1.
We report a flexible light‐sheet fluorescence microscope (LSFM) designed for studying dynamic events in cardiac tissue at high speed in 3D and the correlation of these events to cell microstructure. The system employs two illumination‐detection modes: the first uses angle‐dithering of a Gaussian light sheet combined with remote refocusing of the detection plane for video‐rate volumetric imaging; the second combines digitally‐scanned light‐sheet illumination with an axially‐swept light‐sheet waist and stage‐scanned acquisition for improved axial resolution compared to the first mode. We present a characterisation of the spatial resolution of the system in both modes. The first illumination‐detection mode achieves dual spectral‐channel imaging at 25 volumes per second with 1024 × 200 × 50 voxel volumes and is demonstrated by time‐lapse imaging of calcium dynamics in a live cardiomyocyte. The second illumination‐detection mode is demonstrated through the acquisition of a higher spatial resolution structural map of the t‐tubule network in a fixed cardiomyocyte cell.  相似文献   

2.
Optical coherence tomography (OCT), with a high‐spatial resolution (<10 microns), intermediate penetration depth (~1.5 mm) and volumetric imaging capability is a great candidate to be used as a diagnostic‐assistant modality in dermatology. At this time, the accuracy of OCT for melanoma detection is lower than anticipated. In this letter, we studied for the first time, the use of a novel contrast agent consist of ultra‐small nanoparticles conjugated to a melanoma biomarker to improve the accuracy of OCT for differentiation of melanoma cells from nonmelanoma cells, in vitro. We call this approach SMall nanoparticle Aggregation‐enhanced Radiomics of Tumor (SMART)‐OCT imaging. This initial proof of concept study is the first step toward the broad utilization of this method for high accuracy all types of tumor detection applications.  相似文献   

3.
The present study examined the hypothesis that hypertonic saline dextran (HSD), given after an initial insult, attenuates exaggerated inflammation that occurs with a second insult. Adult rats (n = 15 per group) were divided into groups 1 (sham burn), 2 [40% total body surface area burn + 4 ml/kg isotonic saline (IS) + 4 ml.kg(-1).% burn(-1) lactated Ringer solution (LR)], and 3 (burn + 4 ml/kg HSD + LR), all studied 24 h after burns. Groups 4 (sham burn), 5 (burn + IS + LR), and 6 (burns + HSD + LR) received intratracheal (IT) vehicle 7 days after burns; groups 7 (burn + IS + LR) and 8 (burn + HSD + LR) received IT Streptococcus pneumoniae (4 x 10(6) colony-forming units) 7 days after burn. Groups 4-8 were studied 8 days after burn and 24 h after IT septic challenge. When compared with sham burn, contractile defects occurred 24 h after burn in IS-treated but not HSD-treated burns. Cardiac inflammatory responses (pg/ml TNF-alpha) were evident with IS (170 +/- 10) but not HSD (45 +/- 5) treatment vs. sham treatment (80 +/- 15). Pneumonia-related sepsis 8 days after IS-treated burns (group 7) exacerbated TNF-alpha responses/contractile dysfunction vs. IS-treated burns in the absence of sepsis (P < 0.05). Sepsis that occurred after HSD-treated burns (group 8) had less myocyte TNF-alpha secretion/better contractile function than IS-treated burns given septic challenge (group 7, P < 0.05). We conclude that an initial burn injury exacerbates myocardial inflammation/dysfunction occurring with a second insult; giving HSD after the initial insult attenuates myocardial inflammation/dysfunction associated with a second hit, suggesting that HSD reduces postinjury risk for infectious complications.  相似文献   

