首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and selective spectrofluorimetric method for the detection of chlortetracycline (CTC) was studied. In pH 7.4 buffer medium l ‐tryptophan (l ‐Trp), applied as the fluorescence probe, interacted with CTC resulting in fluorescence quenching of the probe. CTC was detected with maximum excitation and emission wavelengths at λex/λem = 275/350 nm. Notably, quenching of fluorescence intensities was positively proportional to the CTC concentration over the range of 0.65–30 μmol L?1 and the limit of detection was 0.2 μmol L?1. Effect of temperature shown in Stern?Volmer plots, absorption spectra and fluorescence lifetime determination, indicated that fluorescence quenching of l ‐Trp by CTC was mainly by static quenching. The proposed study used practical samples analysis satisfactorily.  相似文献   

2.
A new method for the determination of selenium based on its fluorescence quenching on the hemoglobin‐catalyzed reaction of H2O2 and l ‐tyrosine has been established. The effect of pH, foreign ions and the optimization of variables on the determination of selenium was examined. The calibration curve was found to be linear between the fluorescence quenching (F0/F) and the concentration of selenium within the range of 0.16‐4.00 µg/mL. The detection limit was 1.96 ng/mL and the relative standard deviation was 3.14%. This method can be used for the determination of selenium in Se‐enriched garlic bulbs with satisfactory results. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
We have established a real‐time and label‐free fluorescence turn‐on strategy for protease activity detection and inhibitor screening via peptide‐induced aggregation‐caused quenching of a perylene probe. Because of electrostatic interactions and high hydrophilicity, poly‐l ‐glutamic acid sodium salt (PGA; a negatively charged peptide) could induce aggregation of a positively charged perylene probe (probe 1) and the monomer fluorescence of probe 1 was effectively quenched. After a protease was added, PGA was enzymatically hydrolyzed into small fragments and probe 1 disaggregated. The fluorescence recovery of probe 1 was found to be proportional to the concentration of protease in the range from 0 to 1 mU/ml. The detection limit was down to 0.1 mU/ml. In the presence of a protease inhibitor, protease activity was inhibited and fluorescence recovery reduced. Moreover, we demonstrated the potential application of our method in a complex mixture sample including 1% human serum. Our method is simple, fast and cost effective.  相似文献   

4.
In Britton‐Robinson (BR) buffer medium (pH 3.3), carbazochrome sodium sulfonate (CSS) can react with some aromatic amino acids such as tryptophan (Trp), tyrosine (Tyr) and phenylalanine (Phe) to form a 1:1 complex by electrostatic attraction, aromatic stacking interaction and Van der Waals' force, resulting in fluorescence quenching of these amino acids. Maximum quenching wavelengths were located at 352 nm (CSS‐Trp system), 303 nm (CSS‐Tyr system) and 284 nm (CSS‐Phe system), respectively. The fluorescence quenching value (ΔF) was proportional to the concentration of CSS in a certain range. The fluorescence quenching method for the determination of CSS showed high sensitivity, with detection limits of 31.3 ng/mL (CSS‐Trp system), 44.6 ng/mL (CSS‐Tyr system) and 315.0 ng/mL (CSS‐Phe system), respectively. The optimum conditions of the reaction conditions and the effect of coexisting substances were investigated and results showed that the method had good selectivity. The method was successfully applied for the rapid determination of CSS in blood and urine samples. Based on the bimolecular quenching constant Kq, the effect of temperature and Stern‐Volmer plots, this study showed that quenching of fluorescence of amino acids by CSS was a static quenching process. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of lacidipine (LCP) in tablets. The proposed method is based on the investigation of the fluorescence spectral behavior of LCP in both sodium dodecyl sulphate (SDS) and the tween‐80 micellar system. In aqueous solutions of acetate buffer (pH 4.5), the fluorescence intensities of LCP were greatly enhanced (ca. 2.4 and 4.3 folds) in the presence of either SDS or tween‐80, respectively. The fluorescence intensity was measured at 444 nm after excitation at 277 nm using either SDS or tween‐80 as a surfactant. The fluorescence–concentration plots were rectilinear over the ranges of 50.0–500.0 ng/ml and 5.0–200.0 ng/ml with lower detection limits of 5.11 and 2.06 ng/ml and lower quantification limits of 17 and 6.87 ng/ml using SDS and tween‐80, respectively. The method was successfully applied to the analysis of LCP in commercial tablets and the results were in good agreement with those obtained with the comparison method. Furthermore, content uniformity testing of pharmaceutical tablets was also conducted. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Three spectrofluorimetric methods were developed for agomelatine (AGM) determination in commercial tablets. Method A is based on measuring the native fluorescence of AGM aqueous solution at 230/360 nm. Methods B and C are based on the formation of a charge transfer complex between AGM and 2,3‐dichloro‐5,6‐dicyano‐1,4‐benzoquinone (DDQ) and 7,7,8,8‐tetracyanoquinodimethane (TCNQ) with measurement of the formed fluorophore at 365/475 nm and 250/304 nm, respectively. The relative fluorescence intensity (RFI) of AGM–DDQ complex was greatly enhanced in the presence of methyl‐β‐cyclodextrin (CD). The methods were linear over the concentration ranges of 0.015–0.5, 0.5–8.0, 0.09–6.0 and 0.05–0.2 μg/ml for AGM‐native fluorescence, AGM–DDQ, AGM–DDQ–CD and AGM–TCNQ complexes, respectively with excellent correlation coefficients (r = 0.9999). The methods were validated as per the International Conference on Harmonization (ICH) guidelines and all validation requirements were satisfied. The developed methods were extended to the analysis of AGM in commercial tablets. Furthermore, the stability of AGM was studied under different stress conditions (alkaline, acidic, oxidative and photolytic). The potential alkaline and acidic degradation products were identified by LC–MS/TOF.  相似文献   

