首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Separation and determination of thiamine phosphate esters were achieved by reversed-phase high-performance liquid chromatography (hplc) after conversion to corresponding thiochrome esters. The elution order was thiochrome triphosphate, thiochrome pyrophosphate, and thiochrome monophosphate by a system composed of 25 mm potassium phosphate buffer (pH 8.4) and 2.5% N,N-dimethylformamide. The minimum amount reproducibly detected was 0.05 pmol for each thiochrome phosphate. Thiamine phosphate esters in rat tissues were successfully determined by the reversed-phase hplc after alkaline oxidation of the tissue extract, which resulted in a good agreement in their contents to those obtained by the straight-phase hplc previously reported.  相似文献   

3.
4.
A multisteroid screening method has been developed based on the use of 1-[4-(2,3-dihydroxypropoxy)phenyl]-1-alkanones as retention index standards and UV absorbance spectra recorded on-line with a diode-array detector using reversed-phase high-performance liquid chromatographic gradient elution with acetonitrile and water. The effect of chromatographic conditions on retention indices of steroids were studied. The method was tentatively applied to profiling of steroids in serum samples.  相似文献   

5.
A simple, rapid and sensitive high-performance liquid chromatographic method was developed for determination of ibuprofen, (+/-)-(R, S)-2-(4-isobutylphenyl)-propionic acid, enantiomers in rat serum. Serum (0.1 ml) was extracted with 2,2,4-trimethylpentane/isopropanol (95:5, v/v) after addition of the internal standard, (S)-naproxen, and acidification with H(2)SO(4). Enantiomeric resolution of ibuprofen was achieved on ChiralPak AD-RH column with ultraviolet (UV) detection at 220 nm without interference from endogenous co-extracted solutes. The calibration curve demonstrated excellent linearity between 0.1 and 50 microg/ml for each enantiomer. The mean extraction efficiency was >92%. Precision of the assay was within 11% (relative standard deviation (R.S.D.)) and bias of the assay was lower than 15% at the limit of quantitation (0.1 microg/ml). The assay was applied successfully to an oral pharmacokinetic study of ibuprofen in rats.  相似文献   

6.
7.
A practical and sensitive high-performance liquid chromatographic method using normal solid-phase extraction has been developed for the determination of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7-OH-MTX) in human urine. A urine specimen followed by the addition of pH 5.0 acetate buffer was purified by solid-phase extraction on a Sep-Pak silica cartridge. The analyte was chromatographed on a reversed-phase Inertsil ODS-2 column using phosphate buffer-acetonitrile at pH 5.3 as the mobile phase, and the effluent from the column was monitored at 303 nm. A good linear relationship between peak height and concentration was found for both of MTX and 7-OH-MTX in the range 5 to 1000 ng/ml of human urine. The inter-day coefficients of variation for the assay (n=5) were 8.8% (5 ng/ml), 3.4% (50 ng/ml) and 2.0% (500 ng/ml) for MTX, and 7.2, 2.7 and 2.3% for 7-OH-MTX in urine, respectively. The present method should prove useful for the evaluation of urinary drug excretion in patients undergoing MTX low-dose therapy.  相似文献   

8.
An RP-HPLC assay was developed for a recombinant adenovirus type 5. During chromatography, intact adenovirus dissociated into its structural components (DNA and proteins) and the viral proteome was separated yielding a characteristic fingerprint. The individual components were identified by matrix-assisted laser desorption ionization time-of-flight mass spectroscopy, N-terminal sequencing and amino acid composition. The assay was utilized to measure adenovirus particle concentration through quantification of structural proteins. Each structural protein provided independent measurement of virus concentration allowing verification of accuracy. The assay sensitivity is at or below 2·108 particles. Contrary to the benchmark spectrophotometric assay, the RP-HPLC assay was shown to be insensitive to contaminants common for partially purified adenovirus preparations.  相似文献   

9.
A high-performance liquid chromatographic method for the simultaneous determination of flunitrazepam and four metabolites, desmethylflunitrazepam (DMF), 7-aminodesmethylflunitrazepam (7-NH2DMF), 7-aminoflunitrazepam (7-NH2F) and 3-hydroxyflunitrazepam (3-OHF), in serum is described. The method involves a simple extraction from alkalinized plasma (pH 9.5) into diethyl ether-chloroform (80:20, v/v). Prazepam was used as an internal standard for the quantification of the five compounds. Separation was achieved with a 10 μm RSil CN column (300×3.9 mm I.D.). The detection wavelength was set at 242 nm. The limits of detection ranged from 2.5 to 5 μg/l with a limit of quantification of 10 μg/l for all analytes.  相似文献   

