首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC–MS/MS method in 17–19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC–MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.  相似文献   

2.
A reversed phase HPLC-MS/MS method has been developed and validated for the quantitative bioanalysis of acetaminophen in dried blood spots (DBS) prepared from small volumes (15 microL) of dog blood. Samples were extracted for analysis with methanol. Detection was by positive ion TurboIonSpray ionisation combined with selected reaction monitoring MS. The analytical concentration range was 0.1-50 microg/mL. The intra-day precision and bias values were both less than 15%. Acetaminophen was stable in DBS stored at room temperature for at least 10 days. The methodology was applied in a toxicokinetic (TK) study where the data obtained from DBS samples was physiologically comparable with results from duplicate blood samples (diluted 1:1 (v/v) with water) analysed using identical HPLC-MS/MS conditions. This work demonstrates that quantitative analysis of a drug extracted from DBS can provide high quality TK data while minimising the volume of blood withdrawn from experimental animals, to an order of magnitude lower than is current practice in the pharmaceutical industry. This is the first reported application of DBS analysis to a TK study in support of a safety assessment study. The success of this and similar, related studies has led to the intent to apply DBS technology as the recommended analytical approach for the assessment of pharmacokinetics (PK)/TK for all new oral small molecule drug candidates, which have previously demonstrated a successful bioanalytical validation.  相似文献   

3.
The combination of affinity purification and tandem mass spectrometry (MS) has emerged as a powerful approach to delineate biological processes. In particular, the use of epitope tags has allowed this approach to become scaleable and has bypassed difficulties associated with generation of antibodies. Single epitope tags and tandem affinity purification (TAP) tags have been used to systematically map protein complexes generating protein interaction data at a near proteome-wide scale. Recent developments in the design of tags, optimisation of purification conditions, experimental design and data analysis have greatly improved the sensitivity and specificity of this approach. Concomitant developments in MS, including high accuracy and high-throughput instrumentation together with quantitative MS methods, have facilitated large-scale and comprehensive analysis of multiprotein complexes.  相似文献   

4.
We present the results of a study in which biomolecular interaction analysis (BIA, Biacoretrade mark 2000) was combined with mass spectrometry (MS) using entire "on-a-chip" procedure. Most BIA-MS studies included an elution step of the analyte prior MS analysis. Here, we report a low-cost approach combining Biacore analysis with homemade chips and MS in situ identification onto the chips without elution step. First experiments have been made with rat serum albumin to determine the sensitivity and validation of the concept has been obtained with an antibody/antigen couple. Our "on-a-chip" procedure allowed complete analysis by MS/MS(2) of the biochip leading to protein identifications at low femtomole to sub-femtomole levels. Using this technique, identification of protein complexes were routinely obtained giving the opportunity to the "on-a-chip" processing to complete the BIA-MS approach in the discovery and analysis of protein complexes.  相似文献   

5.
A high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed and validated for the quantitative analysis of NIM811, a cyclophilin inhibitor, in human dried blood spot (DBS) samples, which were produced by spotting 20 μl whole blood onto FTA cards. A 3mm disc was cut from the DBS samples and extracted using methanol, followed by liquid-liquid extraction with MTBE. The reconstituted extracts were chromatographed using a Halo C(18) column and gradient elution for MS/MS detection. The possible impact of hematocrit, blood sample volume and punching location on DBS sampling was investigated. The results showed that blood sample volume or punching location has no impact on assay performance, but the presence of a high hematocrit resulted in significantly increased analyte concentrations measured from the high QC samples. The current method was fully validated over the range of 10.0-5000 ng/ml with correlation coefficients (r(2)) for three validation batches equal to or better than 0.991. The accuracy and precision (CV) at the LLOQ were -0.7 to 6.0% bias of the nominal value (10.0 ng/ml) and 10.2-2.3%, respectively. For the balance of QC samples (20.0, 50.0, 750, 1500 and 3750 ng/ml), the precision (CV) ranged from 3.2 to 11.7% and from 5.6 to 10.2%, respectively, for the intra-day and inter-day evaluations. The accuracy ranged from -6.8 to 8.5% and -0.2% to 2.7% bias, respectively, for the intra-day and inter-day batches. NIM811 is stable in the DBS samples for at least 24h at room temperature and 4h at 60°C. Interestingly, the long term stability (LTS) assessment showed that the stability of the analyte is better when the DBS samples were stored at a lower storage temperature (e.g. ≤ -60°C) compared to storage at room temperature. This is probably due to the interaction of the additives and/or other materials (e.g. cellulose, etc) on the DBS card with NIM811, a cyclic peptide. The current methodology has been applied to determine the NIM811 levels in DBS samples prepared from a clinical study.  相似文献   