7.
A rapid, novel and cost-effective spectrofluorimetric method developed to determine moxifloxacin (MFX) in pharmaceutical preparations because MFX in a pH 10 medium could reduce the fluorescence intensity of l -tryptophan. The maximum fluorescence excitation and emission wavelengths were found to be 280 and 363 nm respectively. A range of factors affecting fluorescence quenching and the effect of co-existing substances were investigated. Fluorescence quenching values (ΔF = FL-tryptophanFMoxi-L-tryptophan) displayed a strong linear relationship with the MFX concentration ranging from 0.2 to 8.0 μg/ml under optimum conditions. The limit of detection was found to be 6.1 × 10−4 μg/ml. The proposed method was shown to be suitable for MFX determination in pharmaceutical tablets and biological fluids by the linearity, recovery and limit of detection. The spectrofluorimetric approach that has been developed is extremely eco-friendly, as evidenced by the fact that all the experimental components and solvents were safe for the environment.  相似文献   

8.
Highly sensitive, rapid, accurate and precise synchronous fluorescence spectrofluorimetric method has been developed for simultaneous analysis of a mixture of amlodipine (AMD) and metoprolol (MET). The method relies on measuring the relative synchronous fluorescence intensity of both drugs at Δλ of 90 nm in acetate buffer solution at pH 5. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.2–2 μg/ml and 0.5–10 μg/ml for AMD and MET, respectively. The limits of detection were 50 ng/ml for AMD and 130 ng/ml for MET while the limits of quantitation were 150 ng/ml for AMD and 390 ng/ml for MET. The developed method was applied successfully for the determination of the two drugs in their co‐formulated tablet. The mean percent recoveries were found to be 100.51 and 99.57 for AMD and MET, respectively.  相似文献   

9.
Losartan potassium (LOS) and atorvastatin (ATR) are used in combination for long‐term treatment of stroke and for treatment of hypertension with high‐level cholesterol. Both drugs were simultaneously determined and validated using a novel, easy, fast, and economical first‐derivative synchronous fluorescence spectroscopic method. Methanol was used as the solvent for both drugs at a Δλ 80 nm and with a scanning rate of 600 nm/min. Peaks were determined as at 288.1 nm and 263.6 nm for LOS and ATR, respectively. The proposed method was validated according to International Conference on Harmonization guidelines and, subsequently, the developed method was applicable to the analysis of the two compounds in their different formulations without interference from each other. Amplitude–concentration plots were rectilinear over the concentration ranges 1.0–10.0 μg/ml and 0.5–5.0 μg/ml for LOS and ATR, respectively. Detection limits were found to be 0.096 μg/ml and 0.030 μg/ml and quantitation limits were 0.291 μg/ml and 0.093 μg/ml for LOS and ATR, respectively. The proposed method was successfully applied to the analysis of both compounds in synthetic mixtures and in laboratory‐prepared tablets. These results were in accordance with the results acquired using the comparison method, high‐performance liquid chromatography.  相似文献   

