首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
In this study, an extended calculation method for the determination of the water profiles in oil‐treated skin is proposed, which is based on the calculation of the ratio between the Raman band intensities of water (3350‐3550 cm?1) and keratin Amide I at 1650 cm?1. The proposed method is compared with the conventional method based on the ratio of the Raman band intensities of water (3350‐3550 cm?1) and keratin at 2930 cm?1. The conventional method creates artifacts in the depth profiles of the water concentration in oil‐treated skin, showing a lower amount of water in the upper and intermediate layers of the stratum corneum, which is due to the superposition of oil‐ and keratin‐related Raman bands at 2930 cm?1. The proposed extended method shows no artifacts and has the potential to determine the water depth profiles after topical application of formulations on the skin.  相似文献   

2.
Skin aging is a multifactorial phenomenon that involves alterations at the molecular, cellular and tissue levels. Our aim was to carry out a multiparametric biophysical and Raman characterization of skin barrier between individuals of different age groups (<24 and >70 years old). Our results showed a significant decrease of lipids to proteins ratio overall the thickness of the stratum corneum and higher lateral packing in the outer part of the SC for elderly. This can explain the decrease in trans epidermal water loss measured values rather than only SC thickening. Both age groups showed similar water content at SC surface while elderly presented higher water content in deep SC and viable epidermis. Mechanical measurements showed a decrease in the elasticity and an increase in the fatigability with age and were correlated with partially bound water. Highest correlation and anti-correlation values were observed for the deepest part of the SC and the viable epidermis.  相似文献   

3.
The epidermal protective functions are closely associated with skin hydration homeostasis. The understanding of different states of water binding is a rising concept in assessing topically applied formulations and their interaction within the stratum corneum (SC). In addition to global water content, primary bound water, partially bound water, and unbound water and barrier-related lipid lateral packing and protein secondary structure can be measured by Raman spectroscopy. This study aimed to establish an in vitro SC model to evaluate differences in the efficacy of a natural sugar-derived complex in combination with glycerol and a botanical extract in modulating SC water binding and structural proteins and barrier lipids. These compounds were selected due to their water-binding and soothing properties. The SC water profiles were assessed at the surface and in 8 μm SC depth. After a 12-hour hyperhydration and subsequent product incubation the measurements were performed during a 6 hours desiccation phase. The maximal water caption and the time until reaching a steady state are measured as well as water retention and resistance against water loss. Global water content, partially bound, and unbound water, as well as lipid and protein structures were assessed with confocal Raman microspectroscopy. Both the natural sugar-derived mixture and more pronounced, the same mixture with additional glycerol increased all three water-binding parameters at the surface and in 8 μm SC depth at the beginning and during the desiccation phase. Further addition of botanical extract did not result in an additional increase of the water-binding. All three formulations showed an increase in the lipid lateral packing values prevented the protein alteration as measured by β-sheets signal compared to blank. The present model is suited for screening studies comparing the specific effects of different compounds on hydration states. The natural sugar-derived mixture Aquaxyl showed evidence for an improvement of all SC hydration states, lipid and protein structure which was further enhanced by the addition of glycerol 5%. This improvement was evidenced at the surface and within the SC for all hydration-related parameters, and the lipid as well the protein structures. The addition of botanical extract phytoessence blue daisy did not show further improvement.  相似文献   

4.
A type of compact and cost‐effective light‐sheet imaging device, termed sub‐voxel‐resolving light‐sheet add‐on module (SLAM), is developed to cooperate with conventional 2D epifluorescence microscope, allowing high‐contrast, resolution‐improved 3D imaging of various biological samples at high throughput. Further details can be found in the article by Fang Zhao, Yicong Yang, Yi Li, et al. ( e201960243 ).

  相似文献   


5.
Short‐wave infrared hyperspectral imaging is applied to diagnose and monitor a case of allergic contact dermatitis (ACD) due to poison ivy exposure in one subject. This approach directly demonstrates increased tissue fluid content in ACD lesional skin with a spectral signature that matches the spectral signature of intradermally injected normal saline. The best contrast between the affected and unaffected skin is achieved through a selection of specific wavelengths at 1070, 1340 and 1605 nm and combining them in a pseudo‐red‐green‐blue color space. An image derived from these wavelengths normalized to unaffected skin defines a “tissue fluid index” that may aid in the quantitative diagnosis and monitoring of ACD. Further clinical testing of this promising approach towards disease detection and monitoring with tissue fluid content quantification is warranted.  相似文献   

