Background

Cardiac resynchronization therapy (CRT) is indicated in symptomatic heart failure (HF) patients after achieving optimal medical therapy. However, there are still a large percentage of patients who do not respond to CRT. Malnutrition is a frequent comorbidity in patients with HF, and it is associated with a poorer prognosis. Here, we evaluate the nutritional status of patients assessed by Controlling Nutritional Status (CONUT) score and its association with structural remodeling and cardiovascular events.

Methods

We investigated the effect of CONUT on HF/death in 302 consecutive patients with a CRT device implanted between 2005 and 2015 in a single tertiary center. We categorized the patients into three groups: normal nutritional status (CONUT 0–1), mild malnutrition (CONUT 2–4) and moderate-severe malnutrition (CONUT?≥?5). Changes in nutritional status were assessed in patients with mild-to-severe malnutrition prior to CRT.

Results

One hundred and forty-eight patients exhibited normal nutritional status (49.0%), 99 patients exhibited mild malnutrition (32.8%) and 55 patients exhibited moderate-severe malnutrition (18.2%). CONUT scores of at least 2 were associated with higher risk of HF/death compared with CONUT 0–1. Significant left ventricular (LV) reverse remodeling was noted in patients with better nutritional status. In addition, those malnutrition patients at baseline that improved nutritional state exhibited fewer HF/death events at follow-up.

Conclusion

CONUT score prior to CRT was an independent risk factor of death/HF and was correlated with LV reverse remodeling. Improvements in CONUT score during long-term follow-up were associated with a reduction in the rate of HF/death.  相似文献   

3.

Aims

Although cardiac resynchronisation therapy (CRT) is an established treatment to improve cardiac function, a significant amount of patients do not experience noticeable improvement in their cardiac function. Optimal timing of the delay between atrial and ventricular pacing pulses (AV delay) is of major importance for effective CRT treatment and this optimum may differ between resting and exercise conditions. In this study the feasibility of haemodynamic measurements by the non-invasive finger plethysmographic method (Nexfin) was used to optimise the AV delay during exercise.

Methods and results

Thirty-one patients implanted with a CRT device in the last 4 years participated in the study. During rest and in exercise, stroke volume (SV) was measured using the Nexfin device for several AV delays. The optimal AV delay at rest and in exercise was determined using the least squares estimates (LSE) method. Optimisation created a clinically significant improvement in SV of 10 %. The relation between HR and the optimal AV delay was patient dependent.

Conclusion

A potential increase in SV of 10 % can be achieved using Nexfin for optimisation of AV delay during exercise. A considerable number of patients showed benefit with lengthening of the AV delay during exercise.  相似文献   

4.
PurposeBiventricular pacing is a mainstay of therapy for patients with heart failure. However, lead implantations may fail due to anatomical reasons including the impossibility of coronary sinus cannulation.Methods and resultsA dual approach from the subclavian vein using a snare through a sheath and from the femoral vein using a steerable electrophysiology catheter was performed. Once the snare hooked the catheter, the latter was advanced into the coronary sinus and finally, the sheath could also be advanced in an “over-the-wire” technique.ConclusionThe snare technique for coronary sinus cannulation offers a “bail-out” strategy for left ventricular lead implantation.  相似文献   

5.
While cardiac resynchronization therapy (CRT) has been shown to reduce morbidity and mortality in heart failure (HF) patients, the fundamental mechanisms for the efficacy of CRT are poorly understood. The lack of understanding of these basic mechanisms represents a significant barrier to our understanding of the pathogenesis of HF and potential recovery mechanisms. Our purpose was to determine cellular mechanisms for the observed improvement in chronic HF after CRT. We used a canine model of chronic nonischemic cardiomyopathy. After 15 months, dogs were randomized to continued RV tachypacing (untreated HF) or CRT for an additional 9 months. Six minute walk tests, echocardiograms, and electrocardiograms were done to assess the functional response to therapy. Left ventricular (LV) midmyocardial myocytes were isolated to study electrophysiology and intracellular calcium regulation. Compared to untreated HF, CRT improved HF-induced increases in LV volumes, diameters and mass (p<0.05). CRT reversed HF-induced prolongations in LV myocyte repolarization (p<0.05) and normalized HF-induced depolarization (p<0.03) of the resting membrane potential. CRT improved HF-induced reductions in calcium (p<0.05). CRT did not attenuate the HF-induced increases in LV interstitial fibrosis. Using a translational approach in a chronic HF model, CRT significantly improved LV structure; this was accompanied by improved LV myocyte electrophysiology and calcium regulation. The beneficial effects of CRT may be attributable, in part, to improved LV myocyte function.  相似文献   

