首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

A complete, bidirectional conduction block in the cavotricuspid isthmus (CTI) represents the end-point of the typical atrial flutter ablation. We investigated the correlation between two criteria for successful ablation, one based on the atrial bipolar electrogram morphology before and after complete CTI conduction block, compared to the standard criteria of differential pacing and reversal in the right atrial depolarization sequence during coronary sinus (CS) pacing.

Method

We conducted a retrospective study in 111 patients (81 males, average age 62±10 years) who underwent an atrial flutter ablation during September 2007 - July 2009 in the Cardiology - Rehabilitation Hospital, UMF Cluj-Napoca. We assessed the presence of a bidirectional block at the end of the procedure using the standard criteria. We then analyzed the morphology of the bipolar atrial electrograms adjacent to the ablation line, before and after CTI conduction block.

Results

A change from a qRs morphology to a rSr'' morphology when pacing from the coronary sinus and from a rsr'' morphology to a QRS morphology when pacing from the low-lateral right atrium was associated with a CTI conduction block. Sensitivity (Se), specificity(Sp), positive predictive value (PPV), negative predictive value (NPV) were 96%, 89%, 99% and 67% respectively.

Conclusion

Our study suggests that the analysis of the atrial bipolar electrogram next to the ablation line before and after CTI ablation may be used as a reliable criterion to validate CTI conduction block due to its high sensitivity, specificity and positive predictive value.  相似文献   

2.
A 74-year old was considered for atrioventricular (AV) nodal ablation in view of atrial fibrillation (AF) with poorly controlled ventricular rate despite being on amiodarone. Targeted AV nodal ablation was successfully performed after identifying the target site for ablation by reviewing an ultra high-density map of the His region produced by automatic electrogram annotation.Key words: His bundle, atrioventricular node, cardiac mapping, catheter ablation  相似文献   

3.

Background

Cavo-tricuspid isthmus (CTI) block is currently assessed by coronary sinus (CS) pacing or low lateral and septal atrial pacing. Occasionally, CS catheterization through the femoral route can be difficult to perform or right atrial pacing can be problematic because of catheter instability or saturation of the atrial electrograms recorded near the catheter.

Objectives

Our aim was to evaluate the feasibility of assessing cavo-tricuspid isthmus block by means of right ventricular (RV) pacing in patients with ventriculo-atrial conduction, comparing it with CS pacing.

Methods

Circumannular activation was analyzed during CS and RV pacing in consecutive patients in sinus rhythm undergoing CTI ablation for typical atrial flutter. Patients without ventriculo-atrial conduction were excluded from the study. The linear lesion was created during RV pacing and split atrial signals on the ablation line were analyzed. CTI block was confirmed by analyzing local electrograms on the line of block and circumannular activation during CS and RV pacing.

Results

Out of 31 patients, 20 displayed ventriculo-atrial conduction (64%) and were included in the study. Before ablation, during RV stimulation, the collision front of circumannular activation shifted counterclockwise in contrast with the pattern observed during CS pacing. After ablation, circumannular activation was similar during CS and RV pacing, showing fully descending lateral right atrium activation, even if double potentials registered on the ablation line were less widely split during RV pacing than CS pacing (111±26 ms vs 128±30 , p=0.0001).

Conclusions

In patients with ventriculo-atrial conduction, tricuspid annulus activation during CS and RV pacing is similar, before and after CTI ablation. The occurrence of split atrial electrograms separated by an isoelectric interval registered on the line of block can be detected during CS or RV pacing. In patients with difficult CS catheterization via the femoral vein, before trying the subclavian or internal jugular route, if retrograde ventriculo-atrial conduction is present, RV pacing can be an easy trick to assess isthmus block.  相似文献   

4.

Background

Accessory pathway (AP) ablation is not always easy. Our purpose was to assess the age-related prevalence of AP location, electrophysiological and prognostic data according to this location.

