1.
A selective and sensitive method for analysis of perfluorooctanoic acid (PFOA) in human serum and plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. A simple, automated sample preparation procedure, involving extraction of the target analyte with acetonitrile on protein precipitation media in a 96-well plate format was developed, allowing efficient handling of large numbers of samples. The proposed method uses the calibration standards prepared in a surrogate matrix (rabbit serum or plasma) and (13)C-labeled PFOA as the internal standard to account for matrix effects, instrument drift, and extraction efficiency. Human serum and plasma could not be used for matrix matching of calibration standards as endogenous levels of PFOA observed in the control human serum and plasma significantly exceeded the targeted lower limit of quantitation (LLOQ) of the method. Precision and accuracy of the method were demonstrated by analysis of rabbit serum and plasma control samples fortified at 0.5, 5, and 40 ng/mL PFOA and human serum and plasma fortified at 1.0, 5.0, 40 ng/mL PFOA. The LLOQ of 0.5 ng/mL PFOA was experimentally demonstrated for rabbit and human serum and plasma. Within-day precision and accuracy, short-term stability, freeze-thaw stability, equivalence of response between PFOA and APFO (the ammonium salt of PFOA), and dilution of concentrated samples were also investigated. The results of the validation experiments comply with the precision and accuracy limits defined by the FDA guidance document: "Guidance for Industry, Bioanalytical Method Validation", May 2001.  相似文献   

2.
Voriconazole is a novel broad-spectrum antifungal agent. We developed an on-line LC-LC-MS-MS method for fully automated and direct analysis of voriconazole in raw human serum. After injection of human serum size-selective sample fractionation and analyte extraction was achieved using an extraction column (25 mm x 4 mm) packed with a restricted access material (RAM, LiChrospher ADS C(8), 25 microm). On-line transfer of voriconazole from the extraction column was followed by chromatography separation on a C(18) column. Detection was done by ESI-MS-MS. The total analysis time was 13 min, managed by parallel extraction and chromatographic separation. This LC-MS assay was fully validated. The lower limit of quantification was 0.05 microg/ml. The automated inline extraction of voriconazole described here eliminates the need for difficult and time-consuming sample pre-treatment. Other advantages of the new method are that only a small quantity (5 microl) of serum is needed and that the method is very specific.  相似文献   

3.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

4.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

5.
A simple, rapid, sensitive, and specific liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the quantification of amitraz and its metabolite in human serum. Both the compounds were extracted using monolithic silica spin columns with acetonitrile. The chromatographic separation was performed on a reverse-phase C(18) column with a mobile phase of 10 mM ammonium formate-acetonitrile. The protonated analyte was quantitated in positive ionization by mass spectrometry. The method was validated over the concentration range of 25-1000 ng/ml for amitraz and its metabolite in human serum. For both compounds, the limit of detection was 5 ng/ml. The method was applied to serum samples taken from an attempted suicide patient, and only small volumes of serum were required for the simultaneous determination of these compounds.  相似文献   

6.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

7.
A rapid, sensitive, specific, accurate, and reproducible automated liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the quantitative determination of 1'-(2-amino-3-methylbenzoyl)-4-[[[(3-chlorophenyl)sulfonyl]phenyl]methyl]-1,4'-bipiperidine hydrochloride (SCH 211803) in plasma has been developed. The method was validated in rat and monkey plasma over the concentration range of 0.5-250 ng/ml using 2H(4)-SCH 211803 as the internal standard (IS). Automated 96-well plate protein precipitation (PP) with acetonitrile (ACN) was used for sample processing. The method employed a Betasil C18 column with a fast gradient for the separation of analyte and internal standard from the plasma matrix and a triple quadrupole mass spectrometer operated in positive ion multiple reaction monitoring (MRM) mode for detection. The method was used for the determination of SCH 211803 plasma concentrations to support pre-clinical studies.  相似文献   

