首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A three-channel biotelemetry system measuring ECG, respiration, and body temperature is described. The transmitter employs a 6-kHz subcarrier oscillator and is small enough for surgical implantation in animals the size of rats or larger. The frequency modulated 6-kHz tone from the reciver can be demodulated directly or recorded on an inexpensive cassette tape recorder for future analysis. The transmitter cost is approximately $35.00 and measures 3 times 1 cm. A battery life of several weeks and transmitter range of 10-100 m is typical. Transmission is on the FM broadcast band (88-108 MHz) and reception from an inexpensive FM portable receiver is possible.  相似文献   

2.
Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of electrical foil strain gauges applied to a cylindrical load cell. A piezo-resistive accelerometer (+/- 500 g) is used to calculate the displacement of the device through double integration of its signal, with the impact velocity used as a boundary condition. The signals from the strain gauge circuit and the accelerometer are sampled at 2500 Hz. The data are transmitted to a receiver via telemetry using a 418 MHz FM transmitter and from the receiver to a laptop PC via the serial port. Calibration of the device is described and sample results showing forces up to 2500 N and displacements up to 0.04 m are presented.  相似文献   

3.
The range of application of implantable stimulators in functional electrical stimulation (FES) for therapeutic purposes and for the restoration of lost or damaged functions has steadily grown within the last 20 years. Each time a clinically used method is improved, a new field of FES application explored or basic research conducted, animal experiments are needed to check and evaluate the findings and results. It is precisely for this use that the stimulation system described in this paper was developed. The battery-powered single-channel stimulator can be used for the excitation of motor and sensory nerves with monophasic or biphasic impulses. All parameters and functions are programmable via the bidirectional telemetry circuit. Implant programming is achieved by a laptop computer, supported by a graphical user interface, instead of by a specially designed programmer. The maximum settings of the stimulation parameters are: frequency 100 Hz, monophasic pulse duration 0.8 ms, biphasic pulse duration 1.6 ms, stimulation current 3 mA. The implant volume was reduced to 2 cm3 (length 23 mm, width 13 mm, height 7.5 mm), lowering the weight to 3.6 g. Due to this small volume the implant can be used in small animals. The power supply via battery obviates the need for transcutaneous tunneling or permanent external high-frequency senders and facilitates the keeping of the animals.  相似文献   

4.
This paper describes for the first time the possibility for recording the systolic pressure (SP), diastolic pressure (DP), and the mean arterial pressure (MAP) as well as the heart rate (HR) and locomotor activity (LA) in freely moving mice, using a commercially available telemetry and data acquisition system. The system comprises a new, small radio-telemetry transmitter implanted in the peritoneal cavity, a receiver board placed underneath the home cage, a multiplexer and a computer-based data acquisition system. The signals from the receiver were consolidated by the multiplexer and were stored and analysed by the computer. The telemetered pressure signals (absolute pressure) were corrected automatically for changes in atmospheric pressure measured by an ambient pressure monitor. The effects of implantation on animal behaviour, and, after the animals had recovered, the effects of handling on the SP, DP, MAP and HR were examined. The radio-telemetry system for recording the SP, DP, MAP and HR provides an accurate and reliable method for monitoring the direct effects of handling on SP, DP, MAP and HR. In addition, by using this new blood pressure (BP) transmitter, we maintain that BP measurements in freely moving mice are more efficient, reliable, and less labour-intensive than the measurement techniques described in the literature thus far.  相似文献   

5.
An inexpensive but reliable telemetry system for long-term, sequential monitoring of body temperature in up to 20 laboratory animals is described. The system consists of frequency-modulated (FM) temperature transmitters, remote-controlled power switches to extend battery life, a multi-channel telemetry receiver, and a frequency counter interfaced with a personal computer to record data. Analysis of body temperature data obtained from four New Zealand White rabbits confirms the reliability and value of this system.  相似文献   

6.
Poon PW  Chiu TW 《Bio Systems》2000,58(1-3):229-237
Complex sounds, including human speech, contain time-varying signals like frequency modulation (FM) and amplitude modulation (AM) components. In spite of various attempts to characterize their neuronal coding in the mammalian auditory systems, a unified view of their responses has not been reached. We compared FM and AM coding in terms of receptive space with reference to the input-output relationship of the underlying neural circuits. Using extracellular recording, single unit responses to a novel stimulus (i.e. random AM or FM tone) were obtained at the auditory midbrain of the anesthetized rat. Responses could be classified into three general types, corresponding to selective sensitivity to one of the following aspects of the modulation: (a) steady state, (b) dynamic state, or (c) steady-and-dynamic states. Such response typing was basically similar between FM and AM stimuli. Furthermore, the receptive space of each unit could be characterized in a three-dimensional Cartesian co-ordinate system formed by three modulation parameters: velocity, range and intensity. This representation applies to both FM and AM responses. We concluded that the FM and AM codings are very similar at the auditory midbrain and may likely involve similar neural mechanisms.  相似文献   