10.
Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for the estimation of two anti-migraine drugs, namely sumatriptan succinate (SUM) and zolmitriptan (ZOL). These methods depend on producing a yellow-coloured product after the reaction of the two drugs with 7-chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). The reaction products exhibited maximum absorbance at 481 nm in borate buffer of pH 9 and fluorescence emission peak at 540 nm after excitation at 470 nm for the two drugs. The linear ranges were 5–60 μg/ml for SUM and 5–50 μg/ml for ZOL in the spectrophotometric method (Method I), whereas this was 0.4–4 μg/ml for SUM and 0.5–5 μg/ml for ZOL in the spectrofluorimetric method (Method II). The method validity was assessed according to International Council for Harmonisation (ICH) guidelines. Statistical analysis of the results obtained from the proposed and comparison methods confirmed that the proposed methods were highly accurate and precise. The suggested methods could be used for the determination of the mentioned drugs in both pure form and in tablets.  相似文献   

11.
Water‐soluble glutathione (GSH)‐capped core/shell CdTe/CdS quantum dots (QDs) were synthesized. In pH 5.4 sodium phosphate buffer medium, the interaction between GSH‐CdTe/CdS QDs and sanguinarine (SA) was investigated by spectroscopic methods, including fluorescence spectroscopy and ultraviolet‐visible absorption spectroscopy. Addition of SA to GSH‐CdTe/CdS QDs results in fluorescence quenching of GSH‐CdTe/CdS QDs. Quenching intensity was in proportion to the concentration of SA in a certain range. Investigation of the quenching mechanism, proved that the fluorescence quenching of GSH‐CdTe/CdS QDs by SA is a result of electron transfer. Based on the quenching of the fluorescence of GSH‐CdTe/CdS QDs by SA, a novel, simple, rapid and specific method for SA determination was proposed. The detection limit for SA was 3.4 ng/mL and the quantitative determination range was 0.2–40.0 µg/mL with a correlation coefficient of 0.9988. The method has been applied to the determination of SA in synthetic samples and fresh urine samples of healthy human with satisfactory results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A new spectrofluorimetric method was reported for the determination of folic acid (FA), based on its quenching effect on the fluorescence intensity of Tb3+–1,10‐phenanthroline complex as a fluorescent probe. The quenched fluorescence intensity at an emission wavelength of 545 nm was proportional to the concentration of FA in Tris–HCl buffer solution of pH 6.2. The effects of pH, time, order of addition of reagents, temperature and concentrations of Tb3+, buffer and 1,10‐phenanthroline were investigated and optimized. The linear range for the determination of FA was 0.01–1.1 mg/L. The detection limit was 0.003 mg/L and the relative standard deviation for replicated determination of 1 mg/L of folic acid was 1.2%. This method was simple, practical and relatively free from interference effects. It was successfully applied to assess FA in pharmaceutical tablets and urine samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
A highly sensitive and simple spectrofluorimetric method for the determination of dobutamine hydrochloride based on its inhibitory effect on the hemoglobin‐catalyzed reaction of H2O2 and l ‐tyrosine was developed. The relationship between the concentration of dobutamine hydrochloride and the fluorescence quenching (ΔF) of the system is linear under the optimal experimental conditions. The calibration graph is linear in the range 2.00 × 10‐7 to 3.00 × 10‐6 g/mL with a limit of detection of 4.83 × 10‐9 g/mL. This method can be used for the determination of dobutamine hydrochloride in its pharmaceutical formulations and in urine with satisfactory results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
Increasing markets for biopharmaceuticals, including monoclonal antibodies, have triggered a permanent need for bioprocess optimization. Biochemical engineering approaches often include the optimization of basal and feed media to improve productivities of Chinese hamster ovary (CHO) cell cultures. Often, l ‐tyrosine is added as dipeptide to deal with its poor solubility at neutral pH. Showcasing IgG1 production with CHO cells, we investigated the supplementation of three l ‐tyrosine (TYR, Y) containing dipeptides: glycyl‐l ‐tyrosine (GY), l ‐tyrosyl‐l ‐valine (YV), and l ‐prolyl‐l ‐tyrosine (PY). While GY and YV led to almost no phenotypic and metabolic differences compared to reference samples, PY significantly amplified TYR uptake thus maximizing related catabolic activity. Consequently, ATP formation was roughly four times higher upon PY application than in reference samples.  相似文献   