4.
Optical coherence tomography (OCT) angiography can noninvasively map microvascular networks and quantify blood flow in a cerebral cortex with a resolution of 1 to 10 μm and a penetration depth of 2 to 3 mm incorporating OCT signals and angiography algorithms. Different angiography algorithms have been developed in recent years; however, the performance of the algorithms has not been assessed quantitatively for neuroimaging applications. In this paper, we developed four metrics including vascular connectivity, contrast‐to‐noise ratio, signal‐to‐noise ratio and processing time to quantitatively assess the performance of OCT angiography algorithms in image quality and computation speed. After the imaging of a rat cortex using an OCT system, the cerebral microvascular networks were visualized by seven algorithms, and the performance of the algorithms was quantified and compared. Quantitative performance assessment of the algorithms can provide suggestions for the selection of appropriate OCT angiography algorithms in neuroimaging.  相似文献   

5.
We propose a cross‐scanning optical coherence tomography (CS‐OCT) system to correct eye motion artifacts in OCT angiography images. This system employs a dual‐illumination configuration with two orthogonally polarized beams, each of which simultaneously perform raster scanning in perpendicular direction with each other over the same area. In the reference arm, a polarization delay unit is used to acquire the two orthogonally polarized interferograms with a single photo detector by introducing different optical delay lines. The two cross‐scanned volume data are affected by the same eye motion but in two orthogonal directions. We developed a motion correction algorithm, which removes artifacts in the slow axis of each angiogram using the other and merges them through a nonrigid registration algorithm. In this manner, we obtained a motion‐corrected angiogram within a single volume scanning time without additional eye‐tracking devices.  相似文献   

6.
We present a pseudo‐real‐time retinal layer segmentation for high‐resolution Sensorless Adaptive Optics‐Optical Coherence Tomography (SAO‐OCT). Our pseudo‐real‐time segmentation method is based on Dijkstra's algorithm that uses the intensity of pixels and the vertical gradient of the image to find the minimum cost in a geometric graph formulation within a limited search region. It segments six retinal layer boundaries in an iterative process according to their order of prominence. The segmentation time is strongly correlated to the number of retinal layers to be segmented. Our program permits en face images to be extracted during data acquisition to guide the depth specific focus control and depth dependent aberration correction for high‐resolution SAO‐OCT systems. The average processing times for our entire pipeline for segmenting six layers in a retinal B‐scan of 496 × 400 and 240 × 400 pixels are around 25.60 and 13.76 ms, respectively. When reducing the number of layers segmented to only two layers, the time required for a 240 × 400 pixel image is 8.26 ms.  相似文献   

7.
The increase histopathological evaluation of prostatectomy specimens rises the workload on pathologists. Automated histopathology systems, preferably directly on unstained specimens, would accelerate the pathology workflow. In this study, we investigate the potential of quantitative analysis of optical coherence tomography (OCT) to separate benign from malignant prostate tissue automatically. Twenty fixated prostates were cut, from which 54 slices were scanned by OCT. Quantitative OCT metrics (attenuation coefficient, residue, goodness‐of‐fit) were compared for different tissue types, annotated on the histology slides. To avoid misclassification, the poor‐quality slides, and edges of annotations were excluded. Accurate registration of OCT data with histology was achieved in 31 slices. After removing outliers, 56% of the OCT data was compared with histopathology. The quantitative data could not separate malignant from benign tissue. Logistic regression resulted in malignant detection with a sensitivity of 0.80 and a specificity of 0.34. Quantitative OCT analysis should be improved before clinical use.  相似文献   

8.
Polarization‐resolved second‐harmonic generation (P‐SHG) microscopy is a technique capable of characterizing nonlinear optical properties of noncentrosymmetric biomaterials by extracting the nonlinear susceptibility tensor components ratio , with z‐axis parallel and x‐axis perpendicular to the C6 symmetry axis of molecular fiber, such as a myofibril or a collagen fiber. In this paper, we present two P‐SHG techniques based on incoming and outgoing circular polarization states for a fast extraction of : A dual‐shot configuration where the SHG circular anisotropy generated using incident right‐ and left‐handed circularly‐polarized light is measured; and a single‐shot configuration for which the SHG circular anisotropy is measured using only one incident circular polarization state. These techniques are used to extract the of myosin fibrils in the body wall muscles of Drosophila melanogaster larva. The results are in good agreement with values obtained from the double Stokes‐Mueller polarimetry. The dual‐ and single‐shot circular anisotropy measurements can be used for fast imaging that is independent of the in‐plane orientation of the sample. They can be used for imaging of contracting muscles, or for high throughput imaging of large sample areas.  相似文献   

