首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Autologous breast reconstruction with the extended latissimus dorsi flap   总被引:10,自引:0,他引:10  
Chang DW  Youssef A  Cha S  Reece GP 《Plastic and reconstructive surgery》2002,110(3):751-9; discussion 760-1
The extended latissimus dorsi myocutaneous flap can provide autogenous tissue replacement of breast volume without an implant. Nevertheless, experience with the extended latissimus dorsi flap for breast reconstruction is relatively limited. In this study, the authors evaluated their experience with the extended latissimus dorsi flap for breast reconstruction to better understand its indications, limitations, complications, and clinical outcomes. All patients who underwent breast reconstruction with extended latissimus dorsi flaps at the authors' institution between January of 1990 and December of 2000 were reviewed. During the study period, 75 extended latissimus dorsi flap breast reconstructions were performed in 67 patients. Bilateral breast reconstructions were performed in eight patients, and 59 patients underwent unilateral breast reconstruction. There were 45 immediate and 30 delayed reconstructions. Mean patient age was 51.5 years. Mean body mass index was 31.8 kg/m2. Flap complications developed in 21 of 75 flaps (28.0 percent), and donor-site complications developed in 29 of 75 donor sites (38.7 percent). Mastectomy skin flap necrosis (17.3 percent) and donor-site seroma (25.3 percent) were found to be the most common complications. There were no flap losses. Patients aged 65 years or older had higher odds of developing flap complications compared with those 45 years or younger (p = 0.03). Patients with size D reconstructed breasts had significantly higher odds of flap complications compared with those with size A or B reconstructed breasts (p = 0.05). Obesity (body mass index greater than or equal to 30 kg/m2) was associated with a 2.15-fold increase in the odds of developing donor-site complications compared with patients with a body mass index less than 30 kg/m2 (p = 0.01). No other studied factors had a significant relationship with flap or donor-site complications. In most patients, the extended latissimus dorsi flap alone, without an implant, can provide good to excellent autologous reconstruction of small to medium sized breasts. In selected patients, larger breasts may be reconstructed with the extended latissimus dorsi flap alone. This flap's main disadvantage is donor-site morbidity with prolonged drainage and risk of seroma. Patients who are obese are at higher risk of developing these donor-site complications. In conclusion, the extended latissimus dorsi flap is a reliable method for total autologous breast reconstruction in most patients and should be considered more often as a primary choice for breast reconstruction.  相似文献   

2.
The free latissimus dorsi skin-muscle flap has gained wide popularity to solve a variety of difficult reconstructive surgical problems. However, the donor site of this skin-muscle flap leaves a conspicuous scar and indentation, and frequently in the recipient site the skin-muscle flap leaves a conspicuous scar and indentation, and frequently in the recipient site the skin-muscle flap requires staged defatting procedures. This case demonstrates the use of the latissimus dorsi muscle flap for lower-extremity reconstruction, where a new blood supply and soft-tissue coverage are required to solve a chronically infected, open ankle joint. By taking the latissimus muscle only through a short, axillary incision, much of the donor-site deformity is minimized, and after transfer, the muscle can be molded and shaped to fit the recipient site with split-thickness skin graft coverage. This combination of free muscle flap transfer and skin graft would appear to provide a flexible, contoured, well-vascularized muscle with a relatively inconspicuous incision and skin-graft donor site.  相似文献   

