首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Wegener J  Keese CR  Giaever I 《BioTechniques》2002,33(2):348, 350, 352 passim
Here we describe various experiments that address the efficiency of loading extracellular probes into the cytoplasm of adherent mammalian cells (normal rat kidney, Madin-Darby canine kidney, and African green monkey) by means of in situ electroporation. Subsequent cell recovery from the electroporation pulse was monitored electrically in real time for each condition. In this study, small, gold-film electrodes (5 x 10(-4) cm2) are used as culture substrates and at the same time as an electrode for both the application of the electroporating voltage pulse and the noninvasive electrical monitoring of cell recovery, using a technique referred to as ECIS. Electroporation has been performed by using ac sinusoidal voltage pulses of varying frequency, amplitude, and duration. Permeabilization and re-closure of the plasma membrane were evaluated by the uptake of the fluorescence probe, Lucifer Yellow, from the extracellularfluid. With the experimental setup described here, efficient electroporation was achieved with voltages less than 5 V. Using ECIS, we followed the morphological response of the cells to the electricfield-induced membrane permeabilization. For optimized electroporation conditions, cell recovery was completed in less than 1 h. The introduction of membrane-impermeable substances by electroporation and in situ monitoring of the cellular response mayfind many applications in cell biology.  相似文献   

2.
This article describes the optimization of an experimental technique referred to as electric cell-substrate impedance sensing (ECIS) to monitor attachment and spreading of mammalian cells quantitatively and in real time. The method is based on measuring changes in AC impedance of small gold-film electrodes deposited on a culture dish and used as growth substrate. Based on experimental data and theoretical considerations we demonstrate that high-frequency capacitance measurements (f = 40 kHz) are most suited to follow the increasing surface coverage of the electrode due to cell spreading. The excellent time resolution of the method allowed an in-depth analysis of cell spreading kinetics under various experimental conditions. Using ECIS we studied the attachment and spreading of epithelial MDCK cells (strain II) on different protein coatings, and investigated the influence of divalent cations on spreading kinetics. We quantified the inhibitory effect of soluble peptides that mimic the recognition sequence of fibronectin and other extracellular matrix proteins (RGDS). We also applied the ECIS technique to monitor the detachment of confluent fibroblastic cell layers (WI38/VA-13) by means of these peptides.  相似文献   

3.
Apoptosis is a strictly regulated and genetically encoded cell 'suicide' that may be triggered by cytokines, depletion of growth factors or certain chemicals. It is morphologically characterized by severe alterations in cell shape like cell shrinkage and disintegration of cell-cell contacts. We applied a non-invasive electrochemical technique referred to as electric cell-substrate impedance sensing (ECIS) in order to monitor the apoptosis-induced changes in cell shape in an integral and quantitative fashion with a time resolution in the order of minutes. In ECIS the cells are grown directly on the surface of small gold-film electrodes (d = 2 mm). From readings of the electrical impedance of the cell-covered electrode, performed with non-invasive, low amplitude sensing voltages, it is possible to deduce alterations in cell-cell and cell-substrate contacts. To improve the sensitivity of this impedance assay we used endothelial cells derived from cerebral micro-vessels as cellular model systems since these are well known to express electrically tight intercellular junctions. Apoptosis was induced by cycloheximide (CHX) and verified by biochemical and cytological assays. The time course of cell shape changes was followed with unprecedented time resolution by impedance readings at 1 kHz and correlated with biochemical parameters. From impedance readings along a broad frequency range of 1-10(6) Hz we could assign the observed impedance changes to alterations on the subcellular level. We observed that disassembly of barrier-forming tight junctions precedes changes in cell-substrate contacts and correlates strongly with the time course of protease activation.  相似文献   

