首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Visualizing biological processes in neuroscience requires in vivo functional imaging at single‐neuron resolution, high image acquisition speed and strong optical sectioning ability. However, due to light scattering of in tissue, very often conventional wide‐field fluorescence microscopes are unable to resolve cells in the presence of a strong out‐of‐focus background. Line‐scan focal modulation microscopy enables high temporal resolution and good optical sectioning ability at the same time. Here we demonstrate a quadrature demodulation method to extract the focal information with an extended frequency bandwidth and therefore higher spatial resolution. The performance of the demodulation scheme in line‐scan focal modulation microscope has been evaluated by performing imaging experiments with fluorescence beads and zebrafish neural structure. Reduced background, reduced artifacts and more detailed morphological information are evident in the obtained images.   相似文献   

2.
Current clinical brain imaging techniques used for surgical planning of tumor resection lack intraoperative and real‐time feedback; hence surgeons ultimately rely on subjective evaluation to identify tumor areas and margins. We report a fluorescence lifetime imaging (FLIm) instrument (excitation: 355 nm; emission spectral bands: 390/40 nm, 470/28 nm, 542/50 nm and 629/53 nm) that integrates with surgical microscopes to provide real‐time intraoperative augmentation of the surgical field of view with fluorescent derived parameters encoding diagnostic information. We show the functionality and safety features of this instrument during neurosurgical procedures in patients undergoing craniotomy for the resection of brain tumors and/or tissue with radiation damage. We demonstrate in three case studies the ability of this instrument to resolve distinct tissue types and pathology including cortex, white matter, tumor and radiation‐induced necrosis. In particular, two patients with effects of radiation‐induced necrosis exhibited longer fluorescence lifetimes and increased optical redox ratio on the necrotic tissue with respect to non‐affected cortex, and an oligodendroglioma resected from a third patient reported shorter fluorescence lifetime and a decrease in optical redox ratio than the surrounding white matter. These results encourage the use of FLIm as a label‐free and non‐invasive intraoperative tool for neurosurgical guidance.  相似文献   

3.
Having the least lenses, the significant feature of the singlet imaging system, helps the development of the portable and cost‐effective microscopes. A novel method of monochromatic/color singlet microscopy, which is combined with only one aspheric lens and deep learning computational imaging technology, is proposed in this article. The designed singlet aspheric lens is an approximate linear signal system, which means modulation‐transfer‐function curves on all field‐of‐views (5 mm diagonally) are almost coincident with each other. The purpose of the designed linear signal system is to further improve the resolution of our microscope by using deep learning algorithm. As a proof of concept, we designed a singlet microscopy based on our method, which weighs only 400 g. The experimental data and results of the sample USAF?1951 target and bio‐sample (the Equisetum‐arvense Strobile L.S), prove that the performance of the proposed singlet microscope is competitive to a commercial microscope with the 4X/NA0.1 objective lens. We believe that our idea and method would guide to design more cost‐effective and powerful singlet imaging system.  相似文献   

4.
Photoacoustic microscopy (PAM) provides a new method for the imaging of small‐animals with high‐contrast and deep‐penetration. However, the established PAM systems have suffered from a limited field‐of‐view or imaging speed, which are difficult to both monitor wide‐field activity of organ and record real‐time change of local tissue. Here, we reported a dual‐raster‐scanned photoacoustic microscope (DRS‐PAM) that integrates a two‐dimensional motorized translation stage for large field‐of‐view imaging and a two‐axis fast galvanometer scanner for real‐time imaging. The DRS‐PAM provides a flexible transition from wide‐field monitoring the vasculature of organs to real‐time imaging of local dynamics. To test the performance of DRS‐PAM, clear characterization of angiogenesis and functional detail was illustrated, hemodynamic activities of vasculature in cerebral cortex of a mouse were investigated. Furthermore, response of tumor to treatment were successfully monitored during treatment. The experimental results demonstrate the DRS‐PAM holds the great potential for biomedical research of basic biology.  相似文献   

5.
Light‐sheet fluorescence microscopy (LSFM) allows volumetric live imaging at high‐speed and with low photo‐toxicity. Various LSFM modalities are commercially available, but their size and cost limit their access by the research community. A new method, termed sub‐voxel‐resolving (SVR) light‐sheet add‐on microscopy (SLAM), is presented to enable fast, resolution‐enhanced light‐sheet fluorescence imaging from a conventional wide‐field microscope. This method contains two components: a miniature add‐on device to regular wide‐field microscopes, which contains a horizontal laser light‐sheet illumination path to confine fluorophore excitation at the vicinity of the focal plane for optical sectioning; an off‐axis scanning strategy and a SVR algorithm that utilizes sub‐voxel spatial shifts to reconstruct the image volume that results in a twofold increase in resolution. SLAM method has been applied to observe the muscle activity change of crawling C. elegans, the heartbeat of developing zebrafish embryo, and the neural anatomy of cleared mouse brains, at high spatiotemporal resolution. It provides an efficient and cost‐effective solution to convert the vast number of in‐service microscopes for fast 3D live imaging with voxel‐super‐resolved capability.  相似文献   

