首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
目的采用三维荧光光谱分析技术对口腔常见致龋菌荧光光谱特征进行初步分析。方法选择口腔常见致龋菌变形链球菌及远缘链球菌,对其进行复苏和培养,运用三维荧光光谱分析技术对其菌液进行荧光学光谱检测。结果变形链球菌及远缘链球菌的三维荧光光谱图相似,均出现2个荧光峰,最佳激发波长分别位于230nm和280nm,最佳发射波长相同,均为340nm。结论成功获得口腔常见致龋菌(变形链球菌及远缘链球菌)的固有荧光三维光谱图,为致龋菌荧光评价技术的应用提供参考。  相似文献   

2.
Monte Carlo (MC) modeling is a valuable tool to gain fundamental understanding of light-tissue interactions, provide guidance and assessment to optical instrument designs, and help analyze experimental data. It has been a major challenge to efficiently extend MC towards modeling of bulk-tissue Raman spectroscopy (RS) due to the wide spectral range, relatively sharp spectral features, and presence of background autofluorescence. Here, we report a computationally efficient MC approach for RS by adapting the massively-parallel Monte Carlo eXtreme (MCX) simulator. Simulation efficiency is achieved through “isoweight,” a novel approach that combines the statistical generation of Raman scattered and Fluorescence emission with a lookup-table-based technique well-suited for parallelization. The MC model uses a graphics processor to produce dense Raman and fluorescence spectra over a range of 800 − 2000 cm−1 with an approximately 100× increase in speed over prior RS Monte Carlo methods. The simulated RS signals are compared against experimentally collected spectra from gelatin phantoms, showing a strong correlation.  相似文献   

3.
Despite advances in medical technology, the parathyroid glands are still damaged during thyroid surgery. Our previous studies exploring methods for locating the parathyroid glands using autofluorescence have limitations, such as turning off the surgical light or requiring additional matching between the autofluorescence image and real‐surgical field‐of‐view. We developed a probe‐type parathyroid autofluorescence detector using a phase‐sensitive process and optical filtering to overcome these limitations. A preliminary clinical trial was performed on eight parathyroid glands in four patients. The normalized mean signal of the normal parathyroid glands was 332% stronger than that of the thyroid, and 384%, 459% and 286% stronger than the signal of the muscle, trachea and fat, respectively. Additionally, the device also detected fluorescence from indocyanine green.  相似文献   

4.
Fluorescence imaging in the second near‐infrared optical window (NIR‐II, 900‐1700 nm) has become a technique of choice for noninvasive in vivo imaging in recent years. Greater penetration depths with high spatial resolution and low background can be achieved with this NIR‐II window, owing to low autofluorescence within this optical range and reduced scattering of long wavelength photons. Here, we present a novel design of confocal laser scanning microscope tailored for imaging in the NIR‐II window. We showcase the outstanding penetration depth of our confocal setup with a series of imaging experiments. HeLa cells labeled with PbS quantum dots with a peak emission wavelength of 1276 nm can be visualized through a 3.5‐mm‐thick layer of scattering medium, which is a 0.8% Lipofundin solution. A commercially available organic dye IR‐1061 (emission peak at 1132 nm), in its native form, is used for the first time, as a NIR‐II fluorescence label in cellular imaging. Our confocal setup is capable of capturing optically sectioned images of IR‐1061 labeled chondrocytes in fixed animal cartilage at a depth up to 800 μm, with a superb spatial resolution of around 2 μm.   相似文献   

5.
Cutaneous squamous cell carcinoma (cSCC) is a common skin cancer with metastatic potential. To reduce reoperations due to nonradical excision, there is a need to develop a technique for identification of tumor margins preoperatively. Photoacoustic (PA) imaging is a novel imaging technology that combines the strengths of laser optics and ultrasound. Our aim was to determine the spectral signature of cSCC using PA imaging and to use this signature to visualize tumor architecture and borders. Two‐dimensional PA images of 33 cSCCs and surrounding healthy skin were acquired ex vivo, using 59 excitation wavelengths from 680 to 970 nm. The spectral response of the cSCCs was compared to healthy tissue, and the difference was found to be greatest at wavelengths in the range 765 to 960 nm (P < .05). Three‐dimensional PA images were constructed from spectra obtained in the y‐z plane using a linear stepper motor moving along the x‐plane. Spectral unmixing was then performed which provided a clear three‐dimensional view of the distribution of tumor masses and their borders.  相似文献   