4.
A PDMS-glass based micro-device was designed and fabricated with 12 coplanar impedance sensors integrated for electrical cell-substrate impedance sensing (ECIS). The sensitivity and frequency characteristics of the sensors were investigated both theoretically (equivalent circuit model) and experimentally for the commonly used micro-electrode dimension scale (20-80 microm). The experimental results matched well with the theoretical model analysis and revealed that, within this micro-electrode dimension scale, as the electrode width decreased or as the total electrode length decreased the sensitivity of sensor increased over the whole sensing frequency range, whilst electrode to electrode distance had no influence on sensitivity. Through our frequency characteristics analysis, the whole frequency range could be divided into four parts. New functions describing the dominant components in each frequency range were defined and validated experimentally, and could be used to explain the phenomenon of an ECIS sensing frequency window. The contribution to the impedance measurement of cells growing on the edges of the electrodes was determined for the first time. Finally, novel proposals for ECIS sensor design and ECIS measurements were presented.  相似文献   

5.
In situ electroporation of adherent cells provides significant advantages with respect to electroporation systems for suspension cells, such as causing minimal stress to cultured cells and simplifying and saving several steps within the process. In this study, a new electrode assembly design is shown and applied to in situ electroporate adherent cell lines growing in standard multiwell plates. We designed an interdigitated array of electrodes patterned on copper with printed circuit board technology and covered with nickel/gold. Small interelectrode distances were used to achieve effective electroporation with low voltages. Epoxy-based microseparators were constructed to avoid direct contact with the cells and to create more uniform electric fields. The device was successful in the electropermeabilization of two different adherent cell lines, C2C12 and HEK 293, as assessed by the intracellular delivery of the fluorescent dextran FD20S. Additionally, as a collateral effect, we observed cell electrofusion in HEK 293 cells, thus making this device also useful for performing cell fusion. In summary, we show the effectiveness of this minimally invasive device for electroporation of adherent cells cultured in standard multiwell plates. The cheap technologies used in the fabrication process of the electrode assembly indicate potential use as a low-cost, disposable device.  相似文献   

6.
Electric Cell-substrate Impedance Sensing (ECIS) is an in vitro impedance measuring system to quantify the behavior of cells within adherent cell layers. To this end, cells are grown in special culture chambers on top of opposing, circular gold electrodes. A constant small alternating current is applied between the electrodes and the potential across is measured. The insulating properties of the cell membrane create a resistance towards the electrical current flow resulting in an increased electrical potential between the electrodes. Measuring cellular impedance in this manner allows the automated study of cell attachment, growth, morphology, function, and motility. Although the ECIS measurement itself is straightforward and easy to learn, the underlying theory is complex and selection of the right settings and correct analysis and interpretation of the data is not self-evident. Yet, a clear protocol describing the individual steps from the experimental design to preparation, realization, and analysis of the experiment is not available. In this article the basic measurement principle as well as possible applications, experimental considerations, advantages and limitations of the ECIS system are discussed. A guide is provided for the study of cell attachment, spreading and proliferation; quantification of cell behavior in a confluent layer, with regard to barrier function, cell motility, quality of cell-cell and cell-substrate adhesions; and quantification of wound healing and cellular responses to vasoactive stimuli. Representative results are discussed based on human microvascular (MVEC) and human umbilical vein endothelial cells (HUVEC), but are applicable to all adherent growing cells.  相似文献   

7.
P M Ghosh  C R Keese    I Giaever 《Biophysical journal》1993,64(5):1602-1609
When an electrical potential of order one volt is induced across a cell membrane for a fraction of a second, temporary breakdown of ordinary membrane functions may occur. One result of such a breakdown is that molecules normally excluded by the membrane can now enter the cells. This phenomenon, generally referred to as electropermeabilization, is known as electroporation when actual pores form in the membrane. This paper presents a unique approach to the measurement of pore formation and closure in anchored mammalian cells. The cells are cultured on small gold electrodes, and by constantly monitoring the impedance of the electrode with a low-amplitude AC signal, small changes in cell morphology, cell motion, and membrane resistance can be detected. Because the active electrode is small, the application of a few volts across the cell-covered electrode causes pore formation in the cell membrane. In addition, the heat transfer is very efficient, and the cells can be porated in their regular growth medium. By this method, the formation and resealing of pores due to applied electric fields can be followed in real time for anchorage-dependent cells.  相似文献   

