首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 627 毫秒
1.
Experimental studies were done in a laboratory scale Anaerobic Rotating Biological Contactor (RBC), for treatment of Synthetic sago wastewater. This paper describes the development and laboratory testing of an Anaerobic RBC process that couples the advantages of the fixed film horizontal flow RBC process with the high strength, starch degradation capabilities of anaerobic systems. The reactor was operated at ambient temperature and was subjected to organic and hydraulic loading rates. The reactor performance with respect to Chemical Oxygen Demand (COD) removal, alkalinity, volatile acids at each stage and biogas production were evaluated. The Anaerobic RBC reactor liquid volume is 70 litres and total disc surface area is 4.45 m2. The reactor was operated with about 100% of the disc area submerged and with a rotational speed held constant at 9?rev/min. The synthetic sago wastewater was started with a COD value of 1087?mg/l at a hydraulic retention time(HRT) of 42?h and it was varied till maximum COD of 9522?mg/l. From the present study, the optimum COD load was found to be 6860?mg/l with a COD removal efficiency of 97.2%.With this optimum COD load, hydraulic loading rate(HLR) study was done at 24?h to 48?h HRT. COD removal efficiencies at hydraulic loading rates were compared with the work of Subrahmanyam &; Sastry (1988). From the present study, the proportionality coefficient was found to be 1.18 with process efficiencies at different hydraulic loading rates.  相似文献   

2.
A lab-scale investigation was conducted to examine the effectiveness of a multi-fed upflow anaerobic filter process for the methane production from a rice winery effluent at ambient temperatures. The experiment was carried in two identical 3.0-l upflow filters, a single-fed reactor and a multi-fed reactor. The results showed that the multi-fed reactor, operated at the ambient temperatures of 19–27 °C and influent chemical oxygen demand (COD) of 8.34–25.76 g/l, could remove over 82% of COD even at an organic loading rate (OLR) of 37.68 g-COD/l d and a short hydraulic retention time (HRT) of 8 h. This reactor produced biogas with a methane yield of 0.30–0.35 l-CH4/g-CODremoved. The multi-fed upflow anaerobic filter was proved to be more efficient than the single-fed reactor in terms of COD removal efficiency and stability against hydraulic loading shocks. A linear-regression model with influent COD concentration and HRT terms adequately described the multi-fed upflow anaerobic filter system for the treatment of rice winery wastewater at ambient temperatures.  相似文献   

3.
This paper examines the effect of organic loading rate on the removal efficiency of COD and TOC anaerobic thermophilic fluidized bed reactor (AFBR) in the treatment of cutting-oil wastewater at different hydraulic retention time (HRT) conditions. The essays are development at laboratory scale using a porous support medium. The AFBR reactor was subjected to a programme of steady-state operation over a range of hydraulic retention times, HRTs, in the range 12-2h and organic loading rates, OLRs, between 11.9 and 51.3kgCOD/m(3)d. The highest efficiency was 95.9% for an OLR of 13kgCOD/m(3)d and HRT of 11h. Over an operating period of 92 days, an OLR of 51.3kgCOD/m(3)d was achieved with 67.1% COD removal efficiency (71.3% TOC) in the experimental AFBR reactor. Although the level of biogas generation was not high, the anaerobic fluidized bed technology provided significant advantages over the conventional physico-chemical treatment applied in the factory. The effluent had a better quality (lower organic loading) and it was possible to reuse it in different applications in the factory (e.g., irrigation of gardens). The biological treatment did not lead to the generation of oily sludge, which is considered as hazardous waste by legislation. Furthermore, a continuous stream is produced and this reduced the impact of large flows discharged 4-5 times per week to the urban collector and MWWTP (municipal wastewater treatment plant).  相似文献   

4.
Anaerobic digestion of wastewater from a distillery industry having very high COD (1,10,000-1,90,000 mg/L) and BOD (50,000-60,000 mg/L) was studied in a continuously fed, up flow fixed film column reactor using different support materials such as charcoal, coconut coir and nylon fibers under varying hydraulic retention time and organic loading rates. The seed consortium was prepared by enrichment with distillery spent wash in a conventional type reactor having working capacity of 3 L and was used for charging the anaerobic column reactor. Amongst the various support materials studied the reactor having coconut coir could treat distillery spent wash at 8d hydraulic retention time with organic loading rate of 23.25 kg COD m(-3)d(-1) leading to 64% COD reduction with biogas production of 7.2 m3 m(-3)d(-1) having high methane yield without any pretreatment or neutralization of the distillery spent wash. This study indicates fixed film biomethanation of distillery spent wash using coconut coir as the support material appears to be a cost effective and promising technology for mitigating the problems caused by distillery effluent.  相似文献   