8.
Singh RJ 《Steroids》2008,73(13):1339-1344
Testosterone, the major androgenic hormone in humans, is commonly measured to aid in the diagnosis of clinical conditions related to its excess or deficiency. In addition, testosterone measurements are used to monitor testosterone replacement-, or antiandrogen therapy. Most commonly, automated direct immunoassays have been used to measure testosterone in human serum. Their advantage compared with other methodologies, lies in high- and rapid sample throughput with minimal human intervention. However, many automated testosterone immunoassays suffer from poor accuracy at the low concentration levels (<50ng/dL) seen in women and children, or in men undergoing anti-androgen therapy. Our objective was to develop a LC-MS/MS method which measures testosterone in human serum while fulfilling the following criteria: Rapid pre-analytical sample processing with minimal manual sample manipulation; Minimize sample volume requirements; Accurate, precise and unambiguous measurement; Functional sensitivity of 5-10ng/dL; Sample throughput of at least 30 samples per hour. Our validation criteria for precision, accuracy, and linearity was to have accuracy and linearity within mean limits of +/-10%; Intra and inter-assay precision of <15% throughout the reporting range. We also wanted to compare our results to a previously validated LC-MS/MS assay which utilized a manual liquid-liquid extraction and to an automated commercial immunoassay (Bayer ACS:180). We describe here a sensitive and rapid testosterone assay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing on-line sample extraction and multiplexing.  相似文献   

9.
A robust and validated liquid-liquid extraction LC-MS/MS method was developed for population pharmacokinetic analysis and therapeutic drug monitoring of risperidone and the enantiomers of its major active metabolite (+)-and (-)9-hydroxyrisperidone in pediatric patients. The method was rapid, sensitive and used a low sample amount (200 microL), which is very desirable for the pediatric population. The assay was validated from 0.2 to 50 ng/mL in plasma for all analytes. LLOQ for all analytes was 0.2 ng/mL. The extracts were analyzed by normal phase LC-MS/MS. The sample run time was 8 min. Intra- and interday precision for all analytes was < or =6%; method accuracy was between 89 and 99%. Additional experiments were performed to analyze matrix effects and identify a proper internal standard for each analyte. The validated method was used to study risperidone and its enantiomer metabolites in plasma as part of a population pharmacokinetic study in pediatric patients with pervasive developmental disorder (PDD).  相似文献   

10.
A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.  相似文献   

11.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of the new anticancer agent picropodophyllin (AXL1717) and its isomer podophyllotoxin levels in human serum has been developed. Monitoring of hexylamine adducts rather than proton adducts was used to optimize sensitivity. The chromatography system was an Acquity BEH C18, 2.1 mm × 50 mm 1.7 μm column with gradient elution (mobile phase A: 2.5 mM hexylamine and 5 mM formic acid in Milli-Q water and mobile phase B: methanol). The retention times were 1.4 min for picropodophyllin, 1.5 min for podophyllotoxin and 1.9 min for internal standard deoxypodophyllotoxin. The isomers were base-line separated. The analytes were detected after electrospray ionization in positive mode with selected reaction monitoring (SRM) with ion transitions m/z 516→102 for picropodophyllin and podophyllotoxin and m/z 500→102 for internal standard. The sample preparation was protein precipitation with acetonitrile (1:3) containing internal standard followed by dilution of the supernatant with mobile phase A (1:1). The limit of quantification (LOQ) was 0.01 μmol/L for picropodophyllin and podophyllotoxin. The limit of detection (LOD) at 3 times the signal to noise (S/N) was estimated below 0.001 μmol/L for picropodophyllin and podophyllotoxin. The quantification range of the method was between 0.01 μmol/L and 5 μmol/L for both isomers. The accuracy was within ±15% of the theoretical value for both picropodophyllin and podophyllotoxin and inter-assay precision did not exceed ±15%, except for the 0.016 μmol/L level of podophyllotoxin, which was 18%. The selectivity of the method was verified by analysis of two different product ions for each analyte and by analysis for interference of seven different batches of blank human serum. The combined recovery and matrix effects were about 83% for picropodophyllin and podophyllotoxin. The new LC-MS/MS method showed sufficient sensitivity and selectivity for determination of picropodophyllin and its isomer podophyllotoxin levels in human serum from subjects receiving therapeutic doses of AXL1717.  相似文献   