8.
Correlated motion and oscillation of neighboring cells in vitro   总被引:2,自引:0,他引:2  
It has long been realized that fibroblastic and epithelial cells establish recognizable patterns in tissue culture. This behavior implies that neighboring cells interact with one another to produce organized populations. Interaction between cells that are separated by many intervening cells is also possible and is demonstrated here using a special configuration of a biosensor referred to as electric cell-substrate impedance sensing (ECIS). Normally the electrical impedance of a single electrode covered with a confluent cell layer is measured, and the morphological changes of the cells are reflected in the impedance. In this case the cells are cultured on two closely spaced electrodes whose impedances are measured independently as a function of time, and communication between the cell populations is revealed as a correlation between these two time series. We also report for the first time another striking manifestation of dynamic cell interaction, where confluent layers of Madin-Darby canine kidney cells (MDCK) on a single electrode are observed to oscillate in synchrony with a period of approximately 2.5 h.  相似文献   

9.
It has long been realized that fibroblastic and epithelial cells establish recognizable patterns in tissue culture. This behavior implies that neighboring cells interact with one another to produce organized populations. Interaction between cells that are separated by many intervening cells is also possible and is demonstrated here using a special configuration of a biosensor referred to as electric cell-substrate impedance sensing (ECIS). Normally the electrical impedance of a single electrode covered with a confluent cell layer is measured, and the morphological changes of the cells are reflected in the impedance. In this case the cells are cultured on two closely spaced electrodes whose impedances are measured independently as a function of time, and communication between the cell populations is revealed as a correlation between these two time series. We also report for the first time another striking manifestation of dynamic cell interaction, where confluent layers of Madin-Darby canine kidney cells (MDCK) on a single electrode are observed to oscillate in synchrony with a period of approximately 2.5 h.  相似文献   

10.
Using an electrical measurement known as electric cell-substrate impedance sensing (ECIS), we have recorded the dynamics of viral infections in cell culture. With this technique, cells are cultured on small gold electrodes where the measured impedance mirrors changes in attachment and morphology of cultured cells. As the cells attach and spread on the electrode, the measured impedance increases until the electrode is completely covered. Viral infection inducing cytopathic effect results in dramatic impedance changes, which are mainly due to cell death. In the current study, two different fish cell lines have been used: chinook salmonid embryonic (CHSE-214) cells infected with infectious pancreatic necrosis virus (IPNV) and epithelioma papulosum cyprini (EPC) carp cells infected with infectious hematopoeitic necrosis virus (IHNV). The impedance changes caused by cell response to virus are easily measured and converted to resistance and capacitance. An approximate linear correlation between log of viral titer and time of cell death was determined.  相似文献   

11.
The discovery of RNAi pathway in eukaryotes and the subsequent development of RNAi agents, such as siRNA and shRNA, have achieved a potent method for silencing specific genes1-8 for functional genomics and therapeutics. A major challenge involved in RNAi based studies is the delivery of RNAi agents to targeted cells. Traditional non-viral delivery techniques, such as bulk electroporation and chemical transfection methods often lack the necessary spatial control over delivery and afford poor transfection efficiencies9-12. Recent advances in chemical transfection methods such as cationic lipids, cationic polymers and nanoparticles have resulted in highly enhanced transfection efficiencies13. However, these techniques still fail to offer precise spatial control over delivery that can immensely benefit miniaturized high-throughput technologies, single cell studies and investigation of cell-cell interactions. Recent technological advances in gene delivery have enabled high-throughput transfection of adherent cells14-23, a majority of which use microscale electroporation. Microscale electroporation offers precise spatio-temporal control over delivery (up to single cells) and has been shown to achieve high efficiencies19, 24-26. Additionally, electroporation based approaches do not require a prolonged period of incubation (typically 4 hours) with siRNA and DNA complexes as necessary in chemical based transfection methods and lead to direct entry of naked siRNA and DNA molecules into the cell cytoplasm. As a consequence gene expression can be achieved as early as six hours after transfection27. Our lab has previously demonstrated the use of microelectrode arrays (MEA) for site-specific transfection in adherent mammalian cell cultures17-19. In the MEA based approach, delivery of genetic payload is achieved via localized micro-scale electroporation of cells. An application of electric pulse to selected electrodes generates local electric field that leads to electroporation of cells present in the region of the stimulated electrodes. The independent control of the micro-electrodes provides spatial and temporal control over transfection and also enables multiple transfection based experiments to be performed on the same culture increasing the experimental throughput and reducing culture-to-culture variability. Here we describe the experimental setup and the protocol for targeted transfection of adherent HeLa cells with a fluorescently tagged scrambled sequence siRNA using electroporation. The same protocol can also be used for transfection of plasmid vectors. Additionally, the protocol described here can be easily extended to a variety of mammalian cell lines with minor modifications. Commercial availability of MEAs with both pre-defined and custom electrode patterns make this technique accessible to most research labs with basic cell culture equipment.  相似文献   

