首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-performance liquid chromatography with on-line electrospray ionization mass spectrometry (ESI-LC/MS) was investigated for the analysis of carbohydrate heterogeneity using RNase B as a model glycoprotein. Oligosaccharides released from RNase B with endoglycosidase H were reduced and separated on a graphitized carbon column (GCC). GCC-HPLC/MS in the positive-ion mode was successful in the identification of one Man5GlcNAc, three Man6GlcNAc, three Man7GlcNAc, three Man8GlcNAc, one Man9GlcNAc, and an oligosaccharide having six hexose units (Hex) and two N-acetylhexosamine units (HexNAc). The branch structures of the three Man7GlcNAc isomers were determined by liquid chromatography with tandem mass spectrometry (LC/MS/MS). LC/MS/MS analysis was shown to be useful for the detection and identification of a trace amount of Hex6HexNAc2 alditol as a hybrid-type oligosaccharide. Its structure was confirmed by the combination of LC/MS with enzymatic digestion using beta-galactosidase and N-acetyl-beta-glucosaminidase. The relative quantities of high-mannose-type oligosaccharides in RNase B detected by ESI-LC/MS are in reasonable agreement with those by UV, high-pH anion-exchange chromatography with pulsed amperometric detection, fluorophore-assisted carbohydrate electrophoresis. Our results indicate that LC/MS and LC/MS/MS can be utilized to elucidate the distribution of oligosaccharides and their structures, which differ in molecular weight, sugar sequence, and branch structure.  相似文献   

2.
高压液色谱用于肠通透性的测定   总被引:5,自引:0,他引:5  
目的 建立一种测定肠通透性的可靠方法。方法 以甘露醇和乳果糖为探测剂,用带脉冲电化学检测器的高压液相色谱仪对20例健康成人样品中的甘露醇和乳果糖进行检测。结果 20个样品中的甘露醇和乳果糖均被检测到,其最低质量浓度分别为0.2028mg/L和0.1930mg/L,回收率分别为98.2%和104.3%。结论 用带脉冲电化学检测器的高压液相色谱仪测定尿中的甘露醇和乳果糖是一种灵敏度高,特异性强,操作简  相似文献   

3.
A simple and rapid method using liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of 130 veterinary drugs and their metabolites in bovine, porcine, and chicken muscle was developed. The drugs (1 to 10 ng/g, in muscle) were extracted from bovine, porcine, or chicken muscles with acetonitrile-methanol (95:5, v/v), and the extracts were delipidated with n-hexane saturated with acetonitrile. The extracts were evaporated, dissolved with methanol, analyzed by liquid chromatography with gradient elution on a C18 column, and determined by electrospray ionization tandem mass spectrometry. The detection limits ranged from 0.03 to 3 ng/g. The quantitation limits ranged from 0.1 to 10 ng/g. One hundred eleven, 122, and 123 drugs from bovine, porcine, and chicken muscle respectively showed recoveries between 70 and 110%.  相似文献   

4.
High-performance liquid chromatography with electrospray ionization mass spectrometry (LC/MS) and liquid chromatography with tandem mass spectrometry (LC/MS/MS) were applied to the analysis of the site-specific carbohydrate heterogeneity in erythropoietin (EPO) used as a model of the sialylated glycoprotein. N-linked oligosaccharides were released from recombinant human EPO expressed in Chinese hamster ovary cells enzymatically and reduced with NaBH(4). Many different sialylated oligosaccharides of EPO were separated and characterized by LC/MS equipped with a graphitized carbon column (GCC). Glycosylation sites and the preliminary glycosylation pattern at each glycosylation site were determined by LC/MS of endoproteinase Glu-C-digested EPO. The detailed site-specific carbohydrate heterogeneity caused by the differences in the molecular weight, branch, linkage, and sequence was elucidated by GCC-LC/MS of the N-linked oligosaccharides released from the isolated glycopeptides. Structural details of the isomers were analyzed by LC/MS/MS, and it was indicated that di- and trisialylated tetraantennary oligosaccharides are attached to Asn24, 38, and 83, whereas their isomers, di- and trisialylated triantennary oligosaccharides containing N-acetyllactosamines, are combined with Asn24. Our method is useful for the determination of glycosylation sites, the site-specific carbohydrate heterogeneity of glycoproteins, and the carbohydrate structure.  相似文献   