6.
Deamidation of asparaginyl residues is a common posttranslational modification in proteins and has been studied extensively because of its important biological effects, such as those on enzymatic activity, protein folding, and proteolytic degradation. However, characterization of the sites of deamidation of a protein has been a difficult analytical problem. In this study, mass spectrometry has been used as an analytical tool to characterize the deamidation of barstar, an RNAse inhibitor. Upon incubation of the protein at alkaline pH for 5 h, intact mass analysis of barstar, using electrospray ionization quadrupole time-of-flight mass spectrometry (ESI QToF MS), indicated an increase in the mass of +2 Da, suggesting possible deamidation of the protein. The sites of deamidation have been identified using the conventional bottom-up approach using a capillary liquid chromatography connected on line to an ESI QToF mass spectrometer and top down approach by direct infusion of the intact protein and fragmenting inside MS. These chemical modifications are shown to lead to stabilization of an unfolding intermediate, which can be observed in equilibrium unfolding studies.  相似文献   

7.
In clinical and diagnostic proteomics, it is essential to develop a comprehensive and robust system for proteome analysis. Although multidimensional liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems have been recently developed as powerful tools especially for identification of protein complexes, these systems still some drawbacks in their application to clinical research that requires an analysis of a large number of human samples. Therefore, in this study, we have constructed a technically simple and high throughput protein profiling system comprising a two-dimensional (2D)-LC/MS/MS system which integrates both a strong cation exchange (SCX) chromatography and a microLC/MS/MS system with micro-flowing reversed-phase chromatography. Using the microLC/MS/MS system as the second dimensional chromatography, SCX separation has been optimized as an off-line first dimensional peptide fractionation. To evaluate the performance of the constructed 2D-LC/MS/MS system, the results of detection and identification of proteins were compared using digests mixtures of 6 authentic proteins with those obtained using one-dimensional microLC/MS/MS system. The number of peptide fragments detected and the coverage of protein sequence were found to be more than double through the use of our newly built 2D-LC/MS/MS system. Furthermore, this multidimensional protein profiling system has been applied to plasma proteome in order to examine its feasibility for clinical proteomics. The experimental results revealed the identification of 174 proteins from one serum sample depleted HSA and IgG which corresponds to only 1 microL of plasma, and the total analysis run time was less than half a day, indicating a fairly high possibility of practicing clinical proteomics in a high throughput manner.  相似文献   

8.
Advances in mass spectrometry (MS) have encouraged interest in its deployment in urine biomarker studies, but success has been limited. Urine exosomes have been proposed as an ideal source of biomarkers for renal disease. However, the abundant urinary protein, uromodulin, cofractionates with exosomes during isolation and represents a practical contaminant that limits MS sensitivity. Uromodulin depletion has been attempted but is labor- and time-intensive and may remove important protein biomarkers. We describe the application of an exclusion list (ExL) of uromodulin-related peptide ions, coupled with high-sensitivity mass spectrometric analysis, to increase the depth of coverage of the urinary exosomal proteome. Urine exosomal protein samples from healthy volunteers were subjected to tandem MS and abundant uromodulin peptides identified. Samples were run for a second time, while excluding these uromodulin peptides from fragmentation to allow identification of peptides from lower-abundance proteins. Uromodulin exclusion was performed in addition to dynamic exclusion. Results from these two procedures revealed 222 distinct proteins from conventional analysis, compared with 254 proteins after uromodulin exclusion, of which 188 were common to both methods. By unmasking a previously unidentified protein set, adding the ExL increased overall protein identifications by 29.7% to a total of 288 proteins. A fixed ExL, used in combination with conventional methods, effectively increases the depth of urinary exosomal proteins identified by MS, reducing the need for uromodulin depletion.  相似文献   

