首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The preparation of effective conventional antibody microarrays depends on the availability of high quality material and on the correct accessibility of the antibody active moieties following their immobilization on the support slide. We show that spotting bacteria that expose recombinant antibodies on their external surface directly on nanostructured-TiO(2) or epoxy slides (purification-independent microarray - PIM) is a simple and reliable alternative for preparing sensitive and specific microarrays for antigen detection. Variable domains of single heavy-chain antibodies (VHHs) against fibroblast growth factor receptor 1 (FGFR1) were used to capture the antigen diluted in serum or BSA solution. The FGFR1 detection was performed by either direct antigen labeling or using a sandwich system in which FGFR1 was first bound to its antibody and successively identified using a labeled FGF. In both cases the signal distribution within each spot was uniform and spot morphology regular. The signal-to-noise ratio of the signal was extremely elevated and the specificity of the system was proved statistically. The LOD of the system for the antigen was calculated being 0.4ng/mL and the dynamic range between 0.4ng/mL and 10μg/mL. The microarrays prepared with bacteria exposing antibodies remain fully functional for at least 31 days after spotting. We finally demonstrated that the method is suitable for other antigen-antibody pairs and expect that it could be easily adapted to further applications such as the display of scFv and IgG antibodies or the autoantibody detection using protein PIMs.  相似文献   

2.
Immobilized antibody microarrays were compared to the Luminex flow cytometry system that utilizes suspensions of polystyrene microbeads covalently coupled with capture antibodies. The two immunoassays were performed for comparison of reproducibility, limits of detection and dynamic range. The Luminex system showed lower limits of detection and increased dynamic range among samples whereas the protein microarrays could be more amenable to miniaturization. Both technologies were capable of sensitive multiplexed detection.  相似文献   

3.
Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays can simultaneously quantify the levels of multiple diagnostic targets in a biological sample. However, as with traditional ELISA diagnostics, endogenous antibodies in patient sera can cause interference. We demonstrate here that reducing the diagnostic capture antibody to its minimal functional unit (i.e., a single-chain antibody fragment [scFv]) is an effective strategy for reducing assay interference. Our finding illustrates a source of error introduced by the reliance on immunoglobulin-based capture reagents in sandwich immunoassays with human serum samples. We demonstrate that scFvs can be used in such assays to improve reliability by reducing heterophilic antibody interference, thereby improving biomarker analysis and validation.  相似文献   

4.
Antibody microarrays have the potential to revolutionize protein diagnostics. The major problems in the fabrication of antibody arrays, however, concern the reproducibility and homogeneity of the attachment of the proteins on the solid substrate. We here compare the DNA-directed immobilization (DDI) method with two conventional strategies for immobilization of antibodies on glass substrates. DDI is based on the self-assembly of semisynthetic DNA-streptavidin conjugates which converts an array of DNA oligomers into an antibody microarray. DDI was compared with direct spotting of antibodies on chemically activated glass slides and with immobilization of biotinylated antibodies on streptavidin-coated slides. The immobilized antibodies were used as capture reagents in a two-sided (sandwich) immunoassay for the quantification of rabbit IgG as a model antigen. Detection limits down to 0.001nM (150 pg/mL) were attained with all three array formats; however, DDI and direct spotting of the antibodies led to the highest fluorescence intensities. DDI led to the best spot homogeneity and intra- and interexperimental reproducibility. Moreover, DDI allowed highly economical use of antibody materials; that is, at least 100-fold less antibody is needed for preparing an array by DDI instead of by direct spotting. Taking into account the greater versatility and convenience of handling of the self-assembly approach, this study demonstrates that DDI is an advantageous alternative for generating versatile and robust protein arrays.  相似文献   