Methods

Electrophysiologic study (EPS) was performed in 994 patients for a pre-excitation syndrome. AP location was determined on a 12 lead ECG during atrial pacing at maximal preexcitation and confirmed at intracardiac EPS in 494 patients.

Results

AP location was classified as anteroseptal (AS)(96), right lateral (RL)(54), posteroseptal (PS)(459), left lateral (LL)(363), nodoventricular (NV)(22).Patients with ASAP or RLAP were younger than patients with another AP location. Poorly-tolerated arrhythmias were more frequent in patients with LLAP than in other patients (0.009 for ASAP, 0.0037 for RLAP, <0.0001 for PSAP).Maximal rate conducted over AP was significantly slower in patients with ASAP and RLAP than in other patients. Malignant forms at EPS were more frequent in patients with LLAP than in patients with ASAP (0.002) or PSAP (0.001).Similar data were noted when AP location was confirmed at intracardiac EPS. Among untreated patients, poorly-tolerated arrhythmia occurred in patients with LLAP (3) or PSAP (6). Failures of ablation were more frequent for AS or RL AP than for LL or PS AP.

Conclusions

AS and RLAP location in pre-excitation syndrome was more frequent in young patients. Maximal rate conducted over AP was lower than in other locations. Absence of poorly-tolerated arrhythmias during follow-up and higher risk of ablation failure should be taken into account for indications of AP ablation in children with few symptoms.  相似文献   

5.
Dual atrioventricular (AV) nodal pathway physiology is described as two different wave fronts that propagate from the atria to the His bundle: one with a longer effective refractory period [fast pathway (FP)] and a second with a shorter effective refractory period [slow pathway (SP)]. By using His electrogram alternance, we have developed a mathematical model of AV conduction that incorporates dual AV nodal pathway physiology. Experiments were performed on five rabbit atrial-AV nodal preparations to develop and test the presented model. His electrogram alternances from the inferior margin of the His bundle were used to identify fast and slow wave front propagations. The ability to predict AV conduction time and the interaction between FP and SP wave fronts have been analyzed during regular and irregular atrial rhythms (e.g., atrial fibrillation). In addition, the role of dual AV nodal pathway wave fronts in the generation of Wenckebach periodicities has been illustrated. Finally, AV node ablative modifications have been evaluated. The model accurately reproduced interactions between FP and SP during regular and irregular atrial pacing protocols. In all experiments, specificity and sensitivity higher than 85% were obtained in the prediction of the pathway responsible for conduction. It has been shown that, during atrial fibrillation, the SP ablation significantly increased the mean HH interval (204 ± 39 vs. 274 ± 50 ms, P < 0.05), whereas FP ablation did not produce significant slowing of ventricular rate. The presented mathematical model can help in understanding some of the intriguing AV node mechanisms and should be considered as a step forward in the studies of AV nodal conduction.  相似文献   

6.

Introduction

The risk of developing conduction disturbances after coronary bypass grafting (CABG) or valvular surgery has been well established in previous studies, leading to permanent pacemaker implantation in about 2% to 3% of patients, and in 10% of patients undergoing repeat cardiac surgery. We sought to determine the incidence, features and predictors of conduction disorders in the immediate post-operative period of patients subjected to open-heart surgery, and the need for permanent pacemaker implantation.

Material and Method

We prospectively studied 374 consecutive patients who underwent open-heart surgery in our institution: coronary artery bypass (CABG) (n=128), Mitral valve replacement(MVR)(n=18), aortic valve replacement(AVR) (n=21), MVR and AVR(n=56), repair of ventricular septal defect (VSD) (n=51), repair of tetralogy of Fallot (TOF) (n=57),CABG and valvular surgery (n=6), others (n=37).

