首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An assay for measuring dihydroorotase activity was devised. Radiolabeled substrate and product were separated by high-performance liquid chromatography using a reverse-phase column with ion-pairing, and the radioactivity was quantitated by flow detection.  相似文献   

2.
Previous studies have measured histamine by derivatization with o-phthaldialdehyde (OPA) and mercaptoethanol (ME), followed by reversed-phase HPLC separation and electrochemical detection. The derivatization product, however, was very unstable. In the present study, inclusion of less polar solvents (e.g., acetonitrile or tetrahydrofuran) in the OPA/ME derivatization reaction produced an OPA/ME-histamine product that was stable for many hours. Changes of the HPLC mobile phase (increasing its ionic strength and pH and including triethylamine) dramatically improved the chromatography and reduced the histamine detection limit to <0.1 pmol. The modified assay was suitable for batchwise manual derivatization of histamine samples followed by their automated analysis by HPLC with an automatic injector.  相似文献   

3.
Catecholamine contents in the rat carotid body were determined using high performance liquid chromatography with electrochemical detection (LCEC). Dopamine was found to be the predominant catecholamine present, representing about 53% of all catecholamines in the carotid body. Norepinephrine accounted for about 36% and epinephrine for about 10% of total carotid body catecholamines.  相似文献   

4.
Several modifications of an HPLC—electrochemical assay method for plasma levels of norepinephrine (NE), epinephrine (EPI), dopamine (DA), dihydroxyphenylglycol (DHPG), dihydroxyphenylalanine (DOPA) and dihydroxyphenylacetic acid (DOPAC) that improve the accuracy and reliability of DHPG, DOPA, and DOPAC measurements are described. In batch alumina extractions, increasing the amount of alumina decreased analytical recoveries of DHPG, DOPA, and especially DOPAC, and increasing the strength of the eluting acid increased recoveries of these catechols, without affecting recoveries of the amines NE, EPI and DA. Refrigeration (4°C) until injection stabilized DOPAC in aqueous solution and therefore improved the reproducibility of plasma DOPAC measurements. Circulation of chilled water (15°C) around the column using a water jacket decreased variability in retention times of the catechols and thereby facilitated identification of peaks, while enhancing separation of DHPG from the solvent front. Use of 6-fluoro-DOPA and 6-fluoro-DOPAC as internal standards did not improve inter-assay reliability. We recommend that in assays of plasma catechols including DOPAC, small (5 mg), precisely measured amounts of alumina be used, with a relatively strong eluting solution (e.g. 0.04 M phosphoric acid—0.2 M acetic acid, 20:80, v/v), and that the samples be refrigerated until injection, with column temperature held constant at less than 20°C.  相似文献   

5.
6.
F M Siri  C D Kauer 《Life sciences》1985,37(20):1923-1931
Plasma epinephrine (EPI) and norepinephrine (NE) were measured in conscious, unrestrained rats at rest, and following exercise, cold stress and hemorrhage. Heart rate and mean arterial pressure were monitored at all points. Minor modifications of a standard, commercially available methodology achieved good chromatographic separation of both EPI and NE. Sensitivity was sufficient for all NE measurements and for EPI measurements in the stress conditions. Estimates of EPI by this procedure were somewhat higher than those in other reports. Absolute values of NE, as well as the selective, qualitative changes found in both EPI and NE under each stress condition, were consistent with those found in other studies which used the radioenzymatic method. Blood withdrawal of two 1.5 ml samples, 3 hours apart, had no detectable effect on EPI, NE, mean arterial pressure or heart rate in otherwise non-stressed rats.  相似文献   

7.
A sensitive method for assaying glutamine synthetase activity is described. This enzyme produces γ-glutamylhydroxamate in the presence of -glutamic acid and hydroxylamine as substrates. This amino acid hydroxamate was separated and quantified by high performance liquid chromatography on an ion-exchange resin column using post-column derivatization with o-phthalaldehyde for detection. As little as 50 pmol of γ-glutamylhydroxamate was detected in assays using cell-free extracts from fish retina, rat clonal C6 glioma cells, mouse clonal NIE 115 and N18TG2 neuroblastoma cells, whose specific activity measured was 1.0, 0.03, 0.01 and 0.01 μmol of γ-glutamylhydroxamate produced per 30 min per milligram protein, respectively.  相似文献   

8.
High performance liquid chromatography with coulometric electrochemical detection has been used to achieve simultaneous determination of norepinephrine, epinephrine, 5-hydroxytryptophan, normetanephrine, dopamine, metanephrine, 3,4-dihydroxyphenylacetic acid, N-acetyldopamine, tyramine, tryptophan, 5-hydroxyindoleacetic acid, 5-hydroxytryptamine, N-acetyl-5-hydroxytryptamine, homovanillic acid, tyrosine, p-octopamine, N-acetyl-p-octopamine, and p-synephrine. The procedure has been applied to study monoamine degradation in the insect brain and to demonstrate that N-acetylation rather than oxidative deamination is the primary route of monoamine catabolism in insects.  相似文献   

9.
10.
A highly sensitive isocratic capillary high-performance liquid chromatographic (HPLC) method with electrochemical detection (ED) for the simultaneous measurement of serotonin (5-hydroxytryptamine, 5-HT) and its metabolite 5-hydroxyindole-3-acetic acid (5-HIAA) in microdialysates has been developed using a 0.5 mm i.d. capillary column and a 11-nL detection cell. This method, validated on both pharmacological and analytical bases, can be performed using injection volumes as low as 1 microL. The limits of detection were 5.6 x 10(-11)mol/L and 3.0 x 10(-9)mol/L for 5-HT and 5-HIAA. Several applications of the present method are given on microdialysates from rodent brain and human spinal cord.  相似文献   