6.
Background and objectivesQuadripolar left ventricular (LV) leads in cardiac resynchronization therapy (CRT) offer multi-vector pacing with different pacing configurations and hence enabling LV pacing at most suitable site with better lead stability. We aim to compare the outcomes between quadripolar and bipolar LV lead in patients receiving CRT.MethodsIn this prospective, non-randomized, single-center observational study, we enrolled 93 patients receiving CRT with bipolar (BiP) (n = 31) and quadripolar (Quad) (n = 62) LV lead between August 2016 to August 2019. Patients were followed for six months, and outcomes were compared with respect to CRT response (defined as ≥5% absolute increase in left ventricle ejection fraction), electrocardiographic, echocardiographic parameters, NYHA functional class improvement, and incidence of LV lead-related complication.ResultsAt the end of six months follow up, CRT with quadripolar lead was associated with better response rate as compared to bipolar pacing (85.48% vs 64.51%; p = 0.03), lesser heart failure (HF) hospitalization events (1.5 vs 2; p = 0.04) and better improvement in HF symptoms (patients with ≥1 NYHA improvement 87.09% vs 67.74%; p = 0.04). There were fewer deaths per 100 patient-year (6.45 vs 9.37; p = 0.04) and more narrowing of QRS duration (Δ12.56 ± 3.11 ms vs Δ7.29 ± 1.87 ms; p = 0.04) with quadripolar lead use. Lead related complications were significantly more with the use of bipolar lead (74.19% vs 41.94%; p = 0.02).ConclusionsOur prospective, non-randomized, single-center observational study reveals that patients receiving CRT with quadripolar leads have a better response to therapy, lesser heart failure hospitalizations, lower all-cause mortality, and fewer lead-related complications, proving its superiority over the bipolar lead.  相似文献   

7.
In cardiac resynchronisation therapy, failure to implant a left ventricular lead in a coronary sinus branch has been reported in up to 10% of cases. Although surgical insertion of epicardial leads is considered the standard alternative, this is not without morbidity and technical limitations. Endocardial left ventricular pacing can be an alternative as it has been associated with a favourable acute haemodynamic response compared with epicardial pacing in both animal and human studies. In this paper, we discuss left ventricular endocardial pacing and compare it with epicardial surgical implantation. Ease of application and procedural complications and morbidity compare favourably with epicardial surgical techniques. However, with limited experience, the most important concern is the still unknown long-term risk of thromboembolic complications. Therefore, for now endovascular implants should remain reserved for severely symptomatic heart failure patients and patients at high surgical risk of failed coronary sinus implantation.  相似文献   

8.
We report two cases of patients of cardiac resynchronization therapy (CRT) whose ECGs, during follow up, showed different paced QRS morphology as compared to those of immediate post-device implantation. Parameters of leads, including sensitivity and capture thresholds, were unchanged. There was no lead dislodgement confirmed on fluoroscopy. The ECGs obtained in device off mode showed different intrinsic QRS morphology as compared to those of pre-implant morphology. These changes were attributable to electrolyte imbalance in one patient and progressive intraventricular conduction defect in the other. These cases demonstrate that intrinsic myocardial conduction pattern influences paced QRS morphology. Irreversible change in paced QRS morphology may indicate poor prognosis.  相似文献   