Results

Among 374 patients included in our study (mean age 34.46±25.68; 146 males), 192 developed new conduction disorders: symptomatic sinus bradycardia in 8%, atrial fibrillation with slow ventricular response (AF) in 4.5%, first-degree atrioventricular block (AVB)in 6.4%, second-degree AVB in 0.3%, third-degree AVB in 7%, new right bundle branch block (RBBB) in 33%, and new left bundle branch block (LBBB) in 2.1%. In 5.6% patients, a permanent pacemaker was implanted, 47.6% of them underwent valvular surgery. In 44.1% of patients the conduction defects occurred in the first 48 hr. after surgery. In CABG group, 29.7% of patients developed new conduction disturbances; the most common of them was symptomatic sinus bradycardia. After valvular surgery 44.2% of patients developed conduction disturbances, of those the most common was atrial fibrillation with slow ventricular response . After VSD and TOF repair, the most common conduction disturbance was new RBBB. Perioperative myocardial infarction (MI) occurred in 1.9% of patients. The occurrence conduction disturbance was compared with patient age, sex, occurrence of perioperative MI, ejection fraction (EF), postoperative use of ß-adernergic receptor blocking agents and digitalis and type of cardiac surgery. By regression analysis there was a correlation between type of surgery and new conduction defects, being significant for CABG and TOF repair. Only the occurrence of perioperative MI was related to PPM implantation.

Conclusion

Irreversible AVB requiring a PPM is an uncommon complication after open-heart surgery. Peri-operative MI is a risk factor.  相似文献   

7.

Background

Normal heart ventricular arrhythmia occurring during pregnancy has been previously described. Whilst there are established reports of catheter ablation to treat supraventricular arrhythmia during pregnancy, there are no reports of ablation to treat ventricular tachycardia.

Case

We present the case of a 36 year old women, 31 weeks into an otherwise uncomplicated pregnancy, experiencing significant, troublesome and drug refractory tachycardia emanating from the right ventricular outflow tract.

Conclusion

We describe a successful radio frequency ablation in the third trimester of pregnancy.  相似文献   

8.

Introduction

Radio-frequency catheter ablation (RFCA) using Joule heat has two fundamental weaknesses: the limited depth of treatment and the risk of thrombus formation. In contrast, focused shock wave (SW) therapy could damage tissues at arbitrary depths without heat generation. Thus, we aimed to develop a SW catheter ablation (SWCA) system that could compensate for the weaknesses of RFCA therapy.

Methods and Results

We developed a SWCA system where the SW generated by a Q-switched Holmium: yttrium aluminum garnet (YAG) laser beam was reflected by a reflector attached to 14-Fr catheter tip and then was converged onto the focus. We examined the feasibility of our system on pigs in vivo. When applied using the epicardial approach, the SWCA caused persistent spheroidal lesions with mild superficial injury than the RFCA. The lesions were created to a depth based on the focal length (2.0 mm) [2.36 ± 0.45 (SD) mm immediately after procedure, n = 16]. When applied to the atrioventricular (AV) node using the endocardial approach, the SWCA caused junctional escape rhythms in 2 pigs and AV block in 12 pigs (complete AV block in 9) in acute phase (n = 14). Nine of the 14 pigs survived with pacemakers for the long-term study, and the AV block persisted for 12.6 ± 3.9 (SD) days in all surviving pigs. Histological examination showed AV nodal cell body atrophy in the acute phase and fibrotic lesions in the chronic phase. Importantly, no acute or chronic fatal complications were noted.

Conclusions

Our novel SWCA system could be a promising modality as a non-thermal ablation method to compensate for the weaknesses of RFCA therapy. However, further research and development will be necessary as the current prototype still exhibited the presence of micro-thrombus formation in the animal studies.  相似文献   

9.

Background and objectives

While radiofrequency ablation catheter ablation of accessory pathways is generally safe and effective, anatomic variants can cause considerable challenges in effecting cure. Our objective was to use an unusual case where coronary sinus was absent and arterial venous fistula was present and a left-sided pathway required mapping and ablation to develop a framework to approach difficult cases.

