首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection—an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)—with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad).

Methods

We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included.

Results

The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%).

Conclusion

Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP—the first rapid diagnostic test for DENV infection—was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.  相似文献   

2.
Dengue has become endemic in Pakistan with annual recurrence. A sudden increase in the dengue cases was reported from Rawalpindi in 2016, while an outbreak occurred for the first time in Peshawar in 2017. Therefore, a multi-center study was carried out to determine the circulating dengue virus (DENV) serotypes and Chikungunya virus (CHIKV) co-infection in Lahore, Rawalpindi, and Peshawar cities in 2016–18. A hospital-based cross-sectional study was carried out in Lahore and Rawalpindi in 2016–18, while a community-based study was carried out in Peshawar in 2017. The study participants were tested for dengue NS1 antigen using an immunochromatographic device while anti-dengue IgM/IgG antibodies were detected by indirect ELISA. All NS1 positive samples were used for DENV serotyping using multiplex real-time PCR assay. Additionally, dengue samples were tested for CHIKV co-infection using IgM/IgG ELISA. A total of 6291 samples were collected among which 8.11% were NS1 positive while 2.5% were PCR positive. DENV-2 was the most common serotype (75.5%) detected, followed by DENV-1 in 16.1%, DENV-3 in 3.9% and DENV-4 in 0.7% while DENV-1 and DENV-4 concurrent infections were detected in 3.9% samples. DENV-1 was the predominant serotype (62.5%) detected from Lahore and Rawalpindi, while DENV-2 was the only serotype detected from Peshawar. Comorbidities resulted in a significant increase (p-value<0.001) in the duration of hospital stay of the patients. Type 2 diabetes mellitus substantially (p-value = 0.004) contributed to the severity of the disease. Among a total of 590 dengue positive samples, 11.8% were also positive for CHIKV co-infection. Co-circulation of multiple DENV serotypes and CHIKV infection in Pakistan is a worrisome situation demanding the urgent attention of the public health experts to strengthen vector surveillance.  相似文献   

3.
Diagnostic tests based on detection of dengue virus (DENV) genome are available with varying sensitivities and specificities. The Simplexa Dengue assay (Focus Diagnostics) is a newly developed real-time RT-PCR method designed to detect and serotype DENV simultaneously. To assess the performance of the Simplexa Dengue assay, we performed comparison with conventional RT-PCR and SYBR Green real-time RT-PCR on patients sera isolated from eight cities across Indonesia, a dengue endemic country. A total of 184 sera that were confirmed using NS1 and/or IgM and IgG ELISA were examined. Using conventional and SYBR Green real-time RT-PCR, we detected DENV in 53 (28.8%) and 81 (44.0%) out of 184 sera, respectively. When the Simplexa Dengue assay was employed, the detection rate was increased to 76.6% (141 out of 184 samples). When tested in 40 sera that were confirmed by virus isolation as the gold standard, the conventional RT-PCR yielded 95% sensitivity while the sensitivity of SYBR Green real-time RT-PCR and Simplexa Dengue assay reached 97.5% and 100%, respectively. The specificities of all methods were 100% when tested in 43 non-dengue illness and 20 healthy human samples. Altogether, our data showed the higher detection rate of Simplexa Dengue compared to conventional and SYBR Green real-time RT-PCR in field/surveillance setting. In conclusion, Simplexa Dengue offers rapid and accurate detection and typing of dengue infection and is suitable for both routine diagnostic and surveillance.  相似文献   

4.
Dengue and chikungunya are acute viral infections with overlapping clinical symptoms. Both diseases are transmitted by common mosquito vectors resulting in their co‐circulation in a region. Molecular and serological tests specific for both dengue and chikungunya infections were performed on 87 acute phase blood samples collected from patients with suspected dengue/chikungunya infections in Delhi from September to December, 2011. RT‐PCR and IgM ELISA were performed to detect dengue virus (DENV) and chikungunya virus (CHIKV). NS1 and IgG ELISA were also performed to detect DENV specific antigen and secondary DENV infection. DENV infection was detected in 49%, CHIKV infection in 29% and co‐infection with DENV and CHIKV in 10% of the samples by RT‐PCR. DENV serotypes 1, 2 and 3 were detected in this study. Nine DENV‐1 strains, six DENV‐2 strains and 20 CHIKV strains were characterized by DNA sequencing and phylogenetic analysis of their respective envelope protein genes. DENV‐1 strains grouped in the American African genotype, DENV‐2 strains in the Cosmopolitan genotype and CHIKV strains in the East Central South African genotype by phylogenetic analysis. This is one of the few studies reporting the phylogeny of two dengue virus serotypes (DENV‐1 and DENV‐2) and CHIKV. Surveillance and monitoring of DENV and CHIKV strains are important for design of strategies to control impending epidemics.  相似文献   

5.

