首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis.  相似文献   

2.
The aim of this study is to obtain evidence supporting or negating the hypothesis that muscle pain is associated with sustained activation of low-threshold motor units. Long-term surface electromyographic (EMG) recordings of trapezius activity pattern were related to subjectively reported shoulder and neck pain in work and leisure. Recordings from 118 female subjects (73 recorded both during work and leisure) were analyzed. Computer operators, secretaries, and health care and retail workers were represented in the material. The recordings were calibrated by the root-mean-square-detected response at maximal voluntary contraction (%maximum EMG). The analysis was performed by quantifying duration and amplitude of surface EMG activity exceeding 2% maximum EMG ("EMG bursts"). Three response categories were defined by duration of the burst periods during work: low- (<50%), intermediate- (50-70%), and high-response (>70%) groups. Shoulder and neck pain was assessed by hourly visual analog score throughout work and leisure and by pain score for the last 6 mo. Shoulder and neck pain was higher at work than leisure for subjects with long-term pain in both the high- and the low-response groups. Persistent pain, defined by the 6-mo score, was more prevalent in the high- than the low- and intermediate-response groups (73 vs. 37%); relative risk was 2.0. Trapezius activity was reduced from work to leisure for the high- but not the low-response group. The activity pattern is consistent with low-threshold motor unit overexertion for the high- but not the low-response group. We speculate that different mechanisms of muscle pain causation, dependent and independent of motor activity pattern, coexist.  相似文献   

3.
There is a lack of early biomarkers of intervertebral disc (IVD) degeneration. Thus, the authors developed the analysis of magnetic resonance signal intensity distribution (AMRSID) method to analyse the 3D distribution of the T2-weighted MR signal intensity within the IVD using normalised histograms, weighted centres and volume ratios. The objective was to assess the sensitivity of the AMRSID method to the segmentation process and data normalisation. Repetition of the semi-automatic segmentation by the same operator did not influence the quality of the contour or our new MR distribution parameters whereas the skills of the operator influenced only the MR distribution parameters, and the instructions given prior to the segmentation influenced both the quality of the contour and the MR distribution parameters. Bone normalisation produces an index that jointly highlights IVD and bone health, whereas cerebrospinal fluid normalisation only suppresses the effect of the acquisition gain. This robust AMRSID method has the potential to improve the diagnostic with earlier biomarkers and the prognosis of evolution.  相似文献   

4.
There is a large and growing body of surface electromyography (sEMG) research using laboratory-specific signal processing procedures (i.e., digital filter type and amplitude normalisation protocols) and data analyses methods (i.e., co-contraction algorithms) to acquire practically meaningful information from these data. As a result, the ability to compare sEMG results between studies is, and continues to be challenging. The aim of this study was to determine if digital filter type, amplitude normalisation method, and co-contraction algorithm could influence the practical or clinical interpretation of processed sEMG data. Sixteen elite female athletes were recruited. During data collection, sEMG data was recorded from nine lower limb muscles while completing a series of calibration and clinical movement assessment trials (running and sidestepping). Three analyses were conducted: (1) signal processing with two different digital filter types (Butterworth or critically damped), (2) three amplitude normalisation methods, and (3) three co-contraction ratio algorithms. Results showed the choice of digital filter did not influence the clinical interpretation of sEMG; however, choice of amplitude normalisation method and co-contraction algorithm did influence the clinical interpretation of the running and sidestepping task. Care is recommended when choosing amplitude normalisation method and co-contraction algorithms if researchers/clinicians are interested in comparing sEMG data between studies.  相似文献   