Method

A detailed literature search and review of contemporary cardiac embryology was undertaken to attempt and to explain a common developmental anomaly. Adjunctive approaches during the ablation procedure, including intracardiac ultrasound, were used to guide mapping and ablation despite the lack of coronary sinus access.

Results

The accessory pathway was successfully ablated using a transseptal approach and intracardiac ultrasound guided mapping of the mitral annulus. A potential common mechanism to explain the apparently disparate anatomic variants in this patient was formulated.

Conclusions

Cardiac conduction development is complex and accessory pathway conduction may occur in the setting of arteriovenous anomalies thus providing insights as to the cause of WPW syndrome. Successful mapping and targeted ablation of left-sided pathways may be accomplished even when coronary sinus access is not possible.  相似文献   

10.

Background

Cavotricuspid isthmus (CTI) anatomy is associated with a great inter-individual variability. The aim of this study was to compare the magnetic 8-mm tip catheter versus the novel 3.5-mm magnetic irrigated tip catheter in achieving bidirectional right atrial isthmus block and to evaluate the impact of the underlying CTI anatomy on success rate.

Methods

A detailed remote controlled 3-dimensional electroanatomic (3D EA) right atrial reconstruction was performed using the magnetic navigation system with special emphasis to the CTI. CTI anatomy was evaluated utilizing the 3D EA map and classified into (A) simple (flat), (B) complex (pouch-like recess or concave shape) or (C) highly complex (pouch-like recess and concave shape). Patients were treated either with the magnetic 8-mm tip catheter (group I) or the open irrigated magnetic 3.5-mm tip catheter (group II). Primary endpoint was defined as acute bidirectional CTI block utilizing exclusively the remote controlled magnetic navigation system. Secondary endpoint was any procedure related complication and procedure time.

Results

In group I (n=10, 10 males, mean age: 65 ± 9 years) the primary endpoint was achieved in 80% (8/10 pts) requiring a median (Q1; Q3) RF application time of 37.1 min (22.8; 71.5) and a median (Q1;Q3) cumulative energy (CE) of 70.68 kJ (kilo Joule). (10.76;40.59). In group II (n=13, 10 males, mean age: 60 ± 7 years) the primary endpoint was achieved in 92 % (12/13) with a median (Q1; Q3) RF application time of 21.9 min (13.0; 27.0; p value=0.036) and a CE of 33.54 KJ (26.59; 49.22; p value=0.015). Variable CTI anatomy was identified for group I (type A: n=5 pts, type B: n=5 pts, type C: n=0 pts) and group for II (type A: n=4 pts, type B: n=7 pts, type C: n=2 pts). In group I magnetic ablation failure was associated with type B CTI anatomy (n=2 pts) and in group II with type C CTI (n=1). No procedure related complications were observed.

Conclusion

Remote controlled catheter ablation of typical atrial flutter using the magnetic navigation system appears to be safe and feasible. CTI anatomy determines remote controlled magnetic ablation success. Use of the magnetic 3.5 mm irrigated tip catheter should be considered in patients with complex CTI anatomy.  相似文献   

11.
The electrophysiological properties of atrioventricular (AV) nodal dual pathways have traditionally been investigated with premature stimuli delivered with right atrial pacing. However, little is known about the functional characteristics of AV nodal inputs outside of this context. Superfused rabbit triangle of Koch preparations (n = 8) and Langendorff-perfused hearts (n = 10) were paced throughout the triangle of Koch and mapped electrically and optically for activation pattern, electrogram and optical action potential morphologies, stimulation thresholds, and stimulus-His (S-H) intervals. Optical mapping and changes in His electrogram morphology were used to confirm the activation pathway. Pacing stimuli >or=2 mm above the tricuspid valve caused fast-pathway activation of the AV node and His with a threshold of 2.4 +/- 1.6 mA. An area directly below the coronary sinus had high thresholds (8.6 +/- 1.4 mA) that also resulted in fast-pathway excitation (P < 0.001). S-H intervals (81 +/- 19 ms) for fast-pathway activation remained constant throughout the triangle of Koch, reflecting the AV delay. Stimuli applied <2 mm from the tricuspid valve resulted in slow pathway (SP) excitation or direct His excitation (4.4 +/- 2.2 mA threshold; P < 0.001 compared with fast pathway). For SP/His pacing, S-H intervals showed a strong dependence on the distance from the His electrode and were significantly lower than S-H intervals for fast-pathway activation. SP/His pacing also displayed characteristic changes in His electrogram morphology. In conclusion, optical maps and S-H intervals for SP/His activation suggest that AV conduction via SP bypasses the compact AV node via the lower nodal bundle, which may be utilized to achieve long-term ventricular synchronization.  相似文献   