9.
In the paper, we have developed an optical coherence hyperspectral microscopy with a single supercontinuum light source. The microscopy consists of optical coherence tomography (OCT) and hyperspectral imaging (HSI), which can visualize the structural and functional characteristics of biological tissues. The 500 to 700 nm band is selected for HSI and OCT imaging, where HSI enables imaging of oxygen saturation and hemoglobin (Hb) content, while OCT acquires structural characteristics to assess the morphology of biological tissues. The system performance of the optical coherence hyperspectral microscopy is verified by normal mice ears, and the practical applications of the microscopy is further performed in 4T1 and inflammation Balb/c mice ears in vivo. The experimental results demonstrate that the microscopy has potential to provide complementary information for clinical applications.  相似文献   

10.
Optical coherence tomography (OCT) is widely used for biomedical imaging and clinical diagnosis. However, speckle noise is a key factor affecting OCT image quality. Here, we developed a custom generative adversarial network (GAN) to denoise OCT images. A speckle‐modulating OCT (SM‐OCT) was built to generate low speckle images to be used as the ground truth. In total, 210 000 SM‐OCT images were used for training and validating the neural network model, which we call SM‐GAN. The performance of the SM‐GAN method was further demonstrated using online benchmark retinal images, 3D OCT images acquired from human fingers and OCT videos of a beating fruit fly heart. The denoise performance of the SM‐GAN model was compared to traditional OCT denoising methods and other state‐of‐the‐art deep learning based denoise networks. We conclude that the SM‐GAN model presented here can effectively reduce speckle noise in OCT images and videos while maintaining spatial and temporal resolutions.  相似文献   

11.
Objective: Our purpose was to characterize vegetation compositional patterns, tree regeneration, and plant diversity, and their relationships to landscape context, topography, and light availability across the margins of four stand‐replacing subalpine burns. Location: Four 1977 to 1978 burns east of the Continental Divide in Colorado: the Ouzel burn, a burn near Kenosha Pass, the Badger Mountain burn, and the Maes Creek burn. Methods: Vegetation and environmental factors were sampled in 200 0.01‐ha plots on transects crossing burn edges, and stratified by elevation. We utilized dissimilarity indices, mixed‐effects models, and randomization tests to assess relationships between vegetation and environment. Results: Three decades after wildfire, plant communities exhibited pronounced compositional shifts across burn edges. Tree regeneration decreased with increasing elevation and distance into burn interiors; concomitant increases in forbs and graminoids were linked to greater light availability. Richness was roughly doubled in high‐severity burn interiors due to the persistence of a suite of native species occurring primarily in this habitat. Richness rose with distance into burns, but declined with increasing elevation. Only three of 188 plant species were non‐native; these were widespread, naturalized species that comprised <1% total cover. Conclusions: These subalpine wildfires generated considerable, persistent increases in plant species richness at local and landscape scales, and a diversity of plant communities. The findings suggest that fire suppression in such systems must lead to reduced diversity. Concerns about post‐fire invasion by exotic plants appear unwarranted in high‐elevation wilderness settings.  相似文献   

