首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 441 毫秒
1.
The field of proteomics is rapidly turning towards targeted mass spectrometry (MS) methods to quantify putative markers or known proteins of biological interest. Historically, the enzyme-linked immunosorbent assay (ELISA) has been used for targeted protein analysis, but, unfortunately, it is limited by the excessive time required for antibody preparation, as well as concerns over selectivity. Despite the ability of proteomics to deliver increasingly quantitative measurements, owing to limited sensitivity, the leads generated are in the microgram per milliliter range. This stands in stark contrast to ELISA, which is capable of quantifying proteins at low picogram per milliliter levels. To bridge this gap, targeted liquid chromatography (LC) tandem MS (MS/MS) analysis of tryptic peptide surrogates using selected reaction monitoring detection has emerged as a viable option for rapid quantification of target proteins. The precision of this approach has been enhanced by the use of stable isotope-labeled peptide internal standards to compensate for variation in recovery and the influence of differential matrix effects. Unfortunately, the complexity of proteinaceous matrices, such as plasma, limits the usefulness of this approach to quantification in the mid-nanogram per milliliter range (medium-abundance proteins). This article reviews the current status of LC/MS/MS using selected reaction monitoring for protein quantification, and specifically considers the use of a single antibody to achieve superior enrichment of either the protein target or the released tryptic peptide. Examples of immunoaffinity-assisted LC/MS/MS are reviewed that demonstrate quantitative analysis of low-abundance proteins (subnanogram per milliliter range). A strategy based on this technology is proposed for the expedited evaluation of novel protein biomarkers, which relies on the synergy created from the complementary nature of MS and ELISA.  相似文献   

2.
The main goal of many proteomics experiments is an accurate and rapid quantification and identification of regulated proteins in complex biological samples. The bottleneck in quantitative proteomics remains the availability of efficient software to evaluate and quantify the tremendous amount of mass spectral data acquired during a proteomics project. A new software suite, ICPLQuant, has been developed to accurately quantify isotope‐coded protein label (ICPL)‐labeled peptides on the MS level during LC‐MALDI and peptide mass fingerprint experiments. The tool is able to generate a list of differentially regulated peptide precursors for subsequent MS/MS experiments, minimizing time‐consuming acquisition and interpretation of MS/MS data. ICPLQuant is based on two independent units. Unit 1 performs ICPL multiplex detection and quantification and proposes peptides to be identified by MS/MS. Unit 2 combines MASCOT MS/MS protein identification with the quantitative data and produces a protein/peptide list with all the relevant information accessible for further data mining. The accuracy of quantification, selection of peptides for MS/MS‐identification and the automated output of a protein list of regulated proteins are demonstrated by the comparative analysis of four different mixtures of three proteins (Ovalbumin, Horseradish Peroxidase and Rabbit Albumin) spiked into the complex protein background of the DGPF Proteome Marker.  相似文献   

3.
Mass spectrometry (MS) -based proteomics has become an indispensable tool with broad applications in systems biology and biomedical research. With recent advances in liquid chromatography (LC) and MS instrumentation, LC–MS is making increasingly significant contributions to clinical applications, especially in the area of cancer biomarker discovery and verification. To overcome challenges associated with analyses of clinical samples (for example, a wide dynamic range of protein concentrations in bodily fluids and the need to perform high throughput and accurate quantification of candidate biomarker proteins), significant efforts have been devoted to improve the overall performance of LC–MS-based clinical proteomics platforms. Reviewed here are the recent advances in LC–MS and its applications in cancer biomarker discovery and quantification, along with the potentials, limitations and future perspectives.  相似文献   