3.
Aitken ME  Mustoe TA 《Plastic and reconstructive surgery》2002,109(2):525-33; discussion 534-8
Although the latissimus flap is known for its simplicity and reliability, use of the fleur-de-lis pattern was plagued by undesirable T-shaped donor sites and small breast volumes in thin patients. We report a modified technique for optimal shaping of the standard latissimus with the successful application of a modified fleur-de-lis pattern. Because a "wet" tumescent infiltration was utilized and large amounts of subcutaneous fat were harvested, these changes permitted application to a wide variety of patients, with generous breast volumes reducing the size of the implant placed and resulting in excellent donor-site scars.This is a retrospective cohort study of 53 delayed or immediate reconstructions performed consecutively by the principal author (M.E.A.) on 48 patients at a university-based, urban hospital. Each case was analyzed between April of 1995 and February of 1999, with a follow-up from 2.5 to 44 months. All patients underwent injection of tumescent solution into the subcutaneous plane and harvest of large amounts of subcutaneous fat with the neurologically intact latissimus muscle. The last 25 reconstructions utilized the modified fleur-de-lis skin pattern, an inferiorly based vertical limb and replacement of skin deficiency in both axes.Of 11 perioperatively irradiated patients, none required skin grafting, whereas 6 percent of all native mastectomy flaps were grafted. There was one instance of minor distal tip flap necrosis in a nonirradiated patient. No implants became infected or were extruded. Donor sites were without wound complications and unveiled a 16 percent overall seroma rate.Through selective addition of harvested tissue, this modified technique, particularly the fleur-de-lis pattern, permits improved volume and projection in the inferior pole. The T-shaped donor-site closure is not only acceptable, but is also desirable, with reduced wound tension and minimization of dog-ear formation. With a relative paucity of complications, this conceptually ideal modification is technically simple and aesthetically comparable to our transverse rectus abdominis muscle flap results.  相似文献   

4.
Breast reconstruction with a transverse rectus abdominis myocutaneous (TRAM) flap plus an implant has been proposed as an option for women with a thin body habitus who do not have sufficient abdominal tissue to permit reconstruction with a TRAM flap alone. The standard autologous tissue reconstructive procedure in these women is a combined latissimus dorsi myocutaneous flap and breast implant. We reviewed our experience performing TRAM flap/implant and latissimus dorsi flap/implant breast reconstruction to compare complication rates and aesthetic outcomes between these two types of reconstruction. Between 1992 and 1999, 88 breasts were reconstructed at our institution using an autologous tissue flap combined with a breast implant (44 with a TRAM flap/implant and 44 with a latissimus dorsi flap/implant). Recipient-site and donor-site complications for the two procedures were compared using Fisher's exact test; a panel of unbiased, blinded judges compared the aesthetic outcomes. The recipient-site complication rate was lower for the TRAM flap/implant group than for the latissimus dorsi flap/implant group (18 percent versus 34 percent, p = 0.09). Most recipient-site complications in the TRAM flap/implant group were related to fluid collection around the implant. In the TRAM flap/implant group, complications occurred in 37 percent of the reconstructions that had immediate implant placement and in none of the reconstructions with delayed implant placement (p = 0.01). In the TRAM flap/implant reconstructions with immediate implant placement, the recipient-site complication rate was 50 percent when implants were completely filled with saline, but no complications occurred with incompletely filled, postoperatively adjustable implants (p = 0.03). No microvascular complications occurred with immediate placement of breast implants under TRAM flaps. Donor-site complications included a hematoma, a seroma, and an umbilical necrosis in the TRAM flap/implant group and six cases of seroma formation in the latissimus dorsi flap/implant group. The comparison of aesthetic outcome was statistically significant for the TRAM flap/implant group, which had a higher overall mean score than the latissimus dorsi flap/implant group did (3.29 versus 2.85, p = 0.01). The results of this study suggest that the TRAM flap/implant breast reconstruction should be considered as an alternative to the latissimus dorsi flap/implant breast reconstruction in women with a thin body habitus.  相似文献   

5.
The indications for autologous reconstruction are increasing. The standard procedure is the transverse rectus abdominis muscle flap; however, this flap has contraindications and drawbacks. The latissimus dorsi muscle flap is simple and reliable. Hokin et al. demonstrated in 1983 that this flap can be extended and used for breast reconstruction without an implant. Since then, it has been widely studied in this setting and is known to provide good aesthetic results. Dorsal sequelae, conversely, were not appraised. The aim of this study was to assess objective and subjective dorsal sequelae after the harvest of an extended flap. Forty-three consecutive patients who had had breast reconstruction with an autologous latissimus dorsi flap were assessed by a surgeon and a physiotherapist for muscular strength and shoulder mobility. Patient opinion was studied through a questionnaire. Mean delay between the operation and the evaluation was 19 months. Early complications, mainly dorsal seromas, were frequent after the harvest of an extended flap (72 percent). There was no late morbidity and, especially, no flap loss or partial necrosis. As for functional results, 37 percent of the patients had complete adjustment and 70 to 87 percent demonstrated no change in shoulder strength. Sixty percent of the patients experienced no limitation in everyday life, and 90 percent said they would undergo this procedure again. The authors show that dorsal sequelae after an extended latissimus dorsi flap are minimal and that this technique compares favorably with the transverse rectus abdominis muscle flap.  相似文献   