12.
A sensitive and selective method is described for the determination of artemether and its active dihydroartemisinin metabolite in human plasma using artemisinin as internal standard. The method consists of a liquid-liquid extraction with subsequent evaporation of the supernatant to dryness followed by the analysis of the reconstituted sample by liquid chromatography-mass spectrometry (LC-MS) in single ion monitoring mode using atmospheric pressure chemical ionization (APCI) as an interface. Chromatography was performed on a C(18) reversed-phase column using acetonitrile-glacial acetic acid 0.1% (66:34) as a mobile phase. The method was fully validated over a concentration range of 5-200 ng/ml using 0.5 ml of human plasma per assay. Stability assessment was also included. The method was applied to the quantification of artemether and its metabolite in human plasma of healthy volunteers participating in pharmacokinetic drug-drug interaction studies.  相似文献   

13.
In this review we describe procedures, performance characteristics and limitations of methods available for the measurement of 25-hydroxyvitamin (25OHD) since the year 2000. The two main types of methods are competitive immunoassay and those based on chromatographic separation followed by non-immunological direct detection (HPLC, LC-MS/MS). Lack of a reference standard for 25OHD has, until recently, been a major issue resulting in poor between-method comparability. Fortunately this should soon improve due to the recent introduction of a standard reference material in human serum (SRM 972) from the National Institute of Standards and Technology (NIST). For immunoassay, specificity can be an issue especially in relation to the proportion of 25OHD2 that is quantified whereas HPLC and LC-MS/MS methods are able to measure the two major vitamin D metabolites 25OHD2 and 25OHD3 independently. HPLC and LC-MS/MS require more expensive equipment and expert staff but this can be offset against lower reagent costs. Increasingly procedures are being developed to semi-automate or automate HPLC and LC-MS/MS but run times remain considerably longer than for immunoassays especially if performed on automated platforms. For most HPLC and LC-MS/MS methods extraction and procedural losses are corrected for by the inclusion of an internal standard which, in part, may account for higher results compared to immunoassay. In general precision of immunoassay, HPLC and LC-MS/MS are comparable and all have the required sensitivity to identify severe vitamin D deficiency. Looking to the future it is hoped that the imminent introduction of a standard reference method (or methods) for 25OHD will further accelerate improvements in between method comparability.  相似文献   

14.
SCH 201781 is a direct thrombin inhibitor recently under study in clinical trials to determine its safety and efficacy for the treatment of venous and arterial thrombosis. In aqueous solution, SCH 201781 exists as three forms, a ring-opened hydrated form and two ring-closed diastereomers. An automated solid-phase extraction LC-MS/MS method that chromatographically separates and measures each form was developed and validated from 1 to 1000 ng/mL in human plasma. For calibration curve standards, within- and between-run precision (%CV) ranged from 0.6 to 13.7%, while accuracy (%bias) ranged from -4.8 to 13.1%. For quality control samples, within- and between-run %CV ranged from 1.5 to 9.9% while %bias ranged from -9.1 to 4.9%. The method requires a sample volume of 0.8 ml and utilizes 2H6-labeled SCH 201781 as the internal standard. For sample processing, an Isolute C-8 96-well solid phase extraction plate and a Tomtec Quadra 96 sample processor is employed. Separation of the three forms of SCH 201781 is achieved using a 5 microm, 2 mm x 100 mm Asahipak C8 HPLC column and gradient elution. A Sciex API 365 equipped with a turbo ionspray source is used in the selected reaction monitoring mode for detection. The validated method was used to support clinical studies.  相似文献   

15.
A highly precise and sensitive method for the estimation of indapamide in human whole blood using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) is described. The method developed is validated in human whole-blood matrix, with a sensitivity of 0.5 ng/ml as lower limit of quantification. The procedure for the extraction of indapamide and glimepiride as internal standard (IS) involves haemolysis and deprotienation of whole blood using ZnSO(4) followed by liquid-liquid extraction using ethyl acetate. The sample extracts after drying were reconstituted and analysed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the positive ion and selective reaction monitoring (SRM) acquisition mode to quantify indapamide in human whole blood. The mean recovery for indapamide was 82.40 and 93.23% for IS. The total run time was 2.5 min to monitor both indapamide and the IS. The response of the LC-MS/MS method for indapamide was linear over the range of 0.5-80.0 ng/ml with correlation coefficient, r>or=0.9991. The coefficient of variance (% CV) at 0.5 ng/ml was 4.02% and the accuracy was well within the accepted limit of +/-20% at 0.5 ng/ml and +/-15% at all other concentrations in the linear range. This method is fully validated for the accuracy, precision and stability studies and also applied to subject-sample analysis of bioequivalence study for 1.5mg sustained-release (SR) formulations.  相似文献   