7.
Background impulse activity (BIA) of neuronal elements of the fastigial nucleus (FN) of rat cerebellum were investigated for the first time with the aid of various methods of statistical analysis. A clear predominance of stationary impulse flows (IFs) was discovered, along with irregularities in such flows, variously expressed and including a significant number of realizations of a regular component of impulse activity. Nonstationary IFs constituted a special variety of BIA; they were found in 15% of the total number of neurons investigated. Serial correlation analysis of the durations of interspike intervals (ISIs), both of stationary and nonstationary IFs, allowed us to identify six main varieties of ISI dynamics in the BIA of neurons of the fastigial nucleus. The patterns of recorded IFs and variations in IFs can serve as an adequate indices of the state of cellular activity during intracellular recording from cells of the central nervous system.L. A. Orbeli Institute of Physiology, Armenian Academy of Sciences, Yerevan. Translated from Neirofiziologiya, Vol. 23, No. 4, pp. 441–450, July–August, 1991.  相似文献   

8.
A miniature radiotelemetry transmitter is described suitable for chronic or acute monitoring of temperatures from animal or human subjects. The transmitters can be easily constructed with little or no electronics background from discrete components readily available from any electronics supplier. Transmitters weighed from 2.5-20 g, had volumes of 0.8-3.5 ml, had normal currents of 50-120 muA with potential transmitter lives of 35 h to greater than 1 yr, and transmission ranges of 10-30 m. Transmitters could be implanted, swallowed, or connected to chronically or acutely attached temperature probes. The design of the telemetry system allows for reception on any commercial FM receiver. Depending on mode of decoding the temperature data transmitter signal can be accurate to measure changes of from 0.15 to 0.015 degrees C. Thus with a minimum of expense and little electronics background a temperature-dependent transmitter system can be constructed for monitoring temperatures from unrestrained subjects.  相似文献   

9.
A biotelemetry system recording fish activity   总被引:2,自引:0,他引:2  
A biotelemetry system is described for obtaining, transmitting and recording the electromyograms (EMGs) produced in muscle activity of free-swimming fish as quantitative indicators of overall fish activity. The radiotransmitters used come in the form of cylindrical packages having two sensing electrodes, all fully implantable in the fish body cavity. EMGs are transmitted as radio pulses with the intensity of muscular activity determining the intervals between pulses. The packages also contain temperature sensors and fish temperatures are transmitted with every 32nd pulse. Transmitted EMG pulses are detected, 'measured' and stored by a single portable receiver (Model SRX_400, Lotek). Data can be subsequently transferred to a computer (which can also be portable) for storage, processing and statistical analysis. Transmitter battery life can be in excess of 7 months, permitting laboratory or field studies of long duration. Transmitter package implantation surgery requires a mid-ventral incision and internal securing of transmitter and sensing electrodes. Surgical silk, cyanoacrylate tissue adhesives, and polydioxanone (PD), a synthetic absorbable suture, were all tried as means of incision closure. The most effective was PD alone. Trials of the system consisted of forced swims by transmitter-equipped rainbow trout Oncorhynchus mykiss Walbaum. The data obtained provided an inverse linear relation between forced swim speed and EMG pulse interval. Trials were conducted at intervals over periods up to 2 months. Fish showed neither distress, nor difficulty in swimming up to maximum speeds of 60 cm s −1 (fish lengths 41.0, 44.4 cm).  相似文献   

10.
Angiotensin II and III have hypertensive effects. They induce vascular smooth muscle constriction, increase sodium reabsorption by renal tubules, stimulate the anteroventral third ventricle area, increase vasopressin and aldosterone secretions, and modify catecholamine metabolism. In this work, angiotensin II and III effects on norepinephrine uptake and release in rat adrenal medulla were investigated. Both angiotensins decreased total and neuronal norepinephrine uptake. Angiotensin II showed a biphasic effect only on evoked neuronal norepinephrine release (an earlier decrease followed by a later increase), while increasing the spontaneous norepinephrine release only after 12 min. On the other hand, angiotensin III showed a biphasic effect on evoked and spontaneous neuronal norepinephrine release. Both angiotensins altered norepinephrine distribution into intracellular stores, concentrating the amine into the granular pool and decreasing the cytosolic store. The results suggest a physiological biphasic effect of angiotensin II as well as angiotensin III that may be involved in the modulation of sympathetic activity in the rat adrenal medulla.  相似文献   