5.
The ability of an anaerobic hybrid reactor, treating coffee wastewater, to achieve a quick start-up was tested at pilot scale. The unacclimatized seed sludge used showed a low specific methanogenic activity of 26.47 g CH4 as chemical oxygen demand (COD)/kg volatile suspended solids (VSS) x day. This strongly limited the reactor performance. After a few days of operation, a COD removal of 77.2% was obtained at an organic loading rate (OLR) of 1.89 kg COD/m3 x day and a hydraulic retention time (HRT) of 22 h. However, suddenly increasing OLR above 2.4 kg COD/m3 x day resulted in a deterioration in treatment efficiency. The reactor recovered from shock loads after shutdowns of 1 week. The hybrid design of the anaerobic reactor prevented the biomass from washing-out but gas clogging in the packing material was also observed. Wide variations in wastewater strength and flow rates prevented stable reactor operation in the short period of the study.  相似文献   

6.
An acetic-acid-based synthetic wastewater of different organic concentrations was successfully treated at 35 degrees C in anaerobic downflow fixed-film reactors operated at high organic loading rates and short hydraulic retention times (HRTs). Substrate removal and methane production rates close to theoretical values of complete volumetric chemical oxygen demand (COD) removal and maximum methane conversion were obtained. A high concentration of biofilm biomass was retained in the reactor. Steady-state biofilm concentration increased with increased organic loading rate and decreased HRTs, reaching a maximum of 8.3 kg VFS/m(3) at a loading rate of 17 kg COD/m(3) day. Biofilm substrate utilization rates of up to 1.6 kg COD/kg VFS day were achieved. Soluble COD utilization rates at various COD concentrations can be described by half-order reaction kinetics.  相似文献   

7.
Challenge of psychrophilic anaerobic wastewater treatment   总被引:45,自引:0,他引:45  
Psychrophilic anaerobic treatment is an attractive option for wastewaters that are discharged at moderate to low temperature. The expanded granular sludge bed (EGSB) reactor has been shown to be a feasible system for anaerobic treatment of mainly soluble and pre-acidified wastewater at temperatures of 5--10 degrees C. An organic loading rate (OLR) of 10--12 kg chemical oxygen demand (COD) per cubic meter reactor per day can be achieved at 10--12 degrees C with a removal efficiency of 90%. Further improvement might be obtained by a two-module system in series. Stabile methanogenesis was observed at temperatures as low as 4--5 degrees C. The specific activity of the mesophilic granular sludge was improved under psychrophilic conditions, which indicates that there was growth and enrichment of methanogens and acetogens in the anaerobic system. Anaerobic sewage treatment is a real challenge in moderate climates because sewage belongs to the 'complex' wastewater category and contains a high fraction of particulate COD. A two-step system consisting of either an anaerobic up-flow sludge bed (UASB) reactor combined with an EGSB reactor or an anaerobic filter (AF) combined with an anaerobic hybrid reactor (AH) is successful for anaerobic treatment of sewage at 13 degrees C with a total COD removal efficiency of 50% and 70%, respectively.  相似文献   

8.
Studies were carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater were found to be very high with low biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and startup of the reactor was carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor was studied at different organic loading rates (OLR) and it was found that the optimum OLR was 10 kg COD/m(3)/day. The wastewater under investigation, which had a considerable quantity of SS, was treated anaerobically without any pretreatment. COD and BOD of the reactor outlet wastewater were monitored and at steady state and optimum OLR 60-70% of COD and 80-90% of BOD were removed. The reactor was subjected to organic shock loads at two different OLR and the reaction could withstand the shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS.  相似文献   

9.
Shao X  Peng D  Teng Z  Ju X 《Bioresource technology》2008,99(8):3182-3186
Brewery wastewater was treated in a pilot-scale anaerobic sequencing batch reactor (ASBR) in which a floating cover(@) was employed. Long time experiments showed that the reactor worked stably and effectively for COD removal and gas production. When the organic loading rate was controlled between 1.5 kg COD/m3 d and 5.0 kg COD/m(3)d, and hydraulic retention time one day, COD removal efficiency could reach more than 90%. Sludge granulation was achieved in the reactor in approximately 60 days, which is much less than the granulation time ever reported. In addition, high specific methanogenic activity (SMA) for formate was observed. The study suggests that the ASBR technology is a potential alternative for brewery wastewater treatment.  相似文献   