6.
We report the development of an integrated multifunctional imaging system capable of providing anatomical (optical coherence tomography, OCT), functional (OCT angiography, OCTA) and molecular imaging (light‐induced autofluorescence, LIAF) for in vivo dental applications. Blue excitation light (405 nm) was used for LIAF imaging, while the OCT was powered by a 1310 nm swept laser source. A red‐green‐blue digital camera, with a 450 nm cut‐on broadband optical filter, was used for LIAF detection. The exciting light source and camera were integrated directly with the OCT scanning probe. The integrated system used two noninvasive imaging modalities to improve the speed of in vivo OCT data collection and to better target the regions of interest. The newly designed system maintained the ability to detect differences between healthy and hypomineralized teeth, identify dental biofilm and visualize the microvasculature of gingival tissue. The development of the integrated OCT‐LIAF system provides an opportunity to conduct clinical studies more efficiently, examining changes in oral conditions over time.  相似文献   

7.
Standard fluorescence microscopy approaches rely on measurements at single excitation and emission bands to identify specific fluorophores and the setting of thresholds to quantify fluorophore intensity. This is often insufficient to reliably resolve and quantify fluorescent labels in tissues due to high autofluorescence. Here we describe the use of hyperspectral analysis techniques to resolve and quantify fluorescently labeled cells in highly autofluorescent lung tissue. This approach allowed accurate detection of green fluorescent protein (GFP) emission spectra, even when GFP intensity was as little as 15% of the autofluorescence intensity. GFP‐expressing cells were readily quantified with zero false positives detected. In contrast, when the same images were analyzed using standard (single‐band) thresholding approaches, either few GFP cells (high thresholds) or substantial false positives (intermediate and low thresholds) were detected. These results demonstrate that hyperspectral analysis approaches uniquely offer accurate and precise detection and quantification of fluorescence signals in highly autofluorescent tissues. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

8.
This clinical study is a first attempt to use autofluorescence for recurrence diagnosis of skin cancer in postoperative scars. The proposed diagnostic parameter is based on a reduction in scar autofluorescence, evaluated in the green spectral channel. The validity of the method has been tested on 110 postoperative scars from 56 patients suspected of non‐melanoma skin cancer, with eight patients (13 scars) available for the repeated examination. The recurrence diagnosis within a scar has been made after two subsequent autofluorescence check‐ups, representing the temporal difference between the scar autofluorescence amplitudes as a vector. The recognition of recurrence has been discussed to represent the significant deviations from the value of vector angle θ. This new autofluorescence‐based method can be easily integrated into the postoperative monitoring of surgical scars and can help diagnose the recurrence of skin cancer from the early stage of scar development.  相似文献   

9.
This study focuses on the characterization of bacterial and yeast species through their autofluorescence spectra. Lactic acid bacteria (Lactobacillus sp.), and yeast (Saccharomyces sp.) were cultured under controlled conditions and studied for variations in their autofluorescence, particularly in the area representative of tryptophan residues of proteins. The emission and excitation spectra clearly reveal that bacterial and yeast species can be differentiated by their intrinsic fluorescence with UV excitation. The possibility of differentiation between different strains of Saccharomyces yeast was also studied, with clear differences observed for selected strains. The study shows that fluorescence can be successfully used to differentiate between yeast and bacteria and between different yeast species, through the identification of spectroscopic fingerprints, without the need for fluorescent staining.  相似文献   

10.
This study aims to develop a novel cross‐sectional imaging of fluorescence in over‐1000 nm near‐infrared (OTN‐NIR), which allows in vivo deep imaging, using computed tomography (CT) system. Cylindrical specimens of composite of OTN‐NIR fluorophore, NaGdF4 co‐doped with Yb3+ and Ho3+ (ex: 980 nm, em: 1150 nm), were embedded in cubic agar (10.5–12 mm) or in the peritoneal cavity of mice and placed on a rotatable stage. When the fluorescence from inside of the samples was serially captured from multiple angles, the images were disrupted by the reflection and refraction of emitted light on the sample‐air interface. Immersing the sample into water filled in a rectangular bath suppressed the disruption at the interface and successfully reconstructed the position and concentration of OTN‐NIR fluorophores on the cross‐sectional images using a CT technique. This is promising as a novel three‐dimensional imaging technique for OTN‐NIR fluorescent image projections of small animals captured from multiple angles.  相似文献   