6.
We show that polarization‐sensitive optical coherence tomography angiography (PS‐OCTA) based on full Jones matrix assessment of speckle decorrelation offers improved contrast and depth of vessel imaging over conventional OCTA. We determine how best to combine the individual Jones matrix elements and compare the resulting image quality to that of a conventional OCT scanner by co‐locating and imaging the same skin locations with closely matched scanning setups. Vessel projection images from finger and forearm skin demonstrate the benefits of Jones matrix‐based PS‐OCTA. Our study provides a promising starting point and a useful reference for future pre‐clinical and clinical applications of Jones matrix‐based PS‐OCTA.  相似文献   

7.
In recent years, the diagnosis of brain tumors has been investigated with attenuated total reflection‐Fourier transform infrared (ATR‐FTIR) spectroscopy on dried human serum samples to eliminate spectral interferences of the water component, with promising results. This research evaluates ATR‐FTIR on both liquid and air‐dried samples to investigate “digital drying” as an alternative approach for the analysis of spectra obtained from liquid samples. Digital drying approaches, consisting of water subtraction and least‐squares method, have demonstrated a greater random forest (RF) classification performance than the air‐dried spectra approach when discriminating cancer vs control samples, reaching sensitivity values higher than 93.0% and specificity values higher than 83.0%. Moreover, quantum cascade laser infrared (QCL‐IR) based spectroscopic imaging is utilized on liquid samples to assess the implications of a deep‐penetration light source on disease classification. The RF classification of QCL‐IR data has provided sensitivity and specificity amounting to 85.1% and 75.3% respectively.  相似文献   

8.
Our previous study on rat skin showed that cumulative oxidative pressure induces profound structural and ultrastructural alterations in both rat skin epidermis and dermis during aging. Here, we aimed to investigate the biophotonic properties of collagen as a main dermal component in the function of chronological aging. We used second harmonic generation (SHG) and two-photon excited fluorescence (TPEF) on 5 μm thick skin paraffin sections from 15-day-, 1-month- and 21-month-old rats, respectively, to analyze collagen alterations, in comparison to conventional light and electron microscopy methods. Obtained results show that polarization-resolved SHG (PSHG) images can detect collagen fiber alterations in line with chronological aging and that this method is consistent with light and electron microscopy. Moreover, the β coefficient calculated from PSHG images points out that delicate alterations lead to a more ordered structure of collagen molecules due to oxidative damage. The results of this study also open the possibility of successfully applying this fast and label-free method to previously fixed samples.  相似文献   

9.
The water and solute transporting properties of the epidermis have been proposed to be important determinants of skin moisture content and barrier properties. The water/small solute-transporting protein aquaporin-3 (AQP3) was found by immunofluorescence and immunogold electron microscopy to be expressed at the plasma membrane of epidermal keratinocytes in mouse skin. We studied the role of AQP3 in stratum corneum (SC) hydration by comparative measurements in wild-type and AQP3 null mice generated in a hairless SKH1 genetic background. The hairless AQP3 null mice had normal perinatal survival, growth, and serum chemistries but were polyuric because of defective urinary concentrating ability. AQP3 deletion resulted in a > 4-fold reduced osmotic water permeability and > 2-fold reduced glycerol permeability in epidermis. Epidermal, dermal, and SC thickness and morphology were not grossly affected by AQP3 deletion. Surface conductance measurements showed remarkably reduced SC water content in AQP3 null mice in the hairless genetic background (165 +/- 10 versus 269 +/- 12 microsiemens (microS), p < 0.001), as well as in a CD1 genetic background (209 +/- 21 versus 469 +/- 11 microS). Reduced SC hydration was seen from 3 days after birth. SC hydration in hairless wild-type and AQP3 null mice was reduced to comparable levels (90-100 microS) after a 24-h exposure to a dry atmosphere, but the difference was increased when surface evaporation was prevented by occlusion or exposure to a humidified atmosphere (179 +/- 13 versus 441 +/- 34 microS). Conductance measurements after serial tape stripping suggested reduced water content throughout the SC in AQP3 null mice. Water sorption-desorption experiments indicated reduced water holding capacity in the SC of AQP3 null mice. The impaired skin hydration in AQP3 null mice provides the first functional evidence for the involvement of AQP3 in skin physiology. Modulation of AQP3 expression or function may thus alter epidermal moisture content and water loss in skin diseases.  相似文献   

