首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The need for analytical screening tests more reliable and valid to detect amphetamine and related "designer drugs" in biological samples is becoming critical, due to the increasing diffusion of these drugs on the European illegal market. The most common screening procedures based on immunoassays suffer a number of limitations, including low sensitivity, lack of specificity and limited number of detectable substances. This paper describes a screening method based on gas-chromatography-mass-spectrometry (GC/MS) using positive chemical ionisation (PCI) detection. Methanol was used as reactant gas in the ionisation chamber. Molecular ions of different compounds were monitored, allowing a sensitivity of 5-10 ng/ml with high selectivity. The sensitivity of the method gives positive results in samples taken 48-72 h after intake of one dose of 50-100 mg. The method is simple and rapid. Sample preparation was limited to one liquid-liquid extraction, without any hydrolysis and derivatisation. Hydrolysis is critical to identify metabolites excreted as conjugates. Blank urine samples spiked with known amounts of amphetamine (AM), methylamphetamine (MA), methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methylenedioxyethylamphetamine (MDEA) and methylenedioxyphenyl-N-methyl-2-butanamine (MBDB) were analysed. The method was successfully tested on real samples of urine from people, whose use of amphetamine was suspected, and results were compared with results obtained with immunoassays.  相似文献   

2.
This paper presents the development of a simple liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to determine corticosteroids in bovine urine sample matrices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9.0–9.5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4.1)/methanol. A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection. The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC–MS/MS analysis. This allowed a reduction the quantification limits (decision limits, CCα) for the first time to 0.1 μg/L (1 and 0.2 μg/L for triamcinolone and flumethasone, respectively). The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107.5%, respectively, at 2, 3, and 4 μg/L levels of corticosteroids. The relative standard deviation (RSD) of the measurements was lower than 30%. The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0.1–1.0 μg/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations. The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1.64 of the within-laboratory reproducibility at 2 μg/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 0.3 to 0.9 μg/L.  相似文献   

3.
A fast and efficient multi-residue extraction–purification procedure was developed for 12 corticosteroids in biological matrices (hair, urine and meat), in order to control their illegal use as growth promoters in cattle. Detection and identification of the analytes were achieved using a previously described LC–MS–MS method based on negative electrospray ionisation and a triple quadrupole analyser. The presented procedures included acid (hair) or enzymatic (urine and meat) hydrolysis, C18 reversed-phase SPE, Na2CO3 liquid–liquid clean-up and SiOH normal-phase SPE. The detection limits of the developed methods were between 2.9 and 9.3 pg/mg (ppb) for hair samples and in the 40 – 70 pg/g (ppt) range for the urine or meat samples. The acid hydrolysis used for corticosteroid extraction in hair was optimised using an experimental design and response surface methodology. Achieved performances were linked to a physico–chemical approach based on the corticosteroids specific C17 side-chain. This original multi-residue and multi-matrices analytical methodology will be used for further metabolism studies.  相似文献   

4.

Background

Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis.

Methodology/Principal Findings

A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%).

Conclusions/Significance

We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas.  相似文献   

5.
The D-/L-arabinitol enantiomers ratio (a marker of disseminated candidiasis of Candida species) in urine was determined by gas chromatography (GC) in 198 healthy Polish children ranging in age from 0 to 18 years. The urine samples were dry and trifluoroacetic anhydride (TFAA)-treated. Enantiomers derivatives were separated on a chiral column (beta-Dex 120, 60 m x 0.25 mm I.D.). A glass "solid-phase" injector and electron capture detector (ECD) were used. The ECD response was linear with correlation coefficients 0.999. The limit of detection was 0.02 micromol/l. Good results in terms of reproducibility, accuracy (RSD<10%, bias<6%), and linearity were obtained from real urine samples containing up to 400 micromol/l D-arabinitol. TFA-arabinitol derivatives in biological samples were stable from 1 to 5 days (depending on the arabinitol contents), while TFA-arabinitol standard derivatives were stable for 2 weeks. The identity of D- and L-arabinitol were confirmed by GC-MS analysis. The mean D-/L-arabinitol ratios ranged from 2.48 to 1.65 in the examined groups. The D-/L-arabinitol ratio was found to be exponentially regressive with age. A few cases of diagnosis of disseminated candidiasis by the GC method and confirmed by blood culture are described. The described GC method was also used for monitoring antifungal treatment of patients with disseminated candidiasis.  相似文献   

