首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
本文探索了自制起搏电极在心脏电生理研究中的应用,通过选择适当的材料,分为三部分制作电极:极片部分、起搏器接口部分、焊封与绝缘。最后,将电极缝合于犬的心脏进行起搏。结论是自制起搏电极应用于动物实验进行心脏电生理的研究是可行的。  相似文献   

2.
目的:分析经食道心房调搏术(TEAP)及食道内心电图(EECG)在心律失常中的应用价值。方法:选取2018年6月至2019年12月于我院行食道心电图及经食道调搏的患者189例,其中男80例,女109例,年龄11~83岁。结果:54例为房室结折返性心动过速(AVNRT),34例为房室折返性心动过速(AVRT),8例为房性心动过速(AT),4例为心房扑动(AF),6例为心房颤动(Af),5例为室性心过速,78例为室早或其他。共105例心律失常患者拟行食道心房调搏终止心动过速,所有AVNRT和AVRT患者及17例AT患者经食道心房调搏S1S1成功转为窦律,50例AVNRT、32例AVRT、6例AT、3例AF及2例VT患者通过射频消融术成功根治。其中1例11岁AT患者因无法耐受食道调搏,未能转为窦律,患者经静推普罗帕酮后次日转为窦律。共97例患者拟行食道心房调搏诱发,共49例诱发出心动过速,1例左后分支型室速经静滴异丙肾上腺素后诱发心动过速,且仍需静滴异丙肾上腺素后经心房食道调博终止心动过速,后经射频消融术成功根治。结论:TEAP及EECG可用于复杂心律失常的诊断及治疗,是一种相对安全、临床容易掌握的技术,值得推广。  相似文献   

3.
Fontan surgery and its modifications have improved survival in various forms of univentricular hearts. A regular atrial rhythm with atrioventricular synchrony is one of the most important prerequisite for the long-term effective functioning of this preload dependent circulation. A significant proportion of these survivors need various forms of pacing for bradyarrhythmias, often due to sinus nodal dysfunction and sometimes due to atrioventricular nodal block. The diversion of the venous flows away from the cardiac chambers following this surgery takes away the simpler endocardial pacing options through the superior vena cava. The added risks of thromboembolism associated with endocardial leads in systemic ventricles have made epicardial pacing as the procedure of choice. However challenges in epicardial pacing include surgical adhesions, increased pacing thresholds leading to early battery depletion and frequent lead fractures. When epicardial pacing fails, endocardial lead placement is equally challenging due to lack of access to the cardiac chambers in Fontan circulation. This review discusses the univentricular heart morphologies that may warrant pacing, issues about epicardial pacing, different techniques for endocardial pacing in patients with disconnected superior vena cava, pacing in different modifications of Fontan surgeries, issues of systemic thromboembolism with endocardial leads, atrioventricular valve regurgitation attributed to pacing leads and device infections. In a vast majority of patients following Glenn shunt and Senning surgery, an epicardial pacing and lead replacement is always feasible though technically very difficult. This article highlights the different options of transatrial and transventricular endocardial pacing.  相似文献   

4.
Excessive right ventricular apex pacing has significant adverse effects on the cardiac function and hence, it is necessary to clinically optimize pacing parameters and advocate suitable physiological pacing to safeguard the cardiac function after pacemaker implant. Minimizing ventricular pacing is an atrioventricular node priority function, to encourage ventricular self conduction and to reduce unnecessary right ventricular pacing. Minimized ventricular pacing reduces ventricular pacing by encouraging self atrioventricular conduction function and extending the AV interval. This study is a prospective cohort study to evaluate the changes of cardiac function in patients and serum amino-terminal natriuretic peptide (NT-proBNP) before and after pacing, and the risk of atrial fibrillation with different CUM% VP. The study has shown that the cardiac function will deteriorate with an increase in pacing rate.  相似文献   

5.