9.
This case highlights the importance of proper identification of congenital anomalies of the coronary sinus for the successful placement of left ventricular lead during cardiac resynchronization therapy device implantation. We discuss an alternate route for left ventricular lead placement via the vein of Marshall when the coronary sinus ostium in the right atrium was atretic and was facing difficulty initially in detecting the anomaly.  相似文献   

10.
BackgroundCardiac resynchronization therapy (CRT) has been shown to improve both the functional status and mortality of heart failure patients with left bundle branch block. Multiple recent studies suggest several mechanisms for proarrhythmia associated with CRT device.Case summaryA 51-year-old male with symptomatic non-ischemic cardiomyopathy and no previous history of ventricular arrhythmias underwent placement of a biventricular cardioverter-defibrillator. The patient developed sustained monomorphic ventricular tachycardia (VT) soon after implantation. The VT recurred despite reprogramming to right ventricular only pacing. The electrical storm resolved only after a subsequent discharge from the defibrillator caused inadvertent dislodgement of the coronary sinus lead. No recurrent VT occurred throughout 10-years follow up after urgent coronary sinus lead revision.DiscussionWe describe the first reported case of mechanically induced electrical storm due to the physical presence of the CS lead in a patient with a new CRT-D device. It is important to recognize mechanical proarrhythmia as a potential mechanism of electrical storm, as it may be intractable to device reprogramming. Urgent coronary sinus lead revision should be considered. Further studies on this mechanism of proarrhythmia are needed.  相似文献   

11.

Background

Cardiac Resynchronization Therapy (CRT) is indicated for the treatment of advanced heart failure with severe systolic dysfunction and intraventricular conduction delay. Patient selection for this technology is vital, though it remains unclear which patients benefit most from CRT. We tested the hypothesis that patients with non-ischemic cardiomyopathy have a superior mortality benefit from CRT than ischemic cardiomyopathy patients.

Methods

We evaluated 95 CRT patients to determine which factors predict mortality.

Results

Patients with non-ischemic cardiomyopathy had a significantly better prognosis than patients with ischemic cardiomyopathy.

Conclusion

Larger prospective studies can substantiate this finding and better delineate which patients benefit most from CRT.  相似文献   

12.
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF.

Methods and results

Seventeen patients (16 males, mean age 73?±?6 years, mean EF 25?±?5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103?±?22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up.

Conclusion

Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population.  相似文献   

13.

Introduction

With the recent publication of the negative DANISH trial, the mortality benefit of the implantable cardioverter-defibrillator (ICD) has been put in question in patients with non-ischemic cardiomyopathy (NICM). Because a majority of patients in DANISH receive cardiac resynchronization therapy (CRT) devices, we investigated in the present study the survival of recipients of CRT pacemakers (CRT-P) versus CRT ICDs (CRT-D) in a cohort of older (≥75 years) NICM patients at our institution.

Methods

A total of 135 NICM patients with CRT device were identified (42 with CRT-P and 93 with CRT-D) and were followed to the endpoint of all-cause mortality. Overall survival was compared between the CRT-P and CRT-D groups with adjustment for differences in baseline characteristics.

Results

Over a median follow-up of 46 months from the time of CRT device implantation, there were 54 total deaths (40%): 14 in the CRT-P (33%) and 40 in the CRT-D (43%) groups. Overall, CRT-P recipients had similar unadjusted mortality compared to CRT-D recipients (hazard ratio [HR] 1.04, 95% confidence interval [CI] 0.56–1.93), and this remained unchanged after adjusting for unbalanced covariates (HR 0.95, 95% CI 0.47–1.89) including left ventricular ejection fraction, used of angiotensin converting enzyme inhibitors/angiotensin receptor blockers, and the Charlson comorbidity index.

