首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this article, one of the potential degradation products of the novel antiviral drug simeprevir was isolated and characterized by means of infrared (IR) and mass spectrometry. Moreover, comparative molecular docking, ADMET (absorption, distribution, metabolism, excretion – toxicity) and insilico toxicity prediction studies were applied to evaluate the activity of simeprevir and its degradation product. Furthermore,a simple, accurate and selective second derivative synchronous spectrofluorimetric method was developed for the determination of simeprevir in the presence of its oxidative degradation product.The synchronous fluorescence spectra of both compounds were measured in ethanol at pH 2.0 usingΔλ of 140 nm and the peak amplitude of the second derivative spectra were measured at 442 nm. The method was rectilinear over the concentration range of 0.2 to 2.0 μg/ml and validated according to the ICH (International Conference on Harmonization) guidelines. Moreover, the method was statistically compared to the reverse‐phase high‐performance liquid chromatography (RP‐HPLC) method and good results were obtained.  相似文献   

2.
A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of gemifloxacin mesylate (GFX) in tablets. The method is based on measuring the native fluorescence of GFX in isopropanol at 400 nm after excitation at 272 nm. The fluorescence–concentration plot was rectilinear over the range of 0.01–0.50 µg/mL with a lower detection limit of 1.19 ng/mL and quantification limit of 3.6 ng/mL. The method was fully validated and successfully applied to the determination of GFX tablets with an average percentage recovery of 99.65 ± 0.532. The method was extended to the stability study of GFX. The drug was exposed to acidic, alkaline, oxidative and photolytic degradation according to International Conference on Harmonization guidelines. The rate of GFX degradation was found at its highest in acidic conditions, and in its lowest in the neutral one. However, it was stable under dry heat and photolytic degradation conditions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Milnacipran is an antidepressant drug belonging to the class of serotonin and noradrenaline reuptake inhibitors. A sensitive high performance liquid chromatographic during the development method coupled with a fluorimetric detection was set up, validated and then used routinely of the drug. After liquid-liquid extraction, milnacipran and its internal standard were analyzed by reversed-phase liquid chromatography (LC). The drug was derivatized with fluorescamine for fluorescence detection. The identity of the liquid chromatography peaks was controlled using mass spectrometry. The assay linearity was validated up to 1000 ng/ml. The limit of quantification was set at 5 ng/ml. Precision values (relative standard deviations) were lower than 5.4%, whereas the mean accuracy was higher than 95%. The extraction recoveries were higher than 70% for both milnacipran and the internal standard. In clinics, the LC-fluorescence method was routinely used to investigate the pharmacokinetics of milnacipran in patients and proved to be robust and capable of quantifying milnacipran in plasma for at least 36 h (four- to five-fold the elimination half-life).  相似文献   

4.
A new, simple and sensitive spectrofluorimetric method has been developed for the determination of aliskiren (ALS) in dosage forms and human urine. The method is based on the reaction between ALS and fluorescamine in borate buffer solution, pH 9, to give a highly fluorescent derivative which is measured at 482 nm after excitation at 382 nm. The factors affecting the reaction were carefully studied. The fluorescence intensity concentration plots were rectilinear over the range 140–1400 ng/mL with a limit of detection 13.47 ng/mL and limit of quantitation 40.81 ng/mL. The developed method was successfully applied to the analysis of the drug in tablets and human urine; the average recoveries (n = 6) were 99.88 ± 0.38% and 99.57 ± 0.44%, respectively. The analytical performance of the method was fully validated and the results were satisfactory. The stability of the drug was studied by subjecting it to acidic, basic, oxidative and thermal degradation. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Orciprenaline sulphate (ORP) is a direct‐acting sympathomimetic with mainly beta‐adrenoceptor stimulant activity. It is used as a bronchodilator in the management of reversible airway obstruction. For the first time, a rapid highly sensitive spectrofluorimetric method is described that is relied on measuring the fluorescence spectra of ORP at acidic pH and without addition of any chemical reagents. The relative fluorescence intensity was measured at 310 nm and after excitation at 224 nm. ORP native fluorescence was calibrated in both water and acetonitrile as diluting solvents. The method was designed to estimate the drug in miscellaneous matrices with high accuracy and precision. Linear ranges of calibration curves were 30.0–400.0 ng/ml and 10.0–240.0 ng/ml in water and acetonitrile, respectively. The detection limits were calculated and reached as low as 3.3 and 3.1 ng/ml, respectively, representing the ultra‐sensitivity of the proposed method. This result permitted application of this method for spiked human plasma and urine and was used as a preliminary investigation with good percentage recovery (89.4–106.8%). The application was further extended to analyse ORP in its pharmaceutical formulations. The method was validated in compliance with International Council of Harmonization (ICH) Guidelines.  相似文献   