11.
Neuronal phospholipase D (PLD) activity was hypothesized to be involved in vesicle trafficking and endocytosis and, possibly, transmitter release. We here report that prolonged depolarization of rat hippocampal slices by potassium chloride (KCl) or 4-aminopyridine inhibited PLD activity. Similarly, PLD activity in rat cortical synaptosomes was significantly inhibited by depolarizing agents including veratridine and ouabain. Inhibition of calcium/calmodulin kinase II (CaMKII) which positively modulates synaptosomal PLD activity [Sarri et al. (1998) FEBS Lett. 440, 287-290] by KN-62 caused a further reduction of PLD activity in depolarized synaptosomes. Depolarization-induced inhibition of PLD activity was apparently not due to transmitter release or activation of other kinases. We observed, however, that KCl-induced depolarization caused an increase of inositol phosphates and a reduction of the synaptosomal pool of phosphatidylinositol-4, 5-bisphosphate (PIP(2)). Moreover, in synaptosomes permeabilized with Staphylococcus aureus alpha-toxin, PLD activation induced by calcium was abolished by neomycin, a PIP(2) chelator. We conclude that depolarizing conditions cause an inhibition of neuronal PLD activity which is likely due to breakdown of PIP(2), a required cofactor for PLD activity. Our findings suggest that neuronal PLD activity is regulated by synaptic activity.  相似文献   

12.
The effects of presynaptic impulse activity on the transmitter secretion at developing neuromuscular junctions were examined in Xenopus nerve-muscle cultures. Repetitive suprathreshold stimulation of the presynaptic neuron results in marked potentiation of spontaneous synaptic activity, as shown by whole-cell voltage-clamp recording of synaptic currents in the postsynaptic muscle cell. Our results are consistent with the notion that synaptic efficacy of the developing synapse is potentiated by the presence of electrical activity. Such activity-dependent synaptic modulation enables the early neuronal activity to play a regulatory role during the maturation of synaptic connections.  相似文献   

13.
Extracellular multi-unit recording is a widely used technique to study spontaneous and evoked neuronal activity in awake behaving animals. These recordings are done using either single-wire or multiwire electrodes such as tetrodes. In this study we have tested the ability of single-wire electrodes to discriminate activity from multiple neurons under conditions of varying noise and neuronal cell density. Using extracellular single-unit recording, coupled with iontophoresis to drive cell activity across a wide dynamic range, we studied spike waveform variability, and explored systematic differences in single-unit spike waveform within and between brain regions as well as the influence of signal-to-noise ratio (SNR) on the similarity of spike waveforms. We also modelled spike misclassification for a range of cell densities based on neuronal recordings obtained at different SNRs. Modelling predictions were confirmed by classifying spike waveforms from multiple cells with various SNRs using a leading commercial spike-sorting system. Our results show that for single-wire recordings, multiple units can only be reliably distinguished under conditions of high recording SNR (≥ 4) and low neuronal density (≈ 20,000/ mm(3)). Physiological and behavioural changes, as well as technical limitations typical of awake animal preparations, reduce the accuracy of single-channel spike classification, resulting in serious classification errors. For SNR <4, the probability of misclassifying spikes approaches 100% in many cases. Our results suggest that in studies where the SNR is low or neuronal density is high, separation of distinct units needs to be evaluated with great caution.  相似文献   

14.
The oxytocic and vasopressor activity was studied in five 1 mm thick, horizontal sections of the rat diencephalon. The diencephalon was cut frozen in dry ice. The sections obtained from identical parts of the diencephalon of 10 rats were homogenized together in 0.9% NaCl solution acidified with glacial acetic acid. The homogenate was heated to 100 degrees C for 5 min and centrifuged. The oxytocic activity of extracts was determined in vitro by, the method of Holton using the rat myometrium. The vasopressor activity was determined in vivo recording blood pressure in the carotid artery of rat by the method of Dekańaski. Oxytocic activity was found in all five sections of diencephalon and vasopressor activity in only two sections. The first section included the median eminence and ventral hypothalamus together with the supraoptic nucleus, the second section included the the dorsal hypothalamus with paraventricular nucleus, the third section--the ventral thalamus, the fourth section--the middle part of thalamus, the fifth section--the dorsal thalamus.  相似文献   

