首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly sensitive and specific assay method was developed for the detection of viable Escherichia coli as an indicator organism in water, using nucleic acid sequence-based amplification (NASBA) and electrochemiluminescence (ECL) analysis. Viable E. coli were identified via a 200-nt-long target sequence from mRNA (clpB) coding for a heat shock protein. In the detection assay, a heat shock was applied to the cells prior to disruption to induce the synthesis of clpB mRNA and the mRNA was extracted, purified, and finally amplified using NASBA. The amplified mRNA was quantified with an ECL detection system after hybridization with specific DNA probes. Several disruption methods were investigated to maximize total RNA extracted from viable cells. Optimization was also carried out regarding the design of NASBA primer pairs and detection probes, as well as reaction and detection conditions. Finally, the assay was tested regarding sensitivity and specificity. Analysis of samples revealed that as few as 40 E. coli cells/mL can be detected, with no false positive signals resulting from other microorganisms or nonviable E. coli cells. Also, it was shown that a quantification of E. coli cells was possible with our assay method.  相似文献   

2.
A circulating-flow piezoelectric biosensor, based on an Au nanoparticle amplification and verification method, was used for real-time detection of a foodborne pathogen, Escherichia coli O157:H7. A synthesized thiolated probe (Probe 1; 30-mer) specific to E. coli O157:H7 eaeA gene was immobilized onto the piezoelectric biosensor surface. Hybridization was induced by exposing the immobilized probe to the E. coli O157:H7 eaeA gene fragment (104-bp) amplified by PCR, resulting in a mass change and a consequent frequency shift of the piezoelectric biosensor. A second thiolated probe (Probe 2), complementary to the target sequence, was conjugated to the Au nanoparticles and used as a "mass enhancer" and "sequence verifier" to amplify the frequency change of the piezoelectric biosensor. The PCR products amplified from concentrations of 1.2 x 10(2) CFU/ml of E. coli O157:H7 were detectable by the piezoelectric biosensor. A linear correlation was found when the E. coli O157:H7 detected from 10(2) to 10(6) CFU/ml. The piezoelectric biosensor was able to detect targets from real food samples.  相似文献   

3.
sigma 32, the product of the Escherichia coli rpoH locus, is an alternative RNA polymerase sigma factor utilized to express heat shock genes upon a sudden rise in temperature. E. coli K165 [rpoH165(Am) supC(Ts)] is temperature sensitive for growth and does not induce heat shock protein synthesis. We have isolated a locus from Rhizobium meliloti called suhR that allows E. coli K165 to grow at high temperature and induce heat shock protein synthesis. R. meliloti suhR mutants were viable and symbiotically effective. suhR was found to have no DNA or derived amino acid sequence similarity to the genes of previously sequenced sigma factors or other data base entries, although a helix-turn-helix DNA-binding protein motif is present. suhR did not restore the phenotypic defects of delta rpoH E. coli; suppression of the E. coli K165 phenotype is thus likely to involve E. coli sigma 32. Western immunoblots showed that suhR caused an approximately twofold elevation of sigma 32 levels in K165; RNA blots indicated that rpoH mRNA level and stability were not altered. Stabilization of sigma 32 protein and increased rpoH mRNA translation are thus the most probable mechanisms of suppression.  相似文献   

4.
5.
6.
7.
Geng P  Zhang X  Teng Y  Fu Y  Xu L  Xu M  Jin L  Zhang W 《Biosensors & bioelectronics》2011,26(7):3325-3330
A new type of DNA sequence-specific electrochemical biosensor based on magnetic beads for the detection of Escherichia coli is reported in the present work. Alginic acid-coated cobalt magnetic beads, capped with 5'-(NH(2)) oligonucleotide and employed not only for magnetic separation but also as the solid adsorbent, were used as DNA probes to hybridize with the target E. coli DNA sequence. This assay was specific for E. coli detection depending on the uid A gene, which encodes for the enzyme β-d-glucuronidase produced by E. coli strains. When daunomycin (DNR) was used as DNA hybridization indicator, the target sequences of E. coli hybridized with the probes resulted in the decrease of DNR reduction peak current, which was proportional to the E. coli concentration. The optimization of the hybridization detection was carried out and the specificity of the probes was also demonstrated. This DNA biosensor can be employed to detect a complementary target sequence for 3.0×10(-10) mol/L and denatured PCR products for 0.5 ng/μL. The linear range of the developed biosensor for the detection of E. coli cells was from 1.0×10(2) to 2.0×10(3) cells/mL with a detection limit of 50 cells/mL. After a brief enrichment process, a concentration of 10 cells/mL E. coli in real water samples was detected by the electrochemical biosensor.  相似文献   

