首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The aim of this study was to develop a rapid method to measure alpha-fetoprotein (AFP) in human serum by use of one-step sandwich enzyme-linked immunosorbent assay (ELISA)-based immunobiosensor with disposable screen-printed carbon electrode technology. Prussian blue (PB) was deposited using cyclic voltammetry (CV) on the surface of electrode to catalyze H202 from the reaction of glucose oxidase. It took only about 30 min to complete the whole experimental procedure through flow injection analysis (FIA). A detection range obtained is in the range from 5 to 500 ng/ml AFP. This detection seems to be quick, reliable and practical.  相似文献   

2.
A new flow-through electrochemical immunosensor was designed for sensitive detection of alpha-fetoprotein (AFP) in human serum by using nanogold-functionalized magnetic graphene nanosheets as immunosensing probes. Initially, amino functionalized magnetic beads were covalently immobilized on the surface of graphene oxide nanosheets (MGPs), then nanogold particles were adsorbed on the amino groups of the MGPs to construct GoldMag nanocomposites functionalized graphene nanosheets (GMGPs), and then horseradish peroxidase-anti-AFP conjugates (HRP-anti-AFP) were assembled onto the surface of nanogold particles (bio-GMGP). With the aid of an external magnet, the formed bio-GMGPs were attached onto the base electrode in the flow system. With a non-competitive immunoassay format, the injected sample containing AFP antigens was produced transparent immunoaffinity reaction with the immobilized HRP-anti-AFP on the bio-GMGPs. The formed immunocomplex inhibited partly the active center of HRP, and decreased the labeled HRP toward the reduction of H(2)O(2). The performance and factors influencing the performance of the immunosensor were investigated in detail. Under optimal conditions, the electrochemical immunosensor displayed a wide working range of 0.01-200 ng mL(-1) with a low detection limit (LOD) of 1.0 pg mL(-1) AFP (at 3s(B)). Intra- and inter-assay coefficients of variation (CV) were below 10%. In addition, the methodology was validated with real serum samples, receiving a good correlation with the results obtained from commercially available electrochemiluminescence automated analyzer.  相似文献   

3.
This paper describes a miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion. The glass fiber membrane was functionally modified with gamma-glycidoxypropyltrimethoxysilane and sodium thiosulfate and was used for separation of protein. Anti-human chorionic gonadotrophin (HCG) immunoglobulin G (IgG) antibody conjugated with ferrocenemonocarboxylic acid (Fc), namely, Fc-conjugated IgG (Fc-IgG), was used as a novel analytical reagent. HCG and Fc-IgG complexes were separated from free Fc-IgG based on differences in isoelectric point (pI) using the glass fiber membrane modified with a thiosulfonyl acid functional group. The assay yields a linear relationship between current and HCG concentration in the range of 0-2000 mIU/mL. This simple technique enables the assay of HCG within 2 min. The modified glass fiber membrane was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free Fc-IgG. Free Fc-IgG recovered in this manner could be reused up to eight times without significant decreases in sensitivity. This miniaturized amperometric flow immunoassay requires only minute quantities of serum and generates highly reproducible results.  相似文献   

4.
The aim of this study was to develop a simple, rapid and highly sensitive sensor for measuring the rare sugar d-psicose. The proposed system adopts amperometric flow analysis and two consecutive enzyme reactions consisting of a reactor packed with d-tagatose 3-epimerase (DTE)-immobilized beads, which converts d-psicose to d-fructose, and a carbon-paste electrode containing d-fructose dehydrogenase (DFDH). In order to fabricate a robust sensor system, various experimental parameters were optimized including the buffer composition, flow rate for the two enzyme reactions and the size of micro-flow cell. The developed sensor responded linearly to d-psicose concentration in the range from 0.08 to 50mM (R(2)=0.988). The signal/noise ratio was 3.0 for the 0.08 mM d-psicose solution, and the relative standard deviations were 1.7 (n=20) and 2.6% (n=20) for the 10 and 20mM d-psicose solutions, respectively. One round of assay was completed within 8 min. Our results suggest that the sensor can be used not only for the detection of d-psicose in food samples but also for monitoring d-psicose within the environment. Moreover, the sensor system can be applied to the detection of many other rare sugars by using the same measurement principle.  相似文献   

5.
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H(2)O(2) system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N=3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA.  相似文献   