4.
An important component of proteomic research is the high-throughput discovery of novel proteins and protein–protein interactions that control molecular events that contribute to critical cellular functions and human disease. The interactions of proteins are essential for cellular functions. Identifying perturbation of normal cellular protein interactions is vital for understanding the disease process and intervening to control the disease. A second area of proteomics research is the discovery of proteins that will serve as biomarkers for the early detection, diagnosis and drug treatment response for specific diseases. These studies have been referred to as clinical proteomics. To discover biomarkers, proteomics research employs the quantitative comparison of peptide and protein expression in body fluids and tissues from diseased individuals (case) versus normal individuals (control). Methods that couple 2D capillary liquid chromatography (LC) and tandem mass spectrometry (MS/MS) analysis have greatly facilitated this discovery science. Coupling 2D-LC/MS/MS analysis with automated genome-assisted spectra interpretation allows a direct, high-throughput and high-sensitivity identification of thousands of individual proteins from complex biological samples. The systematic comparison of experimental conditions and controls allows protein function or disease states to be modeled. This review discusses the different purification and quantification strategies that have been developed and used in combination with 2D-LC/MS/MS and computational analysis to examine regulatory protein networks and clinical samples.  相似文献   

5.
Beyond specific applications, such as the relative or absolute quantification of peptides in targeted proteomic experiments, synthetic spike‐in peptides are not yet systematically used as internal standards in bottom‐up proteomics. A number of retention time standards have been reported that enable chromatographic aligning of multiple LC–MS/MS experiments. However, only few peptides are typically included in such sets limiting the analytical parameters that can be monitored. Here, we describe PROCAL (ProteomeTools Calibration Standard), a set of 40 synthetic peptides that span the entire hydrophobicity range of tryptic digests, enabling not only accurate determination of retention time indices but also monitoring of chromatographic separation performance over time. The fragmentation characteristics of the peptides can also be used to calibrate and compare collision energies between mass spectrometers. The sequences of all selected peptides do not occur in any natural protein, thus eliminating the need for stable isotope labeling. We anticipate that this set of peptides will be useful for multiple purposes in individual laboratories but also aiding the transfer of data acquisition and analysis methods between laboratories, notably the use of spectral libraries.  相似文献   

6.
Although significant progress has been made in protein quantification using mass spectrometry during recent years, absolute protein quantification in complex biological systems remains a challenging task in proteomics. The use of stable isotope-labeled standard peptide is the most commonly used strategy for absolute quantification, but it might not be suitable in all instances. Here we report an alternative strategy that employs a stable isotope-labeled intact protein as an internal standard to absolutely quantify the alcohol dehydrogenase (ADH) expression level in a human liver sample. In combination with a new targeted proteomics approach employing the method of multiple reaction monitoring (MRM), we precisely and quantitatively measured the absolute protein expression level of an ADH isoenzyme, ADH1C1, in human liver. Isotope-labeled protein standards are predicted to be particularly useful for measurement of highly homologous isoenzymes such as ADHs where multiple signature peptides can be examined by MRM in a single experiment.  相似文献   

7.
A completely automated peptide mapping liquid chromatography/mass spectrometry (LC/MS) system for characterization of therapeutic proteins in which a common high-performance liquid chromatography (HPLC) autosampler is used for automated sample preparation, including protein denaturation, reduction, alkylation, and enzymatic digestion, is described. The digested protein samples are then automatically subjected to LC/MS analysis using the same HPLC system. The system was used for peptide mapping of monoclonal antibodies (mAbs), known as a challenging group of therapeutic proteins for achieving complete coverage and quantitative representation of all peptides. Detailed sample preparation protocols, using an Agilent HPLC system, are described for Lys-C digestion of mAbs with intact disulfide bonds and tryptic digestion of mAbs after reduction and alkylation. The automated procedure of Lys-C digestion of nonreduced antibody, followed by postdigestion disulfide reduction, produces both the nonreduced and reduced digests that facilitate disulfide linkage analysis. The automated peptide mapping LC/MS system has great utility in preparing and analyzing multiple samples for protein characterization, identification, and quantification of posttranslational modifications during process and formulation development as well as for protein identity and quality control.  相似文献   