6.
In this report, the authors describe the application of a muscle-sparing technique to harvest a myocutaneous latissimus dorsi muscle flap, including only a tiny lateral muscle segment but carrying a large skin paddle, with the advantage of leaving intact innervation and function of the remaining latissimus dorsi muscle. According to the experiences and complications associated with the pure thoracodorsal artery perforator harvest at the authors' institution, the necessity of increasing the reliability of the vascular pedicle demands that a small muscle strip be left embedding the perforator vessels attached to the skin paddle. This procedure was applied in eight cases with only one minor complication, which was a distal flap tip necrosis in the largest flap used. The muscle function and aesthetic contour of the posterior axillary fold were preserved in every case. Harvesting a large skin paddle flap that is carried by a diminutive longitudinal segment of latissimus dorsi muscle circumvents thoracodorsal nerve damage and maintains muscle function. In contrast to a thoracodorsal artery perforator flap without muscle, the harvesting of which is a delicate procedure, this procedure is regarded as easier and safer.  相似文献   

7.
Endoscopically assisted harvest of free latissimus dorsi muscle flaps is being used more frequently in reconstructive microsurgery because it requires a smaller incision and leaves a more acceptable scar in the donor site. Donor-site morbidity was compared between groups of 22 latissimus dorsi muscles harvested using the endoscopically assisted technique and 26 using the traditional technique. The results revealed no statistically significant differences in the amount of intraoperative bleeding, the incidence of postoperative hematoma and seroma, and the incidence of donor-site wound infection as assessed by the surgeon. However, a patient questionnaire revealed that even though it did not reach a statistically significant difference, endoscopically assisted harvest of the latissimus dorsi muscle had less pain and allowed earlier and better movement of the upper extremity of the donor site. The patients' attitudes and feelings about the scar and overall satisfaction were also higher in the endoscopic group, which demonstrated a statistically significant difference.  相似文献   

8.
Traditional skin free flaps, such as radial arm, lateral arm, and scapular flaps, are rarely sufficient to cover large skin defects of the upper extremity because of the limitation of primary closure at the donor site. Muscle or musculocutaneous flaps have been used more for these defects. However, they preclude a sacrifice of a large amount of muscle tissue with the subsequent donor-site morbidity. Perforator or combined flaps are better alternatives to cover large defects. The use of a muscle as part of a combined flap is limited to very specific indications, and the amount of muscle required is restricted to the minimum to decrease the donor-site morbidity. The authors present a series of 12 patients with extensive defects of the upper extremity who were treated between December of 1999 and March of 2002. The mean defect was 21 x 11 cm in size. Perforator flaps (five thoracodorsal artery perforator flaps and four deep inferior epigastric perforator flaps) were used in seven patients. Combined flaps, which were a combination of two different types of tissue based on a single pedicle, were needed in five patients (scapular skin flap with a thoracodorsal artery perforator flap in one patient and a thoracodorsal artery perforator flap with a split latissimus dorsi muscle in four patients). In one case, immediate surgical defatting of a deep inferior epigastric perforator flap on a wrist was performed to immediately achieve thin coverage. The average operative time was 5 hours 20 minutes (range, 3 to 7 hours). All but one flap, in which the cutaneous part of a combined flap necrosed because of a postoperative hematoma, survived completely. Adequate coverage and complete wound healing were obtained in all cases. Perforator flaps can be used successfully to cover a large defect in an extremity with minimal donor-site morbidity. Combined flaps provide a large amount of tissue, a wide range of mobility, and easy shaping, modeling, and defatting.  相似文献   