10.
A high-performance liquid chromatographic method for the analysis of hydroxyproline and proline has been developed. The method is based on the derivatization of the secondary amino group with dabsyl-chloride after blocking of the primary amino group with o-phthalaldehyde. Dabsyl-hydroxyproline and dabsyl-proline were separated from other amino acids by high-performance liquid chromatography in the gradient elution mode, and eluted at 10.27 and 16.02 min, respectively. The correlations between the peak areas of dabsyl-hydroxyproline and dabsyl-proline were linear in the range from 20–200 pmol, with equations y = 1.10x − 0.80 (r = 0.999) and y = 1.12x − 0.52 (r = 0.999), respectively. The method was applied to the analysis of rat tail collagen, and the contents of hydroxyproline and proline were 1.55 ± 0.04 and 2.03 ± 0.04 nmol/μg, respectively.  相似文献   

11.
A sensitive high-performance liquid chromatographic method with ultraviolet detection was developed to quantitate methotrexate in serum-based calibrators, controls and patient samples. Sample clean-up was achieved with C18 Sep-Pak Classic cartridges. The chromatographic separation was accomplished on a 5-μm Ultrasphere ODS Beckman column. 8-Chlorotheophylline was used as an internal standard. The method was validated by recovery, linearity, accuracy and precision studies. Two standard curves were constructed to cover the high and the low ends of the calibrator range (0.05–1.0 μmol/l). Response was found linear over the whole range of the calibrator set with a correlation coefficient of 0.999 and 1.00 for the low-level and the high-level curves, respectively. Accuracy varied from 12% at the lowest level to 1.2% at the highest level. The precision study showed a C.V. of 14.4% at the lowest level and 3.3% at the highest level.  相似文献   

12.
Serum analysis represents an extreme challenge due to the dynamic range of the proteins of interest, and the high structural complexity of the constituent proteins. In serum, the quantities of proteins and peptides of interest range from those considered "high abundance", present at 2-70% by mass of total protein, to those considered "low abundance", present at 10(-12) M or less. This range of analytical target molecules is outside the realm of available technologies for proteomic analysis. Therefore, in this study, we have developed a workflow toward addressing the complexity of these samples through the application of multidimensional separation techniques. The use of reversed-phase methods for the separation and fractionation of protein samples has been investigated, with the goal of developing an optimized serum separation for application to proteomic analysis. Samples of human serum were depleted of the six most abundant proteins, using an immunoaffinity LC method, then were separated under a variety of reversed-phase (RP) conditions using a macroporous silica C18 surface modified column material. To compare the qualities of the RP separations of this complex protein sample, absorbance chromatograms were compared, and fractions were collected for off-line SDS-PAGE and 2D-LC-MS/MS analysis. The column fractions were further investigated by determination of protein identities using either whole selected fractions, or gel bands excised from SDS-PAGE gels of the fractions. In either case samples underwent tryptic fragmentation and peptide analysis using MALDI-MS or LC-MS/MS. The preferred conditions for RP protein separation exhibited reproducibly high resolution and high protein recoveries (>98%, as determined by protein assay). Using the preferred conditions also permitted high column mass load, with up to 500 microg of protein well tolerated using a 4.6 mm ID x 50 mm column, or up to 1.5 mg on a 9.4 mm ID x 50 mm column. Elevated column temperature (80 degrees C) was observed to be a critical operational parameter, with poorer results observed at lower temperatures. The combination of sample simplification by immunoaffinity depletion combined with a robust and high recovery RP-HPLC fractionation yields samples permitting higher quality protein identifications by coupled LC-MS methods.  相似文献   

13.
14.
A high-performance liquid chromatographic (HPLC) method was designed to meet analytical and metrological requirements for routine blood level monitoring of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7OMTX). The metabolite, unavailable as a pure substance, was measured by reference to MTX calibration according to their respective ultraviolet absorbances. Acetonitrile deproteinization and chloroform clean-up provided plasma samples devoid of long-retained contaminants. The precision of the HPLC measurements, reproducibility of clean-up recovery, matrix effects and linearity were assessed by analysis of variance and linear regression in an appropriate experimental design, within a range from 0.205 to 16.7 mg/l of MTX and from 0.084 to 6.83 mg/l of 7OMTX. The clean-up recovery from plasma was 88% for MTX and 72% for 7OMTX, owing to retention on the protein precipitate. The assay was linear, the measurement precision was 3.3% for MTX and 6.2% for 7OMTX and the clean-up reproducibility was 4% for MTX and 3.6% for 7OMTX. By reference to automated fluorescence polarization immunoassay, the HPLC method resulted in plasma MTX values 10% lower, probably owing to the higher specificity of HPLC. Unsystematically sequenced plasma samples from 35 children following 24-h MTX infusions provided estimated half-decay times of 16 and 19 h for MTX and 7OMTX, respectively, and 7OMTX:MTX concentration ratios of 7 at 48 h and of 5 at 7 from starting infusions.  相似文献   

