首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A comprehensive on-line sample clean-up with an integrated two-dimensional HPLC system was developed for the analysis of natural peptides. Samples comprised of endogenous peptides with molecular weights up to 20 kDa were generated from human hemofiltrate (HF) obtained from patients with chronic renal failure. The (poly-)peptides were separated using novel silica-based restricted access materials with strong cation-exchange functionalities (SCX-RAM). The size-selective sample fractionation step is followed by cation-exchange chromatography as the first dimension. The subsequent second dimension of separation is based on hydrophobic interaction using four parallel short reversed-phase (RP) columns implemented via a fully automated column switching technique. More than 1000 peaks were resolved within the total analysis time of 96 min. Substances of selected peaks were sampled to analyse their molecular weights by off-line MALDI-TOF mass spectrometry and to determine their amino acid sequence by Edman degradation. The potential for comprehensive peptide mapping and identification is demonstrated.  相似文献   

2.
Lu CY  Wu CY  Lin CH 《Analytical biochemistry》2007,368(2):123-129
In typical mass spectrometry-based protein identification using peptide fragmentation fingerprinting, front-end separation plays a critical role in successful peptide sequencing. This separation step demands a great deal of time and usually is the rate-limiting step for the whole process. Here we provide an alternative separation method, based on a simple nanoflow delivery system, that is able to shorten the separation time considerably. This system consists of a 25-mul syringe connected to a manually packed reversed-phase mini-capillary column that can be directly coupled to an electrospray ionization tandem mass spectrometer. A syringe pump is then used to deliver the peptide mixtures at a nanoscale flow rate. We examined the efficiency and efficacy of this method by analyzing the tryptic peptides of bovine serum albumin and of 10 Escherichia coli proteins separated by two-dimensional gel electrophoresis (2DE). The results showed that identification of each protein could be achieved successfully within 25 min by using the disposable mini-capillary column. Moreover, all 2DE-separated E. coli proteins were identified at high confidence levels. Together, our data suggest that this method is a suitable option for mass spectrometry-based protein identification.  相似文献   

3.
We report upon a novel procedure to specifically isolate cysteine-containing peptides from a complex peptide mixture. Cysteines are converted to hydrophobic residues by mixed disulfide formation with Ellman's reagent. Proteins are subsequently digested with trypsin and the generated peptide mixture is a first time fractionated by reverse-phase high-performance liquid chromatography. Cysteinyl-peptides are isolated out of each primary fraction by a reduction step followed by a secondary peptide separation on the same column, performed under identical conditions as for the primary separation. The reducing agent removes the covalently attached group from the cysteine side chain, making cysteine-peptides more hydrophilic and, thereby, such peptides can be specifically collected during the secondary separation and are finally used to identify their precursor proteins using automated liquid chromatography tandem mass spectrometry. We show that this procedure efficiently isolates cysteine-peptides, making the sample mixture less complex for further analysis. This method was applied for the analysis of the proteomes of human platelets and enriched human plasma. In both proteomes, a significant number of low abundance proteins were identified next to extremely abundant ones. A dynamic range for protein identification spanning 4-5 orders of magnitude is demonstrated.  相似文献   

4.
Jiang X  Feng S  Tian R  Han G  Jiang X  Ye M  Zou H 《Proteomics》2007,7(4):528-539
An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.  相似文献   

5.
A two-dimensional (2D) separation method was used to decrease sample complexity in analysis of tryptic peptides from glomerular membrane proteins by tandem mass spectrometry (MS/MS). The first dimension was carried out by electrocapture (EC), which fractionates peptides according to electrophoretic mobility. The second dimension was reverse-phase liquid chromatography (RP-LC), in which EC fractions were further separated and analyzed online by MS/MS. Using this methodology, we now identify 102 glomerular proteins (57 membrane proteins). Many peptides were possible to observe and select for MS/MS only using the 2D approach. Others were detectable in both one-dimensional (1D, without the EC step) and 2D experiments but were selectable for sequence analysis only from the 2D separations because the decrease in complexity then gives time for the mass analyzer to select the peptide and switch to the MS/MS mode. A minority of the peptides were detectable only in the 1D mode (presumably because of handling losses), but at the end this did not decrease the number of proteins identified by the 2D separation. After a database search, the combination of EC and RP-LC MS/MS versus a 1D RP-LC MS/MS separation resulted in a threefold increase in the number of proteins identified and improved the sequence coverage in the identifications, bringing our proteome-identified glomerular proteins to 282.  相似文献   