16.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of clonidine in human plasma. Clonidine was extracted from human plasma by using solid-phase extraction technique. Nizatidine was used as the internal standard. A Hypurity C18 (50 mm x 4.6 mm i.d., 5 microm particle size) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection up to picogram levels with a total run time of 3.0 min only. The method was validated over the range of 50-2500 pg/mL. The absolute recoveries for clonidine (71.86%) and IS (69.44%) achieved from spiked plasma samples were consistent and reproducible.  相似文献   

17.
An analytical method for the determination of benazepril and its active metabolite, benazeprilat, in human plasma by capillary gas chromatography-mass-selective detection, with their respective labelled internal standard, was developed and validated according to international regulatory requirements. After addition of the internal standards, the compounds were extracted from plasma by solid-phase extraction using automated 96-well plate technology. After elution, the compounds were converted into their methyl ester derivatives by means of a safe and stable diazomethane derivative. The methyl ester derivatives were determined by gas chromatography using a mass-selective detector at m/z 365 for benazepril and benazeprilat and m/z 370 for the internal standards. Intra- and inter-day accuracy and precision were found to be suitable over the range of concentrations between 2.50 and 1000 ng/mL.  相似文献   

18.
A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for use in pharmacokinetic studies in order to determine the concentrations of monensin in plasma and edible tissues of chicken. Two sample preparations were performed, one for determining monensin concentrations in plasma using acetonitrile for protein precipitation and another one for determining monensin concentrations in muscle, liver, and fat using methanol-water followed by a clean up on a solid-phase extraction cartridge. Sample extracts were injected into the LC-MS/MS system, and a gradient elution was performed on a C18 column. Narasin was used as internal standard. The LC-MS/MS method was validated using an approach based on accuracy profiles, and applicability of the method was demonstrated for the determination of monensin in chicken plasma, muscle, liver, and fat in a pharmacokinetic study.  相似文献   

19.
Nateglinide (NTG), an insulin secretogogue, has been studied in rats for drug-drug interaction with cilostazol (CLZ), an antiplatelet agent commonly used in diabetics. We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) based method that is capable of simultaneous monitoring plasma levels of nateglinide, cilostazol, and its active metabolite 3,4-dehydro-cilostazol (DCLZ). All analytes including the internal standard (Repaglinide) were chromatographed on reverse phase C(18) column (50 mm x 4.6mm i.d., 5 microm) using acetonitrile: 2mM ammonium acetate buffer, pH 3.4 (90:10, v/v) as mobile phase at a flow rate 0.4 ml/min in an isocratic mode. The detection of analyte was performed on LC-MS/MS system in the multiple reaction monitoring (MRM) mode. The quantitations for analytes were based on relative concentration. The method was validated over the concentration range of 20-2000 ng/ml and the lower limit of quantitation was 20 ng/ml. The recoveries from spiked control samples were >79% for all analytes and internal standard. Intra- and inter-day accuracy and precision of validated method were with in the acceptable limits of <15% at all concentration. The quantitation method was successfully applied for simultaneous estimation of NTG, CLZ and DCLZ in a pharmacokinetic drug-drug interaction study in Wistar rats.  相似文献   

20.
A fast and sensitive LC-MS/MS method for the quantitative analysis of seven steroid hormones in 150 μl of human serum was developed and validated. The following compounds were included: 17α-hydroxypregnenolone, 17α-hydroxyprogesterone, androstenedione, dehydroepiandrosterone, testosterone, pregnenolone, and progesterone. Individual stable isotope-labeled analogues were used as internal standards. Sample preparation was performed by liquid-liquid extraction, followed by oxime derivatization to improve the ionization efficiency of the analytes. In contrast to the common derivatization-based methods, the reaction was incorporated into the sample preparation process and the only additional step due to the derivatization was a short heating of the autosampler vials before the sample injection. Chromatographic separation was achieved on a reversed-phase column using a methanol-water gradient. For the analyte detection, a triple quadrupole instrument with electrospray ionization was used. Total run time was 7.0 min and the lower limits of quantification were in the range of 0.03-0.34 nM (0.01-0.10 ng/ml), depending on the analyte. The method was validated using human serum samples from both sexes and applied for the serum steroid profiling of endometriosis patients.  相似文献   