12.
The development of neuron-microelectrode interfaces (neurochips) is highly desirable for the non-invasive recording of the cellular response to neuroactive drugs as well as the electrical stimulation of nervous tissue by implantable electrodes. A prerequisite for neuron-to-electrode signal transmission (NEST) is the formation of synapse-like contacts between the neuronal cell and the conductive surface of a microelectrode array. We attempted synapse formation by neuronal differentiation of rat pheochromocytoma cells (PC12) and blastocyst-derived murine embryonic stem cells (ES-J1) on interdigitated microelectrode arrays that were made of gold (Au), platinum (Pt), or indium tin oxide (ITO). PC12 or ES cells were in vitro differentiated by incubation with nerve growth factor (NGF) and forskolin, or by serum deprivation and treatment with basic fibroblast growth factor (FGF-2), respectively. On top of ITO electrodes, the neuronal cells extended extremely long processes that terminated in pili-like contact structures, which is typical for growth cone formation. ES cells differentiated into neurons as verified by immunofluorescence staining of MAP-2 and developed synapse-like junctions with the ITO electrode surface as indicated by synaptophysin staining. Differentiated PC12 and ES cells showed bona fide morphological characteristics of synaptic growth cones that were unprecedented in tissue culture. Cones formed by PC12 cells could be stimulated with KCI and carbachol as shown by uptake of FM1-43, a fluorescent marker for synaptic vesicle formation. In contrast to Electrical Cell Impedance Spectroscopy (ECIS) recordings, AC impedance spectrometry with differentiated PC12 cells settled on interdigitated microelectrode arrays revealed lower AC impedance than that with undifferentiated cells, indicating that the complex impedance is dependent on ion fluxes at the neuron-to-electrode contact surface.  相似文献   

13.
The blood-brain barrier (BBB) is composed of the cerebral microvascular endothelium, which, together with astrocytes, pericytes, and the extracellular matrix (ECM), contributes to a "neurovascular unit". It was our objective to clarify the impact of endogenous extracellular matrices on the barrier function of BBB microvascular endothelial cells cultured in vitro. The study was performed in two consecutive steps: (i) The ECM-donating cells (astrocytes, pericytes, endothelial cells) were grown to confluence and then removed from the growth substrate by a protocol that leaves the ECM behind. (ii) Suspensions of cerebral endothelial cells were seeded on the endogenous matrices and barrier formation was followed with time. In order to quantify the tightness of the cell junctions, all experiments were performed on planar gold-film electrodes that can be used to read the electrical resistance of the cell layers as a direct measure for endothelial barrier function (electric cell-substrate impedance sensing, ECIS). We observed that endogenously isolated ECM from both, astrocytes and pericytes, improved the tightness of cerebral endothelial cells significantly compared to ECM that was derived from the endothelial cells themselves as a control. Moreover, when cerebral endothelial cells were grown on extracellular matrices produced by non-brain endothelial cells (aorta), the electrical resistances were markedly reduced. Our observations indicate that glia-derived ECM - as an essential part of the BBB - is required to ensure proper barrier formation of cerebral endothelial cells.  相似文献   