15.
A new simple stability‐indicating spectrofluorimetric method has been developed and validated for the determination of the tyrosine kinase inhibitor, linifanib (LNF). The proposed method makes use of the native fluorescence characteristics of LNF in a micellar system. Compared with aqueous solutions, the fluorescence intensity of LNF was greatly enhanced upon the addition of Tween‐80. The relative fluorescence intensity of LNF was measured in a diluting solvent composed of 2% Tween‐80: phosphate buffer pH 8.0 (20: 80, v/v) using excitation and emission wavelengths of 290 and 450 nm, respectively. The proposed method was fully validated as per the ICH guidelines. The recorded fluorescence intensity of LNF was rectilinear over a concentration range of 0.3–2 μg/ml with a high correlation coefficient (r = 0.9990) and low limits of detection (0.091 μg/ml) and quantitation (0.275 μg/ml). The applicability of the method was extended to study the inherent stability of LNF under different stress degradation conditions including, alkaline, acidic, oxidative, photolytic and thermal degradation. Moreover, the method was utilized to study the kinetics of the alkaline and oxidative degradation of LNF. The pseudo‐first order rate constants and half‐lives were calculated.  相似文献   

16.
The quenching of fluorescence of 5-methoxyindole, N-acetyl-L-tryptophanamide and two single tryptophan containing peptides, melittin and mastoparan X, by oxidized dithiothreitol was studied. The slopes of the Stern-Volmer plots for steady-state fluorescence quenching were 133 M-1, 71.2 M-1, 75.5 M-1 and 35.0 M-1 at 21 degrees C and pH 7.0 for 5-methyoxyindole, N-acetyl-L-tryptophanamide, melittin and mastoparan X respectively. Fluorescence lifetimes of indole or tryptophan in these compounds, as determined by multifrequency phase fluorometry, were decreased by 15% or less at concentrations that produced 50% or more quenching of steady-state fluorescence. Thus, quenching of fluorescence by oxidized dithiothreitol for these derivatives of indole appears to be largely static in nature, suggesting a ground-state interaction.  相似文献   

17.
Three different spectrophotometric and two spectrofluorimetric methods have been developed and validated for the determination of vincamine (VN) and naftidrofuryl oxalate (NF) in tablets. The spectrophotometric methods depend on charge transfer complex formation between each of VN and NF with 7,7,8,8‐tetracyano‐quinodimethane (TCNQ), 2,6‐dichloroquinone‐4‐chloroimide (DCQ) and 2,3‐dichloro‐5,6‐dicyano‐1,4‐benzoquinone (DDQ) at 843, 580 and 588 nm, respectively. The spectrofluorimetric methods are based on the formation of charge transfer complex between each of the two drugs and TCNQ, with measurement of the fluorophore formed at 312/375 and 284/612 nm, respectively, or with DDQ at 400/475 and 284/396 nm, respectively. In the spectrophotometric measurements, Beer's law was obeyed at concentration ranges of 1.5–16, 10–180 and 12–140 μg/ml for VN with TCNQ, DCQ, and DDQ, respectively. For NF, the corresponding concentrations were 2–28, 5–75 and 25–150 μg/ml with TCNQ, DCQ, and DDQ, respectively. In the spectrofluorimetric measurements, the ranges for VN were 0.05–0.9 and 0.3–4 μg/ml with TCNQ and DDQ, respectively, whereas for NF the ranges were 0.05–0.85 and 0.5–8 μg/ml with TCNQ and DDQ, respectively. The different experimental parameters affecting the development and stability of the formed color or fluorophore were studied and optimized and the molar ratios of the complexes were calculated. The proposed methods were validated according to ICH guidelines and were successfully applied for the determination of VN and NF in their tablet dosage forms.  相似文献   