6.
The sensitivity and reliability of PCR for diagnostic and research purposes require efficient unbiased procedures of extraction and purification of nucleic acids. One of the major limitations of PCR-based tests is the inhibition of the amplification process by substances present in clinical samples. This study used specimens spiked with a known amount of plasmid pBKV (ATCC 33-1) to compare six methods for extraction and purification of viral DNA from urine and serum samples based on recovery efficiency in terms of yield of DNA and percentage of plasmid pBKV recovered, purity of extracted DNA, and percentage of inhibition. The most effective extraction methods were the phenol/chloroform technique and the silica gel extraction procedure for urine and serum samples, respectively. Considering DNA purity, the silica gel extraction procedure and the phenol/chloroform method produced the most satisfactory results in urine and serum samples, respectively. The presence of inhibitors was overcome by all DNA extraction techniques in urine samples, as evidenced by semiquantitative PCR amplification. In serum samples, the lysis method and the proteinase K procedure did not completely overcome the presence of inhibitors.  相似文献   

7.
Hong CS  Cui J  Ni Z  Su Y  Puett D  Li F  Xu Y 《PloS one》2011,6(2):e16875
A novel computational method for prediction of proteins excreted into urine is presented. The method is based on the identification of a list of distinguishing features between proteins found in the urine of healthy people and proteins deemed not to be urine excretory. These features are used to train a classifier to distinguish the two classes of proteins. When used in conjunction with information of which proteins are differentially expressed in diseased tissues of a specific type versus control tissues, this method can be used to predict potential urine markers for the disease. Here we report the detailed algorithm of this method and an application to identification of urine markers for gastric cancer. The performance of the trained classifier on 163 proteins was experimentally validated using antibody arrays, achieving >80% true positive rate. By applying the classifier on differentially expressed genes in gastric cancer vs normal gastric tissues, it was found that endothelial lipase (EL) was substantially suppressed in the urine samples of 21 gastric cancer patients versus 21 healthy individuals. Overall, we have demonstrated that our predictor for urine excretory proteins is highly effective and could potentially serve as a powerful tool in searches for disease biomarkers in urine in general.  相似文献   

8.
This study evaluated the bioaccumulation and biotransformation of arsenic species in chicken heart and meat tissues. The experimental study was carried out using two sets of samples. In the first one, 10-d-old chickens were exposed to sodium arsenate, using spiked drinking water. These chickens grew normally and were killed after 50 d of arsenic exposure. The second set were edible chickens used as blanks for a parallel study. The total arsenic and arsenic species content in the exposed samples were at least twice those in the normal edible chicken. It has been demonstrated that sodium arsenate is biotransformed to arsenite and an unknown species and its distribution varies among the different cardiac and meat tissues. One important aspect is the capability of the auricle to preconcentrate the most toxic species, arsenite, in the exposed chicken. A nonidentified arsenic species from the edible chicken was detected. Arsenobetaine was also detected in several tissues. This article shows that chicken can be used as a representative animal when considering inorganic arsenic exposure in humans.  相似文献   