Background

Biventricular (BiV) is extensively used in the treatment of congestive heart failure but so far no recommendations for optimized programming of atrioventricular-delay (AVD) settings have been proposed. Can AVD optimization be performed using a simple formula based on non-invasive doppler-echocardiography?

Methods

25 patients (ejection fraction 30±8%) received BiV ICDs. Doppler-echocardiographic evaluation of diastolic and systolic flow was performed for different AVDs (30ms to 150ms) and different stimulation sites (left ventricular (LV), right ventricular and BiV). The optimal atrioventricular delay was calculated applying a simple formula based on systolic and diastolic mechanical delays determined during doppler-echocardiography.

Results

The mean optimal AVD was calculated to be 112±29ms (50 to 180ms) for BiV, 95±30ms (65 to 150ms) for LV and 75±28ms (40 to 125ms) for right ventricular pacing with wide interindividual variations. Compared to suboptimal AVDs diastolic optimization improved preejection and ejection intervals independent to pacing site. Optimization of the AVD significantly increased ejection time during BiV pacing (279ms versus 266ms; p<0.05). Compared to LV or right ventricular pacing BiV pacing produced the shortest mean pre-ejection and longest ejection intervals as parameters of improved systolic ventricular contractile synchrony. Diastolic filling times were longest during BiV pacing compared to LV or RV pacing.

Conclusions

Individual programming of BiV pacing devices increases hemodynamic benefit when implementing the inter-individually widely varying electromechanical delays. Optimization applying a simple formula not only improves diastolic ventricular filling but also increases systolic functional parameters.  相似文献   

6.

Background

In patients undergoing coronary artery bypass surgery (CABGS), occurrence of atrial fibrillation (AF) is common in the postoperative period and is associated with increased morbidity with longer intensive unit care (ICU) and hospital stay. Prevention with antiarrhythmic drugs is of limited success and associated with significant side effects. Therefore alternative approaches, such as Bachmann Bundle pacing, are required.

Methods and Results

154 consecutive patients, mean age 58±8.8 years, including 134 males and 20 females, were randomized to three groups; Group I : No pacing n= 54, Group II : RA pacing n= 52, Group III : Bachmann Bundle pacing n= 48. All the groups were well matched with regard to age, left atrial size, ejection fraction and use of beta blockers. Patients in Groups II and III were continually paced at a rate of 100 beats per minute (bpm) or at 10 bpm more than patients'' intrinsic heart rate. All the patients were monitored for 72 hours by telemetry and occurrence of AF was noted. Incidence of AF was 0% (none of 48 patients) in Group III as compared to 16.6% in Group I (9 of 54 patients) (p 0.003) and 12.5% in Group II (5 of 52 patients) (p 0.03). There was a trend towards shorter ICU stay in Group III (3.9 days) as compared to Group II (4.5 days) and Group I (4.1 days). Among the three groups, the reduction in mean P wave duration also was greater in Bachmann bundle paced group.

Conclusion

In patients undergoing CABGS, Bachmann bundle pacing is superior to right atrial / no pacing in the post operative period for preventing occurrence of AF and reducing ICU stay, commensurate with a reduction in mean P wave duration on surface ECG.  相似文献   

7.
We present the case of a patient with a heart failure episode induced by acute right ventricular pacing. After reversal of beta-blockers because of chronic obstructive pulmonary disease (COPD) exacerbation, the following sinus tachycardia caused a 2:1 atrioventricular block and consequent continuous right ventricular pacing. He was treated with the selective I(f) inhibitor ivabradine, that reduced both ventricular pacing percentage and heart rate without affecting atrioventricular conduction. Ivabradine may be a valuable option in treatment of patients with atrioventricular conduction disturbances.  相似文献   