6.
采用自动在线纳流多维液相色谱 串联质谱联用的方法分离和鉴定蔗糖密度梯度离心法分离和富集的小鼠肝脏质膜蛋白质 .以强阳离子交换柱为第一相 ,反相柱为第二相 ,在两相之间连接一预柱脱盐和浓缩肽段 .用含去污剂的溶剂提取细胞质膜中的蛋白质 ,获得的质膜蛋白质经酶解和适当的酸化后通过离子交换柱吸附 ,分别用 10个不同浓度的乙酸铵盐溶液进行分段洗脱 .洗脱物经预柱脱盐和浓缩后进入毛细管反相柱进行反相分离 ,分离后的肽段直接进入质谱仪离子源进行一级和二级质谱分析 .质谱仪采得的数据经计算机处理后用Mascot软件进行蛋白质数据库搜寻 ,共鉴定出 12 6种蛋白质 ,其中 4 1种为膜蛋白 ,包括与膜相关的蛋白质和具有多个跨膜区的整合膜蛋白 ,为建立质膜蛋白质组学研究的适宜方法和质膜蛋白质数据库提供了有价值的基础性研究资料 .  相似文献   

7.
Recently, we have developed a high-resolution two-dimensional separation strategy for the analysis of complex peptide mixtures. This methodology employs isoelectric focusing of peptides on immobilized pH gradient (IPG) gels in the first dimension, followed by reversed-phase chromatography in the second dimension, and subsequent tandem mass spectrometry analysis. The traditional approach to this mixture problem employs strong-cation-exchange (SCX) chromatography in the first dimension. Here, we present a direct comparison of these two first-dimensional techniques using complex protein samples derived from the testis of Rattus norvegicus. It was found that the use of immobilized pH gradients (narrow range pH 3.5-4.5) for peptide separation in the first dimension yielded 13% more protein identifications than the optimized off-line SCX approach (employing the entire pI range of the sample). In addition, the IPG technique allows for a much more efficient use on mass spectrometer analysis time. Separation of a tryptic digest derived from a rat testis sample on a narrow range pH gradient (over the 3.5-4.5 pH range) yielded 7626 and 2750 peptides and proteins, respectively. Peptide and protein identification was performed with high confidence using SEQUEST in combination with a data filtering program employing pI and statistical based functions to remove false-positives from the data.  相似文献   

8.
A new hydrophilic interaction chromatography (HILIC) column packed with amide 1.7 μm sorbent was applied to the characterization of glycoprotein digests. Due to the impact of the hydrophilic carbohydrate moiety, glycopeptides were more strongly retained on the column and separated from the remaining nonglycosylated peptides present in the digest. The glycoforms of the same parent peptide were also chromatographically resolved and analyzed using ultraviolet and mass spectrometry detectors. The HILIC method was applied to glyco-profiling of a therapeutic monoclonal antibody and proteins with several N-linked and O-linked glycosylation sites. For characterization of complex proteins with multiple glycosylation sites we utilized 2D LC, where RP separation dimension was used for isolation of glycopeptides and HILIC for resolution of peptide glycoforms. The analysis of site-specific glycan microheterogeneity was illustrated for the CD44 fusion protein.  相似文献   

9.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

10.
An improved capillary liquid chromatography procedure, incorporating column switching in combination with mass spectrometry, is reported. The dual column system allows for rapid inject-to-inject cycle times to improve the speed of protein identification for proteomics applications. Full gradient elution of peptides from either of the two C18 columns can be achieved in less than 17 min while maintaining sufficient resolution for the peptides to be detected and fragmented by the mass spectrometer for protein identification. Importantly, the use of two columns for subsequent injections is reproducible and without carry-over. The limit of detection for the system is between 25 and 50 fmol per injection. This fully automated system is capable of analyzing and identifying proteins from an entire 96-well plate in about 27 h.  相似文献   