9.
The successful use of ipsilateral pedicle latissimus dorsi muscle to restore elbow flexion in a child with arthrogryposis multiplex congenita is described. In appropriately selected patients, use of the latissimus dorsi muscle for elbow flexor reconstruction is a strong, reliable flexorplasty without significant donor-site morbidity.  相似文献   

10.
The use of dynamic myoplasty to restore function to failing organs is an exciting new application of skeletal muscle flaps. A complication of large flap elevation that can compromise flap function is ischemia-induced necrosis; one approach to minimizing this is to pretreat tissues with ischemic preconditioning. The purpose of this study was to determine whether systemic administration of monophosphoryl lipid A, a drug known to mimic late-phase ischemic preconditioning in the heart, could reduce ischemia-induced necrosis in latissimus dorsi muscle flaps. Forty latissimus dorsi muscle flaps from 20 Sprague-Dawley rats were allocated into four groups. In group I (n = 10), flaps were not preconditioned and served as controls. In group II (n = 10), flaps received ischemic preconditioning with two 30-minute periods of ischemia interspersed by 10 minutes of reperfusion. In group III (n = 10), rats received an intravenous bolus of approximately 0.3 ml of monophosphoryl lipid A vehicle only. In group IV (n = 10), rats received an intravenous bolus of 450 microg/kg of monophosphoryl lipid A and vehicle. Twenty-four hours after treatment, all latissimus dorsi muscle flaps were elevated on a single neurovascular pedicle and subjected to 4 hours of ischemia. After 72 hours of reperfusion, latissimus dorsi muscles were harvested, weighed, stained with nitroblue tetrazolium, and assessed for percent necrosis using digitized images of muscle sections and computerized planimetry. The percent necrosis in ischemic preconditioning-treated flaps (group II) was significantly reduced by 57 percent (p < 0.05) compared with control flaps (group I). The percent necrosis in flaps treated with monophosphoryl lipid A (group IV) was significantly reduced by 58 percent (p < 0.05) compared with vehicle-control flaps (group III). There was no difference in mean percent necrosis between ischemic preconditioning (group II) and monophosphoryl lipid A-treated (group IV) flaps or between ischemic preconditioning-control (group I) and monophosphoryl lipid A vehicle-control (group III) flaps. Intravenous administration of systemic monophosphoryl lipid A mimics the late-phase protective effect of ischemic preconditioning in the authors' rat latissimus dorsi muscle flap model.  相似文献   

11.
A case is presented of a bilobed latissimus dorsi flap. The advantage of this flap is to close a large defect without having to resort to a skin graft for closure of the donor-site defect. The advantages of this procedure are as follows: Well-vascularized, stable coverage for decubitus ulcers. Acceptable cosmetic deformity. Avoidance of a skin graft. Decreasing the length of hospitalization.  相似文献   

