒抗体(HAV-Ab)与辣根过氧化物酶标记亲和素联合应用建立甲型肝炎病毒抗原BA-ELISA检测法;同时使用辣根过氧化物酶标记HAV-Ab作放大系统建立双抗体夹心甲型肝炎病毒抗原ELISA检测试剂,对比两种检测方法的特异性、灵敏度及实际应用效果。结果用生物素标记甲型肝炎病毒抗体-辣根过氧化物酶标记亲和素作放大系统建立的甲型肝炎病毒抗原BA-ELISA检测法,较双抗体夹心ELISA检测方法灵敏度高1~2个稀释度;两种检测法均对10余种病毒无交叉,P/N值BA-ELISA检测法较高。结论甲型肝炎病毒抗原BA-ELISA检测法是一种灵敏度高,特异性好,方便快捷的检测方法,可广泛应用于甲型肝炎病毒研究及临床检测中。而甲型肝炎病毒抗原双抗体夹心ELISA检测法,检测灵敏度适中,操作简单,更适用于甲肝疫苗生产检定。  相似文献   

19.
Conjugation of either a fluorescent dye or a drug molecule to the ε-amino groups of lysine residues of proteins has many applications in biology and medicine. However, this type of conjugation produces a heterogeneous population of protein conjugates. Because conjugation of fluorochrome or drug molecule to a protein may have deleterious effects on protein function, the identification of conjugation sites is necessary. Unfortunately, the identification process can be time-consuming and laborious; therefore, there is a need to develop a rapid and reliable way to determine the conjugation sites of the fluorescent label or drug molecule. In this study, the sites of conjugation of fluorescein-5'-isothiocyanate and rhodamine-B-isothiocyanate to free amino groups on the insert-domain (I-domain) protein derived from the α-subunit of lymphocyte function-associated antigen-1 (LFA-1) were determined by electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-Q-TOF MS) along with peptide mapping using trypsin digestion. A reporter fragment of the fluorochrome moiety that is generated in the collision cell of the Q-TOF without explicit MS/MS precursor selection was used to identify the conjugation site. Selected ion plots of the reporter ion readily mark modified peptides in chromatograms of the complex digest. Interrogation of theses spectra reveals a neutral loss/precursor pair that identifies the modified peptide. The results show that one to seven fluorescein molecules or one to four rhodamine molecules were attached to the lysine residue(s) of the I-domain protein. No modifications were found in the metal ion-dependent adhesion site (MIDAS), which is an important binding region of the I-domain.  相似文献   

20.
The use of microarray-based immunoassay is often limited by its sensitivity. To increase the sensitivities of such an immunoassay, liposome encapsulation was explored. Two different liposome formations and several preparation methods were examined to optimize encapsulation and signal-enhancing efficacy for enzyme-linked immunosorbent assay (ELISA) and antibody array. The signal amplification by liposome encapsulation was demonstrated through a detection for foodborne pathogenic Listeria. In plate-trapped antigen (PTA) ELISA, horseradish peroxidase (HRP)-loaded liposome increased signal 9-fold more than the control. Limits of detection (LODs) of HRP-encapsulated liposome were 6.4×10(5) and 5.5×10(6)CFU/ml in sandwich ELISA and antibody array, respectively. Furthermore, when chromogenic 4-chloro-1-naphthol (4-CN) substrate was used for signal development in the antibody array, the signal could be detected with the naked eye. These results suggest that the liposome encapsulation technique can have great potential for signal amplification and, therefore, for increasing assay sensitivity for various formats of immunoassay, especially microarray-based format.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号