首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Modern ultrasound-guided prostate brachytherapy is rapidly changing the way localized prostate cancer is managed. With routine use of prostate-specific antigen screening, prostate cancer is being diagnosed in younger men, who are understandably concerned about the morbidity of radical treatments that may significantly decrease their quality of life. Numerous studies of prostate brachytherapy have shown the excellent disease control rates achieved while maintaining low levels of urinary and erectile difficulties. This report examines a modern implant method of brachytherapy; describes patient selection for brachytherapy, alone and in combination with external beam therapy; and presents results from a series of men followed for 12 years.  相似文献   

2.
PurposePost-implant CT-scanning is an essential part of permanent prostate brachytherapy. However, the evaluation of post-implant CT dosimetry is not straightforward due to the edema that can modify the dose to the prostate and to the organs at risk. The aim of this study is to evaluate the impact of the timing of the post-implant CT-scan on the dosimetric results and to verify if the Day 0 scan findings can predict Day 50 scanning.Methods136 consecutive patients who received monotherapy with I-125 implants were selected for this study. Two sets of 8 dosimetric quality parameters corresponding to 2 different CT-scans (Day 0 and Day 50) were calculated and compared. The dosimetric parameters included are the percentage volume of the post-implant prostate receiving 80%, 100% and 150% of the prescribed dose, the doses covering 80% and 90% of the prostate volume and the Dose Homogeneity Index. The values of the dose covering 1 cm3 of the rectum and urethra were assessed.ResultsAll the dosimetric parameters of the Day 50 were higher than those of the Day 0 scan. Linear functions were obtained that calculate D90 and V100 values at Day 50 based on the Day 0 findings. Rectal and urethral parameters tended to be underestimated on Day 0 CT-scan relative to Day 50 based dosimetry.ConclusionsPredicting the Day 50 dosimetry from the Day 0 scan could be a possible alternative to a Day 50 scan only in specific situations, but with a degree of uncertainty in the predicted values.  相似文献   

3.
4.
Radiation therapy is one option for patients with localized prostate cancer. Despite advances in delivering radiation to the prostate gland with therapies such as brachytherapy and/or external beam radiation therapy, urologists will be faced with managing patients with rising prostate-specific antigen values and with positive biopsy results secondary to radiation-recurrent prostate cancer. If the cancer is detected early, salvage therapy can be initiated. Since salvage prostatectomy is associated with significant morbidity, patients are often left with the option of either watchful waiting or temporary palliation with hormone deprivation therapy, with its attendant toxicity. The introduction of third-generation cryotechnology using 17-gauge CryoNeedlestrade mark (Oncura, Inc., Plymouth Meeting, PA) and the recent modifications in the technique of salvage cryosurgery have enabled cryosurgeons to eradicate these tumors safely and with significantly decreased morbidity. Selection and management of patients, as well as the contemporary results of salvage cryosurgery, are discussed in this article.  相似文献   

5.
Prostate cancer is one of the most common malignancies among males. 125I brachytherapy is a current, effective, comparatively safe, and easy-to-reproduce treatment. The Russian X-ray Radiology Research Center has implanted 125I microsources in patients with localized and locally advanced prostate cancer since 2003; 689 125I implantations were performed in the past year. Tumor-specific survival after brachytherapy did not differ greatly from that following radical prostatectomy. Thus, brachytherapy is a current high-tech treatment for prostate cancer. This therapy shows fewer adverse postradiation effects than radiation teletherapy.  相似文献   

6.
Brachytherapy by permanent implants is an alternative to radical prostatectomy or external beam radiotherapy for good prognosis localized prostate cancer. The advantages of this treatment are effective and precise irradiation, limited to the prostate gland with moderate and transient morbidity. Erectile dysfunction, frequent erection after surgery and external beam radiotherapy, is observed in 6% to 61% of cases in the literature after brachytherapy. This wide range is related to differences in terms of follow-up, definition of sexual disorders, and the measuring instruments used. These erectile disorders occur between 9 and 17 months after treatment and appear to be related to vascular radiation lesions of the erectile bodies close to the prostatic apex (urethral bulb and base of the corpora cavernosa). However, the majority of erectile disorders respond favourably to oral treatments such as yohimbine or sildenafil. Among the various curative treatment options for localized prostate cancer, permanent implant brachytherapy is the treatment ensuring the best preservation of erectile function.  相似文献   