8.
Simultaneous quantification of multiple proteins by selected reaction monitoring (SRM) has several applications in cell signaling studies including embryo proteomics. However, concerns have recently been raised over the specificity of SRM assays due to possible ion redundancy and/or sequence similarity of selected peptide with multiple non‐related proteins. In this Viewpoint article, we discuss some simple measures that can increase our confidence in the accuracy of SRM scans used in proteomic experiments. At least in embryonic samples from porcine species, these measures were found to be useful in validating MS‐identified differentially expressed proteins. Among the nine proteins analyzed by SRM assay, all the proteins that were found to be up‐ or down‐regulated in MS experiment were also faithfully up‐ or down‐regulated in SRM assay.  相似文献   

9.
10.
A novel type of isobaric internal peptide standard for quantitative proteomics is described. The standard is a synthetic peptide derived from the target peptide by positional permutation of two amino acids. This type of internal standard is denominated minimally permutated peptide analog (MIPA). MIPA can be differentiated from their target analytes by LC‐MS due to individual retention times and/or by MS/MS due to specific fragment ions. Both quantification methods are demonstrated using peptide mixtures of low and high complexity.  相似文献   

11.
Selected reaction monitoring (SRM) is an accurate quantitative technique, typically used for small-molecule mass spectrometry (MS). SRM has emerged as an important technique for targeted and hypothesis-driven proteomic research, and is becoming the reference method for protein quantification in complex biological samples. SRM offers high selectivity, a lower limit of detection and improved reproducibility, compared to conventional shot-gun-based tandem MS (LC-MS/MS) methods. Unlike LC-MS/MS, which requires computationally intensive informatic postanalysis, SRM requires preacquisition bioinformatic analysis to determine proteotypic peptides and optimal transitions to uniquely identify and to accurately quantitate proteins of interest. Extensive arrays of bioinformatics software tools, both web-based and stand-alone, have been published to assist researchers to determine optimal peptides and transition sets. The transitions are oftentimes selected based on preferred precursor charge state, peptide molecular weight, hydrophobicity, fragmentation pattern at a given collision energy (CE), and instrumentation chosen. Validation of the selected transitions for each peptide is critical since peptide performance varies depending on the mass spectrometer used. In this review, we provide an overview of open source and commercial bioinformatic tools for analyzing LC-MS data acquired by SRM.  相似文献   

12.
Targeted proteomics has gained significant popularity in mass spectrometry‐based protein quantification as a method to detect proteins of interest with high sensitivity, quantitative accuracy and reproducibility. However, with the emergence of a wide variety of targeted proteomics methods, some of them with high‐throughput capabilities, it is easy to overlook the essence of each method and to determine what makes each of them a targeted proteomics method. In this viewpoint, we revisit the main targeted proteomics methods and classify them in four categories differentiating those methods that perform targeted data acquisition from targeted data analysis, and those methods that are based on peptide ion data (MS1 targeted methods) from those that rely on the peptide fragments (MS2 targeted methods).  相似文献   

13.
基于三重四极杆质谱仪的选择反应监测(SRM)技术是一种根据已有信息或理论信息靶向进行质谱信号采集的技术,具有高选择性、高重复性、高灵敏度、宽动态范围等特点,已被广泛应用于蛋白质组学研究,用于生物样本中蛋白质的绝对定量分析.本文对SRM技术的特点、发展过程、在蛋白质组学中的应用现状以及发展前景进行了概述.  相似文献   

14.
The plasma proteome has a wide dynamic range of protein concentrations and is dominated by a few highly abundant proteins. Discovery of novel cancer biomarkers using proteomics is particularly challenging because specific biomarkers are expected to be low abundance proteins with normal blood concentrations of low nanograms per milliliter or less. Conventional, one- and two-dimensional proteomic methods including 2D PAGE, 2D DIGE, LC-MS/MS, and LC/LC-MS/MS do not have the capacity to consistently detect many proteins in this range. In contrast, new higher dimensional (Hi-D) separation strategies, utilizing more than two dimensions of fractionation, can profile the low abundance proteome.  相似文献   