14.
In this paper, impedance measurement of electrolyte-insulator-semiconductor (EIS) structure with high spatial resolution was proposed to monitor cell adhesion. The light addressing ability of this work overcomes the geometrical restrict of cell culture on conventional impedance detection devices such as interdigitated electrode (IDE) and electric cell-substrate impedance sensing (ECIS). Instead of studying cells on predetermined sites of IDE and ECIS, cells cultured anywhere on EIS sensor surface can be addressed and selected as target cells. Principle and primary models for high resolution impedance detection were described and tested by experiments. The EIS sensor was investigated in terms of its intrinsic characteristics, like impedance behavior, voltage characteristic, frequency dependency and photovoltaic effect. Optimized working condition was studied for cell experiments. Cell adhesion under treatment of 0.1% Triton X-100 was monitored using rat kidney cells as the source. Results showed good sensitivity (10% change of impedance) and resolution (40 μm) for cell adhesion impedance detection and suggested this work should be suitable for monitoring cell impedance. Further improvements on sensitivity, spatial resolution were discussed as well as the further applications for single cell monitoring and cell adhesion imaging.  相似文献   

15.
Reversible electropermeabilization (or electroporation) of cell membranes is a very efficient method for intracellular delivery of xenomolecules, particularly of DNA. In the case of anchorage-dependent cells, however, enzymatic or mechanical detachment from the substratum is required prior to electropulsing. This can damage the plasma membrane and lead to low transfection yields. Here we present an efficient method for in situ electroporation of mammalian cells while they are attached to a solid substratum. For this purpose an electroporation chamber was constructed that housed a cell culture insert with a cell monolayer grown on a porous filter. By real-time monitoring the transmonolayer resistance, the field pulse parameters resulting in transient and reversible permeabilization of cell membranes were determined for two adherent cell lines, which were found to differ markedly in their sensitivity to electropulsing. Based on the transmonolayer resistance data, the pulsing conditions for optimum electrotransfection of two murine cell lines with plasmid DNA could be established in a very short time. The transfection yield and gene expression were significantly higher in cell monolayers facing the cathode compared to those exposed to field pulses of the reverse direction. This might be due to contribution of the electrophoresis to the translocation of the polyanionic plasmid DNA across the electropermeabilized cell membrane. The experimental setup presented here appears to be a promising tool not only for rapid optimization of in situ electrotransfection of anchorage-dependent cells but also for studying the molecular/biophysical mechanisms of the membrane breakdown and resealing.  相似文献   

16.
Peptide therapeutics are of increasing interest due to their biological specificity. We used a simple technique to study the efficacy of inducing peptides into adherent chondrocytes by transiently permeabilizing the membrane with electric pulses (in situ electroporation). Mechano-growth factor (MGF) was selected as a model peptide. FITC-labeled MGF was added to cultures of adherent primary chondrocytes grown on ITO coated glass slides. Cells were subjected to 3–9 pulses of 175–275 V and evaluated by flow cytometry. Under optimal conditions, an electroporation efficiency of close to 50% could be achieved. This technique can be used to study the functional domains of intracellular peptides, peptide inhibition of signal transduction and intracrine-mediated effects of peptides in adherent cells.  相似文献   

17.
We previously developed a technique, termed in situ electroporation, where nonpermeant molecules are introduced through an electrical pulse into adherent cells, while they grow on electrically conductive, optically transparent, indium-tin oxide (ITO). Careful control of the electric field intensity results in essentially 100% of the cells taking up the introduced material, without any detectable effect upon the physiology of the cell, presumably because the pores reseal rapidly so that the cellular interior is restored to its original state. Electroporation of radioactive material is faced with two important considerations: (1) potential for exposure of personnel to irradiation, and (2) the requirement for electroporation of a large number of cells. In this report, we describe a modification in the geometry of the slides and electrodes which permits the use of inexpensive ITO-coated glass of lower conductivity that can be discarded after use, to electroporate large numbers of cells using a minimum volume of radioactive nucleotide solution. The results demonstrate that, using this assembly, the determination of the Ras-bound GTP/GTP+GDP ratios through electroporation of [alpha32P]GTP can be conducted using approximately five times lower amounts of isotope than in previous designs. Moreover, this assembly permits efficient upscaling, which makes the determination of Ras-GTP binding in cells which are deficient in Ras activity possible. In addition, we demonstrate the labeling of two viral phosphoproteins--the Simian Virus 40 Large Tumor antigen, and Adenovirus E1A--through [gamma32P]ATP electroporation using this setup. In both cases, electroporation of the nucleotide can achieve a great increase in the efficiency and specificity of labeling compared to the addition of [32P]-orthophosphate to the culture medium, presumably because the immediate phosphate donor nucleotide itself is introduced, which can directly bind to the target proteins.  相似文献   