7.
8.
Despite dramatic and recently accelerated advances in the reduction of morbidity linked to radical prostatectomies, significant short- and long-term morbidity is still associated with this surgical procedure. Currently both surgical and nonsurgical minimally invasive options are available for men with clinically localized prostate cancer, including laparoscopic and robotic radical prostatectomy, brachytherapy, and cryosurgical ablation of the prostate, with others, such as high intensity focused ultrasound, under investigation. In continued efforts to improve patient outcomes and to tailor treatment options to individual patient circumstances, nomograms have been developed and are increasingly being used by physicians and patients, alike, to guide therapeutic choices at each stage of disease. This tool predicts the possibility of successful treatment for the patient based on factors such as prostate-specific antigen levels, clinical stage of disease, and biopsy results. The current and future development, design, availability, and use of nomograms is described along with the historic and newer minimally invasive treatment options for prostate cancer.  相似文献   

9.
One of the highlights of the 16th International Prostate Cancer Update was a session on treatment- and disease-related complications of prostate disease. It began with presentation of a challenging case of rising prostate-specific antigen levels after radical prostatectomy, followed by an overview of the use of zoledronic acid in prostate cancer, a review of side effects of complementary medicines, an overview of complications of cryotherapy, an assessment of complications of brachytherapy and external beam radiation therapy, and a comparison of laparoscopy versus open prostatectomy.  相似文献   

10.
Cryosurgical ablation of the prostate (CSAP) is indicated for patients with high-stage and high-grade tumors, patients with recurrent/persistent carcinoma of the prostate after external radiation therapy or brachytherapy, and others. At Allegheny General Hospital, CSAP is performed as follows: the patient is prepped in an exaggerated lithotomy position; a volumetric study of the gland is obtained with transrectal ultrasound; 5 to 15 cryoneedles are placed (in three to five horizontal rows) through a 17-gauge, stepper-mounted template; a cystoscopy is performed; and a urethral warming catheter is introduced. The rows of cryoneedles are then activated from anterior to posterior, and generally two freeze-thaw cycles are used. In longer glands, a pullback of the cryoneedles might be needed to completely cover the apical portion of the gland. The skills required for CSAP are identical to those required for brachytherapy needle placement, thus the training required for physicians already proficient in brachytherapy is minimized.  相似文献   

11.
Introduction: The effect of radiation therapy on acute myeloid leukemia incidence among prostate cancer patients has not been sufficiently elucidated despite evidence that acute myeloid leukemia is a consequence of therapeutic radiation in other primary malignancies. Therefore, we investigated the effect of definitive therapy with radiation therapy (external beam radiation therapy [EBRT] or brachytherapy) on acute myeloid leukemia incidence in a population-based cohort of patients with localized or locally advanced prostate cancer. Methods: We utilized the Surveillance, Epidemiology, and End Results database to identify a cohort of men (n = 168,612) with newly diagnosed prostate adenocarcinoma between January 1988 and December 2003. Cox proportional hazard regression was used to estimate the hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) of acute myeloid leukemia incidence following definitive therapy with EBRT alone, brachytherapy alone, or surgery alone compared to no definitive therapy (i.e. no EBRT, brachytherapy, or surgery). Results: The cohort yielded 184 acute myeloid leukemia cases during 1,064,820 person-years of follow-up after prostate adenocarcinoma diagnosis. Patients treated with EBRT had a higher adjusted relative risk of developing acute myeloid leukemia than patients treated with brachytherapy or surgery when each therapy group was compared to patients who were not treated with definitive therapy (EBRT: HR = 2.05, 95% CI 1.29, 3.26; brachytherapy: HR = 1.22, 95% CI 0.46, 3.22; surgery: HR = 1.24, 95% CI 0.77, 1.98). Conclusions: Our findings suggest that acute myeloid leukemia incidence is a greater concern for patients treated with EBRT than brachytherapy for localized or locally advanced prostate adenocarcinoma.  相似文献   

12.
PurposeRetrospective, single-institution analysis of clinical outcomes and treatment-related toxicity in patients treated with salvage I-125 low-dose rate (LDR) brachytherapy (BT) for locally-recurrent prostate cancer after radiotherapy.Materials and methodsBetween 2008 and 2018, 30 patients with biopsy-confirmed prostate cancer recurrence underwent salvage treatment with I-125 LDR-BT. Of these 30 patients, 14 were previously treated with primary external beam radiotherapy (EBRT; median dose, 73 Gy) and 16 with primary I-125 LDR-BT (145 Gy and 160 Gy in 14 and 2 cases, respectively). At seed implantation, the mean age was 75.8 years, with a median Gleason score of 7 and pre-salvage PSA of <10 ng/mL. Six patients received androgen deprivation therapy for six months after relapse diagnosis. The prescribed salvage I-125 BT dose to the gland was 120−130 Gy, with dose restrictions of Dmax <135% (urethra) and <100% (rectum). Toxicity was evaluated according to the CTCAE scale (v4.0).ResultsAt a median follow-up of 45 months, the biochemical recurrence-free survival rates at 1, 3 and 5 years were 86.7%, 56.7% and 53.3%, respectively. Overall survival at 5 years was 87%. On the multivariate analysis, two variables were significant predictors of recurrence: PSA at relapse and nadir PSA post-salvage. Grade 3 genitourinary toxicity was observed in 5 patients (radiation-induced cystitis in 3 cases and urethral stenosis in 2) and G3 gastrointestinal toxicity in 3 patients (rectal bleeding).ConclusionSalvage therapy with I-125 brachytherapy is a safe and effective treatment option for locally-recurrent prostate cancer in previously-irradiated patients. High pre-salvage PSA and post-salvage nadir PSA values were significantly associated with a worse disease control after salvage I-125 LDR-BT. In well-selected patients, I-125 LDR-BT is comparable to other salvage therapies in terms of disease control and toxicity. However, more research is needed to determine the optimal management of locally-recurrent prostate cancer.  相似文献   