6.
Stimulated Raman Scattering (SRS) is a fast chemical imaging technique with remarkable bioscience applications. Cross Phase Modulation (XPM) is a ubiquitous nonlinear phenomenon that can create spurious background signals that render difficult a high-contrast imaging in SRS measurements. The XPM-induced signal is usually suppressed using high numerical aperture (NA) microscope objectives or condensers to collect the transmitted excitation beam. However, these high NA optics feature short working distances, hence they are not compatible with stage-top incubators, that are necessary to perform live-cell time-lapse experiments in controlled environments. Here, we show a 3D printed high NA compact catadioptric lens that fits inside stage-top incubators and allows the collection of XPM-free SRS signals. The lens delivers SRS images and spectra with a quality comparable to a signal collection with a high-NA microscope objective. We also demonstrate the compatibility of the 3D printed lens with other nonlinear microscopies usually associated with SRS in multimodal microscopes.  相似文献   

7.
A dual‐raster‐scanned photoacoustic microscope (DRS‐PAM) was reported, which integrates a two‐dimensional motorized translation stage for large field‐of‐view imaging and a two‐axis fast galvanometer scanner for real‐time imaging. The DRS‐PAM provides a flexible transition from wide‐field monitoring the vasculature of organs to real‐time imaging of local dynamics. Further details can be found in the article by Fei Yang, Zhiyang Wang, Wuyu Zhang, et al. ( e202000022 ).

  相似文献   


8.
Pathological crystal identification is routinely practiced in rheumatology for diagnosing arthritis disease such as gout, and relies on polarized light microscopy as the gold standard method used by medical professionals. Here, we present a single‐shot computational polarized light microscopy method that reconstructs the transmittance, retardance and slow‐axis orientation of a birefringent sample using a single image captured with a pixelated‐polarizer camera. This method is fast, simple‐to‐operate and compatible with all the existing standard microscopes without extensive or costly modifications. We demonstrated the success of our method by imaging three different types of crystals found in synovial fluid and reconstructed the birefringence information of these samples using a single image, without being affected by the orientation of individual crystals within the sample field‐of‐view. We believe this technique will provide improved sensitivity, specificity and speed, all at low cost, for clinical diagnosis of crystals found in synovial fluid and other bodily fluids.  相似文献   

9.
We report on wide‐field time‐correlated single photon counting (TCSPC)‐based fluorescence lifetime imaging microscopy (FLIM) with lightsheet illumination. A pulsed diode laser is used for excitation, and a crossed delay line anode image intensifier, effectively a single‐photon sensitive camera, is used to record the position and arrival time of the photons with picosecond time resolution, combining low illumination intensity of microwatts with wide‐field data collection. We pair this detector with the lightsheet illumination technique, and apply it to 3D FLIM imaging of dye gradients in human cancer cell spheroids, and C. elegans.  相似文献   

10.
Compression optical coherence elastography (OCE) typically requires a mechanical actuator to impart a controlled uniform strain to the sample. However, for handheld scanning, this adds complexity to the design of the probe and the actuator stroke limits the amount of strain that can be applied. In this work, we present a new volumetric imaging approach that utilizes bidirectional manual compression via the natural motion of the user's hand to induce strain to the sample, realizing compact, actuator‐free, handheld compression OCE. In this way, we are able to demonstrate rapid acquisition of three‐dimensional quantitative microelastography (QME) datasets of a tissue volume (6 × 6 × 1 mm3) in 3.4 seconds. We characterize the elasticity sensitivity of this freehand manual compression approach using a homogeneous silicone phantom and demonstrate comparable performance to a benchtop mounted, actuator‐based approach. In addition, we demonstrate handheld volumetric manual compression‐based QME on a tissue‐mimicking phantom with an embedded stiff inclusion and on freshly excised human breast specimens from both mastectomy and wide local excision (WLE) surgeries. Tissue results are coregistered with postoperative histology, verifying the capability of our approach to measure the elasticity of tissue and to distinguish stiff tumor from surrounding soft benign tissue.  相似文献   