5.
The synucleins are a family of intrinsically disordered proteins involved in various human diseases. alpha-Synuclein has been extensively characterized due to its role in Parkinson's disease where it forms intracellular aggregates, while gamma-synuclein is overexpressed in a majority of late-stage breast cancers. Despite fairly strong sequence similarity between the amyloid-forming regions of alpha- and gamma-synuclein, gamma-synuclein has only a weak propensity to form amyloid fibrils. We hypothesize that the different fibrillation tendencies of alpha- and gamma-synuclein may be related to differences in structural propensities. Here we have measured chemical shifts for gamma-synuclein and compared them to previously published shifts for alpha-synuclein. In order to facilitate direct comparison, we have implemented a simple new technique for re-referencing chemical shifts that we have found to be highly effective for both disordered and folded proteins. In addition, we have developed a new method that combines different chemical shifts into a single residue-specific secondary structure propensity (SSP) score. We observe significant differences between alpha- and gamma-synuclein secondary structure propensities. Most interestingly, gamma-synuclein has an increased alpha-helical propensity in the amyloid-forming region that is critical for alpha-synuclein fibrillation, suggesting that increased structural stability in this region may protect against gamma-synuclein aggregation. This comparison of residue-specific secondary structure propensities between intrinsically disordered homologs highlights the sensitivity of transient structure to sequence changes, which we suggest may have been exploited as an evolutionary mechanism for fast modulation of protein structure and, hence, function.  相似文献   

6.
We, the Guest Editors of this Special Issue of The International Journal of Developmental Biology, are two older embryologists, who are trying to bridge the current chasm between Entwicklungsmechanic, the developmental mechanics of our embryogenesis forefathers, and the modern movement of molecular developmental biology. Our rallying cry is that of Wilhelm His: "To think that heredity will build organic beings without mechanical means is a piece of unscientific mysticism" (His, 1888). Until recently, this claim appeared to us to fall on the somewhat deaf ears of molecular developmental biologists. Yet, the world is still one, and both physics and chemistry obviously have their place in embryogenesis. Indeed, at the molecular level, membrane proteins which are mechanoreceptors and motor molecules may begin to point the way. Here, we and our colleagues will make the case for a more equitable consideration of molecules and mechanics.  相似文献   

7.
Functional genomics (the elucidation of gene function in the context of a sequenced genome) depends critically on functional biology. Genetic model organisms have hitherto not attracted much physiological input, however. This skills mismatch, termed the phenotype gap, can be quantified by analysis of the annotations of sequenced genomes. This is illustrated in the context of Drosophila. In this case, it seems as if a shift from developmental biology to transport physiology and metabolism will be required to provide a more balanced skills base for post-genomics.  相似文献   

8.
FT-IR spectrometry and X-ray diffraction were applied to probe the differences between pulp fibers from Eucalyptus wood (hardwood) and Norway spruce wood (softwood). Wood processing was found to induce certain structural alterations within its components depending on the type of wood and the applied procedure. These differences were established by using techniques such as; spectral comparison of wood samples with those of individual component fractions, derivative spectroscopy, bands deconvolution, etc. FT-IR spectroscopy was shown to be an important tool that provided details about the structural characteristics of hardwood and softwood samples. Using second-derivative spectra and deconvolution processes small differences between spectra became apparent that allowed correlations to be made related to wood composition. In addition a correlation was established between the integral absorptions for the various bands and lignin content as well as the lignin/carbohydrate content. Relations between various spectral characteristics and the degree of crystallinity and sample composition were established.  相似文献   

9.
The first aim was to investigate the impact of different electromyography (EMG) parameters as a reference to normalize the EMG amplitude of the superficial quadriceps femoris muscles across different sets of a knee extension exercise. The second aim is to examine the reliability between days of the EMG parameters used as a reference. Eleven young males attended the laboratory on 4 different days and performed one repetition maximum test, maximumvoluntary isometric contractions, and a resistance training protocol until failure. Surface EMG was placed over the rectus femoris, vastus lateralis, and vastus medialis muscles. Seven EMG parameters were calculated from the tasks and used to normalize EMG amplitude measured during the resistance training protocol. A repeated-measures two-way ANOVA was used (normalized EMG amplitude × set) to compare normalized EMG across sets, while an intraclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to calculate the intra-day reliability of the EMG parameters. The present investigation showed that normalized EMG amplitude of the superficial muscles of the quadriceps measured during a knee extension exercise is influenced by the EMG parameter and depends on the muscle. While rectus femoris and vastus lateralis normalized EMG amplitude presented one parameter among seven showing similar value to the other parameters, VM showed two. Lastly, all EMG parameters for all muscles presented an overall excellent reliability and agreement between days.  相似文献   

