首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The rapid detection of antimicrobial resistance is important in the effort to control the increase in resistant Mycobacterium tuberculosis (Mtb). Antimicrobial susceptibility testing (AST) of Mtb has traditionally been performed by the agar method of proportion or by macrobroth testing on an instrument such as the BACTEC (Becton Dickinson, Sparks, MD), VersaTREK (TREK Diagnostics, Cleveland, OH) or BacT/ALERT (bioMérieux, Hazelwood, MO). The agar proportion method, while considered the “gold” standard of AST, is labor intensive and requires calculation of resistance by performing colony counts on drug-containing agar as compared to drug-free agar. If there is ≥1% growth on the drug-containing medium as compared to drug-free medium, the organism is considered resistant to that drug. The macrobroth methods require instrumentation and test break point ("critical") drug concentrations for the first line drugs (isoniazid, ethambutol, rifampin, and pyrazinamide). The method described here is commercially available in a 96 well microtiter plate format [MYCOTB (TREK Diagnostics)] and contains increasing concentrations of 12 antimicrobials used for treatment of tuberculosis including both first (isoniazid, rifampin, ethambutol) and second line drugs (amikacin, cycloserine, ethionamide, kanamycin, moxifloxacin, ofloxacin, para-aminosalicylic acid, rifabutin, and streptomycin). Pyrazinamide, a first line drug, is not included in the microtiter plate due to its need for acidic test conditions. Advantages of the microtiter system include both ease of set up and faster turn around time (14 days) compared with traditional agar proportion (21 days). In addition, the plate can be set up from inoculum prepared using either broth or solid medium. Since the microtiter plate format is new and since Mtb presents unique safety challenges in the laboratory, this protocol will describe how to safely setup, incubate and read the microtiter plate.  相似文献   

2.
A rapid, enzyme-linked colorimetric assay, for the sequential determination of nanomole quantities of glucose and fructose in the same sample, has been developed for the measurement of fructosyl transferase activity in plant extracts. The assay extends the conventional dehydrogenase-linked assay for these sugars by utilizing the intermediary electron carrier, phenazine methosulfate, to couple NADP reduction to the production of a formazan dye from the tetrazolium salt, thiazolyl blue, in a form suitable for measurement using a microtiter plate reader. When the microtiter plate assay was used to measure the activities of yeast invertase and sucrose:sucrose fructosyl transferase from Lolium temulentum, results obtained were very similar to results obtained using the conventional procedure. The rapidity, small scale, and ease of execution of the method offers considerable advantages over the conventional hexose assay and is particularly suitable for screening of large numbers of small samples, exploiting both the speed of the microtiter plate reader and the facility of for microcomputer processing of data. The potential of this method for use with other enzyme systems and other metabolites is discussed.  相似文献   

3.
A high-throughput solid-phase platform for ligand-binding assays using microtiter plates (Scintiplates) has been developed using the scintillation proximity assay principle. The system has been developed using human alpha(2B)-adrenergic receptor (alpha(2B)-AR) expressed from Semliki Forest virus vectors in CHO cells. Alpha(2B)-AR bind natural (adrenaline and noradrenaline) and synthetic ligands with different affinities to mediate a variety of physiological and pharmacological responses. Antagonist radioligands were used for the binding experiments, and the values obtained for the binding constants with the Scintiplate system are in good agreement with those obtained by the traditional filter-binding assay system. The Scintiplate assay offers the advantages of a high-throughput format over the filter-binding assay and is amenable for screening many compounds rapidly for generation of leads.  相似文献   

4.
A method has been developed for the analysis of (14)CO(2) evolution from the mineralization of (14)C-labelled organic compounds in soil samples. The new method is less space demanding and substantially cuts down laborious manual work compared to the traditional incubation bottle method used. Furthermore, the use of scintillation cocktail is largely reduced with the new method. In the new method, (14)CO(2) is trapped in filter paper held in the lid of a 20 ml glass vial by surface tension. The trapping solution used is Ca(OH)(2), which fixates CO(2) in the filter paper and the analysis of trapped (14)CO(2) is done using the Cyclone trade mark Storage Phosphor system. The lids are placed in a 32 well holder and exposed to a phosphor screen prior to scanning in a Cyclone trade mark scanner. The new filter method has been tested and compared to results obtained using the traditional method. The results show good agreement but due to a smaller capacity for CO(2) with the filter method compared to the traditional method, the interval between sampling has to be shorter using the filter method when the CO(2) development is high. The detection limits for the filter method is higher compared to the traditional method. With the filter method, the level of radioactivity has to exceed 300 dpm before detection is possible, while the same limit for the traditional method is around 30 dpm. On the other hand, the gas trapping faster and the efficiency is higher with the filter method.  相似文献   