10.
In this study, performance of a lab-scale hybrid up-flow anaerobic sludge blanket (UASB) reactor, treating a chemical synthesis-based pharmaceutical wastewater, was evaluated under different operating conditions. This study consisted of two experimental stages: first, acclimation to the pharmaceutical wastewater and second, determination of maximum loading capacity of the hybrid UASB reactor. Initially, the carbon source in the reactor feed came entirely from glucose, applied at an organic loading rate (OLR) 1 kg COD/m(3) d. The OLR was gradually step increased to 3 kg COD/m(3) d at which point the feed to the hybrid UASB reactor was progressively modified by introducing the pharmaceutical wastewater in blends with glucose, so that the wastewater contributed approximately 10%, 30%, 70%, and ultimately, 100% of the carbon (COD) to be treated. At the acclimation OLR of 3 kg COD/m(3) d the hydraulic retention time (HRT) was 2 days. During this period of feed modification, the COD removal efficiencies of the anaerobic reactor were 99%, 96%, 91% and 85%, and specific methanogenic activities (SMA) were measured as 240, 230, 205 and 231 ml CH(4)/g TVS d, respectively. Following the acclimation period, the hybrid UASB reactor was fed with 100% (w/v) pharmaceutical wastewater up to an OLR of 9 kg COD/m(3) d in order to determine the maximum loading capacity achievable before reactor failure. At this OLR, the COD removal efficiency was 28%, and the SMA was measured as 170 ml CH(4)/g TVS d. The hybrid UASB reactor was found to be far more effective at an OLR of 8 kg COD/m(3) d with a COD removal efficiency of 72%. At this point, SMA value was 200 ml CH(4)/g TVS d. It was concluded that the hybrid UASB reactor could be a suitable alternative for the treatment of chemical synthesis-based pharmaceutical wastewater.  相似文献   

11.
Two 90 L anaerobic baffled reactors were used to study the granulation of sludge and the effect of the organic loading rate and NaHCO3/COD ratios on reactor performance. Furthermore, it was determined whether an anaerobic baffled reactor would promote phase separation and if additive of bentonite or granular active carbon was capable of enhancing granule formation. In order to minimize feed variations, and have a totally biodegradable substrate, a synthetic sucrose substrate was used. Granulation was achieved in both reactors within 75 days. However, the granules from the granular active carbon amended reactor appeared earlier and were larger and more compact. The reactors were maintained at a hydraulic retention time of 20 h during performance study stage. The results showed that when organic loading rate were changed from 2.15 to 6.29 kg COD m(-3)day(-1), chemical oxygen demand (COD) removal was not decreased (91-93%), but a slight increase in effluent COD was observed. It was found that the COD removals were generally good (87-92%) and had not obviously change with the decreasing NaHCO3/COD ratios. From the bacterial distribution and the concentration of volatile fatty acids in four compartments, it was concluded that a separation of phases occurred within the anaerobic baffled reactors.  相似文献   

12.
【目的】为开发高效的高浓度木质纤维素燃料乙醇蒸馏废水厌氧处理及资源化利用工艺,以活性炭为载体,在实验室规模上对高温厌氧流化床反应器处理木质纤维素燃料乙醇蒸馏废水进行研究。【方法】反应器经65 d梯度驯化后启动,对工艺参数进行一系列优化,并通过基于16S rRNA基因的分子生态学技术分析厌氧污泥中的优势菌群。【结果】实验获得了最优的反应条件和处理效果:厌氧流化床反应器(Anaerobic fluidized bed reactor,AFBR)在温度55±1°C、有机负荷率(OLR)13.8 g COD/(L·d)及水力停留时间(HRT)48 h操作时,COD去除率达到90%以上,同时甲烷产率达到290 mL/g COD;菌群鉴定分析结果显示高温厌氧活性污泥中Clostridia所占比例最大,产甲烷菌属以Methanoculleus和Methanosarcina为主,其它功能菌群主要为Alphaproteobacteria等。【结论】AFBR反应器可高效降解木质纤维素燃料乙醇蒸馏废水并产生生物能源甲烷,其反应体系内微生物种类丰富。  相似文献   