Abstract/Background

Dengue is the most important arthropod borne viral disease worldwide in terms of morbidity and mortality and is caused by any of the four serotypes of dengue virus (DENV-1 to 4). Brazil is responsible for approximately 80% of dengue cases in the Americas, and since the introduction of dengue in 1986, a total of 5,944,270 cases have been reported including 21,596 dengue hemorrhagic fever and 874 fatal cases. DENV can infect many cell types and cause diverse clinical and pathological effects. The goal of the study was to investigate the usefulness of NS1 capture tests as an alternative tool to detect DENV in tissue specimens from previously confirmed dengue fatal cases (n = 23) that occurred in 2002 in Brazil.

Methodology/Principal Findings

A total of 74 tissue specimens were available: liver (n = 23), lung (n = 14), kidney (n = 04), brain (n = 10), heart (n = 02), skin (n = 01), spleen (n = 15), thymus (n = 03) and lymph nodes (n = 02). We evaluated three tests for NS1 antigen capture: first generation Dengue Early ELISA (PanBio Diagnostics), Platelia NS1 (BioRad Laboratories) and the rapid test NS1 Ag Strip (BioRad Laboratories). The overall dengue fatal case diagnosis based on the tissues analyzed by Dengue Early ELISA, Platelia NS1 and the NS1 Ag Strip was 34.7% (08/23), 60.8% (14/23) and 91.3% (21/23), respectively. The Dengue Early ELISA detected NS1 in 22.9% (17/74) of the specimens analyzed and the Platelia NS1 in 45.9% (34/74). The highest sensitivity (78.3%; 58/74) was achieved by the NS1 Ag Strip, and the differences in the sensitivities were statistically significant (p<0.05). The NS1 Ag Strip was the most sensitive in liver (91.3%; 21/23), lung (71.4%; 10/14), kidney (100%; 4/4), brain (80%; 8/10), spleen (66.6%, 10/15) and thymus (100%, 3/3) when compared to the other two ELISA assays.

Conclusions/Significance

This study shows the DENV NS1 capture assay as a rapid and valuable approach to postmortem dengue confirmation. With an increasing number of DHF and fatal cases, the availability of new approaches useful for cases confirmation plays an important tool for the disease surveillance.  相似文献   

6.

Background

Dengue is a public health problem in many countries. Rapid diagnosis of dengue can assist patient triage and management. Detection of the dengue viral protein, NS1, represents a new approach to dengue diagnosis.

Methodology/Principal Findings

The sensitivity and specificity of the Platelia NS1 ELISA assay and an NS1 lateral flow rapid test (LFRT) were compared against a gold standard reference diagnostic algorithm in 138 Vietnamese children and adults. Overall, the Platelia NS1 ELISA was modestly more sensitive (82%) than the NS1 LFRT (72%) in confirmed dengue cases. Both ELISA and LFRT assays were more sensitive for primary than secondary dengue, and for specimens collected within 3 days of illness onset relative to later time points. The presence of measurable DENV-reactive IgG and to a lesser extent IgM in the test sample was associated with a significantly lower rate of NS1 detection in both assays. NS1 positivity was associated with the underlying viraemia, as NS1-positive samples had a significantly higher viraemia than NS1-negative samples matched for duration of illness. The Platelia and NS1 LFRT were 100% specific, being negative in all febrile patients without evidence of recent dengue, as well as in patients with enteric fever, malaria, Japanese encephalitis and leptospirosis.

Conclusions/Significance

Collectively, these data suggest NS1 assays deserve inclusion in the diagnostic evaluation of dengue patients, but with due consideration for the limitations in patients who present late in their illness or have a concomitant humoral immune response.  相似文献   

7.

Background

Early diagnosis of dengue can assist patient triage and management and prevent unnecessary treatments and interventions. Commercially available assays that detect the dengue virus protein NS1 in the plasma/serum of patients offers the possibility of early and rapid diagnosis.