13.
In this study version 5 of the MCNP photon transport simulation was used to calculate the dosimetric parameters for new palladium brachytherapy source design following AAPM Task Group No. 43U1 report. The internal source components include four resin beads of 0.6 mm diameters with 103Pd uniformly absorbed inside and one cylindrical copper marker with 1.5 mm length. The resin beads and marker are then encapsulated within 0.8 mm in diameter and 4.5 mm long cylindrical capsule of titanium. The dose rate constant, Λ, line and point-source radial dose function, gL(r) and gP(r), and the anisotropy function, F(r,θ) of the IR01-103Pd seed have been calculated at distances from 0.25 to 5 cm. All the results are in good agreement with previously published thermoluminescence-dosimeter measured values [3] for the source. The dosimetric parameters calculated in this work showed that in dosimetry point of view, the IR01-103Pd seed is suitable for use in brachytherapy of prostate cancer.  相似文献   

14.
The aim of this paper is to evaluate clinically relevant quality assurance (QA) tests for RapidArc prostate patients. 26 plans were verified by the COMPASS system that provides an independent angle response and a reconstruction of dose distribution in patient CT model. Plan data were imported from treatment planning system via DICOM. The fluencies, measured by a 2D detector, were used by COMPASS to forward calculate dose in CT patients and reconstruct dose-volume-histogram (DVH). The gamma analysis was performed, using both the criteria 3%-3-mm and 2%-2 mm, for the whole grid patient and the per-structure volume. A DVH-based analysis was accomplished for target and organs-at-risk (OAR). The correlation between gamma passing rates and DVH discrepancies was performed using Pearson's test. Sensitivity, specificity and accuracy of whole and per-structure gamma method were calculated.No significant DVH deviation was observed for target and OAR. Weak correlation between gamma passing rates and dosimetric deviations was observed, all significant r-values were negative. The whole gamma method shows lack of sensitivity to detect dosimetric deviations >5%. Instead, a better balance between sensitivity and specificity was obtained employing per structure gamma both with 3%-3 mm and 2%-2 mm criteria.Because of the poor correlation between DVH goals and gamma passing rates, we encourage the DVH-based gamma passing rates, when it is possible. At least, a gamma method specific for structure was strongly suggested.  相似文献   

15.
Quality ultrasound images are an essential part of prostate brachytherapy procedure. The authors have previously reported that tissue harmonic ultrasound images (THI) are superior to brightness (B) mode for the prostate. The objective of the current study was to compare both imaging modes for visualization of the prostatic urethra and rectum.B and THI mode transrectal ultrasound images were acquired for ten patients. The prostatic urethra and rectal wall were contoured by a radiation oncologist (RO) and five observers on randomly presented images. The contours on one patient were repeated four additional times by four observers. All the images were qualitatively scored using a five-level Likert scale.The values of the Pearson product-moment correlation coefficients showed that the observers were in close agreement with the RO. Two sample paired student t-test showed that the rectum volumes with THI were significantly smaller than B-mode, but no significant difference for urethra. Two-factor analysis of variances showed significant observer variability in defining the rectum and urethra in both imaging modes. Observer consistency of the rectum volumes, estimated by standard deviations as percentages of means was significantly improved for THI. The Likert scale based qualitative assessment supported quantitative observations.The significant improvement in image quality of the prostate (reported previously) and rectum with THI may offer better-quality treatment plans for prostate brachytherapy and potential improvement in local control.  相似文献   