5.
6.
The principle of selective elution from a solid phase has been exploited to develop an assay for the determination of squalene biosynthesis in rat liver homogenates. Using either [1-14C]isopentenyl diphosphate as a precursor for squalene or [2-14C]farnesyl diphosphate as a direct substrate of squalene synthase, the production of radiolabeled squalene is determined after adsorption of assay mixtures onto silica gel thin-layer chromatography sheets and selective elution of the diphosphate precursors into a solution of sodium dodecyl sulfate at alkaline pH. The use of [2-14C]farnesyl diphosphate, and of an endogenous oxygen consumption system (ascorbate/ascorbate oxidase) to prevent further metabolism of squalene, allows the method to be applied as a dedicated assay for squalene synthase activity. The assay has been developed in microtiter plate format and may be deployed either in a quantitative, low-throughout mode or in a qualitative, high-through-put mode. The latter is suitable for screening to aid in the discovery of new inhibitors of squalene synthase.  相似文献   

7.
A microassay for proteases using succinylcasein as a substrate.   总被引:1,自引:0,他引:1  
A photometric assay for proteases has been developed. A chemically modified casein whose amino groups were succinylated was used as a substrate. After incubation with trypsin, chymotrypsin, thermolysin, and subtilisin, the extent of hydrolysis of the substrate was determined with trinitrobenzene sulfonate (TNBS). The whole procedure of the assay was performed in the microtiter plate wells and the increase in the absorbance resulting from the reaction between TNBS and newly formed amino groups in the substrate was able to be determined with a high sensitivity by a microtiter plate reader, enabling the simultaneous measurement of a number of samples. Application of this method to the measurement of proteolytic activity contained in the protein extract of Tapes philippinarum is demonstrated.  相似文献   

8.
Use of a 96-well microplate reader for measuring routine enzyme activities   总被引:2,自引:0,他引:2  
A method is described for the routine determination of the rate of colorimetric enzyme reactions using a 96-well microtiter plate reader commonly used in immunoassay. This approach is illustrated by monitoring esterase activity using three common products: release of thiol, release of ethanol, and release of p-nitrophenylate ion. Examples include monitorings of the rate of hydrolysis of acetylthiocholine iodide by eel acetylcholinesterase and the rate of hydrolysis of malathion and nonconventional esters such as O-methyl, O-ethyl, and O-isobutyl carbonates of p-nitrophenol by commercial porcine liver carboxylesterase. Data obtained from the plate reader were compared to those obtained, under similar conditions, in a conventional spectrophotometer. Absorbance measurements made in both machines on the same solution, as well as absorbance changes measured over time, were similar. The use of the 96-well plate format tremendously increased the number of enzyme assays carried out per person and the interface with a personal computer allowed rapid manipulation of the absorbance values to calculate the desired rate data. This approach should be generally applicable to many routine colorimetric assays in the research laboratory.  相似文献   

9.
A method has been developed to determine the relative or actual number of attached cells in microtiter plate wells without making direct cell counts. The procedure is based upon staining total cellular protein with Coomassie brilliant blue G-250, followed by measurement of absorbance at 630 nm in a spectrophotometer designed to read each well of a 96-well microtiter plate. No destaining of cells is required. A linear correlation exists (r = 0.970) between cell number and absorbance over a useful range. Intraplate well-to-well variation is acceptable (CV = 0.101). This method was used to measure the proliferative response of human vascular smooth muscle cells to human serum. It should be useful in other assays involving proliferation of attached cultured cells.  相似文献   

10.
Gal S  Cook JR  Howells L 《BioTechniques》2006,41(3):303-308
Many DNA binding proteins are known to regulate gene expression. When that binding is altered, a disease state can result. A common method for measuring DNA binding, namely electrophoretic mobility shift assay (EMSA) is often used but it is not amenable to rapid screening of many samples. As an alternative method, we have developed a DNA binding assay for the tumor suppressor protein p53 in a 96-well microtiter plate format using scintillation proximity assay (SPA) beads. We have shown this assay to be sensitive (as little as 0.5 ng p53 can be detected), quick (assay completed in as little as 15 min), and easily quantitated using a microtiter plate scintillation counter We also used the assay to analyze the kinetics of the DNA binding to p53. The specificity of this p53 DNA binding SPA was confirmed using competition by oligonucleotides either from the same gene or from mutated versions of this sequence. Thus, SPA is a good alternative to gel shift assays for DNA binding and may be useful for the analysis of multiple tumor cell samples or for high-throughput screens for compounds affecting DNA binding by proteins of interest.  相似文献   