12.
Evaluation of Lyophilised, Gamma-Irradiated Amnion as a Biological Dressing   总被引:3,自引:0,他引:3  
Burns, non-healing wounds and pressure sores cause extensive damage to the skin leading to infection and loss of precious body fluids. Despite advances in burn management the mortality rate continues to be high and the search for an economical and easily available dressing to control burn wound infection continues. Autologous skin has limited availability and is associated with additional scarring. Conventional dressings require frequent changes which can be painful and may even require anaesthesia.Amnion is an excellent biological dressing and its use in the treatment of burns has special appeal in India as there are religious barriers to the acceptance of bovine and porcine skin.Lyophilised, irradiated amnion provided for the first time in the country by the Tata Memorial Hospital Tissue Bank was evaluated as a temporary biological dressing. It was used to treat 35 patients with burns, 21 patients with bedsores and non-healing ulcers and the skin graft donor sites of 11 patients.The amnion was easy to handle and stuck well to the raw wound bed. An open dressing was used in most of the second degree burns which healed with hyperemia and early pigmentation. In patients with third degree burns, ulcers or skin graft donor sites, closed dressings were used. The exudate and induration were reduced and patients were more comfortable and experienced less pain. There was healthy granulation with good re-epithelialisation. Amnion was not used in patients with infected third degree burns.  相似文献   

13.
Incomplete surgical resection of head and neck squamous cell carcinoma (HNSCC) is the most common cause of local HNSCC recurrence. Currently, surgeons rely on preoperative imaging, direct visualization, palpation and frozen section to determine the extent of tissue resection. It has been demonstrated that optical coherence tomography (OCT), a minimally invasive, nonionizing near infrared mesoscopic imaging modality can resolve subsurface differences between normal and abnormal head and neck mucosa. Previous work has utilized two‐dimensional OCT imaging which is limited to the evaluation of small regions of interest generated frame by frame. OCT technology is capable of performing rapid volumetric imaging, but the capacity and expertise to analyze this massive amount of image data is lacking. In this study, we evaluate the ability of a retrained convolutional neural network to classify three‐dimensional OCT images of head and neck mucosa to differentiate normal and abnormal tissues with sensitivity and specificity of 100% and 70%, respectively. This method has the potential to serve as a real‐time analytic tool in the assessment of surgical margins.  相似文献   

14.
Effective intraoperative tumor margin assessment is needed to reduce re‐excision rates in breast‐conserving surgery (BCS). Mapping the attenuation coefficient in optical coherence tomography (OCT) throughout a sample to create an image (attenuation imaging) is one promising approach. For the first time, three‐dimensional OCT attenuation imaging of human breast tissue microarchitecture using a wide‐field (up to ~45 × 45 × 3.5 mm) imaging system is demonstrated. Representative results from three mastectomy and one BCS specimen (from 31 specimens) are presented with co‐registered postoperative histology. Attenuation imaging is shown to provide substantially improved contrast over OCT, delineating nuanced features within tumors (including necrosis and variations in tumor cell density and growth patterns) and benign features (such as sclerosing adenosis). Additionally, quantitative micro‐elastography (QME) images presented alongside OCT and attenuation images show that these techniques provide complementary contrast, suggesting that multimodal imaging could increase tissue identification accuracy and potentially improve tumor margin assessment.  相似文献   

15.
For purposes of comparison with the occlusive dressing method of treating burns, the exposure method was used in 30 cases—16 of first and second degree and 14 of third degree. Attempt was made to simulate the conditions which might be expected to prevail in mass treatment of burned patients—inadequate personnel and materials. Elaborate measures to immobilize burned areas were not employed.Healing of first and second degree burns was natural and the results satisfactory without further treatment. In third degree burns, skin grafting was necessary after the eschar was removed. Cracking of the eschar several days before time to remove it in some cases of third degree burns necessitated use of occlusive dressings in the last few days before skin grafting was done.The exposure method is considered valuable in circumstances in which saving of time, material and personnel is indicated. Generally it is not suitable for treatment of encircling burns of the trunk or extremities, since maintaining the integrity of the eschar is extremely difficult in such situations.  相似文献   