12.

Background

Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear.

Objective

Comparing the risk for SCE depending on exchanges of catheters (ExCath) over a single transseptal sheath.

Methods

88 Patients undergoing pulmonary vein isolation (PVI) only ablation using either single-tip or balloon-based technique underwent pre- and post-ablation cerebral MRI. Ablations were either performed with double transseptal access and without exchanging catheters over the transseptal sheaths (group 1: no ExCath) or after a single transseptal access and exchanges of therapeutic and diagnostic catheters (group 2: ExCath). Differences in regard to SCE rates were analyzed. Multivariate analysis was performed to identify factors related to the risk for SCE.

Results

Included patients underwent PVI using single tip irrigated radiofrequency in 41, endoscopic laser balloon in 27 and cryoballoon in 20 cases. Overall SCE were identified in 23 (26%) patients. In group 1 (no ExCath; N=46) 6 patients (13%) and in group 2 (N=42) 17 patients (40%) had documented SCE (p=0.007). The applied ablation technology did not affect SCE rate. In multivariate analysis age (OR 1.1, p=0.03) and catheter exchanges over a single transseptal sheath (OR 12.1, p=0.007) were the only independent predictors of a higher risk for SCE.

Conclusions

Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.  相似文献   

13.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

14.

Aims

Syncope is defined as temporary loss of consciousness and postural tone resulting from an abrupt transient decrease in cerebral blood flow. The present work aimed at determining how diagnostic tests are used in the evaluation of pediatric syncope at a tertiary pediatric referral center and to report on the utility and the yield of these tests.

Settings and Design

Retrospective study conducted at a tertiary referral arrhythmolology service

Methods and Material

The clinical charts of 234 pediatric patients presenting with a primary complaint of syncope with an average age of 7.48 ± 3.82(3.5-16) years were reviewed by the investigators.

Statistical analysis used

Statistical Package of social science (SPSS) version 9,0 was used for analysis of data.

Results

The commonest trigger for syncope in the study population was early following exercise (n=65) and the commonest prodrome was palpitation, noted in 25 patients. A murmur was present in 19 of our patients (8.3%) while 10.7% (n=25) had abnormal ECGs. Of the 106 echocardiograms done, 14 (13.2%) were abnormal. Only two of them were missed by ECG. All patients were offered ambulatory 24 hour ECG. One patient with sick sinus syndrome was diagnosed only with Holter.

Conclusions

Clues to the presence of cardiac syncope may include acute onset of syncope, frequent episodes, low difference between blood pressure readings in supine and erect positions (after standing for 2 minutes) and most importantly an abnormal 12 lead ECG. Transthoracic echo and Holter monitoring have low yield in pediatric syncope.  相似文献   

15.

Background

Galectin-3 (Gal-3) is an emerging biomarker in heart failure that is involved in fibrosis and inflammation. However, its potential value as a prognostic marker in atrial fibrillation (AF) is unknown. The aim of this study was to assess the impact of AF catheter ablation on Gal-3 and evaluate its prognostic impact for predicting rhythm outcome after catheter ablation.

Methods

Gal-3 was measured at baseline and after 6 months using specific ELISA. AF recurrences were defined as any atrial arrhythmia lasting longer than 30 sec within 6 months after ablation.