8.
Peptide Nucleic Acids (PNA) is a new type of DNA analogue with a peptide backbone. We developed a rapid identification system of Escherichia. coli O157:H7 using PNA mediated PCR clamping. Firstly, we confirmed a single nucleotide alteration in the uidA gene (T93G), which is specific to E. coli O157: H7. We designed forward mutant DNA primer, wild type PNA, and a reverse DNA primer corresponding to the uidA sequence. PCR cycle consisted of four steps including dual annealing temperatures, 57 degrees C and 45 degrees C. Among 20 E. coli strains with various serotypes and 4 neighboring strains, the amplified bands (517 bp) were detected only in E. coli O157:H7 strains. PNA has specifically inhibited the PCR amplification from a wild type uidA gene. We successfully developed a multiplex PCR system, which detects both shigatoxin (stx) and uidA genes at once, to get reliable results by easier and rapid operation. We also analyzed kinetic parameters of PNA/DNA association using surface plasmon resonance and melting temperature using fluorescence resonance energy transfer (FRET). We discussed a selection mechanism of PCR clamping from these results.  相似文献   

9.
10.
目的实现对致病性大肠埃希菌(E.coli)、沙门菌(Salmonella)的同时检测,建立快速灵敏的双重PCR检测方法。方法以致病性大肠埃希菌和沙门菌毒力岛基因为研究对象,根据GenBank发表的大肠埃希菌和沙门菌毒力岛基因序列,分别设计合成了大肠埃希菌毒力岛irpl、irl)2和fyuA,沙门菌毒力岛mgtC、sseL和sopB等6对引物,以禽致病性大肠埃希菌(CVCC1565)菌株和沙门菌(ATCC9150)菌株的核酸混合物为模板,经引物特异性试验,引物组合,成功建立了快速鉴别检测致病性大肠埃希菌和沙门菌的双重PCR方法。结果特异性试验结果显示,引物irpl、irp2和fyuA仅能扩增出大肠埃希菌(CVCC1565)的特异性片段,大小分别是799、414和948bp;引物mgtC、sseL和sopB仅能扩增出沙门菌(ATCC9150)的特异性片段,大小分别是500、269和1000bp。敏感性试验结果表明大肠埃希菌和沙门菌的最低检测限分别为2.2×101CFU/mL和2.0×101CFU/mL。结论本研究建立的双重PCR方法具有特异性强、敏感性高、快速简便等特点,可用于致病性大肠埃希菌和沙门菌的联合检测与鉴别诊断。  相似文献   

11.
Escherichia coli O157:H7, the most common serotype of enterohemorrhagic E. coli (EHEC), is responsible for numerous food-borne and water-borne infections worldwide. An integrating waveguide biosensor is described for the detection of water-borne E. coli O157, based on a fluorescent sandwich immunoassay performed inside a glass capillary waveguide. The genomic DNA of captured E. coli O157 cells was extracted and quantitative real-time PCR subsequently performed to assess biosensor-capture efficiency. In vitro microbial growth in capillary waveguide is also documented. The biosensor allows for quantitative detection of as few as 10 cells per capillary (0.075 ml volume) and can be used in conjunction with cell amplification, PCR and microarray technologies to positively identify a pathogen.  相似文献   

12.
Ultrasensitive molecular beacon (MB) DNA biosensors, with micrometer to submicrometer sizes, have been developed for DNA/RNA analysis. The fluorescence-based biosensors have been applied in DNA/ RNA detection without the need for a dye-labeled target molecule or an intercalation reagent in the testing solution. Molecular beacons are hairpin-shaped oligonucleotides that report the presence of specific nucleic acids. We have designed a surface-immobilizable biotinylated ssDNA molecular beacon for DNA hybridization at a liquid-solid interface. The MBs have been immobilized onto ultrasmall optical fiber probes through avidin-biotin binding. The MB DNA biosensor has been used directly to detect, in real time, its target DNA molecules without the need for a competitive assay. The biosensor is stable and reproducible. The MB DNA biosensor has selectivity with single base-pair mismatch identification capability. The concentration detection limits and mass detection limits are 0.3 nM and 15 amol for a 105-microm biosensor, and 10 nM and 0.27 amol for a submicrometer biosensor, respectively. We have also prepared molecular beacon DNA biosensor arrays for simultaneous analysis of multiple DNA sequences in the same solution. The newly developed DNA biosensors have been used for the precise quantification of a specific rat gamma-actin mRNA sequence amplified by the polymerase chain reaction.  相似文献   