15.
B Bohus 《Biotelemetry》1974,1(4):193-201
To assess the effect of recording on the heart rate and on the behavior of the free moving rat, the electrocardiogram was recorded with the aid of radiotelemetry or through wire leads attached to the animal in different behavioral situations. Adaptation of heart rate both within and across sessions in the home cage and in a novel environment (open-field) was observed in rats bearing a transmitter. No adaptation occurred in rats attached to wire leads. The pattern of heart rate changes appeared to be independent of the mode of recording during passive avoidance behavior and when the rats displayed various motor activities like walking, sniffing, rearing or grooming in the open-field. The heart rate of rats attached to wire leads, however, was always higher. These data indicate that radiotelemetry is preferable to the use of wire connections for recording cardiac activity during behavioral studies in the rat.  相似文献   

16.
Close to two decades of research has established that astrocytes in situ and in vivo express numerous G protein-coupled receptors (GPCRs) that can be stimulated by neuronally-released transmitter. However, the ability of astrocytic receptors to exhibit plasticity in response to changes in neuronal activity has received little attention. Here we describe a model system that can be used to globally scale up or down astrocytic group I metabotropic glutamate receptors (mGluRs) in acute brain slices. Included are methods on how to prepare parasagittal hippocampal slices, construct chambers suitable for long-term slice incubation, bidirectionally manipulate neuronal action potential frequency, load astrocytes and astrocyte processes with fluorescent Ca2+ indicator, and measure changes in astrocytic Gq GPCR activity by recording spontaneous and evoked astrocyte Ca2+ events using confocal microscopy. In essence, a “calcium roadmap” is provided for how to measure plasticity of astrocytic Gq GPCRs. Applications of the technique for study of astrocytes are discussed. Having an understanding of how astrocytic receptor signaling is affected by changes in neuronal activity has important implications for both normal synaptic function as well as processes underlying neurological disorders and neurodegenerative disease.  相似文献   

17.
Neuronal correlates of a perceptual decision in ventral premotor cortex   总被引:11,自引:0,他引:11  
Romo R  Hernández A  Zainos A 《Neuron》2004,41(1):165-173
The ventral premotor cortex (VPC) is involved in the transformation of sensory information into action, although the exact neuronal operation is not known. We addressed this problem by recording from single neurons in VPC while trained monkeys report a decision based on the comparison of two mechanical vibrations applied sequentially to the fingertips. Here we report that the activity of VPC neurons reflects current and remembered sensory inputs, their comparison, and motor commands expressing the result; that is, the entire processing cascade linking the evaluation of sensory stimuli with a motor report. These findings provide a fairly complete panorama of the neural dynamics that underlies the transformation of sensory information into an action and emphasize the role of VPC in perceptual decisions.  相似文献   

18.
19.
Radiofrequency electric and magnetic fields have been measured around 11 large broadcast stations and tall FM/TV towers in Sweden. The results show that operating personnel may be exposed to fields exceeding by several times the present standard for occupational exposure to RF radiation. Maintenance personnel are especially vulnerable to exposure when climbing energized towers. The present study indicates that the transmitters should be switched off during the performance of certain tasks on the tower. Safe passage of maintenance personnel near energized antennas of certain types is impossible without a drastic reduction of the transmitted power. In the stations, the RF leakage radiation was generally low, but when work was done with the cabinet doors of the transmitter open, high field strengths were found in the vicinity of the transmitter even though it was switched off. It was found that the transmitter acted as a tuned receiver of energy from the other transmitters.  相似文献   

20.
Spencer  A. N. 《Hydrobiologia》1991,216(1):565-571
A family of peptides with the carboxy-terminus Arg-Phe-amide has been localized to specific subpopulations of neurons in every cnidarian species examined. These neurons are typically sensory in character or are associated with smooth muscle. Although a transmitter role for these peptides has been suggested for anthozoans at neuromuscular synapses, no such evidence is available for hydrozoans. Instead there is evidence that RF-amides can be modulators of neuronal activity which takes the form of a biphasic (inhibitory then excitatory) response in vivo, while in vitro only the inhibitory response is seen. Voltage clamp studies of identified motor neurons showed large, transitory outward currents when Pol-RF-amide peptide was applied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号