Results

In 105 AF patients (65% males, age 62±9 years, 52% paroxysmal AF) undergoing catheter ablation, Gal-3 was measured at baseline and after 6 months and compared with an AF-free control cohort (n=14, 50 % males, age 58±11 years). Gal-3 was higher in AF patients compared with AF-free controls (7.8±2.9 vs. 5.8±1.8, ng/mL, p=0.013). However, on multivariable analysis, BMI (p=0.007) but not AF (p=0.068) was associated with Gal-3. In the AF cohort, on univariable analysis higher Gal-3 levels were associated with female gender (p=0.028), higher BMI (p=0.005) and both CHADS2 (p=0.008) and CHA2DS2-VASC (p=0.016) scores, however, on multivariable analysis only BMI remained significantly associated with baseline Gal-3 (p=0.016). Gal-3 was similar 6 months after AF catheter ablation and was not associated with sinus rhythm maintenance.

Conclusions

Although galectin-3 levels are higher in AF patients, this is driven by cardiometabolic co-morbidities and not heart rhythm. Gal-3 is not useful for predicting rhythm outcome of catheter ablation.  相似文献   

16.

Aims

Holter monitoring (HM) has been established as one of the most effective noninvasive clinical tools in the diagnosis, assessment and risk stratification of cardiac patients. However, studies in the pediatric age group are limited. The present work aims at determining the value of HM in the diagnosis and management of children.

Settings and Design

Retrospective study conducted at a tertiary referral arrhythmolology service.

Methods and Material

Holter records of 1319 pediatric patients (54.1% males and 45.9% females) were reviewed. Their average age was 6.7± 4.1 years (5 days-16 years). Indications for which Holter monitoring was done were analysed as well as all the abnormalities diagnosed and factors that may increase Holter yield.

Statistical analysis used

Statistical Package of social science (SPSS) version 9,0 was used for analysis of data.

Results

The most common indications were palpitations (19.8%), syncope (17.8%), cardiomyopathy (12.6%), chest pain (10%), evaluation of antiarrhythmic therapy (6.8%), postoperative assessment (2.6%) and complete AV Block (2.4%). A sum of 141 Holter recordings were found abnormal with a total diagnostic yield of 10.7%. The highest contribution to diagnosis was in postoperative assessment (32.4%) and in cardiomyopathy (19.9%) where the most common abnormalities were frequent supraventricular / ventricular premature beats, supraventricular tachycardia, ventricular tachycardia and AV block. Diagnostic yield was low in patients with palpitations (5.7%) and syncope (0.4%). An abnormal ECG was significantly associated with a higher diagnostic yield (p=0.0001). None of the children with chest pain had abnormal Holter recordings.

Conclusions

HM has an extremely valuable role in the assessment of high risk patients (postoperative and cardiomyopathy). However in children with palpitations, syncope and chest pain HM has a low yield. In this group of patients an abnormal ECG is more likely to be associated with abnormal Holter recordings.  相似文献   

17.

Background

The Purkinje fiber system has recently been implicated as an important driver of the rapid activation rate during long duration ventricular fibrillation (VF>2 minutes). The goal of this study is to determine whether this activity propagates to or occurs in the proximal specialized conduction system during VF as well.

Methods and Results

An 8×8 array with 300 µm spaced electrodes was placed over the His bundles of isolated, perfused rabbit hearts (n = 12). Ventricular myocardial (VM) and His activations were differentiated by calculating Laplacian recordings from unipolar signals. Activation rates of the VM and His bundle were compared and the His bundle conduction velocity was measured during perfused VF followed by 8 minutes of unperfused VF. During perfused VF the average VM activation rate of 11.04 activations/sec was significantly higher than the His bundle activation rate of 6.88 activations/sec (p<0.05). However from 3–8 minutes of unperfused VF the His system activation rate (6.16, 5.53, 5.14, 5.22, 6.00, and 4.62 activations/sec significantly faster than the rate of the VM (4.67, 3.63, 2.94, 2.24, 3.45, and 2.31 activations/sec) (p<0.05). The conduction velocity of the His system immediately decreased to 94% of the sinus rate during perfused VF then gradually decreased to 67% of sinus rhythm conduction at 8 minutes of unperfused VF.