8.
Despite the major advances in medical drug therapy, heart failure remains a syndrome associated with high mortality and morbidity. Biventricular or left ventricular (LV) short atrioventricular (AV) delay pacing is being tested in congestive heart failure patients with left bundle branch block. The aim is to resynchronise the dyscoordinate LV contraction. A number of studies are underway, but it is clear that while some patients respond remarkably, this is highly variable. Accurate identification of patients likely to benefit will be crucial. The mechanism of benefit is unclear. A greater understanding of the physiological consequences of pacing will be necessary to accurately identify these patients.  相似文献   

9.
OBJECTIVE--To compare present pacing practice with the recommendations recently published by the British Pacing and Electrophysiology Group and to assess the increase in annual budget required to implement these recommendations in a regional cardiothoracic unit. DESIGN--Retrospective analysis of pacemaker implantation for 1991 with calculation of the costs required to implement the group''s recommendations based on average 1991 costs of the types of pacing generators and electrode leads used. SETTING--Regional cardiothoracic unit for South West Thames Health Authority. PATIENTS--433 consecutive patients receiving permanent pacemaker generators: 76 (18%) with sinus node disease; 270 (62%) with atrioventricular block; 25 (6%) with both sinus node disease and atrioventricular block; 59 (14%) with chronic atrial fibrillation and atrioventricular block; and 3 (1%) with carotid sinus or malignant vasovagal syndromes. RESULTS--Only 102 (24%) patients received pacemaker generators recommended by the British Pacing and Electrophysiology Group; however, 355 (82%) patients were older than 65 years, and 264 (61%) were aged 75 or over. The cost of hardware for pacing was 462,885 pounds. Using generators as recommended would have cost 810,525 pounds for "optimal" systems (an increase of 75%) and 710,750 pounds for "alternative" systems (an increase of 54%). These increases would have been considerably reduced by limiting the use of sophisticated pacing to younger patients (aged under 75). Further savings could be made by using the least expensive pacing models available. CONCLUSIONS--Implementing these recommendations should reduce morbidity related to bradyarrhythmia but will lead to major increases in pacing costs. Age and patients'' expected activity may be used to select simple pacing systems and thus to contain cost. More research is needed to determine which patient groups will benefit most from complex pacing systems.  相似文献   

10.
The population of children and young adults requiring a cardiac pacing device has been consistently increasing. The current generation of devices are small with a longer battery life, programming capabilities that can cater to the demands of the young patients and ability to treat brady and tachyarrhythmias as well as heart failure. This has increased the scope and clinical indications of using these devices. As patients with congenital heart disease (CHD) comprise majority of these patients requiring devices, the knowledge of indications, pacing leads and devices, anatomical variations and the technical skills required are different than that required in the adult population. In this review we attempt to discuss these specific points in detail to improve the understanding of cardiac pacing in children and young adults.  相似文献   

11.
Adult congenital heart disease patients may undergo numerous fluoroscopically guided procedures including pacemaker implantation during their lifetime. One alternative to traditional pacemaker setup which may improve long-term pacing outcomes is His bundle pacing. Given the altered His-bundle location, and given increased radiation exposure over a lifetime, we used 3-dimensional mapping to locate the His and to minimize fluoroscopy for placement of a His-bundle pacemaker system in a 31-year old patient with atrioventricular canal defect and complete heart block with 100% RV pacing and epicardial lead fracture.MethodsAn Octapolar Livewire catheter (Abbott, Minneapolis, USA) was used for mapping and location of the His bundle from a right femoral venous access on the EnSite Precision system 3-dimensional mapping system (Abbott Medical, Abbott Park, IL). The same map was used to guide 3830 lead placement into the posterior-inferior His-bundle position.ResultsSuccessful placement of a His-bundle pacing system with thresholds of 1Volt@0.4ms for both the atrial and ventricular leads with selective His-bundle pacing noted. Ten-month follow-up demonstrated His-bundle capture at 0.75V@0.4ms with stable impedance, sensing and with 100% right ventricular pacing a projected longevity of 12 years total.ConclusionsSuccessful placement of selective His-bundle pacing can be achieved in an adult patient with atrioventricular canal defect using 3-dimensional mapping.  相似文献   