6.
We developed a highly sensitive flow injection/amperometric biosensor for the detection of organophosphate pesticides (OPs) using layered double hydroxides (LDHs) as the immobilization matrix of acetylcholinesterase (AChE). LDHs provided a biocompatible microenvironment to keep the bioactivity of AChE, due to the intrinsic properties of LDHs (such as a regular structure, good mechanical, chemical and thermal stabilities, and swelling properties). By integrating the flow injection analysis (FIA) with amperometric detection, the resulting AChE-LDHs modified electrode greatly catalyzed the oxidation of the enzymatically generated thiocholine product, and facilitated the detection automation, thus increasing the detection sensitivity. The analytical conditions for the FIA/amperometric detection of OPs were optimized by using methyl parathion (MP) as a model. The inhibition of MP was proportional to its concentration ranging from 0.005 to 0.3μgmL(-1) and 0.3 to 4.0μgmL(-1) with a detection limit 0.6ngmL(-1) (S/N=3). The developed biosensor exhibited good reproducibility and acceptable stability.  相似文献   

7.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

8.
A hydrophilic matrix of periodate-oxidized dextran was used as a double-sided linker to covalently immobilize Staphylococcus aureus protein A (SpA) molecules onto a poly-L-lysine-modified piezoelectric crystal surface to improve their stability, activity, and binding specificity with human immunoglobulin G (IgG) in flow injection assays. The prepared sensing crystals displayed best sensitivity and reusability at a flow rate of 140 microL/min. A human IgG concentration as low as 0.3 nM can be detected by this system. Up to 19 successive assay repetitions were achieved without significant loss of sensitivity using the same crystal. The analysis of adsorption kinetics indicates that such a preparation can greatly increase the amount of available active human IgG binding sites on immobilized SpA. Hardly any response arising from unspecific binding was detected. In addition, the sensing crystal prepared by this method was found to retain activity better than one prepared via direct deposition when stored in either wet or dry states. Finally, the prepared SpA-coated crystals were applied to the affinity immobilization of polyclonal goat anti-Schistosoma japonicum glutathione-S-transferase (GST) and were able to subsequently detect GST and its genetically engineered mutant either in a purified form or in the crude cell lysate.  相似文献   

9.
This work describes the electrochemical and electrocatalytic properties of carbon ceramic electrode (CCE) modified with lead nitroprusside (PbNP) nanoparticles as a new electrocatalyst material. The structure of deposited film on the CCE was characterized by energy dispersive X-ray (EDX), Fourier transform infrared (FTIR), and scanning electron microscopy (SEM). The cyclic voltammogram (CV) of the PbNP modified CCE showed two well-defined redox couples due to [Fe(CN)5NO]3−/[Fe(CN)5NO]2− and PbIV/PbII redox reactions. The modified electrode showed electrocatalytic activity toward the oxidation of l-cysteine and was used as an amperometric sensor. Also, to reduce the fouling effect of l-cysteine and its oxidation products on the modified electrode, a thin film of Nafion was coated on the electrode surface. The sensor response was linearly changed with l-cysteine concentration in the range of 1 × 10−6 to 6.72 × 10−5 mol L−1 with a detection limit (signal/noise ratio [S/N] = 3) of 0.46 μM. The sensor sensitivity was 0.17 μA (μM)−1, and some important advantages such as simple preparation, fast response, good stability, interference-free signals, antifouling properties, and reproducibility of the sensor for amperometric determination of l-cysteine were achieved.  相似文献   

10.
An amperometric tubular cell involving composite biosensors for the determination of beta-d-glucose in a flow injection analysis (FIA) system is proposed. Diverse configurations and parameters are evaluated to improve the system's response. The configuration producing less noise resulted when the biosensor was located closer to the auxiliary electrode, which also required coupling both electrodes within the system under a continuous flow regime. Further, we report on the influence of the active area of the biosensor and of the flow rate used. Statistical analyses of the data revealed two regions with a linear response range for the determination of beta-d-glucose, with a detection limit of 4.7 x 10(-4) M and in the low concentration region a sensitivity of 17.46 +/- 0.12 microAM(-1). At the beta-d-glucose concentrations studied there was no evidence of enzymatic saturation. An increment on the ionic strength of the sample and carrier passing through the analysis system decreases its sensitivity. The reproducibility of the analytical system in terms of its standard deviation was 2.9% with a 95% confidence level, having a lifetime that lasted at least 100 days. beta-d-Glucose was determined in different commercial medical glucose-containing solutions, the experimental results are in good agreement with those reported by the manufacturer.  相似文献   