Methodology/Principal Findings

The sensitivity and specificity of the Pan-E Dengue Early ELISA and the Platelia™ Dengue NS1 Ag assays were compared against a reference diagnosis in 1385 patients in 6 countries in Asia and the Americas. Platelia was more sensitive (66%) than Pan-E (52%) in confirmed dengue cases. Sensitivity varied by geographic region, with both assays generally being more sensitive in patients from SE Asia than the Americas. Both kits were more sensitive for specimens collected within the first few days of illness onset relative to later time points. Pan-E and Platelia were both 100% specific in febrile patients without evidence of acute dengue. In patients with other confirmed diagnoses and healthy blood donors, Platelia was more specific (100%) than Pan-E (90%). For Platelia, when either the NS1 test or the IgM test on the acute sample was positive, the sensitivity versus the reference result was 82% in samples collected in the first four days of fever. NS1 sensitivity was not associated to disease severity (DF or DHF) in the Platelia test, whereas a trend for higher sensitivity in DHF cases was seen in the Pan-E test (however combined with lower overall sensitivity).

Conclusions/Significance

Collectively, this multi-country study suggests that the best performing NS1 assay (Platelia) had moderate sensitivity (median 64%, range 34–76%) and high specificity (100%) for the diagnosis of dengue. The poor sensitivity of the evaluated assays in some geographical regions suggests further assessments are needed. The combination of NS1 and IgM detection in samples collected in the first few days of fever increased the overall dengue diagnostic sensitivity.  相似文献   

8.
Laboratory diagnosis of dengue virus (DENV) infection including DENV serotyping requires skilled labor and well-equipped settings. DENV NS1 lateral flow rapid test (LFT) provides simplicity but lacks ability to identify serotype. A simple, economical, point-of-care device for serotyping is still needed. We present a gravity driven, smartphone compatible, microfluidic device using microcapillary film (MCF) to perform multiplex serotype-specific immunoassay detection of dengue virus NS1. A novel device–termed Cygnus–with a stackable design allows analysis of 1 to 12 samples in parallel in 40 minutes. A sandwich enzyme immunoassay was developed to specifically detect NS1 of all four DENV serotypes in one 60-μl plasma sample. This test aims to bridge the gap between rapid LFT and laboratory microplate ELISAs in terms of sensitivity, usability, accessibility and speed. The Cygnus NS1 assay was evaluated with retrospective undiluted plasma samples from 205 DENV infected patients alongside 50 febrile illness negative controls. Against the gold standard RT-PCR, clinical sensitivity for Cygnus was 82% in overall (with 78, 78, 80 and 76% for DENV1-4, respectively), comparable to an in-house serotyping NS1 microplate ELISA (82% vs 83%) but superior to commercial NS1-LFT (82% vs 74%). Specificity of the Cygnus device was 86%, lower than that of NS1-microplate ELISA and NS1-LFT (100% and 98%, respectively). For Cygnus positive samples, identification of DENV serotypes DENV2-4 matched those by RT-PCR by 100%, but for DENV1 capillaries false positives were seen, suggesting an improved DENV1 capture antibody is needed to increase specificity. Overall performance of Cygnus showed substantial agreement to NS1-microplate ELISA (κ = 0.68, 95%CI 0.58–0.77) and NS1-LFT (κ = 0.71, 95%CI 0.63–0.80). Although further refinement for DENV-1 NS1 detection is needed, the advantages of multiplexing and rapid processing time, this Cygnus device could deliver point-of-care NS1 antigen testing including serotyping for timely DENV diagnosis for epidemic surveillance and outbreak prediction.  相似文献   

9.
BackgroundAccurate, rapid, and early diagnosis of dengue virus (DENV) infections is essential for optimal clinical care. Here, we evaluated the efficacy of the quantitative real-time PCR (qRT-PCR)-LightMix dengue virus EC kit for DENV detection using samples from a dengue outbreak in Taiwan in 2015.MethodsSera from patients with suspected DENV infection were analyzed and compared using the LightMix kit, a Dengue NS1 Ag + Ab Combo kit for detection of NS1 antigen and DENV-specific IgM and IgG antibodies, and an “in-house” qualitative DENV-specific RT-PCR assay.ResultsA total of 8,989, 8,954, and 1581 samples were subjected to NS1 antigen detection, IgM and IgG detection, and LightMix assays, respectively. The LightMix assay yielded a linear curve for viral loads (VL) between 102 and 106 copies/reaction, and the minimum detection limits for DENV serotype 1 (DENV1) and DENV2, DENV3, and DENV4 were 1, 10, and 100 focus forming units (FFU)/mL, respectively. There was 88.9% concordance between the results obtained using the NS1 antigen combo kit and by LightMix analysis, and the diagnostic sensitivity and specificity of the two methods were 89.4 and 100%, and 84.7 and 100%, respectively. Notably, fatal cases were attributed to DENV2 infection, and 79.5% (27/34) of these cases occurred in patients ≥ 71 years of age. Among these older patients, 82.3% (14/17) were NS1/IgM/IgG (+/-/-), exhibiting VLs between 106–109 copies/mL, which was markedly higher than the rate observed in the other age groups.ConclusionsThe LightMix assay was effective for early diagnosis of DENV infection. Our data indicate that high VLs during primary infection in elderly patients may be a positive predictor for severe illness, and may contribute to high mortality rates.  相似文献   

10.