16.
The purpose of this study was to investigate the feasibility of using optical coherence tomography (OCT) to identify internal brain lesions, specifically intracerebral hemorrhage, without dissection. Mice with artificially injected brain hematomas were used to test the OCT system, and the recorded images were compared with microscopic images of the same mouse brains after hematoxylin and eosin staining. The intracranial structures surrounding the hematomas were clearly visualized by the OCT system without dissection. These images reflect the ability of OCT to determine the extent of a lesion in several planes. OCT is a useful technology, and these findings could be used as a starting point for future research in intraoperative imaging.  相似文献   

17.
In a recent clinical trial we evaluated the safety and immunogenicity of a recombinant OprF-OprI vaccine consisting of the mature outer membrane protein I (OprI) and amino acids 190-342 of OprF of Pseudomonas aeruginosa in burn patients and compared the elicited antibodies with antibodies against tetanus as response to a simultaneous immunization given on the day of admission. Safety and immunogenicity of the vaccine had been tested before in healthy human volunteers as published in 1999. In this first clinical trial we immunized eight burn patients suffering from second or third degree burns involving between 35% and 55% of the body surface three times with 100 microg of the OprF-OprI vaccine. The vaccine was found to be very well tolerated. The patients did not show any serious side effects - and in particular no activation of the mediator cascade was observed. None of the subjects showed systemic P. aeruginosa infections during or after the treatment of their burns. The serological tests (ELISA) for detection of antibodies against P. aeruginosa and tetanus toxoid showed seroconversion for seven patients after inoculation. The data indicate that OprF-OprI can be a useful vaccine in the therapeutic management of burn injuries.  相似文献   

18.
Top: Illustration of how to obtain 3D embryo images from a locust egg using OCT B‐scans. The internal structures of the embryo can be clearly identified as it develops. Bottom: The real time observation of katatrepsis and twist of a lowland locust embryo on days 7‐8, as the embryo develops. The embryonic movements can be readily identified by tracking the positions of the embryo's eyes (E1 and E2). Further details can be found in the article by Ya Su, Liya Wei, Hao Tan, et al. ( e201960047 ).

  相似文献   


19.
For spectral‐domain optical coherence tomography (SD‐OCT) studies of neurodegeneration, it is important to understand how segmentation algorithms differ in retinal layer thickness measurements, segmentation error locations and the impact of manual correction. Using macular SD‐OCT images of frontotemporal degeneration patients and controls, we compare the individual and aggregate retinal layer thickness measurements provided by two commonly used algorithms, the Iowa Reference Algorithm and Heidelberg Spectralis, with manual correction of significant segmentation errors. We demonstrate small differences of most retinal layer thickness measurements between these algorithms. Outer sectors of the Early Treatment Diabetic Retinopathy Study grid require a greater percent of eyes to be corrected than inner sectors of the retinal nerve fiber layer (RNFL). Manual corrections affect thickness measurements mildly, resulting in at most a 5% change in RNFL thickness. Our findings can inform researchers how to best use different segmentation algorithms when comparing retinal layer thicknesses.  相似文献   

20.
The purpose of this study was to evaluate early vascular and tomographic changes in the retina of diabetic patients using artificial intelligence (AI). The study included 74 age‐matched normal eyes, 171 diabetic eyes without retinopathy (DWR) eyes and 69 mild non‐proliferative diabetic retinopathy (NPDR) eyes. All patients underwent optical coherence tomography angiography (OCTA) imaging. Tomographic features (thickness and volume) were derived from the OCTA B‐scans. These features were used in AI models. Both OCT and OCTA features showed significant differences between the groups (P < .05). However, the OCTA features indicated early retinal changes in DWR eyes better than OCT (P < .05). In the AI model using both OCT and OCTA features simultaneously, the best area under the curve of 0.91 ± 0.02 was obtained (P < .05). Thus, the combined use of AI, OCT and OCTA significantly improved the early diagnosis of diabetic changes in the retina.  相似文献   