9.
Alpha-bisabolol is a compound present in some essential oils, widely distributed in several plants, including camomile. Two different methods for analysing an essential oil, such as alpha-bisabolol in human blood are reported: the first uses micro-liquid chromatography-electrospray ionisation-mass spectrometry (muHPLC-ESI-MS), whereas the second is based on "head space" injection coupled to gas chromatography-mass spectrometry (HS-GC-MS). For LC-ESI-MS, human blood samples, spiked with alpha-bisabolol, were extracted with hexane and evaporated to dryness under air stream. The residue was then reconstituted with methanol and injected into a C18 column, connected to an ion trap mass spectrometer equipped with an ESI source. Spectra were recorded in the positive ion, selected ion monitoring mode. The detection limit of alpha-bisabolol in blood was 0.125 micromol/l. The preparation of samples for the analysis in HS-GC-MS was limited to blood dilution with water (0.5 ml blood + 1 ml water). Head space vials were heated at 125 degrees C for 1 h before automatic injection. The HS-GC-MS detection limit (0.13 micromol/l) was similar to that achieved with the muHPLC-ESI-MS method. Successful tests were performed to verify if alpha-bisabolol could be directly measured by the HS-GC-MS method in different biological samples (blood, urine, faeces, homogenate tissues) from rats treated with the camomile essential oil.  相似文献   

10.
A simple HPLC method has been described to quantify diquat in biological fluids and tissues. This method permits separation and quantification of diquat from blood, bile, urine, liver and kidney. It does not require special pretreatment of the samples prior to analysis, nor a specially prepared analytical column. Various concentrations of diquat were added (10–300 nmol/ml or g) to fluids or tissues. Analysis of blank samples revealed no substrates that interfere with diquat elution. Excellent recovery (95–105%) was obtained. Diquat (120 μmol/kg, i.v.) was injected to rats and quantified in bile, blood and liver. Concentration of diquat was higher in blood and bile than liver. Therefore, this method is applicable for quantification of diquat in toxicological samples, and may be used to determine structurally similar compounds such as paraquat.  相似文献   

11.
Erythropoietin (EPO) is normally present in urine at a low concentration (about 1IU/L, i.e., about 10ng/L) for a total protein concentration of at least 50mg/L. A method to study the isoelectric profile of this hormone from 20-ml urine aliquots without previous purification was developed. This method involves isoelectric focusing of the retentate from ultrafiltered urine. Both the ultrafiltration and the isoelectric focusing required precautionary measures to prevent EPO degradation by the proteases that are present in urine. Because classical immunoblotting gave rise to an unspecific detection of various urinary proteins in the focused retentate, it was essential to use the "double-blotting" process developed to solve this problem. Sufficient sensitivity was achieved using amplified chemiluminiscent detection after the blotting membrane was treated with dithiotreitol. The patterns that were revealed from various urinary samples proved to be highly heterogeneous as they were composed of more than 10 isoforms in a pI range of 3.7-4.7. Clear transformation of the patterns was observed in the case of treatment by the recombinant hormone, suggesting that this method can be regarded an efficient tool for indicating recombinant EPO misuse in sports. It may also open new investigations in the field of physiologic or pathologic exploration.  相似文献   

12.
Visualization of amastigotes in lymph nodes, bone marrow, and other tissues samples remains the gold standard method for the diagnosis of visceral leishmaniasis (VL) in humans. This gold standard diagnostic method uses a technically challenging microscopy procedure that is often not accessible in many places in the world where VL is endemic. Here, we report the current systematic review and meta-analysis to evaluate whether urine is a reliable clinical sample for diagnosis of human VL. Data were extracted from ten available databases during the period from 2002 to 2017. Overall, 29 articles fulfilled the inclusion criteria and were used for data extraction in this systematic review. Most studies (72.4%) using urine specimens were reported from five countries: India 6 (20.7%), Iran 5 (17.2%), Bangladesh 4 (13.8%), Japan 3 (10.3%) and Spain 3 (10.3%), respectively. The most common diagnostic tests performed on urine were Katex (62.1%), ELISA (24.1%), and the rK39 (17.2%) assays. In meta-analysis the sensitivity and specificity of the three most commonly used diagnostic assays were rK39 (97%; CI: 91–99; 98%;76–100), ELISA (91%; 82–95; 99%; CI: 94–100), and Katex (83%; 73–90; 98%; 98–100), suggesting that the rK39 assay provided the highest sensitivity and the ELISA assay provided the highest specificity for diagnosis of VL from urine samples. Our findings suggest that urine is a valuable clinical sample for the diagnosis of human VL, particularly in areas where the gold standard test for VL is not available.  相似文献   

13.