11.
A sensitive fluorometric assay for the quantification of phosphite has been developed. The assay uses the enzymatic oxidation of phosphite to phosphate by a recombinant phosphite dehydrogenase with NAD+ as cosubstrate to produce the highly fluorescent reaction product resorufin. The optimized assay can be carried out in a 96-well microtiter plate format for high-throughput screening purposes and has a detection limit of 0.25 nmol phosphite. We used the method to quantify phosphite levels in plant tissue extracts and to determine phosphite dehydrogenase activity in transgenic plants. The assay is suitable for other biological or environmental samples. Because phosphite is a widely used fungicide to protect plants from pathogenic oomycetes, the assay provides a cost-effective and easy-to-use method to monitor the fate of phosphite following application.  相似文献   

12.
The yeast two-hybrid system is a powerful tool for identifying novel protein-protein interactions. In general, biochemical marker genes such as lacZ are exploited for indirect quantification of the interaction, and commonly involve the conduct of rather laborious beta-galactosidase assays. This paper describes a simple alternative method based on growth curve analysis of yeast cultures that is amenable to microtiter plate format, and therefore allows the quantification of large numbers of yeast two-hybrid combinations. The analyzed results of yeast cultures grown in microtiter plates were compared with those obtained from the classical beta-galactosidase assay. We conclude that the method presented here is reproducible, of equal or greater sensitivity than the beta-galactosidase assay, and can be further adapted for application to the conduct of large-scale, automated yeast two-hybrid experiments.  相似文献   

13.
The demand to increase throughput in HTS programs, without a concomitant addition to costs, has grown significantly during the past few years. One approach to handle this demand is assay miniaturization, which can provide greater throughput, as well as significant cost savings through reduced reagent costs. Currently, one of the major challenges facing assay miniaturization is the ability to detect the assay signal accurately and rapidly in miniaturized formats. Digital imaging is a detection method that can measure fluorescent or luminescent signals in these miniaturized formats. In this study, an imaging system capable of detecting the signal from a fluorescent protease assay in multiple plate formats was used to evaluate this detection method in an HTS environment. A direct comparison was made between the results obtained from the imaging system and a fluorescent plate reader by screening 8,800 compounds in a 96-well plate format. The imaging system generated similar changes in relative signal for each well in the screen, identified the same active compounds, and yielded similar IC(50) values as compared to the plate reader. When a standard protease inhibitor was evaluated in 96-, 384-, 864-, and 1536-well plates using imaging detection, similar IC(50) values were obtained. Furthermore, similar dose-response curves were generated for the compound in 96- and 384-well assay plates read in a plate reader. These results provide support for digital imaging as an accurate and rapid detection method for high-density microtiter plates.  相似文献   

14.
15.
An automated gridding procedure for the inoculation of yeast and bacterial clones in high-density arrays has been developed. A 96-pin inoculating tool compatible with the standard microtiter plate format and an eight-position tablet have been designed to fit the Biomek 1000 programmable robotic workstation (Beckman Instruments). The system is used to inoculate six copies of 80 x 120-mm filters representing a total of approximately 20,000 individual clones in approximately 3 h. High-density arrays of yeast artificial chromosome (YAC) and cosmid clones have been used for rapid large-scale hybridization screens of ordered libraries. In addition, an improved PCR library screening strategy has been developed using strips cut from the high-density arrays to prepare row and column DNA pools for PCR analysis. This strategy eliminates the final hybridization step and allows identification of a single clone by PCR in 2 days. The development of automated gridding technology will have a significant impact on the establishment of fully versatile screening of ordered library resources for genomic studies.  相似文献   