10.
In this study, a neurotoxicity model of zebrafish induced by amyloid beta (Aβ) protein was developed and evaluated in vivo by optical coherence tomography (OCT). Aβ protein and phosphate buffer saline (PBS) were separately injected into the head of two groups of adult zebrafish (n = 6 per group). Congo‐red staining results confirmed that Aβ protein had penetrated into brain tissue. All zebrafish were imaged with OCT on the 0th, 5th, 10th, 15th and 20th day postinjection. OCT images showed that PBS is not toxic to brain tissue. However, significant brain atrophy could be seen in the OCT images of zebrafish injected with Aβ‐protein that was verified by histological consequences. In addition, zebrafish in the model group showed memory decline in behavioral tests. This study verified the feasibility of in vivo long‐term assessment of Aβ protein‐induced brain atrophy in adult zebrafish by OCT that has great potential to be applied in the neurological diseases research.  相似文献   

11.
Y N Kalia  F Pirot    R H Guy 《Biophysical journal》1996,71(5):2692-2700
The objective of this study was to determine whether a structurally heterogeneous biomembrane, human stratum corneum (SC), behaved as a homogeneous barrier to water transport. The question is relevant because the principal function of the SC in vivo is to provide a barrier to the insensible loss of tissue water across the skin. Impedance spectra (IS) of the skin and measurements of the rate of transepidermal water loss (TEWL) were recorded sequentially in vivo in human subjects as layers of the SC were progressively removed by the serial application of adhesive tape strips. The low-frequency (< or = 100 rad s-1) impedance of skin was much more significantly affected by tape stripping than the higher frequency values; removal of the outermost SC layer had the largest effect. In contrast, TEWL changed little as the outer SC layers were stripped off, but increased dramatically when 6-8 microns of the tissue had been removed. It follows that the two noninvasive techniques probe SC barrier integrity in somewhat different ways. After SC removal, recovery of barrier function, as assessed by increasing values of the low-frequency impedance, apparently proceeded faster than TEWL decreased to the prestripping control. The variation of TEWL as a function of SC removal behaved in a manner entirely consistent with a homogeneous barrier, thereby permitting the apparent SC diffusivity of water to be found. Skin impedance (low frequency) was correlated with the relative concentration of water within the SC, thus providing an in vivo probe for skin hydration. Finally, the SC permeability coefficient to water, as a function of SC thickness, was calculated and correlated with the corresponding values of skin admittance derived from IS.  相似文献   

12.
Laser speckle contrast imaging (LSCI) is used in clinical research to dynamically image blood flow. One drawback is its susceptibility to movement artifacts. We demonstrate a new, simple method to correct motion artifacts in LSCI signals measured in awake mice with cranial windows during sensory stimulation. The principle is to identify a region in the image in which speckle contrast (SC) is independent of blood flow and only varies with animal movement, then to regress out this signal from the data. We show that (1) the regressed signal correlates well with mouse head movement, (2) the corrected signal correlates better with independently measured blood volume and (3) it has a (59 ± 6)% higher signal-to-noise ratio. Compared to three alternative correction methods, ours has the best performance. Regressing out flow-independent global variations in SC is a simple and accessible way to improve the quality of LSCI measurements.  相似文献   

13.
Water diffusion and the concentration profile within the skin significantly affect the surrounding chemical absorption and molecular synthesis. Occluding the skin causes water to accumulate in the top layer of the skin (the stratum corneum [SC]) and also affects the water diffusivity. Scar treatments such as silicone gel and silicone sheets make use of occlusion to increase skin hydration. However with existing techniques, it is not possible to quantitatively measure the diffusivity of the water during occlusion: current methods determine water diffusivity by measuring the water evaporated through the skin and thus require the skin to breathe. In this work, we use the high sensitivity of terahertz light to water to study how the water content in the SC changes upon occlusion. From our measurements, we can solve the diffusion equations in the SC to deduce the water concentration profile in occluded skin and subsequently to determine the diffusivity. To our knowledge, this is the first work showing how the diffusivity of human skin can be measured during occlusion and we envisage this paper as being used as a guide for non‐invasively determining the diffusivity of occluded human skin in vivo.   相似文献   

14.
Many skin diseases are defined by the presence of neutrophils, which are among the first cells to respond to infection and inflammation. Currently, neutrophil identification in the skin is costly and slow. The objectives of the present work are to investigate the feasibility of detecting the presence of neutrophils in live skin microsamples using chemiluminescence and develop a device and procedures that will enable preclinical and clinical investigations. Our approach consists of collecting skin microsamples and exposing them to reagents that activate neutrophils and amplify the light emission produced by chemiluminescence. Experiments using live pig skin with and without inflammation show that it is feasible to detect the presence of neutrophils in the skin. The proposed method is minimally invasive, simple, fast, and does not require user specialization. The developed system is compact in size with a small footprint, which makes it portable and suitable for point‐of‐care diagnostics.  相似文献   