13.
14.
An electronic platform to detect very small amounts of genomic DNA from bacteria without the need for PCR amplification and molecular labeling is described. The system uses carbon nanotube field-effect transistor (FET) arrays whose electrical properties are affected by minute electrical charges localized on their active regions. Two pathogenic strains of E. coli are used to evaluate the detection properties of the transistor arrays. Described herein are the results for detection of synthetic oligomers, unpurified and highly purified genomic DNA at various concentrations and their comparison against non-specific binding. In particular, the capture of genomic DNA of E. coli O157:H7 by a specific oligonucleotide probe coated onto the transistor array results in a significant shift in the threshold (gate-source) voltage (V(th)). By contrast the signal under the same procedure using a different strain, E. coli O45 that is non-complementary to the probe remained nearly constant. This work highlights the detection sensitivity and efficacy of this biosensor without stringent requirement for DNA sample preparation.  相似文献   

15.
The half lives of mRNA for Escherichia coli chloramphenicol-acetyltransferase, Bacillus amyloliquefaciens alpha-amylase and human leucocyte interferon were measured in E. coli cells by molecular RNA.DNA hybridization. The effect of mutation in pnp gene, coding polynucleotide phosphorylase, on the stability of these mRNA was studied. The half life of interferon mRNA increases from 25 to 90 s in the pnp mutant, resulting in an increase of interferon accumulation. The stability of interferon in E. coli cells depends on the htpR gene, controlling the heat shock response. The yields of leucocyte interferons alpha-2, alpha I-1 and fibroblast interferon beta increase ten times in htpR mutants. Thus, by using pnp and htpR mutants it is possible to enhance considerably the eukaryotic gene expression in bacterial cells.  相似文献   

16.
17.
Heat shock response of murine Chlamydia trachomatis.   总被引:18,自引:4,他引:14       下载免费PDF全文
  相似文献   

18.
The lon gene of Escherichia coli encodes the ATP-dependent serine protease La and belongs to the family of sigma 32-dependent heat shock genes. In this paper, we report the cloning and characterization of the lon gene from the gram-positive bacterium Bacillus subtilis. The nucleotide sequence of the lon locus, which is localized upstream of the hemAXCDBL operon, was determined. The lon gene codes for an 87-kDa protein consisting of 774 amino acid residues. A comparison of the deduced amino acid sequence with previously described lon gene products from E. coli, Bacillus brevis, and Myxococcus xanthus revealed strong homologies among all known bacterial Lon proteins. Like the E. coli lon gene, the B. subtilis lon gene is induced by heat shock. Furthermore, the amount of lon-specific mRNA is increased after salt, ethanol, and oxidative stress as well as after treatment with puromycin. The potential promoter region does not show similarities to promoters recognized by sigma 32 of E. coli but contains sequences which resemble promoters recognized by the vegetative RNA polymerase E sigma A of B. subtilis. A second gene designated orfX is suggested to be transcribed together with lon and encodes a protein with 195 amino acid residues and a calculated molecular weight of 22,000.  相似文献   

19.
We developed a software program for the rapid selection of detection probes to be used in nucleic acid-based assays. In comparison to commercially available software packages, our program allows the addition of oligotags as required by nucleic acid sequence-based amplification (NASBA) as well as automatic BLAST searches for all probe/primer pairs. We then demonstrated the usefulness of the program by designing a novel lateral flow biosensor for Streptococcus pyogenes that does not rely on amplification methods such as the polymerase chain reaction (PCR) or NASBA to obtain low limits of detection, but instead uses multiple reporter and capture probes per target sequence and an instantaneous amplification via dye-encapsulating liposomes. These assays will decrease the detection time to just a 20 min hybridization reaction and avoid costly enzymatic gene amplification reactions. The lateral flow assay was developed quantifying the 16S rRNA from S. pyogenes by designing reporter and capture probes that specifically hybridize with the RNA and form a sandwich. DNA reporter probes were tagged with dye-encapsulating liposomes, biotinylated DNA oligonucleotides were used as capture probes. From the initial number of capture and reporter probes chosen, a combination of two capture and three reporter probes were found to provide optimal signal generation and significant enhancement over single capture/reporter probe combinations. The selectivity of the biosensor was proven by analyzing organisms closely related to S. pyogenes, such as other Streptococcus and Enterococcus species. All probes had been selected by the software program within minutes and no iterative optimization and re-design of the oligonucleotides was required which enabled a very rapid biosensor prototyping. While the sensitivity obtained with the biosensor was only 135 ng, future experiments will decrease this significantly by the addition of more reporter and capture probes for either the same rRNA or a different nucleic acid target molecule. This will lead to the possibility of detecting S. pyogenes with a rugged assay that does not require a cell culturing or gene amplification step and will therefore enable rapid, specific and sensitive onsite testing.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号