Conclusion

Our data support that in older NICM patients with CRT devices, the addition of ICD therapy does not improve survival.  相似文献   

14.
Recent literature indicates that torsion of the left ventricle (LV) is a promising predictor for response to cardiac resynchronisation therapy (CRT). Among patients with severe heart failure, 45 to 75% of patients show rigid body rotation, where the base and apex rotate in the same direction, instead of normal, opposite rotation. The occurrence of this phenomenon seems to be a good indicator for response to CRT. From this review, it can be concluded that LV torsion might be a welcome addition to current selection criteria.  相似文献   

15.
Cardiac resynchronization therapy-defibrillator (CRT-D) implantation is a therapeutic option for adult patients with congenital heart disease (CHD), bundle branch block, reduced ejection fraction and symptoms of heart failure. A new implantation approach guided by the electroanatomic mapping (EAM) has been developed to overcome some issues of the standard technique: non-responder patients, high x-ray exposure and use of iodinated contrast medium for coronary sinus angiography. This approach has not been previously described in the CHD population. We report a case of EAM-guided approach for CRT-D implantation in a young adult patient with CHD.  相似文献   

16.

Background

The contribution of right ventricular (RV) stimulation to cardiac resynchronisation therapy (CRT) remains controversial. RV stimulation might be associated with adverse haemodynamic effects, dependent on intrinsic right bundle branch conduction, presence of scar, RV function and other factors which may partly explain non-response to CRT. This study investigates to what degree RV stimulation modulates response to biventricular (BiV) stimulation in CRT candidates and which baseline factors, assessed by cardiac magnetic resonance imaging, determine this modulation.

Methods and results

Forty-one patients (24 (59 %) males, 67 ± 10 years, QRS 153 ± 22 ms, 21 (51 %) ischaemic cardiomyopathy, left ventricular (LV) ejection fraction 25 ± 7 %), who successfully underwent temporary stimulation with pacing leads in the RV apex (RVapex) and left ventricular posterolateral (PL) wall were included. Stroke work, assessed by a conductance catheter, was used to assess acute haemodynamic response during baseline conditions and RVapex, PL (LV) and PL+RVapex (BiV) stimulation.Compared with baseline, stroke work improved similarly during LV and BiV stimulation (∆+ 51 ± 42 % and ∆+ 48 ± 47 %, both p < 0.001), but individual response showed substantial differences between LV and BiV stimulation. Multivariate analysis revealed that RV ejection fraction (β = 1.01, p = 0.02) was an independent predictor for stroke work response during LV stimulation, but not for BiV stimulation. Other parameters, including atrioventricular delay and scar presence and localisation, did not predict stroke work response in CRT.

Conclusion

The haemodynamic effect of addition of RVapex stimulation to LV stimulation differs widely among patients receiving CRT. Poor RV function is associated with poor response to LV but not BiV stimulation.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-015-0770-x) contains supplementary material, which is available to authorized users.  相似文献   

17.
孙艳丹  王银  刘丽文  张军  拓胜军  左蕾  沈敏 《生物磁学》2013,(30):5869-5873
目的:观察短暂中断心脏再同步化治疗(CRT)后慢性心力衰竭患者(CHF)心脏运动同步性的变化,探讨CRT逆重构组与非逆重构组同步性的获益情况。方法:连续选择CRT术后6月以上的患者46例,根据左室收缩末容积减小≥15%分为逆重构组和非逆重构组。分别于起搏器关闭前及关闭后10分钟超声心动图检查房室间延迟(AVD)、心室间延迟(IVD)、2节段径向应变达峰时间标准差(PTrs-12SD)、12节段环向应变达峰时间标准差(PTcs-12SD)及16节段纵向应变达峰时间标准差(PTls-16SD),比较起搏器关闭前后上述参数的变化。结果:两组患者中断CRT 10分钟后AVD均减小(非逆重构组P〈0.05,逆重构组P〈0.01),逆重构组IVD减小(P〈0.01),非逆重构组IVD于CRT关闭后变化无统计学意义(P〉0.05);两组患者左室内同步化参数PTcs-12SD、PTrs-12SD、PTls-16SD在中断CRT 10分钟后的变化均无统计学意义(P〉0.05)。结论:中断CRT10分钟后,两组患者房室失同步均加重,仅逆重构组心室间失同步显著恶化。提示CRT期间,两组患者均可持续获得房室同步性益处,逆重构患者可获得心室间同步性益处;中断CRT10分钟后,两组左心室内同步性均未发生显著性改变,这种无差异的现象,需要进一步研究。  相似文献   