15.
Skin water content monitoring is important for diagnostics and management of edema, dehydration, and other skin conditions as well as for cosmetic applications. Because optoacoustic (OA) technique has high (optical) contrast and (ultrasound) resolution and significant probing depth, it may be suitable for accurate, noninvasive water content monitoring in the skin. In this work we studied OA response from skin tissue phantoms and human wrist skin in the wavelength range from 1370 nm to 1650 nm using a novel, tunable OPO OA system. We identified optimal wavelengths for OA water content monitoring in different skin layers. The results of our study suggest that the OA technique may become a valuable, quantitative tool for accurate, high-resolution water content monitoring in the skin and other tissues and may find wide applications in dermatology, cosmetology, and tissue trauma management.  相似文献   

16.
The main components of the stratum corneum (SC), water, lipids, and proteins, are non-homogeneously distributed throughout the depth. The quantitative determination of their concentration profiles and penetration depth of topically applied substances are urgent topics of dermatological and cosmetic research. Confocal Raman micro-spectroscopy has distinct advantages when determining semi-quantitative concentrations of SC components and topically applied substances non-invasively and in vivo. In this work, we applied a tailored multivariate curve resolution-alternating least squares (tMCR-ALS) method to analyze Raman spectra of the SC in the 2000–4000 cm−1 region for quantitatively determining the concentrations of water, lipids, proteins, and topically applied oils using substance-related spectral loadings which were allowed to change depth-dependently from the SC's surface toward its bottom. tMCR-ALS makes matching of depth-dependent signal attenuation, that is, the normalization on keratin, unnecessary and requires only a few additional experiments for calibration – Raman spectra of the pure materials and their densities.  相似文献   

17.
This work addresses an unmet clinical need, that of glaucoma monitoring through intraocular pressure (IOP) interrogation in patients with artificial corneas (keratoprost hesis). We demonstrate direct integration of a low‐drift, fiber‐optic Fabry‐Perot pressure sensor embedded in the keratoprosthesis via rapid, non‐contact micromagnetic fiber alignment. IOP interrogation is achieved by using white‐light interferometry, which provides sub‐mmHg IOP sensitivity. Further details can be found in the article by Pui‐Chuen Hui, Katia Shtyrkova, Chengxin Zhou, et al. ( e202000031 ).

  相似文献   


18.
The object of this paper is in vivo study of skin spectral-characteristics in patients with kidney failure by conventional Raman spectroscopy in near infrared region. The experimental dataset was subjected to discriminant analysis with the projection on latent structures (PLS-DA). Application of Raman spectroscopy to investigate the forearm skin in 85 adult patients with kidney failure (90 spectra) and 40 healthy adult volunteers (80 spectra) has yielded the accuracy of 0.96, sensitivity of 0.94 and specificity of 0.99 in terms of identifying the target subjects with kidney failure. The autofluorescence analysis in the near infrared region identified the patients with kidney failure among healthy volunteers of the same age group with specificity, sensitivity, and accuracy of 0.91, 0.84, and 0.88, respectively. When classifying subjects by the presence of kidney failure using the PLS-DA method, the most informative Raman spectral bands are 1315 to 1330, 1450 to 1460, 1700 to 1800 cm−1. In general, the performed study demonstrates that for in vivo skin analysis, the conventional Raman spectroscopy can provide the basis for cost-effective and accurate detection of kidney failure and associated metabolic changes in the skin.  相似文献   

19.
Skin elasticity has been regarded as one of the main indicators of skin condition. Current measurement devices for skin elasticity are mostly expensive for home‐use and should contact the skin surface. As a first step to develop improved methods, we focus on the relation between skin elasticity and the entropy of skin images. Reduced skin elasticity causes wrinkles. It spreads frequency components and increases their randomness in the frequency domain. The randomness is quantified as entropy, which is a measure of the disorder of a system in physics. Therefore, skin elasticity is expected to have a negative relation with entropy. This tendency can be improved by applying penetration depth characteristics according to the wavelength of light. From cheeks and forehead of 12 Korean adults, skin images are acquired with three different light sources (470 nm, 870 nm and broadband light) and skin elasticity is measured. The root mean square error between the measured data and the fitted model is “0.27” (870 nm), “0.49” (broadband light) and “1.42” (470 nm). Furthermore, the results are analyzed by classifying by sex, age and measurement area. This study demonstrates the possibility of developing noncontact home‐use devices to measure skin elasticity in the future.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号