首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The authors describe their experience with access sites for endovascular abdominal aortic aneurysm repair in a group of 165 patients treated over a 10-year period.  相似文献   

2.
The authors describe experience with conversions to open surgery after endovascular abdominal aneurysm repair and evaluate the frequency, causes and results of a total of 7 cases in their series of 165 patients treated over a 10-year period.  相似文献   

3.
Biomechanics and Modeling in Mechanobiology - Non-negligible postinterventional complication rates after endovascular aneurysm repair (EVAR) leave room for further improvements. Since the potential...  相似文献   

4.
Endovascular aneurysm repair (EVAR) can involve some unfavorable complications such as endoleaks or stent-graft (SG) migration. Such complications, resulting from the complex mechanical interaction of vascular tissue, SG and blood flow or incompatibility of SG design and vessel geometry, are difficult to predict. Computational vascular mechanics models can be a predictive tool for the selection, sizing and placement process of SGs depending on the patient-specific vessel geometry and hence reduce the risk of potential complications after EVAR. In this contribution, we present a new in silico EVAR methodology to predict the final state of the deployed SG after intervention and evaluate the mechanical state of vessel and SG, such as contact forces and wall stresses. A novel method to account for residual strains and stresses in SGs, resulting from the precompression of stents during the assembly process of SGs, is presented. We suggest a parameter continuation approach to model various different sizes of SGs within one in silico EVAR simulation which can be a valuable tool when investigating the issue of SG oversizing. The applicability and robustness of the proposed methods are demonstrated on the example of a synthetic abdominal aortic aneurysm geometry.  相似文献   

5.
Blunt abdominal aortic injury is often associated with bowel injury that precludes operative repair because of the risk of graft infection. Endovascular repair has been reported but with limited follow-up. We present a case of a 15-year-old boy who underwent endovascular repair of blunt abdominal aortic rupture and whom we were able to follow up over a decade. Our experience with this case and three others, as well as the experience reported in the literature, suggests that endovascular repair is a reasonable option in the setting of concomitant bowel injury. The risk of over sizing, collapse, and migration may be less than that described for thoracic aortic injuries because there is no need to deploy the endograft across an angle.  相似文献   

6.
Despite rapid expansion of our knowledge of vascular adaptation, developing patient-specific models of diseased arteries is still an open problem. In this study, we extend existing finite element models of stress-mediated growth and remodelling of arteries to incorporate a medical image-based geometry of a healthy aorta and, then, simulate abdominal aortic aneurysm. Degradation of elastin initiates a local dilatation of the aorta while stress-mediated turnover of collagen and smooth muscle compensates the loss of elastin. Stress distributions and expansion rates during the aneurysm growth are studied for multiple spatial distribution functions of elastin degradation and kinetic parameters. Temporal variations of the degradation function are also investigated with either direct time-dependent degradation or stretch-induced degradation as possible biochemical and biomechanical mechanisms for elastin degradation. The results show that this computational model has the capability to capture the complexities of aneurysm progression due to variations of geometry, extent of damage and stress-mediated turnover as a step towards patient-specific modelling.  相似文献   

7.
Despite rapid expansion of our knowledge of vascular adaptation, developing patient-specific models of diseased arteries is still an open problem. In this study, we extend existing finite element models of stress-mediated growth and remodelling of arteries to incorporate a medical image-based geometry of a healthy aorta and, then, simulate abdominal aortic aneurysm. Degradation of elastin initiates a local dilatation of the aorta while stress-mediated turnover of collagen and smooth muscle compensates the loss of elastin. Stress distributions and expansion rates during the aneurysm growth are studied for multiple spatial distribution functions of elastin degradation and kinetic parameters. Temporal variations of the degradation function are also investigated with either direct time-dependent degradation or stretch-induced degradation as possible biochemical and biomechanical mechanisms for elastin degradation. The results show that this computational model has the capability to capture the complexities of aneurysm progression due to variations of geometry, extent of damage and stress-mediated turnover as a step towards patient-specific modelling.  相似文献   

8.
9.
Abdominal aortic aneurysms (AAA) are characterized by pathological remodeling of the aortic extracellular matrix (ECM). However, besides the well-characterized elastolysis and collagenolysis little is known about changes in other ECM proteins. Previous proteomics studies on AAA focused on cellular changes without emphasis on the ECM. In the present study, ECM proteins and their degradation products were selectively extracted from aneurysmal and control aortas using a solubility-based subfractionation methodology and analyzed by gel-liquid chromatography-tandem MS and label-free quantitation. The proteomics analysis revealed novel changes in the ECM of AAA, including increased expression as well as degradation of collagen XII, thrombospondin 2, aortic carboxypeptidase-like protein, periostin, fibronectin and tenascin. Proteomics also confirmed the accumulation of macrophage metalloelastase (MMP-12). Incubation of control aortic tissue with recombinant MMP-12 resulted in the extensive fragmentation of these glycoproteins, most of which are novel substrates of MMP-12. In conclusion, our proteomics methodology allowed the first detailed analysis of the ECM in AAA and identified markers of pathological ECM remodeling related to MMP-12 activity.  相似文献   