12.
In cardiomyoplasty, the latissimus dorsi muscle is lifted on its primary neurovascular pedicle and wrapped around a failing heart. After 2 weeks, it is trained for 6 weeks using chronic electrical stimulation, which transforms the latissimus dorsi muscle into a fatigue-resistant muscle that can contract in synchrony with the beating heart without tiring. In over 600 cardiomyoplasty procedures performed clinically to date, the outcomes have varied. Given the data obtained in animal experiments, the authors believe these variable outcomes are attributable to distal latissimus dorsi muscle flap necrosis. The aim of the present study was to investigate whether the chronic electrical stimulation training used to transform the latissimus dorsi muscle into fatigue-resistant muscle could also be used to induce angiogenesis, increase perfusion, and thus protect the latissimus dorsi muscle flap from distal necrosis. After 14 days of chronic electrical stimulation (10 Hz, 330 microsec, 4 to 6 V continuous, 8 hours/day) of the right or left latissimus dorsi muscle (randomly selected) in 11 rats, both latissimus dorsi muscles were lifted on their thoracodorsal pedicles and returned to their anatomical beds. Four days later, the resulting amount of distal flap necrosis was measured. Also, at predetermined time intervals throughout the experiment, muscle surface blood perfusion was measured using scanning laser Doppler flowmetry. Finally, latissimus dorsi muscles were excised in four additional stimulated rats, to measure angiogenesis (capillary-to-fiber ratio), fiber type (oxidative or glycolytic), and fiber size using histologic specimens. The authors found that chronic electrical stimulation (1) significantly (p < 0.05) increased angiogenesis (mean capillary-to-fiber ratio) by 82 percent and blood perfusion by 36 percent; (2) did not reduce the amount of distal flap necrosis compared with nonchronic electrical stimulation controls (29 +/- 5.3 percent versus 26.6 +/- 5.1 percent); (3) completely transformed the normally mixed (oxidative and glycolytic) fiber type distribution into all oxidative fibers; and (4) reduced fiber size in the proximal and middle but not in the distal segments of the flap. Despite the significant increase in angiogenesis and blood perfusion, distal latissimus dorsi muscle flap necrosis did not decrease. This might be because of three reasons: first, the change in muscle metabolism from anaerobic to aerobic may have rendered the muscle fibers more susceptible to ischemia. Second, because of the larger diameter of the distal fibers in normal and stimulated latissimus dorsi muscle, the diffusion distance for oxygen to the center of the distal fibers is increased, making fiber survival more difficult. Third, even though angiogenesis was significantly increased in the flap, cutting all but the single vascular pedicle resulted in the newly formed capillaries not receiving enough blood to provide nourishment to the distal latissimus dorsi muscle. The authors' findings indicate that chronic electrical stimulation as tested in these experiments could not be used to prevent distal latissimus dorsi muscle flap ischemia and necrosis in cardiomyoplasty.  相似文献   

13.
The thin latissimus dorsi perforator-based free flap for resurfacing   总被引:11,自引:0,他引:11  
The authors present their experience with "thin" latissimus dorsi perforator-based free flaps for resurfacing defects. Perforator-based free flaps have been used for various kinds of reconstruction by presenting important donor structures. The thin latissimus dorsi perforatorbased free flap included only the skin and superficial adipose layer to reduce its bulkiness by dissection through the superficial fascial plane. This flap was used in 12 clinical cases, without flap necrosis or other serious postoperative complications. All of the patients were examined by preoperative power Doppler ultrasound in the spectral Doppler mode to search for the most reliable perforator. This noninvasive ultrasound technique determines the exact location and course of and ensures the reliable flow of the perforators; therefore, it greatly assists microsurgeons in saving operation time and in selecting the most suitable design for perforator flap reconstruction. We used perforators that were identified several centimeters from the lateral border of the latissimus dorsi muscle. The thin flap dimensions could be safely designed for flaps measuring up to 20 cm in length and 8 cm in width for primary closure of the donor site. Generally, a long pedicle is not required for resurfacing reconstructions, where small recipient arteries in the bed are acceptable for anastomosis with pedicles. However, pedicle dissection to the proximal vessels through the latissimus dorsi muscle was required when it was necessary to match the recipient vein for anastomosis. The authors conclude that this thin latissimus dorsi perforator-based free flap has great potential for resurfacing because of its constant thickness, easy elevation with the help of power Doppler ultrasound information, and proper flap size for moderate defects caused by scar contracture release, superficial tumor ablation, and so on.  相似文献   

