首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 708 毫秒
1.
Monoparametric immunoassay tests for detecting botulinum toxins types A and B and multiparametric assays for simultaneous detection of botulinum toxins type A and B have been developed. It is shown that the sensitivity of assays is affected by the size of nanoparticles of colloidal gold used as a marker of antibodies, load intensity of antibodies of colloidal gold in conjugates, the type of analytical membranes, as well as the chemical composition of buffer solutions used for the storage of conjugates and immunoassay analysis. The detection limit of monoparametric immunoassay tests is 0.5 ng/ml; that of multiparametric assays, 5.0 ng/ml. The developed immunoassay can be used for rapid assay of product quality, for grade control of botulinum toxins in pharmaceuticals, and environmental monitoring.  相似文献   

2.
Mouse monoclonal antibodies against the most acutely toxic substances, botulinum neurotoxins (BoNTs) of types A, B, E, and F, was generated and characterized, that recognize their respective toxins in natural toxin complex. Based on these antibodies, we developed sandwich-ELISA for quantitative detection of these toxins. For each respective toxin the detection limit of the assay was: BoNT/A - 0.4 ng/ml, BoNT/B - 0.5 ng/ml; BoNT/E - 0.1 ng/ml; and for BoNT/F - 2.4 ng/ml. The developed assays permitted quantitative identification of the BoNTs in canned meat and vegetables. The BNTA-4.1 and BNTA-9.1 antibodies possessed neutralizing activity against natural complex of the botulinium toxin type A in vivo, both individually and in mixture, the mixture of the antibodies neutralized the higher dose of the toxin. The BNTA-4.1 antibody binds specifically the light chain (the chain with protease activity) of the toxin, whereas BNTA-9.1 interacts with the heavy chain. We believe that the BNTA-4.1 and BNTA-9.1 monoclonal antibodies are prospective candidates for development of humanized therapeutic antibodies for treatment of BoNT/A-caused botulism.  相似文献   

3.
Assay sensitivities using three fluorescent signal generation schemes were evaluated on the Luminex flow cytometer. Following microsphere capture of antigen by immobilized antibodies, bound targets were quantified by use of (1) Cy3-labeled "tracer" antibodies (30min total time), (2) biotinylated tracers followed by streptavidin-R-phycoerythrin (60min total time), or (3) biotinylated tracers followed by avidin-peroxidase conjugates and tyramide signal amplification (TSA; 90min total time). Use of TSA for signal generation in three individual toxin assays improved performance up to 100-fold over Cy3-antibody-based detection, and while streptavidin-R-phycoerythrin provided equivalent sensitivities, TSA produced dramatic increases at low concentrations simplifying positive sample identification. Detection limits for TSA-interrogated assays for ricin, cholera toxin, and staphylococcal enterotoxin B were 64pg/ml, 4pg/ml, and 0.1ng/ml, respectively, using optimized conjugates; analogous detection limits for Cy3-antibody-interrogated assays were 8ng/ml, 1ng/ml, and 1ng/ml, respectively. No improvement was observed in botulinum toxoid A assays when TSA amplification was used. As unique preferences for specific avidin-peroxidase conjugates were observed in the individual assays, improvements in multiplexed assays utilizing a single conjugate were significantly lower (3-10-fold improvements). Furthermore, increases in variability resulted in poorer performance of TSA-interrogated assays for botulinum toxoid, indicating that assay-specific optimization should be performed, especially prior to multiplexing.  相似文献   