10.
The authors describe their experience with the use of 21 open surgical corrections after endovascular abdominal aneurysm repair, reporting the frequency, type and outcome of these procedures in their group of 165 patients treated during a 10-year period.  相似文献   

11.
12.
Aortic valve disease (AVD) occurs in 2.5% of the general population and often requires surgical intervention. Aortic valve malformation (AVM) underlies the majority of cases, suggesting a developmental etiology. Elastin haploinsufficiency results in complex cardiovascular problems, and 20-45% of patients have AVM and/or AVD. Elastin insufficient (Eln+/-) mice demonstrate AVM and latent AVD due to abnormalities in the valve annulus region. The objective of this study was to examine extracellular matrix (ECM) remodeling and biomechanical properties in regional aortic valve tissue and determine the impact of early AVM on late AVD in the Eln+/- mouse model. Aortic valve ECM composition and remodeling from juvenile, adult, and aged stages were evaluated in Eln+/- mice using histology, ELISA, immunohistochemistry and gelatin zymography. Aortic valve tissue biomechanical properties were determined using micropipette aspiration. Cartilage-like nodules were demonstrated within the valve annulus region at all stages identifying a developmental abnormality preceding AVD. Interestingly, maladaptive ECM remodeling was observed in early AVM without AVD and worsened with late AVD, as evidenced by increased MMP-2 and MMP-9 expression and activity, as well as abnormalities in ADAMTS-mediated versican processing. Cleaved versican was increased in the valve annulus region of aged Eln+/- mice, and this abnormality correlated temporally with adverse alterations in valve tissue biomechanical properties and the manifestation of AVD. These findings identify maladaptive ECM remodeling in functional AVM as an early disease process with a progressive natural history, similar to that seen in human AVD, emphasizing the importance of the annulus region in pathogenesis. Combining molecular and engineering approaches provides complementary mechanistic insights that may be informative in the search for new therapeutic targets and durable valve bioprostheses.  相似文献   

13.
Focusing on a representative abdominal aortic aneurysm (AAA) with a bifurcating stent-graft (SG), a fluid-structure interaction (FSI) solver with user-supplied programs has been employed to solve for blood flow, AAA/SG deformation, sac pressure and wall stresses, as well as the downward forces acting on the SG. Simulation results indicate that implanting a SG can significantly reduce sac pressure, mechanical stress, pulsatile wall motion, and maximum diameter change in AAAs; hence, it may restore normal blood flow and prevent AAA rupture effectively. The transient SG drag force is similar in trend as the cardiac pressure. Its magnitude depends on multi-factors including blood flow conditions, as well as SG and aneurysm geometries. Specifically, AAA neck angle, iliac bifurcation angle, neck aorta-to-iliac diameter ratio, SG size, and blood waveform play important roles in generating a fluid flow force potentially leading to SG migration. It was found that the drag force can exceed 5N for an AAA with a large neck or iliac angle, wide aortic neck and narrow iliac arteries, large SG size, and/or abnormal blood waveform. Thus, the fixation of self-expandable or balloon-expandable SG contact may be inadequate to withstand the forces of blood flowing through the implant and hence means of extra fixation should be considered. A comprehensive FSI analysis of the coupled SG-AAA dynamics provides physical insight for evaluating the luminal hemodynamics, and maximum AAA-stresses as well as biomechanical factors leading potentially to SG migration.  相似文献   

14.
15.
Between 1960 and 1979 528 patients with abdominal aortic aneurysms presented to the university department of surgery. Of these, 222 (42%) were elective cases, 72 acute (14%), 174 had ruptured (33%), and four had had a spontaneous aortoduodenal fistula (1%). In all these patients resections were undertaken, but in another 56 patients (11%) the aneurysm was not resected. A review of these cases showed that 91% had symptoms at their first presentation; abdominal pain and backache being most common. The diagnosis could be established in 91% by the presence of pulsatile abdominal mass on clinical examination. The operative mortality for elective resection was 8%, for acute 19%, for ruptured cases 42%, and for spontaneous aortoduodenal fistula 50%. After successful resection the overall five-year survival was 65% by the life table method, and there was no significant difference between elective, acute, and ruptured cases. This five-year survival after resection compares favourably with the expected 76% survival of a similar normal population, and was considerably better than that for conservatively treated patients. As most cases have symptoms, and diagnosis may be established easily by routine physical examination in 91%, the prognosis for this condition could be considerably improved by increased awareness of its existence and early referral for treatment as an elective surgical procedure.  相似文献   