6.
A new simple stability‐indicating spectrofluorimetric method has been developed and validated for the determination of the tyrosine kinase inhibitor, linifanib (LNF). The proposed method makes use of the native fluorescence characteristics of LNF in a micellar system. Compared with aqueous solutions, the fluorescence intensity of LNF was greatly enhanced upon the addition of Tween‐80. The relative fluorescence intensity of LNF was measured in a diluting solvent composed of 2% Tween‐80: phosphate buffer pH 8.0 (20: 80, v/v) using excitation and emission wavelengths of 290 and 450 nm, respectively. The proposed method was fully validated as per the ICH guidelines. The recorded fluorescence intensity of LNF was rectilinear over a concentration range of 0.3–2 μg/ml with a high correlation coefficient (r = 0.9990) and low limits of detection (0.091 μg/ml) and quantitation (0.275 μg/ml). The applicability of the method was extended to study the inherent stability of LNF under different stress degradation conditions including, alkaline, acidic, oxidative, photolytic and thermal degradation. Moreover, the method was utilized to study the kinetics of the alkaline and oxidative degradation of LNF. The pseudo‐first order rate constants and half‐lives were calculated.  相似文献   

7.
A novel, quick, simple and highly sensitive spectrofluorimetric method was developed and validated for the determination of sitagliptin (SG) in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of sitagliptin in an SDS micellar system. In an aqueous solution of phosphate buffer pH 4.0, the fluorescence intensity of SG in the presence of SDS was greatly enhanced, by 200%, i.e. twofold enhancement. The fluorescence intensity of SG was measured at 300 nm after excitation at 270 nm. The method showed good linearity in the range 0.03–10.0 µg/mL with a good correlation coefficient (r = 0.9998). The limits of detection and quantitation values were 5.31 and 16.1 ng/mL, respectively. The proposed method was successfully applied to the analysis of SG in its single and co‐formulated commercial tablets; the results were in good agreement with those obtained using a reference method. Application of the proposed method was extended to stability studies of SG after exposure to different forced degradation conditions according to the ICH guidelines, such as acidic, alkaline, thermal, photo‐ and oxidative stress. The chemical structure of certain potential degradation products (DPs) were investigated using LC‐MS. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 microg/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992.  相似文献   

9.
GS4071 is a potent inhibitor of influenza neuraminidase. A precolumn fluorescence derivatization HPLC method is described for the analysis of GS4071 in rat plasma. Plasma samples were subjected to solid-phase extraction on C18 extraction columns. After extraction, GS4071 was derivatized with naphthalenedialdehyde in the presence of potassium cyanide to produce highly fluorescent cyano[f]benzoisoindole derivatives. Derivatized samples were stable for >24 h at 4°C. The samples were analyzed by an isocratic HPLC method using fluorescence detection at 420 nm excitation and 470 nm emission wavelength. The method was validated and applied to the analysis of plasma samples from pre-clinical pharmacokinetic studies in rats. The limit of detection for GS4071 was 20 ng/ml. For five replicate samples at 50, 400, and 1000 ng/ml, the within-day precision values were 16.9, 9.4 and 4.5%, respectively, and the between-day precision values were 16.9, 7.9, and 2.1%, respectively. The method was linear from 25 to 1600 ng/ml and the total recovery was >68% over this concentration range.  相似文献   

10.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA.  相似文献   

11.
There is considerable interest in quantifying morphine and its major metabolites, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). Available assays use gas chromatography-mass spectrometry or high-performance liquid chromatography (HPLC) with single or tandem mass spectrometry, ultraviolet, electrochemical, or fluorimetric detection. Nevertheless, few methods provide adequate sensitivity for all analytes, in a single injection, with the desired rate of sample throughput. A rapid and sensitive method for quantification of morphine, M3G and M6G from human plasma using HPLC with electrospray ionization mass spectrometry was developed using a Waters Oasis MCX 96-well plate for extracting both lipophilic morphine and its hydrophilic glucuronides, C18 separation using an isocratic mobile phase (methanol, acetonitrile and formic acid), and selected ion monitoring. Recoveries of morphine, M3G and M6G, respectively, were 81, 90 and 82% at the low (2, 25 and 2 ng/ml), 80, 77 and 75% at the medium (10, 250 and 10 ng/ml), and 74, 62 and 72% at the high (100, 1000 and 100 ng/ml) quality control samples. The limit of quantitation was 0.5 ng/ml morphine and M6G, and 5 ng/ml M3G. Analytes were validated over a linear range of 0.5-200 ng/ml morphine and M6G, and 5-2000 ng/ml M3G. This assay represents an improvement over existing methods through solid phase extraction with increased sample throughput (96-well plates), use of small samples (0.5 ml), and sub-nanogram detection.  相似文献   

12.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of celecoxib in human plasma. The analysis was carried out on a monolithic silica column using UV detection at 254 nm. The assay enables the measurement of celecoxib for therapeutic drug monitoring with a minimum quantification limit of 10 ng ml(-1). The method involves simple, one-step extraction procedure, and analytical recovery was 100.5 +/- 1.3%. The calibration curve was linear over the concentration range of 10-800 ng ml(-1). The coefficients of variation for inter-day and intra-day assay were found to be less than 8%. We also demonstrate the applicability of this method for pharmacokinetic studies in humans.  相似文献   