Background

Early diagnosis of dengue virus (DENV) infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1) has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs) and enzyme-linked immunosorbent assays (ELISAs) targeting NS1 antigen (Ag) are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.

Methodology/Principal Findings

Retrospective samples from South America were used to evaluate the following tests: (i) “Dengue NS1 Ag STRIP” and (ii) “Platelia Dengue NS1 Ag ELISA” (Bio-Rad, France), (iii) “Dengue NS1 Detect Rapid Test (1st Generation)” and (iv) “DENV Detect NS1 ELISA” (InBios International, United States), (v) “Panbio Dengue Early Rapid (1st generation)” (vi) “Panbio Dengue Early ELISA (2nd generation)” and (vii) “SD Bioline Dengue NS1 Ag Rapid Test” (Alere, United States). Overall, the sensitivity of the RDTs ranged from 71.9%–79.1% while the sensitivity of the ELISAs varied between 85.6–95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3–4 post symptom onset. The specificity of all evaluated tests ranged from 95%–100%.

Conclusions

ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.  相似文献   

11.
12.
Dengue is one of the most significant public health problems in tropical and subtropical countries, and is increasingly being detected in traditionally non-endemic areas. In Bhutan, dengue virus (DENV) has only recently been detected and limited information is available. In this study, we analyzed the epidemiological and molecular characteristics of DENV in two southern districts in Bhutan from 2013–2014. During this period, 379 patients were clinically diagnosed with suspected dengue, of whom 119 (31.4%) were positive for DENV infection by NS1 ELISA and/or nested RT-PCR. DENV serotypes 1, 2 and 3 were detected with DENV-1 being predominant. Phylogenetic analysis of DENV-1 using envelope gene demonstrated genotype V, closely related to strains from northern India.  相似文献   

13.

Background

Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens.

Methodology/Principal Findings

The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7.

Conclusion/Significance

The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.  相似文献   

14.

Background

Dengue virus (DENV) NS1 antigen detection is regarded as an early diagnostic marker. Accordingly, several studies have evaluated the performance of tests that utilize NS1 capture, but the results of individual studies may be limited due to the restricted sample size of the patients recruited. Therefore, our objective was to perform a meta-analysis of the diagnostic accuracy of two commercial NS1 ELISAs (Panbio and Platelia).

Methods and Results

Studies of interest were found in PubMed, Embase and Google Scholar databases using defined inclusion/exclusion criteria. A total of 30 studies containing 12,105 total enrolled patients were included. The results were as follows: 1) Panbio assays showed low overall performance, sensitivity 66% (95% confidence interval (CI) 61–71), specificity 99% (95% CI 96–100), positive likelihood ratio (LR+) 98 (95% CI 20–464), negative likelihood ratio (LR-) 0.3 (95% CI 0.2–0.4), diagnostic odds ratio (DOR) 289 (95% CI 59–1412); 2) Platelia assays showed high overall performance, sensitivity 74% (95% CI 63–82), specificity 99% (95% CI 97–100), LR+ 175 (95% CI 28–1099), LR- 0.3 (95% CI 0.2–0.4), DOR 663 (95% CI 98–4478). The lowest sensitivity values were for secondary infections (57% [95% CI 47–67] and 66% [95% CI 53–77] for Panbio and Platelia, respectively) and for the detection of DENV4. Regarding clinical manifestations, the sensitivity of Platelia was 69% (95% CI 43–86) and 60% (95% CI 48–70) for fever and dengue hemorrhagic fever, respectively. In addition, the sensitivity of both tests was slightly lower for samples from Southeast Asia and Oceania.