16.
Abdominal aortic aneurysm (AAA) can be defined as a permanent and irreversible dilation of the infrarenal aorta. AAAs are often considered to be an aorta with a diameter 1.5 times the normal infrarenal aorta diameter. This paper describes a technique to manufacture realistic silicone AAA models for use with experimental studies. This paper is concerned with the reconstruction and manufacturing process of patient-specific AAAs. 3D reconstruction from computed tomography scan data allows the AAA to be created. Mould sets are then designed for these AAA models utilizing computer aided designcomputer aided manufacture techniques and combined with the injection-moulding method. Silicone rubber forms the basis of the resulting AAA model. Assessment of wall thickness and overall percentage difference from the final silicone model to that of the computer-generated model was performed. In these realistic AAA models, wall thickness was found to vary by an average of 9.21%. The percentage difference in wall thickness recorded can be attributed to the contraction of the casting wax and the expansion of the silicone during model manufacture. This method may be used in conjunction with wall stress studies using the photoelastic method or in fluid dynamic studies using a laser-Doppler anemometry. In conclusion, these patient-specific rubber AAA models can be used in experimental investigations, but should be assessed for wall thickness variability once manufactured.  相似文献   

17.
During the last years endovascular aneurysm repair (EVAR) became the elective treatment for abdominal aortic aneurysms (AAAs) thanks to lower mortality and morbidity rates than open surgery. In face of these advantages, stent-graft performances are still clinically suboptimal. In particular, post-surgical complications derive from device migration as a consequence of the hemodynamic forces acting on the endograft. In this regard, while the importance of hemodynamic surface forces is well recognized, the role of the in-stent flow is still unclear. Here we hypothesize that in-stent helical blood flow patterns might influence the distribution of the displacement forces (DFs) acting on the stent-graft and, ultimately, the risk of stent migration. To test this hypothesis, the hemodynamics of 20 post-EVAR models of patients treated with two different commercial endografts was analyzed using computational hemodynamics.The main findings of the study indicate that: (1) helical flow intensity decreases the risk of endograft migration, as given by an inverse correlation between helicity intensity (h2) and time-averaged displacement forces (TADFs) (p < 0.05); (2) unbalanced counter-rotating helical structures in the legs of the device contribute, in particular along the systole, to significantly suppress TADFs (p < 0.01); (3) as expected, helical flow intensity is positively correlated with pressure drop and resistance to flow (p < 0.001). The findings of this study suggest that a design strategy promoting in-stent helical flow structures could contribute to minimize the risk of migration of implanted EVAR devices.  相似文献   

18.

Background

Pharmacotherapy may represent a potential means to limit the expansion rate of abdominal aortic aneurysms (AAAs). Studies evaluating the efficacy of different pharmacological agents to slow down human AAA-expansion rates have been performed, but they have never been systematically reviewed or summarized.

Methods and Findings

Two independent reviewers identified studies and selected randomized trials and prospective cohort studies comparing the growth rate of AAA in patients with pharmacotherapy vs. no pharmacotherapy. We extracted information on study interventions, baseline characteristics, methodological quality, and AAA growth rate differences (in mm/year). Fourteen prospective studies met eligibility criteria. Five cohort studies raised the possibility of benefit of beta-blockers [pooled growth rate difference: −0.62 mm/year, (95%CI, −1.00 to −0.24)], but this was not confirmed in three beta-blocker RCTs [pooled RCT growth rate difference: −0.05 mm/year (−0.16 to 0.05)]. Statins have been evaluated in two cohort studies that yield a pooled growth rate difference of −2.97 (−5.83 to −0.11). Doxycycline and roxithromycin have been evaluated in two RCTs that suggest possible benefit [pooled RCT growth rate difference: −1.32 mm/year (−2.89 to 0.25)]. Studies assessing NSAIDs, diuretics, calcium channel blockers and ACE inhibitors, meanwhile, did not find statistically significant differences.

Conclusions

Beta-blockers do not appear to significantly reduce the growth rate of AAAs. Statins and other anti-inflammatory agents appear to hold promise for decreasing the expansion rate of AAA, but need further evaluation before definitive recommendations can be made.  相似文献   

19.
20.

Background  

Abdominal aortic aneurysm (AAA) is a prevalent disease which is of significant concern because of the morbidity associated with the continuing expansion of the abdominal aorta and its ultimate rupture. The transient interaction between blood flow and the wall contributes to wall stress which, if it exceeds the failure strength of the dilated arterial wall, will lead to aneurysm rupture. Utilizing a computational approach, the biomechanical environment of virtual AAAs can be evaluated to study the affects of asymmetry and wall thickness on this stress, two parameters that contribute to increased risk of aneurysm rupture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号