5.
N-linked oligosaccharides were released from human and bovine polyclonal immunoglobulin G (IgG) obtained from commercial sources and also from a monoclonal IgG(1) secreted by murine B-lymphocyte hybridoma cells (CC9C10) grown under different serum-free conditions. These conditions differed according to their steady-state dissolved oxygen concentrations. This work is based on a previous quantitative study where released glycans were characterized by fluorophore-assisted carbohydrate electrophoresis (FACE) and high-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) (J. P. Kunkel, D. C. H. Jan, J. C. Jamieson, and M. Butler, 1998, J. Biotechnol. 62, 55-71). In the present article, peptide-N-glycosidase F-released glycans from different species of polyclonal IgG and murine monoclonal IgG were characterized qualitatively by high-performance liquid chromatography (HPLC) coupled to electrospray ionization mass spectrometry (ESI-MS). The glycans were also analyzed by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The MALDI mass spectrometer used allowed acquisition of MS and tandem MS data, which were useful in structural investigations at a more detailed level than allowed by FACE and HPAEC-PAD. Predominant N-linked structures, as determined by all techniques, were core-fucosyl asialyl biantennary chains with varying galactosylation. Minor amounts of afucosyl, bisected, and monosialyl oligosaccharides were also detected. In contrast to FACE and HPAEC-PAD, MALDI-double quadrupole/time-of-flight MS and HPLC/ESI-MS also detected low-abundance high-mannose and hybrid structures in some of the species under investigation.  相似文献   

6.
Squalene has been used as a dietary supplement for a long history due to its potential cancer‐preventive function. However, the mechanism has not been investigated in detail yet. Therefore, the aim of this study is to see if the plasma coenzyme Q10 (CoQ10) level will be altered by gavage of squalene and oxidosqualenes to rats. In the present work, a sensitive and simple high‐performance analytical method based on ultra‐high‐performance liquid chromatography coupled with an Orbitrap mass spectrometry (UPLC‐Orbitrap‐MS) was developed for the quantification of CoQ10 in rat plasma. Coenzyme Q9 (CoQ9) was employed as the internal standard. CoQ10 was determined after acetonitrile‐mediated plasma protein precipitation using UPLC‐Orbitrap‐MS in negative ion mode. Intragastric administration of squalene and the two squalene epoxides into rats once daily for several days elevated the level of CoQ10 in their plasma, but there was no significant difference between high‐dose (286 mg/kg) and low‐dose (143 mg/kg) groups. Intragastric administration of squalene once a day for 5 consecutive days and oxidosqualenes once a day for 3 consecutive days is necessary for reaching the steady‐state level of CoQ10. Our present findings indicate that squalene and oxidosqualenes may be useful for stimulating the synthesis of CoQ10 in rats.  相似文献   

7.
Mung bean protein isolates were hydrolyzed for 2 h by Alcalase. The generated hydrolysate showed angiotensin I-converting enzyme (ACE) inhibitory activity with the IC(50) value of 0.64 mg protein/ml. Three kinds of novel ACE inhibitory peptides were isolated from the hydrolysate by Sephadex G-15 and reverse-phase high performance liquid chromatography (RP-HPLC). These peptides were identified by amino acid composition analysis and matrix assisted-laser desorption/ionization time-of-flight tandem mass spectrometry (MALDI-TOF MS/MS), as Lys-Asp-Tyr-Arg-Leu, Val-Thr-Pro-Ala-Leu-Arg and Lys-Leu-Pro-Ala-Gly-Thr-Leu-Phe with the IC(50) values of 26.5 microM, 82.4 microM and 13.4 microM, respectively.  相似文献   

8.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

9.
Desorption electrospray ionization (DESI) was utilized to monitor the presence of targeted central carbon metabolites within bacterial cell extracts and the quench supernatant of Escherichia coli. The targeted metabolites were identified through tandem mass spectrometry (MS/MS) product ion scans using collision-induced dissociation in the negative ion mode. Picogram detection limits were achieved for a majority of the metabolites during MS/MS analysis of standard metabolite solutions. In a [U-(13)C]glucose pulse experiment, where uniformly labeled glucose was fed to E. coli, the corresponding fragment ions from labeled metabolites in extracts were generally observed. There was evidence of matrix effects including moderate suppression by other metabolites within the spectra of the labeled and unlabeled extracts. To improve the specificity and sensitivity of detection, optimized in situ ambient chemical reactions using DESI and extractive electrospray ionization (EESI) were carried out for targeted compounds. This study provides the first indication of the potential to perform in situ targeted metabolomics of a bacterial sample via ambient ionization mass spectrometry.  相似文献   