13.
Summary A stepped-loading start-up regime utilising volatile fatty acids as carbon and energy sources was applied to a downflow anaerobic fixed-film reactor operated at 37°C. A steadystate was attained with over 90% COD reduction at an organic loading rate of 6.1 Kg COD/m3·day. A complex wastewater coming from a citrus processing plant was then used to test the feasibility of feeding changes as well as the stability of the reactor performance. A final COD reduction of 60% was achieved with hydraulic retention times down to 1.5 days.  相似文献   

14.
In the present study, an attempt has been made to treat dairy wastewater entirely via anaerobic treatment over a period of 215 days, using two-stage Hybrid Upflow Anaerobic Sludge Blanket (HUASB) reactors, which offer the advantages associated both with fixed film and upflow sludge blanket treatments. A HUASB with polyurethane foam cubes was used for stage I, and a HUASB utilizing PVC-cut rings was used for stage II. The output from stage I was used as the input for stage II. The two-stage reactor was operated at an organic loading rate that varied from 10.7 to 21.4 kg COD m3/d for a period of 215 days, including the start-up period. The ideal organic loading rate for the two-stage reactor was 19.2 kg COD/m3/d. A further 21.4 kg COD m3/d increase in the organic loading rate resulted in the souring of the reactor function in stage I, which consequently reduced the overall reactor performance. Combined COD removal during the stable operation period (10.7 to 19.2 kg COD m3/d) occurred in a range between 97 and 99%. The methane content in the biogas varied from 65 to 70% in stage I, and from 63 to 66% in stage II. The two-stage anaerobic treatment using HUASB with PUF and PVC described in this work is expected to constitute a better alternative for the complete treatment of dairy wastewater than high-rate anaerobic, anaerobic/aerobic, and two-phase anaerobic treatment methods.  相似文献   

15.
Studies are carried out on the treatment of wastewater from a bulk drug industry using an anaerobic fixed film reactor (AFFR) designed and fabricated in the laboratory. The chemical oxygen demand (COD) and total dissolved solids (TDS) of the wastewater are found to be very high with low Biochemical oxygen demand (BOD) to COD ratio and high total suspended solid (TSS) concentration. Acclimatization of seed consortia and start up of the reactor is carried out by directly using the wastewater, which resulted in reducing the period of startup to 30 days. The reactor is studied at different organic loading rates (OLR) and it is found that the optimum OLR is 10 kg COD/m3/day. The wastewater under investigation, which is having considerable quantity of SS, is treated anaerobically without any pretreatment. The COD and BOD of the reactor outlet wastewater are monitored and reduction at steady state and optimum OLR is observed to be 60-70% of COD and 80-90% of BOD. The reactor is subjected to organic shock loads at two different OLR and it is observed that the reactor could withstand shocks and performance could be restored to normalcy at that OLR. The results obtained indicated that AFFR could be used efficiently for the treatment of wastewater from a bulk drug industry having high COD, TDS and TSS.  相似文献   

16.
Results are presented from a pilot scale (4·3 m3) upflow anaerobic filter for the treatment of the wastewater from ice-cream manufacture. The reactor was completely mixed by gas production but the solids or sludge held within the reactor were shown to be affected by the liquid velocities. The reactor was subject to a number of organic and hydraulic shocks and this reduced the consistency of COD removal. Daily loading rates varied from 0 to 18 kg COD/m3/day but with an average load of 5·5 kg/m3/day the mean COD removal was 70%. This was compared with previous work and shown to be a typical performance for an anaerobic filter. Alkalinity and carboxylic acid data are also presented and were within the normal, stable, operating range. Previous research on the anaerobic treatment of industrial effluents has shown alkalinity to be the most important factor controlling reliability.  相似文献   