9.
Dried blood spots (DBS), a micro blood sampling technique, has recently gained interest in drug discovery and development due to its inherent advantages over the conventional whole blood, plasma or serum sample collection. Since the regulatory authorities have agreed to the use of blood as an acceptable biological matrix for drug exposure measurements, its applications have been extended not only to therapeutic drug monitoring but also to toxicokinetic and pharmacokinetic studies. The pharmaceutical industry is keen to promote DBS as a prominent tool in bioanalytical applications due to the financial, ethical and organizational issues involved in clinical trials. This could be accomplished due to the latest advances in modern analytical technology, particularly liquid chromatography–mass spectrometry. The present review discusses some of the emerging liquid chromatography–mass spectrometry technologies in improving DBS analysis for its innovative applications in the development of new drugs.  相似文献   

10.
Moxifloxacin (MFX) is a potential oral agent use in the treatment of multidrug-resistance tuberculosis (MDR-TB). Due to variability in pharmacokinetics and in vitro susceptibility of causative bacteria, therapeutic drug monitoring (TDM) of MFX is recommended. Conventional plasma sampling for TDM is facing logistical challenges, especially in limited resource areas, and dried blood spots (DBS) sampling may offer a chance to overcome this problem. The objective of this study was to develop a LC-MS/MS method for determination of MFX in dried blood spots (DBS) that is applicable for TDM. The influence of paper type, the hematocrit (Hct) and the blood volume per spot (V(b)) on the estimated blood volume in a disc (V(est)) was investigated. The extracts of 8mm diameter discs punched out from DBS were analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS) with cyanoimipramin as internal standard. The method was validated with respect to selectivity, linearity, accuracy, precision, sensitivity, recovery and stability. The effect of Hct and V(b) on LC-MS/MS analytical result was also investigated. The relationship between MFX concentrations in venous and finger prick DBS and those in plasma was clinically explored. V(est) was highly influenced by Hct while the effect of V(b) appeared to be different among paper types. Calibration curves were linear in the range of 0.05-6.00 mg/L with inter-day and intra-day precisions and biases of less than 11.1%. The recovery was 84.5, 85.1 and 92.6% in response to blood concentration of 0.15, 2.50 and 5.00 mg/L, respectively. A matrix effect of less than 11.9% was observed. MFX in DBS was stable for at least 4 weeks at room condition (temperature of 25°C and humidity of 50%). A large range of Hct value produced a significant analytical bias and it can be corrected with resulting DBS size. A good correlation between DBS and plasma concentrations was observed and comparable results between venous DBS and finger prick DBS was attained. This fully validated method is suitable for determination of MFX in dried blood spot and applicable for TDM.  相似文献   

11.
By the development of soft ionization such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), mass spectrometry (MS) has become an indispensable technique to analyze proteins. The combination of protein separation and identification such as two-dimensional gel electrophoresis and MS, surface-enhanced laser desorption/ionization-MS, liquid chromatography/MS, and capillary electrophoresis/MS has been successfully applied for proteome analysis of urine and plasma to discover biomarkers of kidney diseases. Some urinary proteins and their proteolytic fragments have been identified as biomarker candidates for kidney diseases. This article reviews recent advances in the application of proteomics using MS to discover biomarkers for kidney diseases.  相似文献   

12.
Mass spectrometry (MS) has become a powerful and widely utilized tool in the investigation of protein thiol chemistry, biochemistry, and biology. Very early biochemical studies of metabolic enzymes have brought to light the broad spectrum of reactivity profiles that distinguish cysteine thiols with functions in catalysis and protein stability from other cysteine residues in proteins. The development of MS methods for the analysis of proteins using electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI) coupled with the emergence of high-resolution mass analyzers has been instrumental in advancing studies of thiol modifications, both in single proteins and within the cellular context. This article reviews MS instrumentation and methods of analysis employed in investigations of thiols and their reactivity toward a range of small biomolecules. A selected number of studies are detailed to highlight the advantages brought about by the MS technologies along with the caveats associated with these analyses.  相似文献   