5.
Quantitative protein profiling using antibody arrays   总被引:4,自引:0,他引:4  
Barry R  Soloviev M 《Proteomics》2004,4(12):3717-3726
Traditional approaches to microarrays rely on direct binding assays where the extent of hybridisation and the signal detected are a measure of the analyte concentration in the experimental sample. This approach, directly imported from the nucleic acid field, may fail if applied to antibody-antigen interactions due to the shortage of characterised antibodies, the significant heterogeneity of antibody affinities, their dependence on the extent of protein modification during labelling and the inherent antibody cross-reactivity. These problems can potentially limit the multiplexing capabilities of protein affinity assays and in many cases rule out quantitative protein profiling using antibody microarrays. A number of approaches aimed at achieving quantitative protein profiling in a multiplex format have been reported recently. Of those reported, the three most promising routes include signal amplification, multicolour detection and competitive displacement approaches to multiplex affinity assays. One in particular, competitive displacement, also overcomes the problems associated with quantitation of affinity interactions and provides the most generic approach to highly parallel affinity assays, including antibody arrays.  相似文献   

6.
Song S  Li B  Wang L  Wu H  Hu J  Li M  Fan C 《Molecular bioSystems》2007,3(2):151-158
Antibody microarrays have shown great potential for measurement of either a spectrum of target proteins in proteomics or disease-associated antigens in molecular diagnostics. Despite its importance, the applications of antibody microarrays are still limited by a variety of fundamental problems. Among them, cross-reactivity significantly limits the multiplexing ability in parallel sandwich immunoassays. As a result, it is very important to design new capture probes in order to incorporate a universal label into the assay configuration. In this report, an antibody fragments (F(ab')2) microarray platform for serum tumor markers was developed. Each antigen was detected at different concentrations to assemble its calibration curve, and combinations of different markers were tested to examine the specificity of simultaneous detection based on the F(ab')2 microarrays. Diagnostics of serum samples with this cancer antibody microarray platform and immunoradiometric assays (IRMA) were also performed. Wide range calibration curves (0-1280 U mL(-1)) were obtained for each tumor marker. Comparative studies demonstrated that such F(ab')2 microarrays exhibited both moderately improved sensitivity and better specificity than full-sized monoclonal antibody microarrays. It is also demonstrated that this microarray platform is quantitative, highly specific and reasonably sensitive. More importantly, clinical applications of our F(ab')2 microarray platform for upwards of 100 patient serum samples clearly show its potential in cancer diagnostics.  相似文献   

7.
BACKGROUND: Measuring antibody production in response to antigen exposure or vaccination is key to disease prevention and treatment. Our understanding of the mechanisms involved in the antibody response is limited by a lack of sensitive analysis methods. We address this limitation using multiplexed microsphere arrays for the semi -quantitative analysis of antibody production in response to malaria infection. METHODS: We used microspheres as solid supports on which to capture and analyze circulating antibodies. Antigen immobilized on beads captured antigen-specific antibodies for semi- quantitative analysis using fluorescent secondary antibodies. Anti-immunoglobulin antibodies on beads captured specific antibody isotypes for affinity estimation using fluorescent antigen. RESULTS: Antigen-mediated capture of plasma antibodies enables determination of antigen-specific antibody "titer," a semi-quantitative parameter describing a convolution of antibody abundance and avidity, as well as parameters describing numbers of antibodies bound/bead at saturation and the plasma concentration-dependent approach to saturation. Results were identical in single-plex and multiplex assays, and in qualitative agreement with similar parameters derived from ELISA-based assays. Isotype-specific antibody-mediated capture of plasma antibodies allowed the estimation of the affinity of antibody for antigen. CONCLUSION: Analysis of antibody responses using microspheres and flow cytometry offer significant advantages in speed, sample size, and quantification over standard ELISA-based titer methods.  相似文献   

8.
Stable isotope standards and capture by antipeptide antibodies (SISCAPA) couples affinity enrichment of peptides with stable isotope dilution and detection by multiple reaction monitoring mass spectrometry to provide quantitative measurement of peptides as surrogates for their respective proteins. In this report, we describe a feasibility study to determine the success rate for production of suitable antibodies for SISCAPA assays in order to inform strategies for large-scale assay development. A workflow was designed that included a multiplex immunization strategy in which up to five proteotypic peptides from a single protein target were used to immunize individual rabbits. A total of 403 proteotypic tryptic peptides representing 89 protein targets were used as immunogens. Antipeptide antibody titers were measured by ELISA and 220 antipeptide antibodies representing 89 proteins were chosen for affinity purification. These antibodies were characterized with respect to their performance in SISCAPA-multiple reaction monitoring assays using trypsin-digested human plasma matrix. More than half of the assays generated were capable of detecting the target peptide at concentrations of less than 0.5 fmol/μl in human plasma, corresponding to protein concentrations of less than 100 ng/ml. The strategy of multiplexing five peptide immunogens was successful in generating a working assay for 100% of the targeted proteins in this evaluation study. These results indicate it is feasible for a single laboratory to develop hundreds of assays per year and allow planning for cost-effective generation of SISCAPA assays.  相似文献   