Conclusion

During prolonged VF the activation rate of the His bundle is faster than that of the VM. This suggests that the proximal conduction system, like the distal Purkinje system, may be an important driver during long duration VF and may be a target for interventional therapy.  相似文献   

18.

Introduction

A patient with D-TGA and surgical repair (Mustard''s procedure) presented with appropriate ICD shocks due to monomorphic ventricular tachycardia, refractory to antiarrhythmic medications.

Methods and Results

The patient underwent an electrophysiological study and catheter ablation for the VT. Substrate and pace mapping techniques, with the help of an electroanatomical mapping system, was used to localize and ablate the tachycardia successfully.

Conclusions

In patients with D-TGA and Mustard''s repair, scar tissue resulting from VSD repair can act as a substrate for recurrent VT. Catheter ablation of VT is useful in management of VT that occurs despite antiarrhythmic therapy and/or when it is unstable.  相似文献   

19.

Background

Accumulating evidences have suggested that percutaneous cryoablation could be a valuable alternative ablation therapy for HCC but there has been no large cohort-based analysis on its long-term outcomes.

Methods

A series of 866 patients with Child-Pugh class A-B cirrhosis and HCC within Milan criteria who underwent percutaneous cryoablation was long-term followed. The safety, efficacy, 5-year survival, and prognostic factors of percutaneous cryoablation in the treatment of HCC were analyzed.

Results

A total of 1197 HCC lesions were ablated with 1401 cryoablation sessions. Complete response (CR) was achieved in 1163 (97.2%) lesions and 832 (96.1%) patients with 34 (2.8%) major complications, but no treatment-related mortality. After a median of 30.9 months follow-up, 502 (60.3%) patients who achieved CR developed different types of recurrence. The cumulative local tumor recurrence rate was 24.2% at 5-years. Multiple tumor lesions, tumor size > 3 cm, and repeated ablation of same lesion were independent risk factors associated with local recurrence. The 5-year overall survival (OS) rates were 59.5%. Age < 36 years, HCC family history, baseline hepatitis B virus DNA >106 copies/ml, and three HCC lesions were independently and significantly negative predictors to the post-cryoablation OS.

Conclusions

Percutaneous cryoablation is an effective therapy for patients with HCC within Milan criteria, with comparable efficacy, safety and long-term survival to the reported outcomes of radiofrequency ablation.  相似文献   

20.

Background

Electrical storm (ES) due to drug refractory ventricular tachycardia (VT) occurring within first few weeks of acute myocardial infarction (MI) has poor prognosis. Catheter ablation has been proposed for treating VT occurring late after MI, but there is limited data on catheter ablation in VT within first few weeks of MI.

Methods and Results

Five patients (4 males, mean age 54.2±12.11 years) between June 2008 to July 2012, referred for VT presenting as ES refractory to antiarrhythmic drugs in the early post infarction period (six weeks following MI) despite revascularization. Three patients had anterior wall MI and two inferior wall MI with left ventricular ejection fraction ranging from 26 to 35%.All underwent catheter ablation within 48 hours of being in VT except one who presented late. Clinical VT was induced in all five patients. Total number of VTs induced were 11 (2.2±1.09 per patient). Two patients needed epicardial ablation via pericardial puncture. Though acute success was 100%, one patient had recurrence of clinical VT the next day of procedure.One patient succumbed to sepsis with multiple organ failure. The remaining four patients are doing well without further clinical recurrence of VT over a period of 3.7 years of follow-up.

Conclusion

Catheter ablation can be a useful adjunctive therapy for patients with recurrent VT in the early post infarction period. This procedure appears to be safe with acceptable success rate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