17.
A 450-m(3) multiplate anaerobic reactor (MPAR) has been started-up in April 1992 for treating wastewater (whey permeate and domestic wastewater) at the Nutrinor (Lactel) cheese factory in Chambord (Québec, Canada). The MPAR consists of four superimposed sections. The liquid flows upwards from one section to the next, while the gas is collected below each plate and evacuated through side-outlets. The wastewater is concurrently distributed at the bottom of the first, second, and third sections, as 50%, 33%, and 17% of the total influent stream, respectively. Granular anaerobic sludge at an initial concentration of 30 kg of volatile suspended solids (VSS) per cubic meter of reactor liquid volume was used to inoculate the reactor. Under normal operation of the factory, the chemical oxygen demand (COD) concentration of the influent ranged from 20 to 37 kg COD m(-3). The reactor organic loading rate (OLR) fluctuated between 9 and 14.7 kg COD m(-3) d(-1) for hydraulic retention times (HRT) maintained between 55 and 68 h. At the highest OLR, the MPAR showed an efficiency of 98% and 92% for soluble and total COD removal, respectively, and a methane production rate averaging around 4 m(3) m(-3) d(-1).Biomass-specific activities ranged between 7 and 51, 1.3 and 8.5, 5.3 and 12.2, 60 and 119, and 119 and 211 mmol g(-1) VSS d(-1) for glucose, propionate, acetate, formate, and hydrogen, respectively. Average equivalent-diameter of the granules was around 0.65 mm. The MPAR reactor generally showed a large capacity for solid retention with a biomass content between 32 and 37 kg VSS m(-3). (c) 1995 John Wiley & Sons, Inc.  相似文献   

18.
Investigations were carried out by using rigid polyurethane foam as a packing material in the anaerobic contact filter (series) to treat distillery spentwash. The effect of hydraulic retention time (HRT) in treatment efficiency of reactor (I) and (II) was evaluated at different initial substrate concentrations ranging from 1500 mg/l to 19,000 mg/l. The effect of toxic parameters such as sulphate present in the distillery spentwash and the corresponding parameters such as total sulphide and un-ionized hydrogen sulphide generated during digestion of wastewater were evaluated to assess the reactor performance. The results showed that at 4 d HRT the overall COD removal percent ranged from 98% to 73% for an influent COD of 1500 mg/l to 19,000 mg/l. The overall performance of COD removal percent in reactor (I) and (II) at 2, 3 and 4 d HRT's were investigated. At 3 d HRT the reactor (II) showed a higher COD removal percent when compared to reactor (I), which clearly shows the role of hydraulic retention time in degradation of the organic matter present in the wastewater above an influent COD concentration of 5000 mg/l.  相似文献   

19.
A study of the anaerobic digestion of wastewater derived from the production of protein isolates from extracted sunflower flour was carried out in a laboratory-scale, mesophilic (35 degrees C) fluidized-bed reactor with saponite as bacterial support. Chemical oxygen demand (COD) removal efficiencies in the range of 98.3-80.0% were achieved in the reactor at organic loading rates (OLR) of between 0.6 and 9.3 g COD/I d, hydraulic retention times (HRT) of between 20.0 and 1.1 d and average feed COD concentration of 10.6 g/l. Eighty percent of feed COD could be removed up to OLR of 9.3 g COD/l d. The yield coefficient of methane production was 0.33 l of methane (at STP) per gram of COD removed and was virtually independent of the OLR applied. Because the buffering capacity of the experimental system was maintained at favorable levels with excess total alkalinity present at all loadings, the rate of methanogenesis was not affected by loading. The experimental data indicated that a total alkalinity in the range of 2,000-2,460 mg/l as CaCO3 was sufficient to prevent the pH from dropping to below 7.0 for OLR of up to 9.3 g COD/l d. The volatile fatty acid (VFA) levels and the VFA/alkalinity ratio were lower than the suggested limits for digester failure (0.3-0.4) for OLR and HRT up to 9.3 g COD/l d and 1.1 d, respectively. For a HRT of 0.87 d (OLR of 12.1 g COD/l d) the start of acidification was observed in the reactor.  相似文献   

20.
The aim of this study was to treat the wastewater collected from equalization tank of Common Effluent Treatment Plant (CETP), which was a mixture of waste coming from 525 small-scale industries manufacturing textile and dyestuff intermediate, pigments and pharmaceuticals. Initially a pretreatment using ferric chloride and lime was carried out to increase the biodegradability (BOD(5)/COD) of the effluent, which showed color removal of 74% and COD reduction of 75% at a concentration of 10 and 4 g/L. respectively. The biological treatment system using anaerobic fixed film reactor was investigated as secondary treatment. A mixture of bacterial consortium DMAB and cowdung slurry was used for the formation of biofilm. The effect of hydraulic retention time (HRT) and organic loading rate (OLR) on the efficiency of treatment of anaerobic reactor was analysed. Subsequent aerobic treatment after anaerobic step using aerobic culture Pseudomonas aeroginosa helped in further removal of COD and color. Formation of aromatic amines during anaerobic treatment was mineralized by sequential aerobic treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号