4.
Sensitive and specific electrochemiluminescence (ECL) assays were used to detect Clostridium botulinum neurotoxins serotypes A, B, E, and F in undiluted human serum, undiluted human urine, assay buffer, and selected food matrices (whole milk, apple juice, ground beef, pastry, and raw eggs). These novel assays used paramagnetic bead-based electrochemiluminescent technology in which biotinylated serotype-specific antibodies were bound to streptavidin-coated paramagnetic beads. The beads acted as the solid support and captured analyte from solution. Electrochemiluminescent detection relied on the use of ruthenium chelate-labeled anti-serotype antibodies and analysis with a BioVeris M-Series M1R analyzer. The sensitivities of the assays in clinically relevant matrices were 50 pg/ml for serotypes A and E, 100 pg/ml for serotype B, and 400 pg/ml for serotype F. The detection limits in selected food matrices ranged from 50 pg/ml for serotype A to 50 to 100 pg/ml for serotypes B, E, and F. The antibodies used for capture and detection exhibited no cross-reactivity when tested with the other serotypes. When purified native toxin was compared with toxins complexed to neurotoxin-associated proteins, no significant differences in assay response were noted for serotypes A, B, and F. Interestingly, the native form of serotype E exhibited reduced signal and limit of detection compared with the complexed form of the protein. We suspect that this difference may be due to trypsin activation of this particular serotype. The assays described in this article demonstrate limits of detection similar in range to the gold standard mouse bioassay, but with greatly reduced time to data. These rapid sensitive assays may have potential use in clinical settings, research studies, and screening of food products for botulinum toxins.  相似文献   

5.
Quantitative immunoassay of biotoxins on hydrogel-based protein microchips   总被引:3,自引:0,他引:3  
Three-dimensional gel-based microchips with immobilized proteins were used for quantitative immunoassay of a series of plant (ricin and viscumin) and bacterial (staphylococcal enterotoxin B, tetanus and diphtheria toxins, and lethal factor of anthrax) toxins. It was shown that different types of immunoassays (direct, competitive, and sandwich type) could be carried out on gel microchips. As shown by confocal microscope studies, antigen-antibody interactions involving the formation of tertiary antibody-antigen-antibody complex occur in the whole volume of microchip gel elements. Sandwich assay on microchips with immobilized antibodies provided the highest sensitivity of detection (0.1 ng/ml for ricin). Antibodies labeled with fluorescent dyes, horseradish peroxidase conjugates, or biotinylated antibodies with subsequent treatment with labeled avidin were used as developing antibodies. The results of immunoassays were recorded using fluorescence, chemiluminescence, or matrix-assisted laser desorption ionization mass spectrometry directly from microchip gel elements. Gel microchips with immobilized capture antibodies were used to analyze the sample simultaneously for the presence of all six biotoxins with the same sensitivity as that for any single toxin.  相似文献   

6.
A method of the competitive immunochromatographic assay of the pesticides 2,4-D (2,4-dichlorophenoxyacetic acid) and simazine (2-chloro-4,6-bis(N-ethylamino)-1,3,5-triazine) in aqueous samples was developed. Monoclonal antibodies to these pesticides labeled with colloidal gold were used to visualize the results. The sensitivity of the 2,4-D and simazine assay is 12 ng/ml, and the time of analysis is 3–7 min. The method does not differ in sensitivity from the competitive EIA using conjugates of monoclonal antibodies to the pesticides with horseradish peroxidase; however, the time of the EIA is 1.5 h. The immunochromatographic method of the pesticide detection is available and simple and may be recommended for the development of assays of any other low-molecular compounds.  相似文献   

7.
An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.  相似文献   

8.
Immunization of BALB/c mice by horse antiserum against diphtheria made it possible to obtain IgG1 monoclonal antibodies (MoAbs) 2B7E4 specific for light chains of horse immunoglobulin (Ig). Unlike commercial preparations of anti-horse immunoglobulin antibodies, which are specific for the whole Ig molecule or its Fc-fragment, the peroxidase (HRP) conjugate of the MoAb, 2B7E4-HRP did not interact with human, mouse, rabbit, and sheep Igs, or horse albumin. The conjugate obtained was used with MoAbs against bacterial toxins and commercial horse anatoxins, as a universal reagent in sandwich enzyme immunoassay (ELISA) for bacterial toxins and anatoxins. The detection sensitivity of diphtheria toxin/anatoxin equaled 0.0005 Lf/ml; tetanus toxin and anatoxin were detected with sensitivities of 20 LD50/ml and 0.005 UI/ml, respectively. A similar sandwich ELISA for botulinum anatoxins (group measurement) allowed types A, B, and E to be detected at 0.02, 0.002, and 0.001 UI/ml, respectively; selective measurement was only possible in the case of type E anatoxin (0.001 UI/ml).  相似文献   