11.
An alternative strategy for mitochondrial proteomics is described that is complementary to previous investigations using 2D PAGE techniques. The strategy involves (a) obtaining highly purified preparations of human heart mitochondria using metrizamide gradients to remove cytosolic and other subcellular contaminant proteins; (b) separation of mitochondrial protein complexes using sucrose density gradients after solubilization with n-dodecyl-beta-D-maltoside; (c) 1D electrophoresis of the sucrose gradient fractions; (d) high-throughput proteomics using robotic gel band excision, in-gel digestion, MALDI target spotting and automated spectral acquisition; and (e) protein identification from mixtures of tryptic peptides by high-precision peptide mass fingerprinting. Using this approach, we rapidly identified 82 bona fide or potential mitochondrial proteins, 40 of which have not been previously reported using 2D PAGE techniques. These proteins include small complex I and complex IV subunits, as well as very basic and hydrophobic transmembrane proteins such as the adenine nucleotide translocase that are not recovered in 2D gels. The technique described here should also be useful for the identification of new protein-protein associations as exemplified by the validation of a recently discovered complex that involves proteins belonging to the prohibitin family.  相似文献   

12.
Defining membrane proteomes is fundamental to understand the role of membrane proteins in biological processes and to find new targets for drug development. Usually multidimensional chromatography using step or gradient elution is applied for the separation of tryptic peptides of membrane proteins prior to their mass spectrometric analysis. Displacement chromatography (DC) offers several advantages that are helpful for proteome analysis. However, DC has so far been applied for proteomic investigations only in few cases. In this study we therefore applied DC in a multidimensional LC–MS approach for the separation and identification of membrane proteins located in cholesterol-enriched membrane microdomains (lipid rafts) obtained from rat kidney by density gradient centrifugation. The tryptic peptides were separated on a cation-exchange column in the displacement mode with spermine used as displacer. Fractions obtained from DC were analyzed using an HPLC-chip system coupled to an electrospray-ionization ion-trap mass spectrometer. This procedure yielded more than 400 highly significant peptide spectrum matches and led to the identification of more than 140 reliable protein hits within an established rat kidney lipid raft proteome. The majority of identified proteins were membrane proteins. In sum, our results demonstrate that DC is a suitable alternative to gradient elution separations for the identification of proteins via a multidimensional LC–MS approach.  相似文献   

13.
Detection of biologically interesting, low-abundance proteins in complex proteomes such as serum typically requires extensive fractionation and high-performance mass spectrometers. Processing of the resulting large data sets involves trade-offs between confidence of identification and depth of protein coverage; that is, higher stringency filters preferentially reduce the number of low-abundance proteins identified. In the current study, an alternative database search and results filtering strategies were evaluated using test samples ranging from purified proteins to ovarian tumor secretomes and human serum to maximize peptide and protein coverage. Full and partial tryptic searches were compared because substantial numbers of partial tryptic peptides were observed in all samples, and the proportion of partial tryptic peptides was particularly high for serum. When data filters that yielded similar false discovery rates (FDR) were used, full tryptic searches detected far fewer peptides than partial tryptic searches. In contrast to the common practice of using full tryptic specificity and a narrow precursor mass tolerance, more proteins and peptides could be confidently identified using a partial tryptic database search with a 100 ppm precursor mass tolerance followed by filtering of results using 10 ppm mass error and full tryptic boundaries.  相似文献   

14.
This study describes the application of a single tube sample preparation technique coupled with multidimensional fractionation for the analysis of a complex membrane protein sample from murine natural killer (NK) cells. A solution-based method that facilitates the solubilization and tryptic digestion of integral membrane proteins is conjoined with strong cation exchange (SCX) liquid chromatography (LC) fractionation followed by microcapillary reversed-phase (microRP) LC tandem mass spectrometric analysis of each SCXLC fraction in second dimension. Sonication in buffered methanol solution was employed to solubilize, and tryptically digest murine NK cell microsomal proteins, allowing for the large-scale identification of integral membrane proteins, including the mapping of the membrane-spanning peptides. Bioinformatic analysis of the acquired tandem mass spectra versus the murine genome database resulted in 11,967 matching tryptic peptide sequences, corresponding to 5782 unique peptide identifications. These peptides resulted in identification of 2563 proteins of which 876 (34%) are classified as membrane proteins.  相似文献   

15.