18.
De Blasio BF  Laane M  Walmann T  Giaever I 《BioTechniques》2004,36(4):650-4, 656, 658 passim
A new method combining optical and electrical impedance measurements is described that enables submicroscopic cell movements to be monitored. The cells are grown on small gold electrodes that are transparent to light. This modified electrical cell-substrate impedance sensor (ECIS) allows simultaneous microscopic recording of both growth and motility, thus enabling cell confluence on the electrodes to be systematically correlated to the impedance in regular time intervals of seconds and for extended periods of time. Furthermore, the technique provides an independent measure of monolayer cell densities that we compare to calculated values from a theoretical model. We have followed the attachment and spreading behavior of epithelial Madin-Darby canine kidney strain I (MDCK-I) cell cultures on microelectrodes for up to 40 h. The studies reveal a high degree of correlation between the measured resistance at 4 kHz and the corresponding cell confluence in 4- to 6-h intervals with typical linear cross-correlation factors of r equaling approximately 0.9. In summary, the impedance measured with the ECIS technique provides a good quantitative measure of cell confluence.  相似文献   

19.
Electrochemical impedance spectroscopy was tested to monitor the cell attachment and the biofilm proliferation in order to identify characteristic events induced on the metal surface by Gram-negative (Pseudomonas aeruginosa PAO1) and Gram-positive (Bacillus subtilis) bacteria strains. Electrochemical impedance spectra of AISI 304 electrodes during cell attachment and initial biofilm growth for both strains were obtained. It can be observed that the resistance increases gradually with the culture time and decreases with the biofilm detachment. So, the applicability of electric cell-substrate impedance sensing (ECIS) for studying the attachment and spreading of cells on a metal surface has been demonstrated. The biofilm formation was also characterized by the use of scanning electron microscopy and confocal laser scanning microscopy and COMSTAT image analysis. The electrochemical results roughly agree with the microscope image observations. The ECIS technique used in this study was used for continuous real-time monitoring of the initial bacterial adhesion and the biofilm growth. It provides a simple and non-expensive electrochemical method for in vitro assessment of the presence of biofilms on metal surfaces.  相似文献   

20.
An on-line and continuous technique based on electric cell-substrate impedance sensing (ECIS) was developed for measuring the concentration and time response function of fibroblastic V79 cells exposed to mercury chloride and 1,3,5-trinitrobenzene (TNB). Attachment, spreading and proliferation of V79 fibroblastic cells cultured on a microarray of small gold electrodes precoated with fibronectin were detected as resistance changes. The response function was derived to reflect the resistance change as a result of cell attachment, spreading, mitosis and cytotoxicity effect. Exposure of V79 cells to mercury chloride or TNB led to alterations in cell behavior, and therefore, chemical cytotoxicity was easily screened by measuring the response function of the attached and spread cells in the presence of inhibitor. The half inhibition concentration, the required concentration to achieve 50% inhibition, was obtained from the response function to provide information about cytotoxicity during the course of the assay. A simple mathematical model was developed to describe the responses of ECIS that were related to the attachment, spreading, and proliferation of V79 fibroblastic cells. The novel results of this paper are mainly characterized by the systematic study of several parameters including the cell number, detection limit, sensor sensitivity, and cytotoxicity, and they may motivate further research and study of ECIS sensors.  相似文献   