9.
Advances in microsystem technology have enabled protein and nucleic acid-based microarrays to be used in various applications, including the study of diseases, drug discovery, genetic screening, and clinical and food diagnostics. Analytical methods for the detection of mycotoxins, however, remain largely based on thin layer chromatography (TLC), high pressure liquid chromatography (HPLC), or enzyme-linked Immunosorbent assay (ELISA) . The aim of our work, therefore, was to transfer an immunological assay from microtitrr plates into microarray format, in order to develop a multiparametric, rapid, sensitive and inexpensive method for the detection of mycotoxins for use in food safety applications. Microarray technology enables the fast and parallel analysis of a multitude of biologically relevant parameters. Not only nucleic acid-based tests but also peptide, antigen, and antibody assays, using different formats of microarrays, have evolved within the last decade. Antibody-based microarrays provide a powerful tool that can be used to generate rapid and detailed expression profiles of a defined set of analytes in complex samples and are potentially useful for generating rapid immunological assays of food contaminants. In this paper, we report a feasibility study of the application of antibody microarrays for the simultaneous (or independent) detection of two common mycotoxins, Aflatoxin B1 and Fumonisin B1. We present the development of microarray detection of aflatoxin B1 and fumonisin B1 in standard solutions with detection limits of 3 ng/ml of AFB1 and 43 ng/ml for FB1, and have developed a competitive immunoassay in microarray format for simultaneous analyses. The quality of the microarray data is comparable to data generated by microplate-based immunoassay (ELISA), but further investigations are needed in order to characterise our method more fully. We hope that these preliminary results might suggest that further research is warranted in order to develop hapten microarrays for the immunochemical simultaneous analysis of mycotoxins, as well as for other small molecules (e.g. bacterial toxins or biological warfare agents).  相似文献   

10.
Botulism is a neuroparalytic disease caused by Clostridium botulinum, which produces seven (A-G) neurotoxins (BoNTs). The mouse bioassay is the gold standard for the detection of botulinum neurotoxins, however it requires at least 3-4 days for completion. Most of the studies were carried out in botulinum toxin A and less on type B. Attempts have been made to develop an ELISA based detection system, which is potentially an easier and more rapid method of botulinum neurotoxin detection. In the present study, the synthetic BoNT/B LC gene was constructed using PCR overlapping primers, cloned in a pET28a+ vector and expressed in E. coli BL21DE3. The maximum yield of recombinant proteins was optimized after 16 hrs of post induction at 21°C and purified the recombinant protein in soluble form. Antibodies were raised in Mice and Rabbit. The IgG antibody titer in the case of Mice was 1: 1,024,000 and Rabbit was 1: 512,000 with alum as adjuvant via intramascular route. The biological activity of the recombinant protein was confirmed by in-vitro studies using PC12 cells by the synaptobrevin cleavage, the rBoNT/B LC protein showed the maximum blockage of acetylcholine release at a concentration of 150nM rBoNT/B LC in comparison to the control cells. When the cells were incubated with rBoNT/B LC neutralized by the antisera raised against it, the acetylcholine release was equivalent to the control. IgG specific to rBoNT/B LC was purified from raised antibodies. The results showed that the developed antibody against rBoNT/B LC protein were able to detect botulinum toxin type B approximately up to 1 ng/ml. These developed high titer antibodies may prove useful for the detection of botulinum neurotoxins in food and clinical samples.  相似文献   

11.
Two monoclonal antibodies (mABs) raised against plum pox virus (PPV) were shown to recognize its D, M, and C strains. Conjugates of the antibodies with colloidal gold (CG) nanoparticles averaging 26 nm in diameter were synthesized. The binding constants of PPV with both the native and conjugated mABs were determined using a Biacore X device. The complexes between the CG-mAB conjugates and plum pox virions were examined by means of transmission electron and atomic force microscopy. Using the conjugates with optimal component ratio, an express immunochromatographic assay of PPV was developed with a detection limit of 3 ng/ml and duration of 10 min. The assay was tested for PPV detection in sam- ples of stone fruit tree leaves and demonstrated a good compatibility with the data obtained by “sandwich”-ELISA. The developed assay can be used in the field and applied for monitoring viral infection and for quarantine purposes.  相似文献   