9.
Cytokines and chemoattractive cytokines (chemokines) are present in a wide variety of body fluids such as plasma, cerebrospinal fluid, bronchoaveolar fluid, amniotic fluid, synovial fluid, middle ear effusion fluid, and urine. Cytokines can be detected using classical solid-phase sandwich immunoassays such as enzyme-linked immunosorbent assay (ELISA) or with a bead based multiplex immunoassay (MIA). The physical chemical properties of the different body fluids (such as pH and total protein content) differ, which may have an impact on the outcome of the cytokine assay. Both ELISA as well as MIA cytokine detection systems are constructed by sandwiching the protein of interest between a capture and reporter antibody. When the biological sample contains heterophilic antibodies (such as in patients with auto-immune diseases), these non-specific antibodies can cause false positive results. During pathological conditions, cytokines may be found over a wide concentration range; likewise have to cover this dynamic range in a similar fashion. The correct (statistical) analysis of standard curves and (multiplexed) data are critical for proper interpretation. Classical ELISA based cytokine assays are robust, easy to use and very well suited for measurement of single cytokines. Due to an increased interest in the integral approach to understand biological processes (the omics era), multiplex immunoassays for detection of cytokines and the interpretation of these assays are gaining popularity.  相似文献   

10.
Evaluation of surface chemistries for antibody microarrays   总被引:1,自引:1,他引:0  
Antibody microarrays are an emerging technology that promises to be a powerful tool for the detection of disease biomarkers. The current technology for protein microarrays has been derived primarily from DNA microarrays and is not fully characterized for use with proteins. For example, there are a myriad of surface chemistries that are commercially available for antibody microarrays, but there are no rigorous studies that compare these different surfaces. Therefore, we have used a sandwich enzyme-linked immunosorbent assay (ELISA) microarray platform to analyze 17 different commercially available slide types. Full standard curves were generated for 23 different assays. We found that this approach provides a rigorous and quantitative system for comparing the different slide types based on spot size and morphology, slide noise, spot background, lower limit of detection, and reproducibility. These studies demonstrate that the properties of the slide surface affect the activity of immobilized antibodies and the quality of data produced. Although many slide types produce useful data, glass slides coated with aldehyde silane, poly-l-lysine, or aminosilane (with or without activation with a crosslinker) consistently produce superior results in the sandwich ELISA microarray analyses we performed.  相似文献   

11.
We constructed miniaturized autoantigen arrays to perform large-scale multiplex characterization of autoantibody responses directed against structurally diverse autoantigens, using submicroliter quantities of clinical samples. Autoantigen microarrays were produced by attaching hundreds of proteins, peptides and other biomolecules to the surface of derivatized glass slides using a robotic arrayer. Arrays were incubated with patient serum, and spectrally resolvable fluorescent labels were used to detect autoantibody binding to specific autoantigens on the array. We describe and characterize arrays containing the major autoantigens in eight distinct human autoimmune diseases, including systemic lupus erythematosus and rheumatoid arthritis. This represents the first report of application of such technology to multiple human disease sera, and will enable validated detection of antibodies recognizing autoantigens including proteins, peptides, enzyme complexes, ribonucleoprotein complexes, DNA and post-translationally modified antigens. Autoantigen microarrays represent a powerful tool to study the specificity and pathogenesis of autoantibody responses, and to identify and define relevant autoantigens in human autoimmune diseases.  相似文献   