11.
We present a pseudo‐real‐time retinal layer segmentation for high‐resolution Sensorless Adaptive Optics‐Optical Coherence Tomography (SAO‐OCT). Our pseudo‐real‐time segmentation method is based on Dijkstra's algorithm that uses the intensity of pixels and the vertical gradient of the image to find the minimum cost in a geometric graph formulation within a limited search region. It segments six retinal layer boundaries in an iterative process according to their order of prominence. The segmentation time is strongly correlated to the number of retinal layers to be segmented. Our program permits en face images to be extracted during data acquisition to guide the depth specific focus control and depth dependent aberration correction for high‐resolution SAO‐OCT systems. The average processing times for our entire pipeline for segmenting six layers in a retinal B‐scan of 496 × 400 and 240 × 400 pixels are around 25.60 and 13.76 ms, respectively. When reducing the number of layers segmented to only two layers, the time required for a 240 × 400 pixel image is 8.26 ms.  相似文献   

12.
Photoacoustic microscopy (PAM) can be classified as optical resolution (OR)‐PAM and acoustic resolution (AR)‐PAM depending on the type of resolution achieved. Using microelectromechanical systems (MEMS) scanner, high‐speed OR‐PAM system was developed earlier. Depth of imaging limits the use of OR‐PAM technology for many preclinical and clinical imaging applications. Here, we demonstrate the use of a high‐speed MEMS scanner for AR‐PAM imaging. Lateral resolution of 84 μm and an axial resolution of 27 μm with ~2.7 mm imaging depth was achieved using a 50 MHz transducer‐based AR‐PAM system. Use of a higher frequency transducer at 75 MHz has further improved the resolution characteristics of the system with a reduction in imaging depth and a lateral resolution of 53 μm and an axial resolution of 18 μm with ~1.8 mm imaging depth was achieved. Using the two‐axis MEMS scanner a 2 × 2 .5 mm2 area was imaged in 3 seconds. The capability of achieving acoustic resolution images using the MEMS scanner makes it beneficial for the development of high‐speed miniaturized systems for deeper tissue imaging.   相似文献   

13.
We report a flexible light‐sheet fluorescence microscope (LSFM) designed for studying dynamic events in cardiac tissue at high speed in 3D and the correlation of these events to cell microstructure. The system employs two illumination‐detection modes: the first uses angle‐dithering of a Gaussian light sheet combined with remote refocusing of the detection plane for video‐rate volumetric imaging; the second combines digitally‐scanned light‐sheet illumination with an axially‐swept light‐sheet waist and stage‐scanned acquisition for improved axial resolution compared to the first mode. We present a characterisation of the spatial resolution of the system in both modes. The first illumination‐detection mode achieves dual spectral‐channel imaging at 25 volumes per second with 1024 × 200 × 50 voxel volumes and is demonstrated by time‐lapse imaging of calcium dynamics in a live cardiomyocyte. The second illumination‐detection mode is demonstrated through the acquisition of a higher spatial resolution structural map of the t‐tubule network in a fixed cardiomyocyte cell.  相似文献   

14.
Moderate heating of collagenous tissues such as cartilage and cornea by infrared laser irradiation can produce biologically nondestructive structural rearrangements and relaxation of internal stresses resulting in the tissue reshaping. The reshaping results and eventual changes in optical and biological properties of the tissue strongly depend on the laser‐irradiation regime. Here, a speckle‐contrast technique based on monochromatic illumination of the tissue in combination with strain mapping by means of optical coherence elastography (OCE) is applied to reveal the interplay between the temperature and thermal stress fields producing tissue modifications. The speckle‐based technique ensured en face visualization of cross correlation and contrast of speckle images, with evolving proportions between contributions of temperature increase and thermal‐stresses determined by temperature gradients. The speckle‐technique findings are corroborated by quantitative OCE‐based depth‐resolved imaging of irradiation‐induced strain‐evolution. The revealed relationships can be used for real‐time control of the reshaping procedures (e.g., for laser shaping of cartilaginous implants in otolaryngology and maxillofacial surgery) and optimization of the laser‐irradiation regimes to ensure the desired reshaping using lower and biologically safer temperatures. The figure of waterfall OCE‐image demonstrates how the strain‐rate maximum arising in the heating‐beam center gradually splits and drifts towards the zones of maximal thermal stresses located at the temperature‐profile slopes.  相似文献   

15.
We demonstrate an accurate quantitative characterization of absolute two‐ and three‐photon absorption (2PA and 3PA) action cross sections of a genetically encodable fluorescent marker Sypher3s. Both 2PA and 3PA action cross sections of this marker are found to be remarkably high, enabling high‐brightness, cell‐specific two‐ and three‐photon fluorescence brain imaging. Brain imaging experiments on sliced samples of rat's cortical areas are presented to demonstrate these imaging modalities. The 2PA action cross section of Sypher3s is shown to be highly sensitive to the level of pH, enabling pH measurements via a ratiometric readout of the two‐photon fluorescence with two laser excitation wavelengths, thus paving the way toward fast optical pH sensing in deep‐tissue experiments.  相似文献   