10.
We investigated the application of 1-alkylamines, as additives to the mobile phase, to a quantification method for ubiquinone-9 (CoQ9) and ubiquinone-10 (CoQ10) in rat thigh muscle and heart using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the optimization of the analytical method, we found that 1-alkylamines mixed with CoQ9 and CoQ10 in the turbo ion sprayed solution formed the 1-alkylammonium adduct molecules of these compounds during the ionization process and that the intensity of the adduct ions was considerably higher than that of the protonated molecules ([M+H]+) of these compounds. Furthermore, we investigated a variety of 1-alkylamines in the mobile phase for LC-MS/MS analysis to select the most appropriate 1-alkylamine for higher sensitivities of CoQ9 and CoQ10. After these examinations, we found that methylamine was the most suitable additive for the mobile phase, allowing a 12.5-fold gain in signal intensity in the full ion mass spectrum compared with that without methylamine. The internal standard (IS) used was ubiquinone-11 (CoQ11) for each analyte. The analytes and IS were extracted with methanol from the tissue homogenates at neutral pH and were injected into an LC-MS/MS with a turbo ion spray interface. The calibration curves for CoQ9 (5-500 microg/g in thigh muscle and 50-10,000 microg/g in heart) and CoQ10 (1-500 microg/g in thigh muscle and 10-10,000 microg/g in heart) showed good linearity. The method was precise; the relative standard deviations of the method for rat thigh muscle were not more than 13.5 and 9.0% for CoQ9 and CoQ10, respectively, and those for rat heart were not more than 6.7 and 5.4% for CoQ9 and CoQ10, respectively. The accuracies of the method for both rat thigh muscle and heart were good, with the deviations between the nominal concentration and calculated concentration of CoQ9 and CoQ10 typically being within 12.3 and 4.3%, respectively. This method provided reliable concentration levels for CoQ9 and CoQ10 in rat thigh muscle and heart.  相似文献   

11.
The quantitative analysis of fatty acid composition in atherosclerotic plaques provides a way to monitor the underlying etiology of atherosclerosis. Previously, the method of choice for analyzing fatty acids in biological samples was gas chromatography/mass spectrometry (GC/MS); however, recent developments in electrospray ionization (ESI)/liquid chromatography (LC)/tandem mass spectrometry have made it a superior alternative. Previous research has largely focused on global analyses of intact lipids rather than more targeted analysis of the fatty acids themselves. We have now developed a targeted, stable isotope dilution LC-electrospray ionization/multiple reaction monitoring/MS method for the quantitative analysis of 10 fatty acids (myristic, palmitic, stearic, oleic, linoleic, alpha-linolenic, gamma-linolenic, arachidonic, eicosapentaenoic, and docosahexaenoic acids) using their trimethylaminoethyl ester (TMAE) derivatives to improve sensitivity. The method was validated, had a detection limit in the fmol range, and was used in the analysis of fatty acids in atherosclerotic plaques from carotid arteries.  相似文献   

12.
Meloxicam was quantified in human plasma after a single 15 mg oral dose of the drug was given to 26 healthy volunteers. An Applied Biosystems Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray (TIS) in the positive ion mode, was used. Protein precipitation with acetonitrile was followed by C(18) reverse phase liquid chromatography and tandem mass spectrometry. The mean recovery for meloxicam was 92% with a lower limit of quantification of 8.96 ng/ml. Piroxicam was used as the internal standard. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometry (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of meloxicam in human plasma than has previously been described.  相似文献   

13.
We developed a capillary column gas chromatography (CCGC) method for the measurement of urinary sucralose (S) and three other sugar probes including, sucrose, lactulose (L) and mannitol (M) for use in in vivo studies of intestinal permeability. We compared the capillary method with a packed column gas chromatography (PCGC) method. We also investigated a possible role for sucralose as a probe for the measurement of whole gut permeability. Sample preparation was rapid and simple. The above four sugars were detected precisely, without interference. We measured intestinal permeability using 5- and 24-h urine collections in 14 healthy volunteers. The metabolism of sugars was evaluated by incubating the intestinal bacteria with an iso-osmolar mixture of mannitol, lactulose and sucralose at 37 degrees C for 19 h. Sugar concentrations and the pH of the mixture were monitored. The use of the CCGC method improved the detection of sucralose as compared to PCGC. The average coefficient of variation decreased from 15% to 4%. It also increased the sensitivity of detection by 200-2000-fold. The GC assay was linear between sucralose concentrations of 0.2 and 40 g/l (r=1.000). Intestinal bacteria metabolized lactulose and acidified the media but did not metabolize sucralose or mannitol. The new method for the measurement of urinary sucralose permits the simultaneous quantitation of sucrose, mannitol and lactulose, and is rapid, simple, sensitive, accurate and reproducible. Because neither S nor M is metabolized by intestinal bacteria, and because only a tiny fraction of either sugar is absorbed, this pair of sugar probes appears to be available for absorption throughout the GI tract. Thus, the 24-h urinary concentrations of S and M, or the urinary S/M ratio following an oral dose of a sugar mixture, might be good markers for whole gut permeability.  相似文献   