12.
《MABS-AUSTIN》2013,5(3):275-284
This paper describes the generation of monoclonal antibodies directed to immunogenic nucleoprotein N epitopes of Rift Valley fever virus (RVFV), and their application in diagnostics, both for antibody detection in competitive ELISA and for antigen capture in a sandwich ELISA. Monoclonal antibodies (mAbs) were generated after DNA immunization of Balb/c mice and characterized by Western blot, ELISA and cell immunostaining assays. At least three different immunorelevant epitopes were defined by mAb competition assays. Interestingly, two of the mAbs generated were able to distinguish between RVFV strains from Egyptian or South African lineages. These monoclonal antibodies constitute useful tools for diagnosis, especially for the detection of serum anti-RVFV antibodies from a broad range of species by means of competitive ELISA.  相似文献   

13.
Subnanoliter enzymatic assays on microarrays   总被引:1,自引:0,他引:1  
Many areas of research today are based on enzymatic assays most of which are still performed as enzyme-linked immunosorbent assays in microtiter plates. The demand for highly parallel screening of thousands of samples eventually led to a miniaturization and automation of these assays. However, the final transfer of enzymatic assays from a microtiter-based technology to microarrays has proven to be difficult for various reasons, such as the inability to maintain unbound reaction products on the spot of reaction or the missing capability of multiplexing. Here, we have conducted multiplex enzymatic assays in subnanoliter volumes on a single microarray using the multiple spotting technology. We were able to measure enzymatic activity with a sensitivity down to 35 enzyme molecules, applying only conventional flat microarray surfaces and standard microarray hardware. We have performed assays of inhibition and applied this format for the detection of prognostic markers, such as cathepsin D. The new approach allows the rapid and multiplex screening of thousands of samples on a single microarray with applications in drug screening, metagenomics, and high-throughput enzyme assays.  相似文献   

14.
Haab BB 《Proteomics》2003,3(11):2116-2122
Antibody microarrays have great potential for significant value in biological research. Cancer research in particular could benefit from the unique experimental capabilities of this technology. This article examines the current state of antibody microarray technological developments and assay formats, along with a review of the demonstrated applications to cancer research. Work is ongoing in the refinement of various aspects of the protocols and the development of robust methods for routine use. Antibody microarray experimental formats can be broadly categorized into two classes: (1) direct labeling experiments, and (2) dual antibody sandwich assays. In the direct labeling method, the covalent labeling of all proteins in a complex mixture provides a means for detecting bound proteins after incubation on an antibody microarray. If proteins are labeled with a tag, such as biotin, the signal from bound proteins can be amplified. In the sandwich assay, proteins captured on an antibody microarray are detected by a cocktail of detection antibodies, each antibody matched to one of the spotted antibodies. Each format has distinct advantages and disadvantages. Several applications of antibody arrays to cancer research have been reported, including the analysis of proteins in blood serum, resected frozen tumors, cell lines, and on membranes of blood cells. These demonstrations clearly show the utility of antibody microarrays for cancer research and signal the imminent expansion of this platform to many areas of biological research.  相似文献   

15.
The Bio-Plex(?) system utilizes xMAP technology to permit the multiplexing of up to 100 different analytes. Multiplex analysis gives researchers the ability to look at analytes simultaneously providing more information from less sample volume in less time than traditional immunoassay methods. Similar to ELISA, xMAP utilizes an antibody sandwich for detection but differs from ELISA in capture substrate and detection method. Rather than a flat surface, Bio-Plex(?) assays make use of differentially detectable bead sets as a substrate capturing analytes in solution and employs fluorescent methods for detection. These bead sets identify the analytes and detection antibodies are used to measure the quantity of analyte. The use of differentially detectable beads enables the simultaneous identification and quantification of many analytes in the same sample.  相似文献   

16.
Carbohydrate post-translational modifications on proteins are important determinants of protein function in both normal and disease biology. We have developed a method to allow the efficient, multiplexed study of glycans on individual proteins from complex mixtures, using antibody microarray capture of multiple proteins followed by detection with lectins or glycan-binding antibodies. Chemical derivatization of the glycans on the spotted antibodies prevented lectin binding to those glycans. Multiple lectins could be used as detection probes, each targeting different glycan groups, to build up lectin binding profiles of captured proteins. By profiling both protein and glycan variation in multiple samples using parallel sandwich and glycan-detection assays, we found cancer-associated glycan alteration on the proteins MUC1 and CEA in the serum of pancreatic cancer patients. Antibody arrays for glycan detection are highly effective for profiling variation in specific glycans on multiple proteins and should be useful in diverse areas of glycobiology research.  相似文献   