15.
16.
Gabapentin (GBP) is a new antiepileptic drug approved for clinical treatment of partial seizures in the USA. Serum GBP concentrations in 283 patients were studied using high-performance liquid chromatography with fluorescence detection. The standard curves were linear over a range of 60 ng to 15 μg/ml. The coefficient of variations were 3.4 to 8.8% and 1.4 to 9.8% for intra- and inter-assay studies, respectively. The lower limit of quantitation was 10 ng/ml. Of the 283 patients studied, 72.5% had GBP levels between 2 and 10 μg/ml, 14.8% were below 2 μg/ml and 12.7% above 10 μg/ml. The mean±S.E. of GBP in 283 patients was 5.38±0.23 μg/ml. Peak concentrations of more than 15 μg/ml and trough levels as low as 0.1 μg/ml were not uncommon. The method described was rapid, simple, highly sensitive and reproducible. Other antiepileptic drugs and endogenous compounds did not interfere with the assay.  相似文献   

17.
A rapid and sensitive high-pressure liquid chromatographic method for determination of methotrexate and its metabolites 7-hydroxymethotrexate and 2,4-diamino-N10-methylpteroic acid has been developed. The assay is based on isocratic reversed-phase chromatography with siliceous microparticulate Spherisorb (5 μm, ODS, 15 × 0.4 cm i.d.) as stationary phase and a ternary solvent mixture of citrate-phosphate (0.05 m, pH 3.2)/methanol/tetrahydrofurane (80:16:4, v/v) as eluant. A precolumn of Perisorb (RP2, 30–40 μm, 3 × 0.4 cm i.d.) reasonably protects the analytical column against deterioration by the components of plasma or other biological fluids. Since the samples of plasma, urine, or cerebrospinal fluid are directly injected into the chromatographic system, the method is very rapid. Within 8 min as little as 50 ng of methotrexate and its metabolites per milliliter (10?7m) can be measured with a precision better than 7%. Structural analogs of methotrexate do not interfere with the determination. There is a good correlation with the results of other methods, e.g., enzyme immunoassay or radioimmunoassay. The applicability for clinical monitoring in patient's plasma and urine is demonstrated.  相似文献   

18.
An assay for the quantitative estimation of 4-aminopyridine in biological fluids has been developed using 2-aminopyridine as internal standard and ion-pair reversed-phase (C1$$$) high-performance liquid chromatography with detection at 263 nm. A 7.5% solution of acetonitrile in water containing tetrabutylammonium iodide and sodium heptanesulfonate buffered at pH 3.0 provided excellent separation of the analytes from each other and from an interfering peak that was occasionally observed in the outdated human sera used in these studies. Sensitivity, specificity, precision, accuracy and reproducibility all were judged sufficient for the routine use of this assay for pharmacokinetic and pharmacodynamic studies.  相似文献   

19.
A simple and sensitive stereoselective high-performance liquid chromatographic assay for the quantitation of propranolol enantiomers in serum is described. The method involves conversion of the propranolol enantiomers to diastereomeric urea derivatives by reaction with the chiral reagent (+)-phenylethylisocyanate, followed by chromatographic separation of the diastereomeric products. Conditions of the derivatization reaction were optimized to achieve rapid and quantitative yield with either of the enantiomers. Baseline resolution of the diastereomers was achieved on a reversed phase C8 column with an isocratic mobile phase. Fluorescence detection afforded an absolute on-column detection limit of 100 pg. The assay has been applied to pharmacokinetic studies in humans and small laboratory animals.  相似文献   

20.
A reversed-phase high-performance liquid chromatography-photodiode-array method for the analysis of 23 drugs of forensic interest is presented. The separation method development was based on mobile-phase optimisation, temperature control and use of three ODS stationary phases. Multiwavelength detection and quantitation was performed at 225, 232, 239, 254, 275 and 289 nm. Absorbance ratioing proved to be very helpful for the identification of these drugs. Recognition of the analysed compounds was achieved by means of correlation of retention time and absorbance ratios. The method was directly applied to the analysis of illicit heroin and cocaine samples and to the analysis of pharmaceutical preparations containing codeine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号