12.
A rapid immunochromatographic assay was developed to detect botulinum neurotoxin type B (BoNT/B). The assay was based on the sandwich format using polyclonal antibody (Pab). The thiophilic gel purified anti-BoNT/B Pab was immobilized to a defined detection zone on a porous nitrocellulose membrane and conjugated to colloidal gold particles that served as a detection reagent. The BoNT/B-containing sample was added to the membrane and allowed to react with Pab-coated particles. The mixture was then passed along the porous membrane by capillary action past the Pab in the detection zone, which will bind the particles that had BoNT/B bound to their surface, giving a red colour within this detection zone with an intensity proportional to BoNT/B concentration. In the absence of BoNT/B, no immunogold was bound to the solid-phase antibody. With this method, 50 ng/ml of BoNT/B was detected in less than 10 min. The assay sensitivity can be increased by silver enhancement to 50 pg/ml. The developed BoNT/B assay also showed no cross reaction to type A neurotoxin (BoNT/A) and type E neurotoxin (BoNT/E).  相似文献   

13.
Immunoassays were developed for the simultaneous detection of staphylococcal enterotoxin B and botulinum toxoid A in buffer, with limits of detection of 0.1 ng/ml and 20 ng/ml, respectively. The toxins were also spiked and measured in a variety of food samples, including canned tomatoes, sweet corn, green beans, mushrooms, and tuna.  相似文献   

14.
Immunoassays were developed for the simultaneous detection of staphylococcal enterotoxin B and botulinum toxoid A in buffer, with limits of detection of 0.1 ng/ml and 20 ng/ml, respectively. The toxins were also spiked and measured in a variety of food samples, including canned tomatoes, sweet corn, green beans, mushrooms, and tuna.  相似文献   

15.
A novel, in vitro bioassay for detection of the botulinum type B neurotoxin in a range of media was developed. The assay is amplified by the enzymic activity of the neurotoxin's light chain and includes the following three stages: first, a small, monoclonal antibody-based immunoaffinity column captures the toxin; second, a peptide substrate is cleaved by using the endopeptidase activity of the type B neurotoxin; and finally, a modified enzyme-linked immunoassay system detects the peptide cleavage products. The assay is highly specific for type B neurotoxin and is capable of detecting type B toxin at a concentration of 5 pg ml(-1) (0.5 mouse 50% lethal dose ml(-1)) in approximately 5 h. The format of the test was found to be suitable for detecting botulinum type B toxin in a range of foodstuffs with a sensitivity that exceeds the sensitivity of the mouse assay. Using highly specific monoclonal antibodies as the capture phase, we found that the endopeptidase assay was capable of differentiating between the type B neurotoxins produced by proteolytic and nonproteolytic strains of Clostridium botulinum type B.  相似文献   

16.
A method of the competitive immunochromatographic assay of the pesticides 2,4-D (2,4-dichlorophenoxyacetic acid) and simazine (2-chloro-4,6-bis(N-ethylamino)-1,2,5-triazine) in aqueous samples was developed. Monoclonal antibodies to these pesticides labeled with colloidal gold were used to visualize the results. The sensitivity of the 2,4-D and simazine assay is 12 ng/ml, and the time of analysis is 3-7 min. The method does not differ in sensitivity from the competitive EIA using conjugates of monoclonal antibodies to the pesticides with horseradish peroxidase; however, the time of the EIA is 1.5 h. The immunochromatographic method of the pesticide detection is available and simple and may be recommended for the development of assays of any other low-molecular compounds. The English version of the paper: Russian Journal of Bioorganic Chemistry, 2004, vol. 30, no. 2; see also http://www.maik.ru.  相似文献   