14.
This paper evaluates the performances of reversed-phase (RPLC) and ion-pairing chromatography (IPLC) coupled with UV detection for the analysis of a set of 12 catecholamines and related compounds. Different chromatographic columns (porous C18-silica, perfluorinated C18-silica, porous graphitic carbon, monolithic and fused-core silica-based C18 columns) were tested using semi-long perfluorinated carboxylic acids as volatile ion-pairing reagents. Much more promising results were obtained by IPLC than by RPLC and important improvements in analytes peak symmetry and separation resolution were observed when using the "fast chromatography" columns (monolithic and fused-core C18) under IPLC conditions. For UV detection, a satisfactory separation of the 12 selected analytes was achieved in less than 20 min by using a fused-core particles column (Halo C18) and a mobile phase composed of a 1.25 mM nonafluoropentanoic acid aqueous solution and methanol under gradient elution mode. The chromatographic method developed can be directly coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS) in positive ionization mode and 10 solutes among those selected can be observed. The presence of the acidic ion-pairing reagent in the mobile phase makes this system incompatible with negative ionization mode and thus unable to detect the two acidic compounds that only responded in negative mode. In terms of MS detection, Monolithic C18 column proved to be the best one to reach the lowest detection limits (LODs) (from 0.5 ngmL(-1) to 10 ngmL(-1) depending on the neurotransmitter). The applicability of the optimized LC-MS/MS method to a "real world" sample was finally evaluated. The presence of the matrix leads to signal suppression for several solutes and thus to higher LODs.  相似文献   

15.
A new liquid chromatography assay with isocratic elution and tandem mass spectrometry detection (LC-MS/MS) using an electrospray ionization interface in the multiple reaction monitoring mode was developed and validated for ertapenem determination in microdialysate samples. Linearity was demonstrated between 10ngmL(-1) (lower limit of quantification, LLoQ) and 160ngmL(-1). The precision (CV%) and accuracy (bias%) in microdialysates at the LLoQ were respectively 2.2% and 17.3% within-day and 10.6% and 2.7% between-days. Ertapenem was stable for 1 month at -20 degrees C and -80 degrees C but unstable at +4 degrees C. This new LC-MS/MS assay is simple, rapid and more sensitive than previously described assays.  相似文献   

16.
辅酶Q10(CoQ10)是一种脂溶性抗氧化剂,具有提高人体免疫力、延缓衰老和增强人体活力等功能,广泛应用于制药行业和化妆品行业。微生物发酵法能可持续性生产辅酶Q10,具有越来越多的商业价值。本研究首先将来自类球红细菌的十聚异戊二烯焦磷酸合成酶基因(dps)整合到大肠杆菌ATCC 8739染色体上,敲除内源的八聚异戊二烯焦磷酸合成酶基因(ispB),使内源的辅酶Q8合成途径被辅酶Q10合成途径取代,得到稳定生产辅酶Q10的菌株GD-14,其辅酶Q10产量达0.68 mg/L,单位细胞含量达0.54 mg/g DCW。随后用多个固定强度调控元件在染色体上对MEP途径的关键基因dxs和idi基因以及ubiCA基因进行组合调控,将辅酶Q10单位细胞含量提高2.46倍(从0.54到1.87 mg/g)。进一步引入运动发酵单胞菌Zymomonas mobilis的Glf转运蛋白代替自身的磷酸烯醇式丙酮酸:碳水化合物磷酸转移酶系统(PTS),使辅酶Q10产量进一步提高16%。最后,对高产菌株GD-51进行分批补料发酵,辅酶Q10产量达433 mg/L,单位细胞含量达11.7 mg/g DCW。这是目前为止文献报道的大肠杆菌产辅酶Q10最高菌株。  相似文献   