11.
A carbon paste electrode modified with the adsorbed products of the electrochemical oxidation of adenosine triphosphate is described. The electrode was applied to the amperometric electrocatalytic detection of the reduced form of both nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate. The catalytic oxidation current shows a linear dependence on the concentration of the reduced form of nicotinamide adenine dinucleotide up to 1x10(-4)M, with a detection limit of 5x10(-9)M. Modified carbon paste electrodes were coated with an electrogenerated film of nonconducting poly(o-phenylenediamine) to obtain a stable amperometric response for at least 150h. In addition to static measurements, determination of both reduced cofactors was carried out in a flow injection analysis system with a thin-layer amperometric detection cell. The electrocatalytic monitoring of reduced nicotinamide adenine dinucleotide phosphate was applied to flow injection measurement of isocitrate dehydrogenase activity in serum. The results were in good agreement with those for the standard spectrophotometric test kit. The proposed method consumed less time and reagents and provided better precision than the standard method.  相似文献   

12.
In this work, uniform and stable multi-walled carbon nanotubes (MWCT) and chemically reduced graphene (GR) composite electrode interface was fabricated by using layer-by-layer assembly method. The performances of these GR-MWCT assembled electrode interfaces were studied by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). It was demonstrated that the assembled composite film significantly improved the interfacial electron transfer rate compared with that of GR or MWCT modified electrode. Based on the GR-MWCT assembled interface, a sandwich-type electrochemical immunosensor was constructed using human IgG as a model target. In this assay, human IgG was fixed as the target antigen, the HRP-conjugated IgG as the probing antibody and hydroquinone as the electron mediator. The detection limit of the immunosensor was 0.2 ng mL(-1) (signal-to-noise ratio of 3). A good linear relationship between the current signals and the concentrations of Human IgG was achieved from 1 ng mL(-1) to 500 ng mL(-1). Moreover, this electrochemical immunosensor exhibited excellent selectivity, stability and reproducibility, and can be used to accurately detect IgG concentration in human serum samples. The results suggest that the electrochemical immunosensor based on GR-MWCT assembled composite will be promising in the point-of-care diagnostics application of clinical screening of multiple diseases.  相似文献   

13.
In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc–IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc–IgG. Antibody–antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pI) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0–2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results.  相似文献   

14.
Carbon paste wax electrodes incorporating thermophilic L-glutamate dehydrogenase, NADP and a polymeric toluidine blue O (poly-TBO) mediator have been characterised for the amperometric determination of L-glutamate at 313-318 K in a flow injection analysis (FIA) system. The biosensors exhibit good sensitivity, mechanical stability and reproducibilty, unlike carbon paste- or carbon wax-based electrodes under the same conditions. The carbon paste wax electrode responds linearly to L-glutamate up to 40 mM, the detection limit is 0.3 mM and the RSD (n = 10) for 5 mM L-glutamate was 7.6%. The response to some potential interferents has been quantified. Addition of finely ground hexaammineruthenium (III) trichloride ([Ru(NH3)6]Cl3) to the carbon paste wax electrodes decreases the FIA peak width and increases the peak current. The metal complex appears to accelerate the rate of oxidation of NAD(P)H by poly-TBO.  相似文献   

15.
Cobalt hydroxide nanoparticles were prepared onto a carbon ceramic electrode (CHN|CCE) using the cyclic voltammetry (CV) technique. The modified electrode was characterized by X-ray diffraction and scanning electron microscopy. The results showed that CHN with a single-layer structure was uniformly electrodeposited on the surface of CCE. The electrocatalytic activity of the modified electrode toward the oxidation of insulin was studied by CV. CHN|CCE was also used in a homemade flow injection analysis system for insulin determination. The limit of detection (signal/noise [S/N] = 3) and sensitivity were found to be 0.11 nM and 11.8 nA/nM, respectively. Moreover, the sensor was used for detection of insulin in human serum samples. This sensor showed attractive properties such as high stability, reproducibility, and high selectivity.  相似文献   

16.
A new disposable amperometric bi-enzyme sensor system for detecting phenols has been developed. The phenol sensor developed uses horseradish peroxidase modified screen-printed carbon electrodes (HRP-SPCEs) coupled with immobilized tyrosinase prepared using poly(carbamoylsulfonate) (PCS) hydrogels or a poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) matrix. Optimization of the experimental parameters has been performed with regard to buffer composition, pH, operating potential and storage stability. A co-operative reaction involving tyrosinase and HRP occurs at a potential of -50 mV versus Ag/AgCl without the requirement for addition of extraneous H(2)O(2), thus, resulting in a very simple and efficient system. Comparison of the electrode responses with the 4-aminoantipyrine standard method for phenol sample analysis indicated the feasibility of the disposable sensor system for sensitive "in-field" determination of phenols. The most sensitive system was the tyrosinase immobilized HRP-SPCE using PCS, which displayed detection limits for phenolic compounds in the lower nanomolar range e.g. 2.5 nM phenol, 10 nM catechol and 5 nM p-cresol.  相似文献   