13.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

14.
We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sutopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sutopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9–7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6±30.8, 321.1±93.7, 726.5±143.1 and 1273.6±211.2 ng/ml, respectively.  相似文献   

15.
Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast-one run could be performed within less than 10 min (CE-UV method) and 2.5 min (CE-LIF method), respectively. Both assays were fully validated and applied to urine samples from a human volunteer. The results of the application of the CE-LIF method to human urine samples are presented in this publication.  相似文献   

16.
A sensitive and selective bioanalytical liquid chromatographic method for diclofenac is described. The drug was detected as a fluorescent derivative, which was demonstrated by 1H NMR and mass spectrometric studies to be carbazole acetic acid. Diclofenac was derivatized by UV irradiation of the substance performed as a post-column photoreaction. The reactor was a PTFE capillary wound around a 254-nm UV lamp. Diclofenac was isolated from the plasma samples by precipitation of the proteins with acetonitrile. A 50-μl volume of the supernatant was injected onto a Nucleosil C18 column. The mobile phase was 32% acetonitrile in pH 6.6 buffer. Carbazole acetic acid was detected by a fluorescence detector using an excitation wavelength of 288 nm and an emission wavelength of 360 nm. The recovery was 92%, the standard curve was linear in the range 10–5500 ng diclofenac per ml plasma, and the relative standard deviation at 10 and 5000 ng of diclofenac per ml plasma was 9.0% and 3.3%, respectively. The limit of detection was 6 ng/ml at an injection volume of 50 μl. Chromatograms of human and rat plasma containing diclofenac are shown.  相似文献   

17.
A simple, rapid, sensitive, and specific liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the quantification of amitraz and its metabolite in human serum. Both the compounds were extracted using monolithic silica spin columns with acetonitrile. The chromatographic separation was performed on a reverse-phase C(18) column with a mobile phase of 10 mM ammonium formate-acetonitrile. The protonated analyte was quantitated in positive ionization by mass spectrometry. The method was validated over the concentration range of 25-1000 ng/ml for amitraz and its metabolite in human serum. For both compounds, the limit of detection was 5 ng/ml. The method was applied to serum samples taken from an attempted suicide patient, and only small volumes of serum were required for the simultaneous determination of these compounds.  相似文献   

18.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in plasma was developed. An Applied Biosystems API 3000 triple quadrupole mass spectrometer set to multiple reaction monitoring (MRM) mode, using atmospheric pressure photospray ionisation (APPI) in the positive mode. Using 17-alpha-methyltestosterone as internal standard (IS), liquid-liquid extraction was followed by reversed phase liquid chromatography using a phenyl-hexyl column and tandem mass spectrometric detection. The mean recovery for levonorgestrel and 17-alpha-methyltestosterone was 99.5 and 62.9%, respectively. The method was validated from 0.265 to 130 ng levonorgestrel/ml plasma with the lower limit of quantification (LLOQ) set at 0.265 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric (MS/MS) detection, allowing for a rapid (extraction and chromatography) and selective method for the determination of levonorgestrel in human plasma. The assay method was used in a pharmacokinetic study to quantify levonorgestrel in human plasma samples generated after administrating a single oral dose of 1.5 mg levonorgestrel to healthy female volunteers for up to five half lives. The total chromatographic runtime of this method was 5.0 min per sample, allowing for analysis of a large number of samples per batch.  相似文献   

19.
The prokinetic drug, prucalopride (PCP) succinate, was determined using a new spectrofluorimetric approach with a highly sensitive, rapid, and simple procedure. The method exploited the enhancement of the inherent native fluorescence of PCP by micellar aggregation with sodium lauryl sulfate (SLS) as an anionic surfactant. Different factors that could affect the fluorescence intensity were carefully studied in order to achieve the maximal fluorescence signal. Measurement of the enhanced fluorescence was done at 354 nm after the excitation at 276 nm. The fluorescence intensity–concentration plot was rectilinear in the concentration range of 50–600 ng/ml with detection and quantitation limits of 13.9 and 42.1 ng/ml, respectively. The method underwent validation according to the International Council for Harmonisation criteria in order to assess its analytical performance, and promising results were achieved that proved the validity and reliability of the method. Furthermore, the method was employed effectively for the analysis of the cited drug in commercial pharmaceutical tablets.  相似文献   

20.
Meloxicam was quantified in human plasma after a single 15 mg oral dose of the drug was given to 26 healthy volunteers. An Applied Biosystems Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray (TIS) in the positive ion mode, was used. Protein precipitation with acetonitrile was followed by C(18) reverse phase liquid chromatography and tandem mass spectrometry. The mean recovery for meloxicam was 92% with a lower limit of quantification of 8.96 ng/ml. Piroxicam was used as the internal standard. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometry (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of meloxicam in human plasma than has previously been described.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号