16.
The objective of this study was to determine whether an association exists between certain single nucleotide polymorphisms (SNPs), which have previously been linked with adverse normal tissue effects resulting from radiotherapy, and the development of radiation injury resulting from radiotherapy for prostate cancer. A total of 135 consecutive patients with clinically localized prostate cancer and a minimum of 1 year of follow-up who had been treated with radiation therapy, either brachytherapy alone or in combination with external-beam radiotherapy, with or without hormone therapy, were genotyped for SNPs in SOD2, XRCC1 and XRCC3. Three common late tissue toxicities were investigated: late rectal bleeding, urinary morbidity, and erectile dysfunction. Patients with the XRCC1 rs25489 G/A (Arg280His) genotype were more likely to develop erectile dysfunction after irradiation than patients who had the G/G genotype (67% compared to 24%; P=0.048). In addition, patients who had the SOD2 rs4880 T/C (Val16Ala) genotype exhibited a significant increase in grade 2 late rectal bleeding compared to patients who had either the C/C or T/T genotype for this SNP (8% compared to 0%; P=0.02). Finally, patients with the combination of the SOD2 rs4880 C/T genotype and XRCC3 rs861539 T/C (Thr241Met) genotype experienced a significant increase in grade 2 late rectal bleeding compared to patients without this particular genotypic arrangement (14% compared to 1%; P=0.002). These results suggest that SNPs in the SOD2, XRCC1 and XRCC3 genes are associated with the development of late radiation injury in patients treated with radiation therapy for prostate adenocarcinoma.  相似文献   

17.

Aim

This study evaluates the acute toxicity outcome in patients treated with RapidArc for localized prostate cancer.

Background

Modern technologies allow the delivery of high doses to the prostate while lowering the dose to the neighbouring organs at risk. Whether this dosimetric advantage translates into clinical benefit is not well known.

Materials and methods

Between December 2009 and May 2012, 45 patients with primary prostate adenocarcinoma were treated using RapidArc. All patients received 1.8 Gy per fraction, the median dose to the prostate gland, seminal vesicles, pelvic lymph nodes and surgical bed was 80 Gy (range, 77.4–81 Gy), 50.4 Gy, 50.4 Gy and 77.4 Gy (range, 75.6–79.2 Gy), respectively.

Results

The time between the last session and the last treatment follow up was a median of 10 months (range, 3–24 months). The incidence of grade 3 acute gastrointestinal (GI) and genitourinary (GU) toxicity was 2.2% and 15.5%, respectively. Grade 2 acute GI and GU toxicity occurred in 30% and 27% of patients, respectively. No grade 4 acute GI and GU toxicity were observed. Older patients (>median) or patients with V60 higher than 35% had significantly higher rates of grade ≥2 acute GI toxicity compared with the younger ones.

Conclusions

RapidArc in the treatment of localized prostate cancer is tolerated well with no Grade >3 GI and GU toxicities. Older patients or patients with higher V60 had significantly higher rates of grade ≥2 acute GI toxicity. Further research is necessary to assess definitive late toxicity and tumour control outcome.  相似文献   

18.
PurposeDosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage.Materials and methodsA low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator’s density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator.ResultsMeasured printing accuracy was within 0.5 mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3 mm distance-to-agreement criteria and 10% dose threshold.ConclusionLow-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application.  相似文献   

19.
The recommended radio-therapeutic treatment for cervix cancer consists of a first phase of external beam radiotherapy (EBRT) plus a second phase of brachytherapy (BT), the combined treatment being delivered within 8 weeks.In order to assess a comprehensive dosimetry of the whole treatment, it is necessary to take into account that these two phases are characterized by different spatial and temporal dosimetric distributions, which complicates the task of the summation of the two contributions, EBRT and BT. Radiobiology allows to tackle this issue pragmatically by means of the LQ model and, in fact, this is the usual tool currently in use for this matter.In this work, we describe the rationale behind the summation of the dosimetric contributions of the two phases of the treatment, EBRT and BT, for cervix cancer, as carried out with the LQ model.Besides, we address, from a radiobiological point of view, several important considerations regarding the use of the LQ model for this task. One of them is the analysis of the effect of the overall treatment time in the result of the global treatment. Another important question considered is related to the fact that the capacity of LQ to predict the treatment outcomes is deteriorated when the dose per fraction of the radiotherapic scheme exceeds 6–10 Gy, which is a typical brachytherapy fractionation. Finally, we analyze the influence of the uncertainty and the variability of the main parameters utilized in the LQ model formulation in the assessment of the global dosimetry.  相似文献   

20.
Radioresistant or recurrent prostate cancer represents a serious health risk for approximately 20%-30% of patients treated with primary radiation therapy for clinically localized prostate cancer. The majority of patients exhibit large volume and poorly differentiated disease at the time of diagnosis, which limits the ability of salvage therapy to eradicate the cancer. Early detection with serum PSA monitoring and prostate needle biopsy following primary radiation therapy may identify residual adenocarcinoma at an earlier stage and increase the likelihood of successful salvage therapy. Radical prostatectomy, prostate cryoablation, and brachytherapy comprise the options for salvage treatment available for radiorecurrent prostate cancer. The goal of disease eradication must be balanced against the potential for serious treatment-related side effects. As a result, many patients receive noncurative therapy with androgen ablation despite the real risk of disease progression and mortality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