12.
目的:探讨临时起搏器与阿托品在急性下壁心肌梗死急诊经皮冠状动脉介入治疗(PCI)中应用的疗效。方法:入选2012 年2 月至2013 年8 月我院收治的发病12 小时内,诊断为急性下壁心肌梗死并接受急诊PCI治疗的患者92 例,依据治疗方法的不同 将病例分为临时起搏组和阿托品组,并对病例进行为期一年的追踪随访,收集患者平均住院天数、平均住院费用、再灌注心律失 常、心肌梗死后心绞痛、心肌梗死后心衰发生率资料。结果:临时起搏组的平均住院天数、平均住院费用、心肌梗死后心绞痛、心肌 梗死后心衰发生率均显著低于阿托品治疗组(P 均<0.05),阿托品治疗组的再灌注心律失常发生率则明显低于临时起搏组(P<0. 05)。结论:急性下壁心肌梗死急诊PCI中应用临时起搏器,具有治疗成本低,降低心血管事件发生率的优点,而阿托品治疗在改 善再灌注心律失常的疗效上则显著优于临时起搏治疗。  相似文献   

13.
Dwight I. Peretz 《CMAJ》1967,96(8):451-456
The mortality rate is high from advanced atrioventricular block associated with acute myocardial infarction. There is reason to believe that if in these patients the hearts are electrically paced with an endocardial pacing catheter, the mortality rate can be considerably decreased. Five patients in second- and third-degree heart block associated with acute myocardial infarction were paced with a considerable lowering of the expected mortality rate. Twenty-three cases from the literature are also presented and discussed. A silastic bipolar electrode catheter was used in these five cases. Four of the five cases returned to normal sinus rhythm within the first 10 days. The average duration of pacing was 6.7 days. It is the opinion of the author that second- and third-degree heart block associated with acute myocardial infarction should have a pacing catheter introduced at the earliest possible moment for continuous or demand endocardial pacing.  相似文献   

14.
BackgroundLeft bundle branch (LBB) pacing is a novel pacing technique which may serve as an alternative to both right ventricular pacing for symptomatic bradycardia and cardiac resynchronisation therapy (CRT). A substantial amount of data is reported by relatively few, highly experienced centres. This study describes the first experience of LBB pacing in a high-volume device centre.MethodsSuccess rates (i.e. the ability to achieve LBB pacing), electrophysiological parameters and complications at implant and up to 6 months of follow-up were prospectively assessed in 100 consecutive patients referred for various pacing indications.ResultsThe mean age was 71 ± 11 years and 65% were male. Primary pacing indication was atrioventricular (AV) block in 40%, CRT in 42%, and sinus node dysfunction or refractory atrial fibrillation prior to AV node ablation in 9% each. Baseline left ventricular ejection fraction was < 50% in 57% of patients, mean baseline QRS duration 145 ± 34 ms. Overall LBB pacing was successful in 83 of 100 (83%) patients but tended to be lower in patients with CRT pacing indication (69%, p = ns). Mean left ventricular activation time (LVAT) during LBB pacing was 81 ms and paced QRS duration was 120 ± 19 ms. LBB capture threshold and R‑wave sense at implant was 0.74 ± 0.4 mV at 0.4 ms and 11.9 ± 5.9 V and remained stable at 6‑month follow-up. No complications occurred during implant or follow-up.ConclusionLBB pacing for bradycardia pacing and resynchronisation therapy can be easily adopted by experienced implanters, with favourable success rates and safety profile.  相似文献   