Introduction

With the rapid development of mass spectrometry-based technologies such as multiple reaction monitoring and heavy-isotope-labeled-peptide standards, quantitative analysis of biomarker proteins using mass spectrometry is rapidly progressing toward detection of target proteins/peptides from clinical samples. Proteotypic peptides are a few peptides that are repeatedly and consistently identified from a protein in a mixture and are used for quantitative analysis of the protein in a complex biological sample by mass spectrometry.

Materials and Methods

Using mass spectrometry, we identified peptide sequences and provided a list of tryptic peptides and glycopeptides as proteotypic peptides from five clinically used tumor markers, including prostate-specific antigen, carcinoembryonic antigen, Her-2, human chorionic gonadotropin, and CA125.

Conclusion

These proteotypic peptides have potential for targeted detection as well as heavy-isotope-peptide standards for quantitative analysis of marker proteins in clinical specimens using a highly specific, sensitive, and high-throughout mass spectrometry-based analysis method.  相似文献   

16.
A method for the selective enrichment of tryptophan-containing peptides from complex peptide mixtures such as protein digests is presented. It is based on the reversible reaction of tryptophan with malondialdehyde and trapping of the derivatized Trp-peptides on hydrazide beads via the free aldehyde group of the modified peptides. The peptides are subsequently recovered in their native form by specific cleavage reactions for further (mass spectrometric) analysis. The method was optimized and evaluated using a tryptic digest of a mixture of 10 model proteins, demonstrating a significant reduction in sample complexity while still allowing the identification of all proteins. The applicability of the tryptophan-specific enrichment procedure to complex biological samples is demonstrated for a total yeast cell lysate. Analysis of the processed fraction by 1D-LC-MS/MS confirms the specificity of the enrichment procedure, as more than 85% of the peptides recovered from the enrichment step contained tryptophan. The reduction in sample complexity also resulted in the identification of additional proteins in comparison to the untreated lysate.  相似文献   

17.
18.
Garaguso I  Borlak J 《Proteomics》2008,8(13):2583-2595
The analytical performance of MALDI-MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI-MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5-dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI-MS and MS/MS with high quality spectra acquisition. The between-spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower-attomole range for peptides, and we improved the performance of MALDI-MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in-gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in-gel digests from lung tissue lysate proteins separated by 2-DE.  相似文献   

19.
A high-throughput approach for biomolecule analysis is demonstrated for a mixture of peptides from tryptic digest of four proteins as well as a tryptic digests of human plasma. In this method a chip based electrospray autosampler coupled to a hybrid ion mobility (IMS) mass spectrometer (MS) is utilized to achieve rapid sample analysis. This high-throughput measurement is realized by exploiting the direct infusion capability of the chip based electrospray with its rapid sample manipulating capability as well as a high sensitive IMS-MS with a recently developed IMS-IMS separation technique that can be multiplexed to provide greater throughput. From replicate IMS-MS runs of known mixtures, the average uncertainty of peak intensities is determined to be +/-7% (relative standard deviation), and a detection limit in the low attomole range is established. The method is illustrated by analyzing 124 human plasma protein samples in duplicate, a measurement that required 16.5 h. Current limitations as well as implications of the high-throughput approach for complex biological sample analysis are discussed.  相似文献   

20.
A reliable high-performance liquid chromatography (HPLC) method is described for the separation of dimethylamino-azobenzenesulfonyl-amino acid (DABS-AA). The separation is accomplished by reversed-phase chromatography on a Hypersil ODS column (4.6×150 mm) withe a Hewlett-Packard liquid chromatography system. In addition to the developed sample and solvent preparation procedure, this precolumn modification method using dimethylaminoazobenzene sulfonyl chloride (DABS-CL) for amino acid analysis is proved reliable and sensitive. Five apolipoprotein B-100 tryptic peptides, two of them containing cysteine, were demonstrated as examples for the general application of this method in amino acid analysis. It is a useful method for analysis of cysteine- and cysteine-containing peptide and, furthermore, for determination of sulfhydryl and disulfide linkages of proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号