15.
Biomarker discovery produces lists of candidate markers whose presence and level must be subsequently verified in serum or plasma. Verification represents a paradigm shift from unbiased discovery approaches to targeted, hypothesis-driven methods and relies upon specific, quantitative assays optimized for the selective detection of target proteins. Many protein biomarkers of clinical currency are present at or below the nanogram/milliliter range in plasma and have been inaccessible to date by MS-based methods. Using multiple reaction monitoring coupled with stable isotope dilution mass spectrometry, we describe here the development of quantitative, multiplexed assays for six proteins in plasma that achieve limits of quantitation in the 1-10 ng/ml range with percent coefficients of variation from 3 to 15% without immunoaffinity enrichment of either proteins or peptides. Sample processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate biomarker proteins were developed and optimized by addition of exogenous proteins to immunoaffinity depleted plasma from a healthy donor. Quantitative multiple reaction monitoring assays were designed and optimized for signature peptides derived from the test proteins. Based upon calibration curves using known concentrations of spiked protein in plasma, we determined that each target protein had at least one signature peptide with a limit of quantitation in the 1-10 ng/ml range and linearity typically over 2 orders of magnitude in the measurement range of interest. Limits of detection were frequently in the high picogram/milliliter range. These levels of assay performance represent up to a 1000-fold improvement compared with direct analysis of proteins in plasma by MS and were achieved by simple, robust sample processing involving abundant protein depletion and minimal fractionation by strong cation exchange chromatography at the peptide level prior to LC-multiple reaction monitoring/MS. The methods presented here provide a solid basis for developing quantitative MS-based assays of low level proteins in blood.  相似文献   

16.
Systems biology relies on data sets in which the same group of proteins is consistently identified and precisely quantified across multiple samples, a requirement that is only partially achieved by current proteomics approaches. Selected reaction monitoring (SRM)—also called multiple reaction monitoring—is emerging as a technology that ideally complements the discovery capabilities of shotgun strategies by its unique potential for reliable quantification of analytes of low abundance in complex mixtures. In an SRM experiment, a predefined precursor ion and one of its fragments are selected by the two mass filters of a triple quadrupole instrument and monitored over time for precise quantification. A series of transitions (precursor/fragment ion pairs) in combination with the retention time of the targeted peptide can constitute a definitive assay. Typically, a large number of peptides are quantified during a single LC‐MS experiment. This tutorial explains the application of SRM for quantitative proteomics, including the selection of proteotypic peptides and the optimization and validation of transitions. Furthermore, normalization and various factors affecting sensitivity and accuracy are discussed.  相似文献   

17.
Precise and accurate protein quantification is critical to many areas of proteomics. Antibody‐based approaches are costly and time‐consuming to develop, consequently, there is considerable interest in alternative quantitative methods that are versatile and can be implemented without the considerable delays associated with antibody development and characterization. Approaches based on MS have therefore attracted considerable attention and are now frequently touted as the most practical and powerful of all options. Nevertheless, there are serious limitations associated with quantifying a protein based on tandem mass analysis of one or two peptides generated by either chemical or enzymatic cleavage. In an accompanying Viewpoint article, Molloy and coworkers point out that selectivity is not necessarily guaranteed despite the power of SRM. Here we address an additional concern that can also compromise specificity. In complex mammalian systems, multiple proteins can serve as precursors of a single peptide and consequently, depending on the peptide(s) selected, protein levels may be significantly under‐ or overestimated.  相似文献   

18.
随着蛋白质组学研究的不断深入,基于质谱的选择反应监测技术(SRM)已经成为以发现生物标志物为代表的定向蛋白质组学研究的重要手段.SRM技术根据假设信息,特异性地获取符合假设条件的质谱信号,去除不符合条件的离子信号干扰,从而得到特定蛋白质的定量信息.SRM技术具有更高的灵敏度和精确性、更大的动态范围等优势.该技术可分为实验设计、数据获取和数据分析三个步骤.在这几个步骤中,最重要的是利用生物信息学手段总结当前实验数据的结果,并用机器学习方法和总结的经验规则进行SRM实验的母离子和子离子对的预测.针对数据质控和定量的生物信息学方法研究在提高SRM数据可靠性方面具有重要作用.此外,为方便SRM的研究,本文还收集、汇总了SRM技术相关的软件、工具和数据库资源.随着质谱仪器的不断发展,新的SRM实验策略以及分析方法、计算工具也应运而生.结合更优化的实验策略、方法,采用更精准的生物信息学算法和工具,SRM在未来蛋白质组学的发展中将发挥更加重要的作用.  相似文献   