16.
Current intraoperative imaging systems are typically not able to provide ‘sharp’ images over entire large areas or entire organs. Distinct structures such as tissue margins or groups of malignant cells are therefore often difficult to detect, especially under low signal‐to‐noise‐ratio conditions. In this report, we introduce a noise suppressed multifocus image fusion algorithm, that provides detailed reconstructions even when images are acquired under sub‐optimal conditions, such is the case for real time fluorescence intraoperative surgery. The algorithm makes use of the Anscombe transform combined with a multi‐level stationary wavelet transform with individual threshold‐based shrinkage. While the imaging system is integrated with a respiratory monitor triggering system, it can be easily adapted to any commercial imaging system. The developed algorithm is made available as a plugin for Osirix. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

17.
In this study, we introduce two key improvements that overcome limitations of existing polygon scanning microscopes while maintaining high spatial and temporal imaging resolution over large field of view (FOV). First, we proposed a simple and straightforward means to control the scanning angle of the polygon mirror to carry out photomanipulation without resorting to high speed optical modulators. Second, we devised a flexible data sampling method directly leading to higher image contrast by over 2‐fold and digital images with 100 megapixels (10 240 × 10 240) per frame at 0.25 Hz. This generates sub‐diffraction limited pixels (60 nm per pixels over the FOV of 512 μm) which increases the degrees of freedom to extract signals computationally. The unique combined optical and digital control recorded fine fluorescence recovery after localized photobleaching (r ~10 μm) within fluorescent giant unilamellar vesicles and micro‐vascular dynamics after laser‐induced injury during thrombus formation in vivo. These new improvements expand the quantitative biological‐imaging capacity of any polygon scanning microscope system.

  相似文献   


18.
Multispectral imaging combines the spectral resolution of spectroscopy with the spatial resolution of imaging and is therefore very useful for biomedical applications. Currently, histological diagnostics use mainly stainings with standard dyes (eg, hematoxylin + eosin) to identify tumors. This method is not applicable in vivo and provides low amounts of chemical information. Biomolecules absorb near infrared light (NIR, 800‐1700 nm) at different wavelengths, which could be used to fingerprint tissue. Here, we built a NIR multispectral absorption imaging setup to study skin tissue samples. NIR light (900‐1500 nm) was used for homogenous wide‐field transmission illumination and detected by a cooled InGaAs camera. In this setup, images I(x, y, λ) from dermatological samples (melanoma, nodular basal‐cell carcinoma, squamous‐cell carcinoma) were acquired to distinguish healthy from diseased tissue regions. In summary, we show the potential of multispectral NIR imaging for cancer diagnostics.   相似文献   

19.
We attempted to indicate the requirements for biomedical applications of SIMS microscopy. Sample preparation methodology should preserve both the structural and the chemical integrity of the tissue. Furthermore, it is often necessary to correlate ionic and light microscope images. This implies a common methodological approach to sample preparation for both microscopes. The use of low or high mass resolution depends on the elements studied and their concentrations. To improve the acquisition and processing of images, digital imaging systems have to be designed and require both ionic and optical image superimposition. However, the images do not accurately reflect element concentration; a relative quantitative approach is possible by measuring secondary ion beam intensity. Using an internal reference element (carbon) and standard curves the results are expressed in micrograms/mg of tissue. Despite their limited lateral resolution (0.5 microns) the actual SIMS microscopes are very suitable for the resolution of biomedical problems posed by action modes and drug localization in human pathology. SIMS microscopy should provide a new tool for metabolic radiotherapy by facilitating dose evaluation. The advent of high lateral resolution SIMS imaging (less than 0.1 microns) should open up new fields in biomedical investigation.  相似文献   

20.
Dynamic intravital imaging is essential for revealing ongoing biological phenomena within living organisms and is influenced primarily by several factors: motion artifacts, optical properties and spatial resolution. Conventional imaging quality within a volume, however, is degraded by involuntary movements and trades off between the imaged volume, imaging speed and quality. To balance such trade‐offs incurred by two‐photon excitation microscopy during intravital imaging, we developed a unique combination of interlaced scanning and a simple image restoration algorithm based on biological signal sparsity and a graph Laplacian matrix. This method increases the scanning speed by a factor of four for a field size of 212 μm × 106 μm × 130 μm, and significantly improves the quality of four‐dimensional dynamic volumetric data by preventing irregular artifacts due to the movement observed with conventional methods. Our data suggest this method is robust enough to be applied to multiple types of soft tissue.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号