14.
Management of bone loss that occurs after severe trauma of open lower extremity fractures continues to challenge reconstructive surgeons. Sixty-one patients who had 62 traumatic open lower extremity fractures and combined bone and composite soft-tissue defects were treated with the following protocol: extensive debridement of necrotic tissues, eradication of infection, and vascularization of osteocutaneous tissue for one-stage bone and soft-tissue coverage reconstruction. The mechanism of injury included 49 motorcycle accidents (80.3 percent), five falls (8.2 percent), three crush injuries (4.9 percent), two pedestrian-automobile accidents (3.3 percent), and two motor vehicle accidents (3.3 percent). The bone defects were located in the tibia in 49 patients (79 percent; one patient had bilateral open tibial fractures), in the femur in seven patients (11.3 percent), in the calcaneus bone in four patients (6.5 percent), and in the metatarsal bones in two patients (3.2 percent). The size of soft-tissue defects ranged from 5 x 9 cm to 30 x 17 cm. The average length of the preoperative bony defect was 11.7 cm. The average duration from injury to one-stage reconstruction was 27.1 days, and the average number of previous extensive debridement procedures was 3.4. Fifty patients had vascularized fibula osteoseptocutaneous flaps, six had vascularized iliac osteocutaneous flaps, and five patients had seven combined vascularized rib transfers with serratus anterior muscle and/or latissimus dorsi muscle transfers. One patient received a second combined rib flap because the first combined rib flap failed. The rate of complete flap survival was 88.9 percent (56 of 63 flaps). Two combined vascularized rib transfers with serratus anterior muscle and latissimus dorsi muscle flaps were lost totally (3.2 percent) because of arterial thrombosis and deep infection, respectively. Partial skin flap losses were encountered in the five fibula osteoseptocutaneous flaps (7.9 percent). Postoperative infection for this one-stage reconstruction was 7.9 percent. Excluding the failed flap and the infected/amputated limb, the primary bony union rate after successful free vascularized bone grafting was 88.5 percent (54 of 61 transfers). The average primary union time was 6.9 months. The overall union rate was 96.7 percent (59 of 61 transfers). The average time to overall union was 8.5 months after surgery. Seven transferred vascularized bones had stress fractures, for a rate of 11.5 percent. Donor-site problems were noted in six fibular flaps, in two iliac flaps, and in one rib flap. The fibular donor-site problems were foot drop in one patient, superficial peroneal nerve palsy in one patient, contracture of the flexor hallucis longus muscle in two patients, and skin necrosis after split-thickness skin grafting in two patients. The iliac flap donor-site problems were temporary flank pain in one patient and lateral thigh numbness in the other. One rib flap transfer patient had pleural fibrosis. Transfer of the appropriate combination of vascularized bone and soft-tissue flap with a one-stage procedure provides complex lower extremity defects with successful functional results that are almost equal to the previously reported microsurgical staged procedures and conventional techniques.  相似文献   

15.
The delay procedure is known to augment pedicled skin or muscle flap survival. In this study, we set out to investigate the effectiveness of vascular delay in two rabbit muscle flap models. In each of the muscle flap models, a delay procedure was carried out on one side of each rabbit (n = 20), and the contralateral muscle was the control. In the latissimus dorsi flap model, two perforators of the posterior intercostal vessels were ligated. In the biceps femoris flap model, a dominant vascular pedicle from the popliteal artery was ligated. After the 7-day delay period, the bilateral latissimus dorsi flaps (based on the thoracodorsal vessels) and the bilateral biceps femoris flaps (based on the sciatic vessels) were elevated. Animals were divided into three groups: part A, assessment of muscle flap viability at 7 days using the tetrazolium dye staining technique (n = 7); part B, assessment of vascular anatomy using lead oxide injection technique (n = 7); and part C, assessment of total and regional capillary blood flow using the radioactive microsphere technique (n = 6). The results in part A show that the average viable area of the latissimus dorsi flap was 96 +/- 0.4 percent (mean +/- SEM) in the delayed group and 84 +/- 0.7 percent (mean +/- SEM) in the control group (p < 0.05, n = 7), and the mean viable area of the biceps femoris flap was 95 +/- 2 percent in the delayed group and 78 +/- 5 percent in the control group (p < 0.05, n = 7). In part B, it was found that the line of necrosis in the latissimus dorsi flap usually appeared at the junction between the second and third vascular territory in the flap. Necrosis of the biceps femoris flap usually occurred in the third territory, and occasionally in both the second and the third territories. In Part C, total capillary blood flow in delayed flaps (both the latissimus dorsi and biceps femoris) was significantly higher than that in the control flaps (p < 0.05). Increased regional capillary blood flow was found in the middle and distal regions, compared with the control (p < 0.05, n = 6). In conclusion, ligation of either the dominant vascular pedicle in the biceps femoris muscle flap or the nondominant pedicle in the latissimus dorsi muscle flap in a delay procedure 1 week before flap elevation improves capillary blood flow and muscle viability. Vascular delay prevents distal flap necrosis in two rabbit muscle flap models.  相似文献   