16.
Aerobic batch cultivations of Candida utilis were carried out in two micro bioreactors with a working volume of 100 μL operated in parallel. The dimensions of the micro bioreactors were similar as the wells in a 96‐well microtiter plate, to preserve compatibility with the current high‐throughput cultivation systems. Each micro bioreactor was equipped with an electrochemical sensor array for the online measurement of temperature, pH, dissolved oxygen, and viable biomass concentration. Furthermore, the CO2 production rate was obtained from the online measurement of cumulative CO2 production during the cultivation. The online data obtained by the sensor array and the CO2 production measurements appeared to be very reproducible for all batch cultivations performed and were highly comparable to measurement results obtained during a similar aerobic batch cultivation carried out in a conventional 4L bench‐scale bioreactor. Although the sensor chip certainly needs further improvement on some points, this work clearly shows the applicability of electrochemical sensor arrays for the monitoring of parallel micro‐scale fermentations, e.g. using the 96‐well microtiterplate format. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

17.
Radioimmunoassay (RIA) employing iodinated ligands represents a popular measurement method for small molecules due to its excellent sensitivity and specificity. Yet performing RIAs of large numbers of tubes remains a tedious laboratory chore due to the need to individually handle tubes multiple times. We here present a method in which conventional 125I-labeled RIA ([125I] RIA) is adapted to a microtiter plate format, termed mini-RIA. Tubes are handled in batch for centrifugation or during the separation of antibody-bound ligand from free ligand. A simple draining device for batch decantation of free ligand from 96 minitubes is used. Optimal conditions for the mini-RIA were established using two workup methods-double-antibody immunoprecipitation and direct polyethylene glycol precipitation. Use of the mini-RIA method was found to result in a considerable savings in assay times; in addition, the sensitivity of the mini-RIA was improved over conventional RIA. The mini-RIA is particularly useful for assay of large numbers of samples derived from chromatographic methods, since aliquots can be transferred directly from the fraction collector into the minitubes using multiple channel pipettors. Because the method is flexible with regard to assay workup, we predict that most conventional [125I] RIAs can be adapted to the mini-RIA format.  相似文献   

18.
A radiometric assay for tyrosine hydroxylase employing a coupled nonenzymatic decarboxylation of L-[14C]Dopa formed from L-[14C]tyrosine has been adapted for performance in a 96 microwell culture plate. The method uses an easily manufactured plate holder to compress blotting paper impregnated with methylbenzethonium hydroxide against the top rim of each well. This forms isolated, airtight compartments in which 14CO2 is evolved and quantitatively absorbed into the blotting paper. The method is sensitive enough to detect the production of less than 5 pmol of 14CO2. A major advantage of this system is that cells can be grown in tissue culture and subsequently assayed for tyrosine hydroxylase activity in the same well. The method is more facile than previously devised procedures, allowing for the simultaneous assay of up to 96 samples totally contained in a single, compact, portable unit.  相似文献   

19.
三种转基因酵母法筛选类雌激素活性物质方法的比较   总被引:1,自引:0,他引:1  
利用转基因酵母菌株,分别采用摇瓶法、96孔板法和单板法筛选类雌激素活性化学品,并对实验参数进行了优化。通过对工作光密度及β半乳糖苷酶反应时间的优化,使改进后的转基因酵母筛选法筛选一批样品的时间从原来需要的几天缩短为半天。并且在时间缩短的同时,仍保留原来检测的高灵敏度和准确性,也节省了大量的试验耗材,达到了能应用于环境样品中类雌激素活性物质的快速测定的目的。    相似文献   

20.
The E. coli cell method for nitrate measurement consists of two-steps: nitrate reduction by the E. coli cell usually under anaerobic conditions and subsequently nitrite measurement with the Griess reaction. It was found that the E. coli DSM 498k wildtype cell can reduce nitrate to nitrite under aerobic conditions. Therefore, the E. coli method for nitrate measurement was adapted to be performed under aerobic conditions in a microtiter plate. The adapted method is simpler than the original E. coli method and other nitrate methods such as those with inorganic reductants and with purified enzymes. Furthermore, it was found that for the Griess reaction the pH values of samples after addition of the Griess reagent A should be lower than 1.8 for a stable absorbance at 540 nm to be reached. It is important to add the two Griess reagents separately and to read the absorbance twice consecutively in a microtiter plate. The adapted E. coli method was successfully applied to measure the traces of nitrate in MRS and other medium components by measuring the standard curve of a dilution of each individual medium component. It was found that many organic medium components contain traces of nitrate, while none of them contain detectable nitrite. Among these, the extract of meat and yeast extract contain relatively high amounts of nitrate: 217 mg N/kg and 99 mg N/kg respectively. MRS broth contains nitrate from 0.3 to 0.6 mg N/l depending on the batch numbers of the product. The adapted E. coli can also be used for nitrate measurement in other matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号