10.
11.
This study’s aim was to determine the between days reliability of surface EMG recordings from the superficial quadriceps during a multi joint sub-maximal fatiguing protocol. Three subject groups (healthy n = 29; patellofemoral pain syndrome n = 74; knee osteoarthritis n = 55) performed the task at 60 maximum voluntary isometric contraction on three separate days. Spectral and amplitude EMG parameters were recorded from vastus medialis oblique, vastus lateralis and rectus femoris and were analysed for between days reliability using intraclass correlation coefficient (ICC(2,1)), the standard errors of measure and smallest detectable differences. For frequency results, initial and final frequency values had ‘good’ or ‘excellent’ reliability in all groups for all muscles. ICCs for median frequency slopes for vastus medialis oblique, vastus lateralis, and rectus femoris respectively, in the osteoarthritis group were 0.04, 0.55, and 0.72; in the patellofemoral pain group were 0.41, 0.17, and 0.33; in the healthy group were 0.68, 0.64, and 0.31. The standard errors of measurement and smallest detectable differences for all groups and for all muscles were unacceptably high. For amplitude results, ICC root mean squared initial and final values were ‘good’ to ‘excellent’ for all groups and all muscles, albeit with high measurement error. The ICCs for root mean squared slopes in all tests were ‘poor’ with extremely high measurement error. The poor between days reliability and high measurement error suggests that surface EMG should not be adopted to assess fatigue during multi joint sub-maximal isometric quadriceps testing.  相似文献   

12.
Though surface electromyography (EMG) has been widely used in studies of occupational exposure, its precision in terms of the variance between-days and between-subjects has seldom been evaluated. This study aimed at such an evaluation. Six women performed three different work tasks: 'materials picking', 'light assembly', and 'heavy assembly', repeated on 3 different days. EMG was recorded from m. trapezius, m. infraspinatus and the forearm extensors. Normalisation was made to a maximal (MVE), and a submaximal (RVE), reference contraction. Variance components between days (within subjects) and between subjects were derived for the 10th, 50th and 90th percentiles, as well as for muscular rest parameters. For the task 'heavy assembly', the coefficient of variation between days (CV(BD)) was 8% for m. trapezius (right side, 50th percentile, MVE normalised values). Larger variabilities were found for m. infraspinatus (CV(BD) 15%), and the forearm extensors (CV(BD) 33%). Between-subjects variability (CV(BS)) was greater, 16% for m. trapezius and 57% for m. infraspinatus, 29% for the forearm extensors. RVE normalisation resulted in larger CV(BD), while reducing CV(BS). The between-days and between-subjects variability may be used to optimise sampling strategy, and to assess the bias in epidemiological studies. The bias caused by measurement procedures per se is acceptable.  相似文献   

13.
Although the assembly of the Space Station is not yet complete, now is the time to start on ground the scientific and technical realisations for the maximum return in life sciences. An important prerequisite is that all suitable ground-based techniques and scientifcal and technical infrastructures are available to plan, prepare and perform space experiments.  相似文献   

14.
The purpose of this study was to use an electromyography (EMG) based muscle model to investigate the performance enhancement of stretch-shortening cycle (SSC) tasks at different elbow flexion-extension velocities. A torque motor was used to oscillate the forearms of seven healthy male subjects (23-40 years) during SSC and non-SSC contractions at four frequencies of movement (.58, 1.5, 2.4 and 3.3Hz) over a range of 105 degrees -162 degrees of elbow extension. The torque was integrated as a function of joint angle to yield the work produced by the elbow flexors. The elbow flexors were transcutaneously stimulated with a voltage equivalent to 60% maximum voluntary isometric contraction torque for 4s at 50Hz. EMG of the elbow flexors and extensors was recorded from the biceps and triceps respectively. The processed EMG was used to drive a Hill based model to predict the torque of the elbow flexors. Results indicate that muscle work increases from non-SSC to SSC trials. Work decreases for SSC and non-SSC trials with increasing velocity. The simulated constant activation muscle model predicted work well for all trials and conditions, indicating muscle model accuracy. The EMG driven model predicted well for all non-SSC trials, but significantly underestimated the work for SSC tasks, suggesting that the contractile component is directly involved in optimising muscle work during SSC tasks.  相似文献   