18.
目的:观察慢性心衰患者经心脏再同步化治疗(cardiac resynchronization therapy,CRT)的临床疗效,并分析CRT无应答的影响因素。方法:入选2010年1月至2015年7月上海长海医院心血管内科因心衰接受CRT的患者共47例,收集病史资料、手术资料、术后资料以及随访,比较CRT有无应答患者的临床特征,并通过多因素回归分析CRT无应答的危险因素。结果:纳入病例数共47例,其中CRT应答34例(72.3%),CRT无应答13例(27.7%)。CRT无应答组中心房颤动和冠脉问题发生率明显高于CRT应答组(P0.05);CRT应答组中左心房容积、右心房容积、左心室容积以及二尖瓣返流量均明显低于CRT无应答组(P0.05)。多因素回归分析显示患者合并心房颤动或冠脉问题是CRT无应答可以影响CRT的应答。结论:CRT对慢性心衰患者具有较好的疗效,而合并心房颤动或冠脉问题是预测慢性心衰患者CRT无应答的独立影响因素。  相似文献   

19.
The most advanced in vitro cardiac models are today based on the use of induced pluripotent stem cells (iPSCs); however, the maturation of cardiomyocytes (CMs) has not yet been fully achieved. Therefore, there is a rising need to move towards models capable of promoting an adult-like cardiomyocytes phenotype. Many strategies have been applied such as co-culture of cardiomyocytes, with fibroblasts and endothelial cells, or conditioning them through biochemical factors and physical stimulations. Here, we focus on mechanical stimulation as it aims to mimic the different mechanical forces that heart receives during its development and the post-natal period. We describe the current strategies and the mechanical properties necessary to promote a positive response in cardiac tissues from different cell sources, distinguishing between passive stimulation, which includes stiffness, topography and static stress and active stimulation, encompassing cyclic strain, compression or perfusion. We also highlight how mechanical stimulation is applied in disease modelling.  相似文献   

20.
摘要 目的:探讨血清胱抑素C(Cys-C)、总胆红素(TBiL)、肾上腺髓质中段肽(MR-proADM)、晚期糖基化终末产物(AGEs)与老年慢性心力衰竭(CHF)患者心功能和心脏再同步化治疗(CRT)应答的关系。方法:选择2020年3月至2022年1月我院收治的151例接受CRT治疗的老年CHF患者为研究对象,随访6个月,统计治疗应答情况。CRT治疗前检测血清Cys-C、TBiL、MR-proADM、AGEs水平,超声心动图检测心功能,分析血清Cys-C、TBiL、MR-proADM、AGEs与心功能的相关性以及与老年CHF患者CRT治疗应答的关系。结果:151例患者失访1例,余150例患者中无应答48例(无应答组),应答102例(应答组)。无应答组血清Cys-C、TBiL、MR-proADM、AGEs水平均高于应答组(P<0.05),且与左心室射血分数(LVEF)呈负相关(P<0.05),与左室舒张末期内径(LVEDD)和左室收缩末期内径(LVESD)呈正相关(P<0.05)。多因素Logistic回归分析结果显示缺血性心肌病、血清Cys-C、TBiL、MR-proADM、AGEs是老年CHF患者CRT治疗无应答的危险因素(P<0.05),LVEF是保护因素(P<0.05)。结论:CRT治疗无应答老年CHF患者血清Cys-C、TBiL、MR-proADM、AGEs水平升高,且与心功能下降有关。血清Cys-C、TBiL、MR-proADM、AGEs是CRT治疗无应答的危险因素,可为CRT治疗效果评估提供一定的参考。  相似文献   