17.
An intelligent automated ammonia monitoring system was developed based on a commercial ammonia selective electrode used in flow injection analysis (FIA) mode. A prototype automatic monitoring system was produced and interfaced to an IBM personal computer. The interfacing involved the design and fabrication of a sensor interface, an inter-integrated circuit (I2C) card and a flow injection analysis controller. This ammonia monitoring system will be used in conjunction with the dissolved oxygen and temperature sensors for the determination of ammonia toxicity. Use of a sodium hydroxide reagent line allowed determination of total ammonia (un-ionized (NH3) + ionized (NH4+)). With the output of the pH and temperature probes, un-ionized ammonia can be determined based on an equilibrium calculation. This experimental system was controlled under an expert system, Crystal. It provides the knowledge of equipment setup, control and results interpretation based on the rules stored in its knowledge base.  相似文献   

18.
A biosensor for detection of formate at submicromolar concentrations has been developed by co-immobilizing formate dehydrogenase (FDH, E.C. 1.2.1.2), salicylate hydroxylase (SHL, E.C. 1.14.13.1) and NAD(+) linked to polyethylene glycol (PEG-NAD(+)) in a poly(vinyl alcohol) (PVA) matrix in front of a Clark-electrode. The principle of the bi-enzyme scheme is as follows: formate dehydrogenase converts formate into carbon dioxide using PEG-NAD(+). Corresponding PEG-NADH produced is then oxidized to PEG-NAD(+) by salicylate hydroxylase using sodium salicylate and oxygen. The oxygen consumption is monitored with the Clark-electrode. The advantages of this biosensor approach are the effective re-oxidation of PEG-NADH, and the entrapment of PEG-NAD(+) resulting in avoiding the addition of expensive cofactor to the working medium for each measurement. This bi-enzyme sensor has achieved a linear range of 1-300 microM and a detection limit of 1.98 x 10(-7) M for formate (S/N=3), with the response time of 4 min. The working stability is limited to 7 days due to the inactivation of the enzymes. Only sodium salicylate was needed in milli-molar amounts.  相似文献   

19.
A new amperometric, nanostructured sensor for the analytical determination of hydrogen peroxide is proposed. This sensor was constructed by immobilizing silver nanoparticles in a polyvinyl alcohol (PVA) film on a platinum electrode, which was performed by direct drop-casting silver nanoparticles that were capped in a PVA colloidal suspension. UV-vis spectroscopy, X-ray diffraction and transmission electron microscopy were used to give a complete characterization of the nanostructured film. Cyclic voltammetry experiments yielded evidence that silver nanoparticles facilitate hydrogen peroxide reduction, showing excellent catalytic activity. Moreover, the cronoamperometric response of modified sensors was dependent on nanoparticle lifetime. Experiments were performed, using freshly prepared solutions, after 4 and 8 days. Results concerning the quantitative analysis of hydrogen peroxide, in terms of detection limit, linear range, sensitivity and standard deviation (STD), are discussed for each tested sensor type. Utilization of two different linear ranges (40 microM to 6mM and 1.25 microM to 1.0mM) enabled the assessment of concentration intervals having up to three orders of magnitude. Moreover, the electrode made using a 4-day-old solution showed the maximal sensitivity of 128 nA microM(-1)(4090 nA microM(-1)cm(-2)), yielding a limit of detection of 1 microuM and STD of 2.5 microAmM(-1). All of these analytical parameters make the constructed sensors suitable for peroxide determination in aqueous solution.  相似文献   

20.
An immunosensor employing conducting polymer entrapment (CPE) method to immobilize immuno-protein on the quartz crystal microbalance (QCM) for clinical flow-injection-analysis (FIA) purpose was exploited. By comparing the CPE approach and the conventional physical immobilization (PI) method, a frequency shift of the former was 47% higher than that of the latter when measuring at 0.5 mg/ml human serum albumin antibody concentration. This implied that CPE was a feasible approach for developing QCM-FIA process. An immunoassay of anti-pseudorabies virus antibody in mouse sera further exemplified its practical potential in diagnostic implication.  相似文献   