Background

Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods.

Methodology/Principal Findings

We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template.

Conclusions/Significance

Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.  相似文献   

14.
A new method for hydrolyzing steroid conjugates (both sulfates and glucuronides conjugates) that is efficient, effective, and inexpensive is described. This method comprises incubation of the conjugates--after salting-out into ethyl acetate or elution from a C18 cartridge--with anhydrous methanolic hydrogen chloride (methanolysis) for 10 min. It has been successfully applied to our routine radioimmunoassay screening and GC/MS confirmation studies of steroids in prerace and postrace equine urine samples. Comparative GC/MS studies on entire (male horse) urine samples showed that methanolysis gave amounts of free steroids (estrone, estradiols, testosterone, estrenediols, nandrolone, androstanediols) at least as large as those obtained by solvolysis. Similar studies on urine samples from a gelding that had been administered nandrolone phenylpropionate showed that methanolysis gave larger amounts of free steroids (nandrolone, estranediols) than Helix pomatia enzymatic hydrolysis or solvolysis. Also, TLC studies on methanolysis of corticosteroid conjugates such as hydrocortisone 21-sulfate and hydrocortisone 21-phosphate showed that free corticosteroid was released in 5 min.  相似文献   

15.
The purpose of this study was to assess the natural exposure of male horses (Equus caballus) to the mycotoxin zearalenone (ZEA) by using the ELISA test and to evaluate the effects of in vitro exposure of sperm cells to mycotoxin-containing urine extracts on sperm chromatin structure stability. Because of their occurrence in urine samples, ZEA and its derivatives were tested by sperm chromatin structure assay (SCSA) at natural levels detected by ELISA. Thirty-eight urine extracts of Italian (n = 11) and northeastern European (n = 27) horses were tested on frozen-thawed spermatozoa to evaluate the toxic effect of mycotoxin on their chromatin structure by flow cytometry. Different parameters of the DNA fragmentation index (DFI), such as the mean (), the percentage (%-DFI), and the standard deviation (SD-DFI), were analyzed. Urine samples showed a mean level of 32.3 ng/mL ZEA with significantly higher concentrations in northeastern European samples than in Italian samples, probably in relation to climatic and feeding differences. The toxic effects of ZEA-containing urine samples on SCSA parameters were found at low ZEA concentrations and were mainly observed in Italian samples. By using mycotoxin standards, ZEA, α-zearalenol, and β-zearalenol proved to be more toxic compounds for sperm chromatin stability than other tested derivatives. A nongenomic mechanism of action can be hypothesized.  相似文献   

16.
Two stability challenges were encountered during development of an urine assay for a proliferator-activated receptor (PPAR) agonist, I (2-{[5,7-dipropyl-3-(trifluoromethyl)-1,2-benzisoxazol-6-yl]oxy}-2-methyl propionic acid), indicated for the treatment of Type II diabetes. First, the analyte was lost in urine samples due to adsorption on container surface which is a common problem during clinical sample handling. Secondly, the acylglucuronide metabolite (III), a major metabolite of I, displayed limited stability and effected the quantitation of parent drug due to the release of I through hydrolysis. Therefore, a clinical collection procedure was carefully established to stabilize I and its acylglucuronide metabolite, III, in human urine. The metabolite was not quantitated with this method. The urine samples are treated with bovine serum albumin (BSA) equal to 1.75% of the urine volume and formic acid equal to 1% of urine volume. Compound (I) and internal standard (II) were extracted from urine with 1 mL ethyl acetate using a fully automated liquid-liquid extraction in 96-well plate format. The analytes are separated by reverse phase high-performance liquid chromatography (HPLC) with tandem mass spectrometry in multiple-reaction-monitoring (MRM) mode used for detection. The urine method has a lower limit of quantitation (LLOQ) of 0.05 ng/mL with a linearity range of 0.05-20 ng/mL using 0.05 mL of urine. The method was validated and used to assay urine clinical samples.  相似文献   