13.
Proteome profiling of human epithelial ovarian cancer cell line TOV-112D   总被引:3,自引:0,他引:3  
A proteome profiling of the epithelial ovarian cancer cell line TOV-112D was initiated as a protein expression reference in the study of ovarian cancer. Two complementary proteomic approaches were used in order to maximise protein identification: two-dimensional gel electrophoresis (2DE) protein separation coupled to matrix assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) and one-dimensional gel electrophoresis (1DE) coupled to liquid-chromatography tandem mass spectrometry (LC MS/MS). One hundred and seventy-two proteins have been identified among 288 spots selected on two-dimensional gels and a total of 579 proteins were identified with the 1DE LC MS/MS approach. This proteome profiling covers a wide range of protein expression and identifies several proteins known for their oncogenic properties. Bioinformatics tools were used to mine databases in order to determine whether the identified proteins have previously been implicated in pathways associated with carcinogenesis or cell proliferation. Indeed, several of the proteins have been reported to be specific ovarian cancer markers while others are common to many tumorigenic tissues or proliferating cells. The diversity of proteins found and their association with known oncogenic pathways validate this proteomic approach. The proteome 2D map of the TOV-112D cell line will provide a valuable resource in studies on differential protein expression of human ovarian carcinomas while the 1DE LC MS/MS approach gives a picture of the actual protein profile of the TOV-112D cell line. This work represents one of the most complete ovarian protein expression analysis reports to date and the first comparative study of gene expression profiling and proteomic patterns in ovarian cancer.  相似文献   

14.
Integral membrane proteins have not been readily amenable to the general methods developed for mass spectrometric (or internal Edman degradation) analysis of soluble proteins. We present here a sample preparation method and high performance liquid chromatography (HPLC) separation system which permits online HPLC-electrospray ionization mass spectrometry (ESI-MS) and -tandem mass spectrometry (MS/MS) analysis of cyanogen bromide cleavage fragments of integral membrane proteins. This method has been applied to wild type (WT) bacteriorhodopsin (bR), cysteine containing mutants of bR, and the prototypical G-protein coupled receptor, rhodopsin (Rh). In the described method, the protein is reduced and the cysteine residues pyridylethylated prior to separating the protein from the membrane. Following delipidation, the pyridylethylated protein is cleaved with cyanogen bromide. The cleavage fragments are separated by reversed phase HPLC using an isopropanol/acetonitrile/aqueous TFA solvent system and the effluent peptides analyzed online with a Finnigan LCQ Ion Trap Mass Spectrometer. With the exception of single amino acid fragments and the glycosylated fragment of Rh, which is observable by matrix assisted laser desorption ionization (MALDI)-MS, this system permits analysis of the entire protein in a single HPLC run. This methodology will enable pursuit of chemical modification and crosslinking studies designed to probe the three dimensional structures and functional conformational changes in these proteins. The approach should also be generally applicable to analysis of other integral membrane proteins.  相似文献   

15.
An important component of proteomic research is the high-throughput discovery of novel proteins and protein–protein interactions that control molecular events that contribute to critical cellular functions and human disease. The interactions of proteins are essential for cellular functions. Identifying perturbation of normal cellular protein interactions is vital for understanding the disease process and intervening to control the disease. A second area of proteomics research is the discovery of proteins that will serve as biomarkers for the early detection, diagnosis and drug treatment response for specific diseases. These studies have been referred to as clinical proteomics. To discover biomarkers, proteomics research employs the quantitative comparison of peptide and protein expression in body fluids and tissues from diseased individuals (case) versus normal individuals (control). Methods that couple 2D capillary liquid chromatography (LC) and tandem mass spectrometry (MS/MS) analysis have greatly facilitated this discovery science. Coupling 2D-LC/MS/MS analysis with automated genome-assisted spectra interpretation allows a direct, high-throughput and high-sensitivity identification of thousands of individual proteins from complex biological samples. The systematic comparison of experimental conditions and controls allows protein function or disease states to be modeled. This review discusses the different purification and quantification strategies that have been developed and used in combination with 2D-LC/MS/MS and computational analysis to examine regulatory protein networks and clinical samples.  相似文献   

16.
We introduce Decomp, a tool that computes the sum formula of all molecules whose mass equals the input mass. This problem arises frequently in biochemistry and mass spectrometry (MS), when we know the molecular mass of a protein, DNA or metabolite fragment but have no other information. A closely related problem is known as the Money Changing Problem (MCP), where all masses are positive integers. Recently, efficient algorithms have been developed for the MCP, in which Decomp applies to real-valued MS data. The excellent performance of this method on proteomic and metabolomic MS data has recently been demonstrated. Decomp has an easy-to-use graphical interface, which caters for both types of users: those interested in solving MCP instances and those submitting MS data. AVAILABILITY: Decomp is freely accessible at http://bibiserv.techfak.uni-bielefeld.de/decomp/.  相似文献   