17.
DNA‐assisted proteomics technologies enable ultra‐sensitive measurements in multiplex format using DNA‐barcoded affinity reagents. Although numerous antibodies are available, nowadays targeting nearly the complete human proteome, the majority is not accessible at the quantity, concentration, or purity recommended for most bio‐conjugation protocols. Here, we introduce a magnetic bead‐assisted DNA‐barcoding approach, applicable for several antibodies in parallel, as well as reducing required reagents quantities up to a thousand‐fold. The success of DNA‐barcoding and retained functionality of antibodies were demonstrated in sandwich immunoassays and standard quantitative Immuno‐PCR assays. Specific DNA‐barcoding of antibodies for multiplex applications was presented on suspension bead arrays with read‐out on a massively parallel sequencing platform in a procedure denoted Immuno‐Sequencing. Conclusively, human plasma samples were analyzed to indicate the functionality of barcoded antibodies in intended proteomics applications.  相似文献   

18.
Polyclonal antibody sensitive to Listeria was assayed for the detection of Listeria using two different methods, direct and sandwich enzyme linked immunosorbent assays (ELISAs). The direct ELISA uses anti-goat IgG antibody conjugated with horse-radish peroxidase, while the sandwich ELISA uses two antibodies both specific to Listeria antigens, one coated onto the microtitre plate and the other conjugated to horse-radish peroxidase. The results obtained show that the direct ELISA is superior to the sandwich ELISA in two distinct ways: (i) with direct ELISA the non- Listeria gave readings <0.2, whereas with sandwich ELISA it gave readings of 0.3–0.4; (ii) the direct ELISA is more cost-effective than the sandwich ELISA.  相似文献   

19.
Antibody array analysis of complex samples requires capture reagents with exceptional specificity. The frequency of antibodies with label-based detection may be as low as 5%. Here, however, we show that as many as 25% of commercially available antibodies are useful when biotinylated cellular proteins are fractionated by size exclusion chromatography (SEC) first. A microsphere multiplex with 1725 antibodies to cellular proteins was added to 24 SEC fractions, labelled with streptavidin and analyzed by flow cytometry (microsphere-based affinity proteomics, MAP) The SEC-MAP approach resolved different targets captured by each antibody as reactivity peaks across the separation range of the SEC column (10-670kDa). Complex reactivity profiles demonstrated that most antibodies bound more than one target. However, specific binding was readily detected as reactivity peaks common for different antibodies to the same protein. We optimized sample preparation and found that amine-reactive biotin rarely inhibited antibody binding when the biotin to lysine ratio was kept below 1:1 during labelling. Moreover, several epitopes that were inaccessible to antibodies in native proteins were unmasked after heat denaturation with 0.1% of SDS. The SEC-MAP format should allow researchers to build multiplexed assays with antibodies purchased for use in e.g. Western blotting.  相似文献   

20.
A recombinant mouse interleukin-4 (IL-4) and three different purified rat antimouse IL-4 monoclonal antibodies (Mab) with different clonalities were employed as a model system. This system was used to examine monoclonal antibody effectiveness using both conventional and high-throughput measurement techniques to select antibodies for attaining the most sensitive detection of the recombinant IL-4 through the "sandwich-type" immunoassays. Surface plasmon resonance (SPR) measurements and two high-throughput methods, suspension arrays (also called multiplexed bead arrays) and forward-phase protein microarrays, predicted the same capture (BVD4-1D11) and detection (BVD6-24G2) antibody pair for the most sensitive detection of the recombinant cytokine. By using this antibody pair, we were able to detect as low as 2 pg/mL of IL-4 in buffer solution and 13.5 pg/mL of IL-4 spiked in 100% normal mouse serum with the multiplexed bead arrays. Due to the large amount of material required for SPR measurements, the study suggests that the multiplexed bead arrays and protein microarrays are both suited for the selection of numerous antibodies against the same analyte of interest to meet the need in the areas of systems biology and reproducible clinical diagnostics for better patient care.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号