17.
The production of recombinant hepatitis B virus surface antigen (rHBsAg) purified by immunoaffinity chromatography with monoclonal antibodies is used to obtain a vaccine against this virus. Monoclonal antibodies to rHBsAg from mouse ascites have been purified by Staphylococcal Protein A (SpA)--prior coupling to Sepharose CL-4B (Amersham-Bioscences, Uppsala, Sweden). A high sensitivity immunoassay has been developed for the quantification of part-per-million of SpA contaminants likely to co-purify with monoclonal antibodies obtained by Protein A affinity chromatography, in the presence of immunoglobulins. Specific sheep polyclonal Abs against SpA (SpAc1) were used as plate coating and the SpA detection was possible thanks to the conjugates of sheep Ab fragments F(ab)(2) (fSpAc1) and horseradish peroxidase (fSpAc1-peroxidase), reducing the possible unspecific interaction between SpA and Fc fragments. The immunoassay was shown to be specific for SpA contaminants. The quantification limit of the assay was 0.39 ng/ml spreading to the measurement of contamination levels less than 2 ppm of SpA in final preparations of monoclonal antibodies used for the immunopurification of pharmaceutical products, which is quite low for this application.  相似文献   

18.
The goal of this work is to explore the amplification effect of aptamer–gold nanoparticles (Au NPs) conjugates for ultrasensitive detection of large biomolecules by surface plasmon resonance (SPR). A novel sandwich immunoassay is designed to demonstrate the amplification effect of aptamer–Au NPs conjugates by using human immunoglobulin E (IgE) as model analyte. Human IgE, captured by immobilized goat anti-human IgE on SPR gold film, is sensitively detected by SPR spectroscopy with a lowest detection limit of 1 ng/ml after anti-human IgE aptamer–Au NPs conjugates is used as amplification reagent. Meanwhile, the non-specific adsorption of aptamer–Au NPs conjugates on goat anti-human IgE is confirmed by SPR spectroscopy and then it is minimized by treating aptamer–Au NPs conjugates with 6-mercaptohexan-1-ol (MCH). These results confirm that aptamer–Au NPs conjugates is a powerful sandwich element and an excellent amplification reagent for SPR-based sandwich immunoassay.  相似文献   

19.
The suitability and sensitivity of two in vitro lateral-flow assays for detecting Clostridium botulinum neurotoxins (BoNTs) in an assortment of foods were evaluated. Toxin extraction and preparation methods for various liquid, solid, and high-fat-content foods were developed. The lateral-flow assays, one developed by the Naval Medical Research Center (Silver Spring, MD) and the other by Alexeter Technologies (Gaithersburg, MD), are based on the immunodetection of BoNT types A, B, and E. The assays were found to be rapid and easy to perform with minimum requirements for laboratory equipment or skills. They can readily detect 10 ng/ml of BoNT types A and B and 20 ng/ml of BoNT type E. Compared to other in vitro detection methods, these assays are less sensitive, and the assessment of a result is strictly qualitative. However, the assay was found to be simple to use and to require minimal training. The assays successfully detected BoNT types A, B, and E in a wide variety of foods, suggesting their potential usefulness as a preliminary screening system for triaging food samples with elevated BoNT levels in the event of a C. botulinum contamination event.  相似文献   

20.
An amplified enzyme-linked immunosorbent assay (ELISA) for the detection of Clostridium botulinum complex neurotoxins was evaluated for its ability to detect these toxins in food. The assay was found to be suitable for detecting type A, B, E, and F botulinum neurotoxins in a variety of food matrices representing liquids, solid, and semisolid food. Specific foods included broccoli, orange juice, bottled water, cola soft drinks, vanilla extract, oregano, potato salad, apple juice, meat products, and dairy foods. The detection sensitivity of the test for these botulinum complex serotypes was found to be 60 pg/ml (1.9 50% lethal dose [LD50]) for botulinum neurotoxin type A (BoNT/A), 176 pg/ml (1.58 LD50) for BoNT/B, 163 pg/ml for BoNT/E (4.5 LD50), and 117 pg/ml for BoNT/F (less than 1 LD50) in casein buffer. The test could also readily detect 2 ng/ml of neurotoxins type A, B, E, and F in a variety of food samples. For specificity studies, the assay was also used to test a large panel of type A C. botulinum, a smaller panel of proteolytic and nonproteolytic type B, E, and F neurotoxin-producing Clostridia, and nontoxigenic organisms using an overnight incubation of toxin production medium. The assay appears to be an effective tool for large-scale screening of the food supply in the event of a botulinum neurotoxin contamination event.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号