17.
IMAC in combination with mass spectrometry is a promising approach for global analysis of protein phosphorylation. Nevertheless this approach suffers from two shortcomings: inadequate efficiency of IMAC and poor fragmentation of phosphopeptides in the mass spectrometer. Here we report optimization of the IMAC procedure using (32)P-labeled tryptic peptides and development of MS/MS/MS (MS3) for identifying phosphopeptide sequences and phosphorylation sites. The improved IMAC method allowed recovery of phosphorylated tryptic peptides up to approximately 77% with only minor retention of unphosphorylated peptides. MS3 led to efficient fragmentation of the peptide backbone in phosphopeptides for sequence assignment. Proteomics of mitochondrial phosphoproteins using the resulting IMAC protocol and MS3 revealed 84 phosphorylation sites in 62 proteins, most of which have not been reported before. These results revealed diverse phosphorylation pathways involved in the regulation of mitochondrial functions. Integration of the optimized batchwise IMAC protocol with MS3 offers a relatively simple and more efficient approach for proteomics of protein phosphorylation.  相似文献   

18.
Analysis of complex protein-polypeptide systems for proteomic studies   总被引:1,自引:0,他引:1  
Two-dimensional polyacrylamide gel electrophoresis (2-D PAGE), followed by protein extraction and characterization with chemical sequencing or mass spectrometry (MS), is the most commonly used method to analyze complex protein systems such as cells and organelles. However, it is claimed that 2-D PAGE is a slow and labor-intensive technique and also needs subsequent efforts for one-by-one identification of proteins. Recently, the combined methods of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry, with preceding separation techniques such as capillary isoelectric focusing (CIEF) or liquid chromatography, have been demonstrated as high-throughput techniques suitable for proteomic analysis of protein systems. The studies which employ FTICR MS, aimed at the analysis of complex protein systems, have been reviewed, comparing their performance with that of 2-D PAGE. Also, the possibilities of combining 2-D PAGE and the FTICR MS method to analyze and reconstruct the structures and functions of complex systems are discussed.  相似文献   

19.
The field of proteomics is rapidly turning towards targeted mass spectrometry (MS) methods to quantify putative markers or known proteins of biological interest. Historically, the enzyme-linked immunosorbent assay (ELISA) has been used for targeted protein analysis, but, unfortunately, it is limited by the excessive time required for antibody preparation, as well as concerns over selectivity. Despite the ability of proteomics to deliver increasingly quantitative measurements, owing to limited sensitivity, the leads generated are in the microgram per milliliter range. This stands in stark contrast to ELISA, which is capable of quantifying proteins at low picogram per milliliter levels. To bridge this gap, targeted liquid chromatography (LC) tandem MS (MS/MS) analysis of tryptic peptide surrogates using selected reaction monitoring detection has emerged as a viable option for rapid quantification of target proteins. The precision of this approach has been enhanced by the use of stable isotope-labeled peptide internal standards to compensate for variation in recovery and the influence of differential matrix effects. Unfortunately, the complexity of proteinaceous matrices, such as plasma, limits the usefulness of this approach to quantification in the mid-nanogram per milliliter range (medium-abundance proteins). This article reviews the current status of LC/MS/MS using selected reaction monitoring for protein quantification, and specifically considers the use of a single antibody to achieve superior enrichment of either the protein target or the released tryptic peptide. Examples of immunoaffinity-assisted LC/MS/MS are reviewed that demonstrate quantitative analysis of low-abundance proteins (subnanogram per milliliter range). A strategy based on this technology is proposed for the expedited evaluation of novel protein biomarkers, which relies on the synergy created from the complementary nature of MS and ELISA.  相似文献   

20.
Glycosaminoglycans (GAGs) are heterogeneous, negatively charged, macromolecules that are found in animal tissues. Based on the form of component sugar, GAGs have been categorized into four different families: heparin/heparan sulfate, chondroitin/dermatan sulfate, keratan sulfate, and hyaluronan. GAGs engage in biological pathway regulation through their interaction with protein ligands. Detailed structural information on GAG chains is required to further understanding of GAG–ligand interactions. However, polysaccharide sequencing has lagged behind protein and DNA sequencing due to the non-template-driven biosynthesis of glycans. In this review, we summarize recent progress in the analysis of GAG chains, specifically focusing on techniques related to mass spectroscopy (MS), including separation techniques coupled to MS, tandem MS, and bioinformatics software for MS spectrum interpretation. Progress in the use of other structural analysis tools, such as nuclear magnetic resonance (NMR) and hyphenated techniques, is included to provide a comprehensive perspective.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号