Conclusion

DENV1 samples gave higher sensitivity results for both tests. We observed that factors negatively influencing the tests, such as the type of infection, geographical origins of samples and viral serotypes, require further investigation to optimize the diagnostic accuracy.  相似文献   

15.
制备抗登革病毒NS1蛋白单克隆抗体,建立检测NS1的ELISA方法。表达1~4型登革病毒NS1蛋白,将1型NS1蛋白纯化后免疫BALB/c小鼠,通过杂交瘤技术制备单克隆抗体。经ELISA、Western blotting、间接免疫荧光筛选和鉴定单克隆抗体,进行纯化和HRP标记。通过鉴定每两株单抗之间是否存在竞争作用,选择非竞争单抗组合并建立NS1捕获法ELISA。结果获得7株高滴度抗NS1单抗,捕获法ELISA可以检出10ng/mL NS1。原核表达登革病毒NS1蛋白制备的单抗可以和天然病毒抗原反应,NS1捕获法ELISA可以用于登革病毒感染检测。  相似文献   

16.

Background

Detection of dengue NS1 antigen in acute infection has been proposed for early diagnosis of dengue disease. The aim of this study was to evaluate the clinical and virological factors influencing the performance of the Platelia NS1 Ag kit (BioRad) and to assess the potential use of NS1 antigen and dengue viral loads as markers of dengue disease severity.

Methodology/Principal Findings

Blood specimens were collected from patients hospitalized at the Kampong Cham hospital during the 2006 and 2007 dengue epidemics in Cambodia. Dengue infection was confirmed in 243/339 symptomatic patients and in 17 asymptomatic individuals out of 214 household members tested. Overall sensitivity and specificity of Platelia NS1 Ag kit were 57.5% and 100% respectively. NS1 Ag assay combined with IgM antibody capture ELISA significantly increased the sensitivity for dengue diagnosis. NS1 Ag positivity rate was found significantly higher in DF than in DHF/DSS, in primary than in secondary infections, in patients with a high viremia (>5 log/mL) and in patients infected with DENV-1. In asymptomatic individuals, the NS1 Ag capture sensitivity tends to be lower than that in symptomatic patients. Milder disease severity was observed independently in patients with RNA copy number >5 log10 cDNA equivalents/mL or in high level of NS1 antigen ratio or in DENV-1 infection.

Conclusions

Overall sensitivity of NS1 Ag detection kit varied widely across the various forms of dengue infection or disease. Sensitivity was highest in patients sampled during the first 3 days after onset of fever, in patients with primary infection, DENV-1 infection, with high level of viremia and in DF rather than DHF/DSS. In asymptomatic patients, RT-PCR assay has proved to be more sensitive than NS1 antigen detection. The NS1 antigen level correlated significantly with viremia and a low NS1 antigen ratio was associated with more severe disease.  相似文献   

17.
Dengue virus (DENV) is the principal arthropod-borne viral pathogen afflicting human populations. While repertoires of antibodies to DENV have been linked to protection or enhanced infection, the role of T lymphocytes in these processes remains poorly defined. This study provides a comprehensive overview of CD4+ and CD8+ T cell epitope reactivities against the DENV 2 proteome in adult patients experiencing secondary DENV infection. Dengue virus-specific T cell responses directed against an overlapping 15mer peptide library spanning the DENV 2 proteome were analyzed ex vivo by enzyme-linked immunosorbent spot assay, and recognition of individual peptides was further characterized in specific T cell lines. Thirty novel T cell epitopes were identified, 9 of which are CD4+ and 21 are CD8+ T cell epitopes. We observe that whereas CD8+ T cell epitopes preferentially target nonstructural proteins (NS3 and NS5), CD4+ epitopes are skewed toward recognition of viral components that are also targeted by B lymphocytes (envelope, capsid, and NS1). Consistently, a large proportion of dengue virus-specific CD4+ T cells have phenotypic characteristics of circulating follicular helper T cells (CXCR5 expression and production of interleukin-21 or gamma interferon), suggesting that they are interacting with B cells in vivo. This study shows that during a dengue virus infection, the protein targets of human CD4+ and CD8+ T cells are largely distinct, thus highlighting key differences in the immunodominance of DENV proteins for these two cell types. This has important implications for our understanding of how the two arms of the human adaptive immune system are differentially targeted and employed as part of our response to DENV infection.  相似文献   

18.
19.
BackgroundDengue virus (DENV) infection is prevalent across tropical regions and may cause severe disease. Early diagnosis may improve supportive care. We prospectively assessed the Standard Diagnostics (Korea) BIOLINE Dengue Duo DENV rapid diagnostic test (RDT) to NS1 antigen and anti-DENV IgM (NS1 and IgM) in children in Cambodia, with the aim of improving the diagnosis of DENV infection.ConclusionsThe DENV RDT had low sensitivity for the diagnosis of DENV infection. The high co-prevalence of infections in our cohort indicates the need for a broad microbiological assessment of non-localised febrile illness in these children.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号