16.
The results of 55 breast reconstructions using an extended latissimus dorsi myocutaneous flap without an implant are reported. A method for preoperatively estimating the flap volume, operative details, and a technique for insetting the flap are reviewed. Good, fair, and poor results were achieved in 69, 24, and 7 percent of patients, respectively. Examples are illustrated. The poor results were all due to major complications and are analyzed in detail. Significant complications affecting the end result occurred in 14.5 percent of patients, and nonsignificant and minor complications occurred in 33 percent. Flap volume is shown to be fairly accurately predictable. Seventy percent of flaps had a volume in excess of 400 cc. The reconstructed volume, cosmetic results, and complication rates are compared with those of other reported series. Good results can be achieved with this method, quite comparable to other methods, and with similar complication rates, but without the problems associated with the use of a prosthetic implant.  相似文献   

17.
Ischemia of the distal latissimus dorsi muscle flap occurs when the entire muscle is acutely elevated. Although this level of ischemia may not be critical if the muscle is to be used as a conventional muscle flap, the ischemia causes decreased distal muscle function if it is used for dynamic muscle flap transfer. This experiment was designed to determine whether or not the administration of exogenous basic fibroblast growth factor (bFGF), combined with a sublethal ischemic insult (i.e., vascular delay), would further augment muscle perfusion and function. Both latissimus dorsi muscles of nine canines were subjected to a bipedicle vascular delay procedure immediately followed by thoracodorsal intraarterial injection of 100 microg of bFGF on one side and by intraarterial injection of vehicle on the other. Ten days later, both latissimus dorsi muscles were raised as thoracodorsally based island flaps, with perfusion determined by laser-Doppler fluximetry. The muscles were wrapped around silicone chambers, simulating cardiomyoplasty, and stimulating electrodes were placed around each thoracodorsal nerve. The muscles were then subjected to an experimental protocol to determine muscle contractile function. At the end of the experiment, latissimus dorsi muscle biopsies were obtained for measurement of bFGF expression. The results demonstrated that the administration of 100 microg of bFGF immediately after the vascular delay procedure increases expression of native bFGF. In the distal and middle muscle segments, it also significantly increased muscle perfusion by approximately 20 percent and fatigue resistance by approximately 300 percent. The administration of growth factors may serve as an important adjuvant to surgical procedures using dynamic muscle flap transfers.  相似文献   