18.
A novel and sensitive method for the determination of ceftazidime and cefepime in an active pharmaceutical ingredient (API) has been developed based on the fluorescence quenching of poly(ethylene glycol) (PEG)2000‐capped carbon quantum dots (CQDs) prepared using a chemical oxidation method. The quenching of fluorescence intensity is proportional to the concentration of ceftazidime and cefepime over the range of 0.33–3.30 and 0.24–2.40 µg/mL, respectively. The mode of interaction between PEG2000‐capped CQDs and ceftazidime/cefepime in aqueous solutions was investigated using a fluorescence, UV/Vis and Fourier transform infrared spectrometry (FTIR) at physiological pH. UV/Vis and FTIR spectra demonstrated that ground state compounds were formed through hydrophobic interaction the fluorescence quenching of CQDs caused by ceftazidime and cefepime. The quenching constants decreased with increases in temperature, which was consistent with static quenching. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A new microbial cyclic dipeptide (diketopiperazine), cyclo(d ‐Tyr‐d ‐Phe) was isolated for the first time from the ethyl acetate extract of fermented modified nutrient broth of Bacillus sp. N strain associated with rhabditid Entomopathogenic nematode. Antibacterial activity of the compound was determined by minimum inhibitory concentration and agar disc diffusion method against medically important bacteria and the compound recorded significant antibacterial against test bacteria. Highest activity was recorded against Staphylococcus epidermis (1 µg/ml) followed by Proteus mirabilis (2 µg/ml). The activity of cyclo(d ‐Tyr‐d ‐Phe) against S. epidermis is better than chloramphenicol, the standard antibiotics. Cyclo(d ‐Tyr‐d ‐Phe) recorded significant antitumor activity against A549 cells (IC50 value: 10 μM) and this compound recorded no cytotoxicity against factor signaling normal fibroblast cells up to 100 μM. Cyclo(d ‐Tyr‐d ‐Phe) induced significant morphological changes and DNA fragmentation associated with apoptosis in A549 cells. Acridine orange/ethidium bromide stained cells indicated apoptosis induction by cyclo(d ‐Tyr‐d ‐Phe). Flow cytometry analysis showed that the cyclo(d ‐Tyr‐d ‐Phe) did not induce cell cycle arrest. Effector molecule of apoptosis such as caspase‐3 was found activated in treated cells, suggesting apoptosis as the main mode of cell death. Antioxidant activity was evaluated by free radical scavenging and reducing power activity, and the compound recorded significant antioxidant activity. The free radical scavenging activity of cyclo(d ‐Tyr‐d ‐Phe) is almost equal to that of butylated hydroxyanisole, the standard antioxidant agent. We also compared the biological activity of natural cyclo(d ‐Tyr‐d ‐Phe) with synthetic cyclo(d ‐Tyr‐d ‐Phe) and cyclo(l ‐Tyr‐l ‐Phe). Natural and synthetic cyclo(d ‐Tyr‐d ‐Phe) recorded similar pattern of activity. Although synthetic cyclo(l ‐Tyr‐l ‐Phe) recorded lower activity. But in the case of reducing power activity, synthetic cyclo(l ‐Tyr‐l ‐Phe) recorded significant activity than natural and synthetic cyclo(d ‐Tyr‐d ‐Phe). The results of the present study reveals that cyclo(d ‐Tyr‐d ‐Phe) is more bioactive than cyclo(l ‐Tyr‐l ‐Phe). To the best of our knowledge, this is the first time that cyclo(d ‐Tyr‐d ‐Phe) has been isolated from microbial natural source and also the antibacterial, anticancer, and antioxidant activity of cyclo(d ‐Tyr‐d ‐Phe) is also reported for the first time. Copyright © 2013 European Peptide Society and John Wiley & Sons, Ltd.  相似文献   

20.
A reliable, sensitive, cheap and non‐extractive spectrofluorimetric method has been developed and validated for determination of thioridazine and flupentixol based on ternary complex formation with eosin and lead(II) in the presence of methylcellulose as surfactant at pH 3.2. Under the optimum conditions, the quantitative quenching effect of investigated drugs on the native fluorescence of eosin has been investigated. The quenching of the eosin fluorescence was measured at 517 nm after excitation at 462 nm. The different experimental parameters affecting the development and stability of the reaction products were carefully studied and optimized, and the results were satisfactory. The calibration plots were constructed over the range of 0.5–3.0 µg mL?1. The developed method was successfully applied for determination of investigated drugs in commercial tablets without interference from common excipients. It was further applied for content uniformity testing of flupentixol in its tablets. Statistical comparisons of the results with those of the reference methods revealed excellent agreement and indicated no significant difference in accuracy and precision. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号