15.
Objective: A gastric pacemaker has been developed to treat morbid obesity. Patients experience increased satiety, the ability to reduce food intake, and a resultant weight loss. However, the mechanism behind the changed eating behavior in paced patients is still under investigation. Research Methods and Procedures: This study was performed on 11 morbidly obese patients (mean BMI, 46.0 kg/m2) treated with gastric pacing. The peripheral blood levels of satiety signals of cholecystokinin (CCK), somatostatin, glucagon‐like peptide‐1 (GLP‐1), and leptin were studied 1 month before gastric pacer implantation, 1 month after implantation, and 6 months after activation of electrical stimulation. Blood samples were drawn 12 hours after fasting and in response to a hypocaloric meal (270 kcal). Patients were followed monthly for vital signs and weight level. Results: Gastric pacing resulted in a significant weight loss of a mean of 10.4 kg (4.4 BMI units). No negative side effects or complications were observed during the treatment. After activation of the pacemaker, meal‐related response of CCK and somatostatin and basal levels of GLP‐1 and leptin were significantly reduced (p < 0.05) compared with the tests before gastric pacing. The weight loss correlated significantly with a decrease of leptin levels (R = 0.79, p < 0.01). Discussion: Gastric pacing is a novel and promising therapy for morbid obesity. Activation of the gastric pacer was associated with a decrease in plasma levels of CCK, somatostatin, GLP‐1, and leptin. More studies are necessary to elucidate the correlations between satiety, weight loss, and digestive neuro‐hormone changes.  相似文献   

16.
Although great strides have been made in the areas of ventricular pacing, it is still appreciated that dyssynchrony can be malignant, and that appropriately placed pacing leads may ameliorate mechanical dyssynchrony. However, the unknowns at present include:1. The mechanisms by which ventricular pacing itself can induce dyssynchrony;2. Whether or not various pacing locations can decrease the deleterious effects caused by ventricular pacing;3. The impact of novel methods of pacing, such as atrioventricular septal, lead-less, and far-field surface stimulation;4. The utility of ECG and echocardiography in predicting response to therapy and/or development of dyssynchrony in the setting of cardiac resynchronization therapy (CRT) lead placement;5. The impact of ventricular pacing-induced dyssynchrony on valvular function, and how lead position correlates to potential improvement.This review examines the existing literature to put these issues into context, to provide a basis for understanding how electrical, mechanical, and functional aspects of the heart can be distorted with ventricular pacing. We highlight the central role of the mitral valve and its function as it relates to pacing strategies, especially in the setting of CRT. We also provide future directions for improved pacing modalities via alternative pacing sites and speculate over mechanisms on how lead position may affect the critical function of the mitral valve and thus overall efficacy of CRT.  相似文献   

17.
目的应用心内电生理技术研究心房快速起搏(RAP)对兔心房单向动作电位(MAP)的影响。方法成年新西兰兔20只随机分为二组:假手术组、模型组各10只。经颈内静脉将电极置入右心房。以600次/分行RAP,同时分析在0、4、8、12和24h的单向动作电位时程(MAPD)。结果假手术组在实验的时间段内右房游离壁MAP复极90%时程(MAPD90)无明显差别。RAP8h,起搏组右房游离壁MAPD90较P0有明显缩短,从起搏前(112.50±9.57)ms至起搏8h分别缩短到(51.25±4.79)ms,分别缩短了61.25ms。结论房颤(AF)时心房MAPD90缩短。MAP技术可安全地用于研究AF时的电重构(ER),能提供准确的电生理改变的信息。  相似文献   

18.
Right ventricular (RV) mid-septal pacing should have fewer negative effects on left ventricular function compared to apical pacing. However, targeting the mid-septum may be technically challenging since it is usually done with two-dimensional fluoroscopy. The rotation of the heart and various shapes of the RV make it difficult to assess, whether the lead is really anchored in the septum. Many leads, apparently anchored in the septum, are in fact anchored in the anterior wall or anteroseptal groove, and some can get anchored in close proximity to the left anterior descending artery (LAD). We report three cases from our series of 51 patients, in whom the RV lead thought to be implanted in the mid-septum was in fact anchored in close proximity of LAD when assessed using computed tomography.  相似文献   