18.
Neurovascular free-muscle transfer for facial reanimation was performed as a secondary reconstructive procedure for 45 patients with facial paralysis resulting from ablative surgery in the parotid region. This intervention differs from neurovascular free-muscle transfer for treatment of established facial paralysis resulting from conditions such as congenital dysfunction, unresolved Bell palsy, Hunt syndrome, or intracranial morbidity, with difficulties including selection of recipient vessels and nerves, and requirements for soft-tissue augmentation. This article describes the authors' operative procedure for neurovascular free-muscle transfer after ablative surgery in the parotid region. Gracilis muscle (n = 24) or latissimus dorsi muscle (n = 21) was used for transfer. With gracilis transfer, recipient vessels comprised the superficial temporal vessels in 12 patients and the facial vessels in 12. For latissimus dorsi transfer, recipient vessels comprised the facial vessels in 16 patients and the superior thyroid artery and superior thyroid or internal jugular vein in four. Facial vessels on the contralateral side were used with interpositional graft of radial vessels in the remaining patient with latissimus dorsi transfer. Cross-face nerve grafting was performed before muscle transfer in 22 patients undergoing gracilis transfer. In the remaining two gracilis patients, the ipsilateral facial nerve stump was used as the primary recipient nerve. Dermal fat flap overlying the gracilis muscle was used for cheek augmentation in one patient. In the other 23 patients, only the gracilis muscle was used. With latissimus dorsi transfer, the ipsilateral facial nerve stump was used as the recipient nerve in three patients, and a cross-face nerve graft was selected as the recipient nerve in six. The contralateral facial nerve was selected as the recipient nerve in 12 patients, and a thoracodorsal nerve from the latissimus dorsi muscle segment was crossed through the upper lip to the primary recipient branches. A soft-tissue flap was transferred simultaneously with the latissimus muscle segment in three patients. Contraction of grafted muscle was not observed in two patients with gracilis transfer and in three patients with latissimus dorsi transfer. In one patient with gracilis transfer and one patient with latissimus dorsi transfer, acquired muscle contraction was excessive, resulting in unnatural smile animation. The recipient nerves for both of these patients were the ipsilateral facial nerve stumps, which were dissected by opening the facial nerve canal in the mastoid process. From the standpoint of operative technique, the one-stage transfer for latissimus dorsi muscle appears superior. Namely, a combined soft-tissue flap can provide sufficient augmentation for depression of the parotid region following wide resection. A long vascular stalk of thoracodorsal vessels is also useful for anastomosis, with recipient vessels available after extensive ablation and neck dissection.  相似文献   

19.
Reconstruction of chest wall and axilla are performed in 11 patients using a contralateral latissimus dorsi musculocutaneous flap. The entire lattisimus dorsi muscle, including the fascial portion, safely carried an island of skin from the area of the lumbodorsal fascia to the contralateral axilla. The flap was transposed to the defect through a tunnel between the pectoralis major and minor muscles. Most patients who needed reconstruction of the chest wall and axilla had compromised ipsilateral vasculature that prohibited its use in a pedicled flap but had an intact contralateral chest wall, axilla, and thoracodorsal vessels. Therefore, this procedure was performed easily in comparison with a free flap or pedicled omental flap. This is a new, valuable application for the versatile latissimus dorsi musculocutaneous flap.  相似文献   

20.
Although the mechanism by which vascular delay benefits skin flaps is not completely understood, this topic has been extensively studied and reported on in the literature. In contrast, little has been documented about the effects of vascular delay in skeletal muscle flaps. Recent animal studies tested the effectiveness of vascular delay to enhance latissimus dorsi muscle flap viability for use in cardiomyoplasty and found that it prevented distal flap necrosis. However, these studies did not define the optimal time period necessary to achieve this beneficial effect. The purpose of this study was to determine how many days of "delay" can elicit the beneficial effects of vascular delay on latissimus dorsi muscle flaps. To accomplish this, 90 latissimus dorsi muscles of 45 male Sprague-Dawley rats were randomly subjected to vascular delay on one side or a sham procedure on the other. After predetermined delay periods (0, 3, 7, 10, and 14 days) or a sham procedure, all latissimus dorsi muscles were elevated as single pedicled flaps based only on their thoracodorsal neurovascular pedicle. Latissimus dorsi muscle perfusion was measured using a Laser Doppler Perfusion Imager just before and immediately after flap elevation. The muscles were then returned to their original vascular beds, isolated from adjacent tissue with Silastic film, sutured into place to maintain their original size and shape, and left there for 5 days. After 5 days, the latissimus dorsi muscle flaps were dissected free, scanned again (Laser Doppler Perfusion Imager-perfusion measurements), and the area of distal necrosis was measured using digitized planimetry of magnified images. The authors' results showed that delay periods of 3, 7, 10, and 14 days significantly increased (p < 0.05) blood perfusion and decreased (p < 0.05) distal flap necrosis when compared with sham controls. On the basis of these findings, the authors conclude that in their rat latissimus dorsi muscle flap model the beneficial effects of vascular delay are present as early as 3 days. If these findings also hold true in humans, they could be useful in cardiomyoplasty by allowing surgeons to shorten the amount of time between the vascular delay procedure and the cardiomyoplasty procedure in these very sick patients.  相似文献   