17.
Prolidase deficiency (PD) is characterized by massive urinary excretion of imidodipeptides X-Pro and X-Hyp. We report the applicability of capillary zone electrophoresis to urinary imidodipeptide determination. The protocol is fast, simple, reliable, only small amounts of sample are required and there is minimal sample preparation. Electropherograms of urine samples from control subjects and four patients with prolidase deficiency were compared. The presence of imidodipeptides normally absent in urine was evident in patients' urine. Further analysis of urine samples enabled identification of excreted imidodipeptides and the pattern of excretion appeared to be heterogeneous for different patients. This method appears to be useful for identification of imidodipeptides in biological samples, as an efficient aid in diagnosis of PD, and as a method for providing more information about this disease.  相似文献   

18.
Nitric oxide is an ubiquitary cell signaling substance. Its enzymatic production rate by nitric oxide synthase is regulated by the concentrations of the substrate L-arginine and the competitive inhibitor asymmetric dimethylarginine (ADMA). A newly recognized elimination pathway for ADMA is the transamination to α-keto-δ-(N(G),N(G)-dimethylguanidino)valeric acid (DMGV) by the enzyme alanine-glyoxylate aminotransferase 2 (AGXT2). This pathway has been proven to be relevant for nitric oxide regulation, but up to now no method exists for the determination of DMGV in biological fluids. We have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of DMGV. D(6)-DMGV was used as internal standard. Samples were purified online by column switching, and separation was achieved on a porous graphitic carbon column. The calibration was linear over ranges of 10 to 200 nmol/L for plasma and 0.1 to 20 μmol/L for urine. The intra- and interday accuracies and precisions in plasma and urine were better than 10%. In plasma samples, DMGV was present in concentrations between 19.1 and 77.5 nmol/L. In urine samples, concentrations between 0.0114 and 1.03 μmol/mmol creatinine were found. This method can be used as a tool for the scientific investigation of the ADMA conversion to DMGV via the enzyme AGXT2.  相似文献   

19.

Background

The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration.

Methods

During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples.

Results

Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples.

Conclusions

The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.  相似文献   

20.
A rapid and efficient method for assaying both NPT II and GUS activities was developed. In this method, which is modified from that of McDonnell et al. (1987), and Jefferson (1987), no sample processing procedures such as grinding and centrifugation are necessary. Cut plant tissues (leaves) or intact calli or cells expressing the genes of interest are placed in wells of a microtiter plate containing reaction mixture, and after incubation the reaction mixture is directly used for both NPT II and GUS assays. For the NPT II assay, aliquots of the reaction mixture are blotted onto Whatman P81 paper through a manifold, and the product of the reaction is detected by autoradiography. For GUS activity, aliquots or the rest of the reaction mixture are observed for fluorescent emission under a hand-held UV light or read in a fluorimeter after adding stop buffer to the reaction mixture. This method is the simplest, cheapest, and quickest assays for NPT II and GUS reported to date, and is extremely efficient and suitable for assaying small amounts of samples (as little as 0.3 mg tissue), such as in transient expression assays, or for the quick screening of large numbers of samples, such as in studies of gene inheritance in transgenic plants. In our laboratory, it has been used successfully in assaying NPT II activities for transient and stable gene expression in transformed protoplasts, calli, and leaf tissues of various transgenic plants. It has also been used for detecting both NPT II and GUS activities in transgenic rice plants, in which more than 400 samples could be assayed per day per person.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号