15.
The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC=0.986, %SEM=7.5, %CV=9.2; 60%-MVIC: ICC=0.975, %SEM=10, %CV=13.7) and intramuscular (MVIC: ICC=0.910, %SEM=20, %CV=19.1; 60%-MVIC: ICC=0.952, %SEM=16.5, %CV=13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions.  相似文献   

16.
Paired intercellular transmembrane channels, termed connexons, comprised of hexameric assemblies of gap junction protein, were isolated and purified from rat liver by exploiting their resistance to either Sarkosyl detergent solubilization or alkali extraction. The secondary structures of the gap junction proteins prepared by these methods were compared by circular dichroism (CD) spectroscopy. Both the spectra and the calculated net secondary structures of the proteins obtained by the two isolation methods were different. The protein isolated by the Sarkosyl treatment was found to be approximately 50% alpha-helical, while protein isolated by alkali extraction had a lower helix content (approximately 40%). In both types of preparations, however, the helical content of the gap junction protein was sufficiently large to be consistent with an all-helical model for the membrane-spanning parts of the structure. CD spectroscopy was also used to examine the effects of proteolytic digestion of the cytoplasmic domain on the net secondary structure of the detergent-treated gap junction protein. The membrane-bound fragments had a slightly higher proportion of their residues that were alpha-helical in nature, suggesting that the transmembrane and/or intra-gap domains are indeed enriched in this type of secondary structure. This information constrains the range of models which can be realistically proposed for the channel structure.  相似文献   

17.
The present study aimed at exploring the statistical power of ergonomic intervention studies using electromyography (EMG) from the upper trapezius muscle. Data from a previous study of cyclic assembly work were reanalyzed with respect to exposure variability between subjects, between days, and within days. On basis of this information, the precision and power of different data collection strategies were explored. A sampling strategy comprising four registrations of about two min each (i.e. two work cycles) for one day per subject resulted in coefficients of variation between subjects on the 10-, 50-, and 90-APDF-percentiles of 0.44, 0.31, and 0.29, respectively. The corresponding necessary numbers of subjects in a study aiming at detecting a 20% exposure difference between two independent groups of equal size were 154, 78, and 68, respectively (p< or = 0.05, power 0.80). Multiple measurement days per subject would improve power, but only to a marginal extent beyond 4 days of recording. Increasing the number of recordings per day would have minor effects. Bootstrap resampling of the data set revealed that estimates of variability and power were associated with considerable uncertainty. The present results in combination with an overview of other occupational studies showed that common-size investigations using trapezius EMG percentiles are at great risk of suffering from insufficient statistical power, even if the expected intervention effect is substantial. The paper suggests a procedure of how to retrieve and use exposure variability information as an aid when studies are planned, and how to allocate measurements efficiently.  相似文献   

18.
Using a four-taxon example under a simple model of evolution, we show that the methods of maximum likelihood and maximum posterior probability (which is a Bayesian method of inference) may not arrive at the same optimal tree topology. Some patterns that are separately uninformative under the maximum likelihood method are separately informative under the Bayesian method. We also show that this difference has impact on the bootstrap frequencies and the posterior probabilities of topologies, which therefore are not necessarily approximately equal. Efron et al. (Proc. Natl. Acad. Sci. USA 93:13429-13434, 1996) stated that bootstrap frequencies can, under certain circumstances, be interpreted as posterior probabilities. This is true only if one includes a non-informative prior distribution of the possible data patterns, and most often the prior distributions are instead specified in terms of topology and branch lengths. [Bayesian inference; maximum likelihood method; Phylogeny; support.].  相似文献   

19.
X Hu  G Dahl 《FEBS letters》1999,451(2):113-117
Gap junction channels span the membranes of two adjacent cells and allow the gated transit of molecules as large as second messengers from cell to cell. The structure of the gap junction channel pore is not resolved. For identification of pore determinants we used a chimera of two connexins, cx46 and cx32E(1)43, that form membrane channels with distinct unit conductances and channel kinetics. Exchange of the first transmembrane segment (M1) between these connexins resulted in a chimera that exhibited most of the channel properties of the M1 donor, including single channel conductance, channel kinetics, and the preference to dwell at a subconductance level. The M1 segment thus appears to be an important determinant of conductance and gating properties of connexin channels.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号