11.
A method for the detection of ascorbic acid using high-performance liquid chromatography with coulometric electrochemical detection and a technique for stabilization of the vitamin are described. Since less than 1 pmol of ascorbic acid can be detected, this assay provides significantly greater sensitivity than nearly all of the currently available procedures. Stabilization of 10 pmol or less of ascorbic acid at room temperature for up to 4 h and for several weeks at -70 degrees C facilitates storage of a large number of samples and measurement of ascorbic acid using an automated sampling device. This method was used to quantitate the amounts of ascorbic acid in human polymorphonuclear leukocytes and bovine adrenomedullary chromaffin granules. The calculated concentrations found for human neutrophils (1.35 mM) and bovine chromaffin granules (10.0 mM) are in agreement with previously published data. The assay is suitable for the determination of ascorbic acid in biological samples where only a small amount of tissue is available or very low amounts of ascorbic acid are found. This method is the first application of coulometric electrochemical detection to ascorbic acid HPLC analysis.  相似文献   

12.
We evaluated the use of HPLC multi-channel coulometric electrochemical detection (HPLC-ECD) for the routine measurement of phytochemicals by analyzing standards and urine samples. Compounds were separated chromatographically and electrochemically with high sensitivity (10 ng/ml of isoflavones in urine). HPLC-ECD will enable better investigation into the relationship between lifestyle and the effects of phytochemicals on humans.  相似文献   

13.
Mandelate racemase (EC 5.1.2.2) catalyzes the interconversion of the two stereoisomers of mandelic acid. A fixed-time assay for the quantification of mandelate racemase activity has been developed. The assay involves enzymatic conversion of R-mandelate to S-mandelate (or the reverse reaction) followed by separation and detection of the substrate and product using isocratic reversed-phase high-performance liquid chromatography on a Sumichiral OA-6100 column and absorbance detection. This method offers an economical and efficient alternative to the existing circular dichroism-based and coupled assays.  相似文献   

14.
A method using reversed-phase high-performance liquid chromatography with electrochemical detection for the analysis of vancomycin in human plasma was developed. Chromatographic conditions included an octadecyl column, a mobile phase of acetonitrile–sodium phosphate buffer (pH 7) (12:88), a total run time of 12 min, and coulometric electrochemical detection at +700 mV. Linear detector response was found in the range 5–100 μg ml−1 after a 1:80 dilution or from 0.5 to 50 μg ml−1 after a 1:20 dilution of the samples. In both cases the correlation coefficient (r) of the calibration curve standard was better than 0.995. Vancomycin determination was based on a denaturation of plasma proteins with methanol, then a dilution with mobile phase was performed. Recovery of vancomycin from plasma was 103.1±3.9%, and no interference from commonly used drugs or endogenous compounds was observed. A significant correlation was shown with the EMIT assay (r=0.92, P<0.001) using clinical samples from children. This HPLC technique is simple, sensitive, rapid, precise, selective and requires only 100 μl of plasma for completion.  相似文献   

15.
16.
4-Hydroxyanisole (p-methoxyphenol) has been used in the treatment of malignant melanomas. A simple, sensitive, and specific, method for its determination by liquid chromatography with electrochemical detection (LCEC) is described. Vanillin (4-hydroxy-3-methoxybenzaldehyde) was used as an internal standard.  相似文献   

17.
Low-molecular-mass thiols, such as glutathione (GSH), and their associated disulfides are ubiquitous in nature, and based upon the many known functions of these compounds, their identification and accurate measurement is essential. Our objectives were to develop a simple method for the simultaneous measurement of thiols and disulfides in biological samples using HPLC with dual electrochemical detection (HPLC-DED). Particular emphasis was placed on the applicability to a wide variety of important GSH-related thiols and disulfides, including γ-Glu-Cys, Cys-Gly, their disulfides, and the mixed disulfide of glutathione and cysteine (CSSG), validation on different types of biological samples, maintenance of chromatographic resolution and reproducibility with routine and extended use, and enhancement of assay sensitivity. To this end, optimal HPLC conditions including mobile phase, column, and electrode polishing procedures were established and the method was applied to, and validated on a variety of biological samples. This improved methodology should prove to be a useful tool in studies on the metabolism of GSH and other thiols and disulfides and their role in cellular homeostasis and disease processes.  相似文献   

18.
Liquid chromatography with electrochemical detection (LCEC) has been shown to have unique advantages for the determination of many substances of neurochemical interest. The technique is rapid, sensitive, and relatively inexpensive. In addition, it avoids the need for radiolabelled substances, the formation of volatile derivatives, or reactions which generate fluorescent products. LCEC is widely used for the measurement of the catecholamines and their metabolites and has recently gained acceptance for determination of the neurochemically important tryptophan metabolites. The method is also capable of assessing the activity of a number of neurologically important enzymes. The review which follows is intended to provide a brief overview of the LCEC technique and a guide to recent literature exemplifying its neurochemical applications.  相似文献   

19.
20.
Cysteamine is currently used to treat children with the inherited disorder nephropathic cystinosis. A method for the quantitative determination of this aminothiol in human plasma is presented. Whole plasma was reduced with sodium borohydride to convert disulfides to thiols. Cysteamine was then separated by high-performance liquid chromatography and detected electrochemically. The recovery of standard cysteamine added to plasma was 96.6 +/- 1.9%. In a patient with cystinosis, an oral dose of cysteamine was absorbed rapidly, with plasma cysteamine reaching a maximum of 56 microM 1 h after the dose. By 1.8 h the plasma cysteamine concentration had decreased to one-half the maximum value.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号