19.
A widely used method for protein identification couples prefractionation of protein samples by one-dimensional (1D) PAGE with LC/MS/MS. We developed a new label-free quantitative algorithm by combining measurements of spectral counting, ion intensity, and peak area on 1D PAGE-based proteomics. This algorithm has several improvements over other label-free quantitative algorithms: (i) Errors in peak detection are reduced because the retention time is based on each LC/MS/MS run and actual precursor m/z. (ii) Detection sensitivity is increased because protein quantification is based on the combination of peptide count, ion intensity, and peak area. (iii) Peak intensity and peak area are calculated in each LC/MS/MS run for all slices from 1D PAGE for every single identified protein and visualized as a Western blot image. The sensitivity and accuracy of this algorithm were demonstrated by using standard curves (17.4 fmol to 8.7 pmol), complex protein mixtures (30 fmol to 1.16 pmol) of known composition, and spiked protein (34.8 fmol to 17.4 pmol) in complex proteins. We studied the feasibility of this approach using the secretome of angiotensin II (Ang II)-stimulated vascular smooth muscle cells (VSMCs). From the VSMC-conditioned medium, 629 proteins were identified including 212 putative secreted proteins. 26 proteins were differently expressed in control and Ang II-stimulated VSMCs, including 18 proteins not previously reported. Proteins related to cell growth (CYR61, protein NOV, and clusterin) were increased, whereas growth arrest-specific 6 (GAS6) and growth/differentiation factor 6 were decreased by Ang II stimulation. Ang II-stimulated changes of plasminogen activator inhibitor-1, GAS6, cathepsin B, and periostin were validated by Western blot. In conclusion, a novel label-free quantitative analysis of 1D PAGE-LC/MS/MS-based proteomics has been successfully applied to the identification of new potential mediators of Ang II action and may provide an alternative to traditional protein staining methods.  相似文献   

20.
Classical proteomics combined two-dimensional gel electrophoresis (2-DE) for the separation and quantification of proteins in a complex mixture with mass spectrometric identification of selected proteins. More recently, the combination of liquid chromatography (LC), stable isotope tagging, and tandem mass spectrometry (MS/MS) has emerged as an alternative quantitative proteomics technology. We have analyzed the proteome of Mycobacterium tuberculosis, a major human pathogen comprising about 4,000 genes, by (i) 2-DE and mass spectrometry (MS) and by (ii) the isotope-coded affinity tag (ICAT) reagent method and MS/MS. The data obtained by either technology were compared with respect to their selectivity for certain protein types and classes and with respect to the accuracy of quantification. Initial datasets of 60,000 peptide MS/MS spectra and 1,800 spots for the ICAT-LC/MS and 2-DE/MS methods, respectively, were reduced to 280 and 108 conclusively identified and quantified proteins, respectively. ICAT-LC/MS showed a clear bias for high M(r) proteins and was complemented by the 2-DE/MS method, which showed a preference for low M(r) proteins and also identified cysteine-free proteins that were transparent to the ICAT-LC/MS method. Relative quantification between two strains of the M. tuberculosis complex also revealed that the two technologies provide complementary quantitative information; whereas the ICAT-LC/MS method quantifies the sum of the protein species of one gene product, the 2-DE/MS method quantifies at the level of resolved protein species, including post-translationally modified and processed polypeptides. Our data indicate that different proteomic technologies applied to the same sample provide complementary types of information that contribute to a more complete understanding of the biological system studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号