19.
BackgroundPhrenic nerve stimulation (PNS) and high pacing thresholds (HPT) hinder biventricular stimulation in patients (pts) undergoing cardiac resynchronization therapy (CRT). A new quadripolar left ventricular (LV) lead (Quartet 1458Q, St. Jude Medical) with increased number of pacing configuration, might overcome this problem.MethodsAll consecutive pts in whom a standard bipolar lead intraoperatively resulted in PNS and/or HPT (≥ 4.00 V/1 mV), received, during the same implant, a quadripolar LV lead. Aim of the study was to evaluate acute and short term outcome.Results26 pts [24 (92%) male, mean age 74 ± 6 years)] with PNS (22 pts; 85%) and HPT (4 pts; 15%) were included. Permanent right ventricular pacing was the reason for broad QRS complex in 4 (15%) pts, whereas all other pts had a left bundle branch block. Severely symptomatic (NYHA Class ≥ 3) heart failure with reduced ejection fraction (EF 31 ± 9%) was mostly caused by ischemic heart disease (14 pts; 54%). Idiopathic dilated cardiomyopathy and valvular heart disease were diagnosed in 6 (23%) pts each. In most (24/26, 92%) pts the use of the Quartet lead led to successful biventricular pacing due to a significant reduction in intraoperative pacing threshold (5.2 V/1.0 ms vs. 1.4 V/0.8 ms; p = 0.03), which was maintained (1.2 V/0.7 ms) at follow-up. PNS never represented reason for failed LV pacing, neither acutely nor during follow-up.ConclusionsExcessively HPT and/or PNS are frequently encountered when conventional bipolar leads are used for CRT. A new quadripolar LV lead increases the rate of successful biventricular stimulation. Lower pacing threshold and freedom from PNS are maintained at follow-up.  相似文献   

20.
目的:探讨右室间隔部起搏患者起搏QRS波时限与心功能的关系。方法:回顾性分析植入右室间隔部起搏的双腔起搏器患者(111例),起搏器平均植入时间(4.52±3.65)年,通过常规体表心电图测得完全起搏时QRS波时限分为四组:A组为QRS≤120ms(21例);B组为120ms180ms(26例),行心脏彩色多普勒检查获取左房内径(LAD)、收缩末期左室内径(LVESD)、舒张末期左室内径(LVEDD)、室间隔厚度(IVST)、左室后壁厚度(LVPWT)及LVEF,同时检测患者的血清氨基末端脑肭肽前体(NT-proBNP),分析起搏QRS波时限与以上各指标的关系。结果:D组患者LAD、LVEDD、LVESD、IVST及IVPWT较其他三组明显增大,同时LVEF显著下降,NT-proBNP明显升高,有统计学意义(P<0.05)。同时发现随起搏QRS时限的不断增宽,不同组别的LVEF是依次降低(中位值分别为66.5%、60.3%、52.7%和45.8%),而血清NT-proBNP水平是依次增大(中位值分别为143.7 pg/ml、261.8 pg/ml、599.4 pg/m和971.2 pg/ml)。直线相关性分析示起搏QRS波时限与LAD(r=0.141,P<0.05)、LVEDd(r=0.678,P<0.05)、LVEDs(r=0.439,P<0.05)、IVST(r=0.165,P<0.05)及LVPWT(r=0.189,P<0.05)有显著线性关系,呈正相关。起搏QRS波时限与LVEF负相关(r=-0.684,P<0.05),起搏QRS波时限与NT-proBNP的对数正相关(r=0.368,P=0.029)。结论:对于右室间隔部起搏的双腔起搏患者,起搏QRS波时限是一个可初步判断心脏结构和功能的指标,其起搏QRS波时限延长可能会恶化患者的心脏结构及功能,可结合NT-proBNP进行动态观察,对起搏器植入患者的心功能恶化和心衰的预防有一定的临床实用价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号