17.
The method for separation and determination of lactulose (L) and mannitol (M) in urine was developed by HPLC with a refractive index detector (RID). The linearity ranged from 5 to 1000 microg/mL for L and M, respectively. Recoveries ranged from 93.1% to 97.1%. The intra- and inter-day relative standard deviations of peak area were between 0.8-1.4% (n=3) and 1.4-3.6% (n=3). The limits of detection were obtained with 1.40 microg/mL for L and 1.65 microg/mL for M. The ratios of L/M in the urine samples for the spontaneous ascitic fluid infection (SAI), sterile ascitic fluid (SA) patients, and healthy volunteers (HV) were determined. The results showed well the correlations among the L/M ratio, intestinal permeability (IP) and the illness status of patients, and also indicated lactulose could improve the IP of SAI patients. The peaks of L and M in chromatograms were identified by electrospray ionization/mass spectrometry (ESI/MS), which ensured the accurate measurement of the ratio L/M. This method presented a rapid, accurate, and practical technique for determining IP in clinical practice and investigating the pathology of hepatocirrhosis.  相似文献   

18.
This study was conducted to characterize metabolic features of the breast muscle (pectoralis major) in chickens affected with the Wooden Breast myopathy. Live birds from two purebred chicken lines and one crossbred commercial broiler population were clinically examined by manual palpation of the breast muscle (pectoralis major) at 47–48 days of age. Metabolite abundance was determined by gas chromatography/mass spectrometry (GC/MS) and liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) using breast muscle tissue samples from 16 affected and 16 unaffected chickens. Muscle glycogen content was also quantified in breast muscle tissue samples from affected and unaffected chickens. In total, levels of 140 biochemicals were significantly different (FDR < 0.1 and fold-change A/U > 1.3 or < 0.77) between affected and unaffected chickens. Glycogen content measurements were considerably lower (1.7-fold) in samples taken from Wooden Breast affected birds when compared with samples from unaffected birds. Affected tissues exhibited biomarkers related to increased oxidative stress, elevated protein levels, muscle degradation, and altered glucose utilization. Affected muscle also showed elevated levels of hypoxanthine, xanthine, and urate molecules, the generation of which can contribute to altered redox homeostasis. In conclusion, our findings show that Wooden Breast affected tissues possess a unique metabolic signature. This unique profile may identify candidate biomarkers for diagnostic utilization and provide mechanistic insight into altered biochemical processes contributing to tissue hardening associated with the Wooden Breast myopathy in commercial chickens.  相似文献   

19.
A sensitive and selective method using high-performance liquid chromatography in combination with atmospheric pressure chemical ionization tandem mass spetrometry (LC-APCI-MS/MS) has been developed for the determination of Deoxynivalenol (DON) in trace levels. The extract was purified with a MultiSep? column followed by the Vicam? DON immunoaffinity column. Quantification is based on an external standard method using positive Multiple Reaction Monitoring (MRM). The limit of detection was 5 μg/kg with a signal to noise ratio of 3:1.  相似文献   

20.
Nonreducing O-linked oligosaccharides were obtained from the peptidorhamnomannan of mycelia of Pseudallescheria boydii by alkaline beta-elimination under reducing conditions. They were separated by gel filtration chromatography to give three oligosaccharide fractions. The major oligosaccharide from fraction 1 was characterized by a combination of techniques including electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI MS/MS), matrix-assisted laser desorption ionization mass spectrometry (MALDI MS), nuclear magnetic resonance (NMR), and methylation gas-liquid chromatography-mass spectrometry (GC-MS) analysis. It was branched, with a principal chain of alpha-Rhap-(1 --> 3)-alpha-Rhap-(1 --> 3)-alpha-Manp-(1 --> 2)-Man-ol substituted at O-6 of mannitol with an alpha-Glcp-(1 --> 4)-beta-Galp group. Species containing one and two additional alpha-Glcp-(1 --> 4) substituents in the rhamnose branch were also present. The major component of fraction 2 was a substructure of oligosaccharide-1, lacking a hexose from the Glc-Gal branch. Fraction 3 contained a mixture of smaller, unbranched, oligosaccharides. In hapten inhibition tests, fractions 1 and 2 blocked the reaction between peptidorhamnomannan (PRM) and rabbit anti-P. boydii mycelium hyperimmune serum by approximately 75%, whereas fraction 3 inhibited by approximately 55%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号