11.
Diabetes is a serious disease whose patients often require long-term care. Blood glucose and intermediate glycation product of glycated hemoglobin (HbA1c) are, at best, surrogate biomarkers of disease progression. There is indication that advanced glycation end products (AGEs) better reflect diabetic risks. In this study, we explored the use of red blood cells (RBCs) and lysed hemoglobin (Hb) autofluorescence (AF) as potential biomarkers of diabetic complication. AF spectra measured under 370 nm excitation reveals that both RBC and Hb fluorescence in the 420 to 600 nm region. At early time points following diabetic induction in rats, AF increase in lysed Hb is more dramatic compared to that of RBCs. Moreover, we found significance variance of Hb autofluorescence despite relatively constant HbA1c levels. Furthermore, we found that although a correlation exists between AGE autofluorescence and HbA1c levels, the lack of complete correspondence suggests that the rate of AGE production differs significantly among different rats. Our results suggest that with additional development, both RBC and Hb autofluorescence from lysed RBCs may be used act long-term glycemic markers for diabetic complications in patients.   相似文献   

12.
Commercially produced meat is currently graded by a complex and partly subjective multiparameter methodology; a quantitative method of grading, using small samples would be desirable. Here, we investigate the correlation between commercial grades of beef and spectral signatures of native fluorophores in such small samples. Beef samples of different commercial grades were characterized by fluorescence spectroscopy complemented by biochemical and histological assessment. The excitation‐emission matrices of the specimens reveal five prominent native autofluorescence signatures in the excitation range from 250 to 350 nm, derived mainly from tryptophan and intramuscular fat. We found that these signatures reflect meat grade and can be used for its determination.   相似文献   

13.
Multimodal low-cost endoscopy is highly desirable in poor resource settings such as in developing nations. In this work, we developed a smartphone-based low-cost, reusable tethered capsule endoscopic platform that allows white-light, narrowband, and fluorescence/autofluorescence imaging of the esophagus. The ex-vivo studies of swine esophagus were performed and compared with a commercial endoscope to test the white-light imaging capabilities of the endoscope. The efficacy of the capsule for narrow-band imaging was tested by imaging the vascularization of the tongue. To determine the autofluorescence/fluorescence capability of the endoscope, fluorescein dye with different concentrations was imaged. Furthermore, swine esophagus injected with fluorescein dye was imaged using the fluorescence/autofluorescence and the white-light imaging modules, ex-vivo. The overall cost of the capsules is approximately 12 €, 15 €, and 42 € for the white light imaging, the narrow-band imaging, and the fluorescence/autofluorescence imaging respectively. In addition, the cost of the laser source module required for the narrow-band imaging and the fluorescence/autofluorescence imaging is approximately 218 €. This device will open the possibility of imaging the esophagus in underprivileged areas.  相似文献   

14.
Monitoring fluorescence properties of endogenous fluorophores such as nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) in normal and cancerous cells provide substantial information noninvasively on biochemical and biophysical aspects of metabolic dysfunction of cancerous cells. Time‐resolved spectral profiles and fluorescence lifetime images of NADH and FAD were obtained in human lung nonsmall carcinomas (H661 and A549) and normal lung cells (MRC‐5). Both fluorophores show the fast and slowly decaying emission components upon pulsed excitation, and fluorescence spectra of NADH and FAD show blue‐ and red‐shifts, respectively, during their decay. All identified lifetime components of NADH and FAD were found to be shorter in cancerous cells than in normal cells, no matter how they were measured under different extra‐cellular conditions (cells suspended in cuvette and cells attached on glass substrate), indicating that the changes in metabolism likely altered the subcellular milieu and potentially also affected the interaction of NADH and FAD with enzymes to which these cofactors were bound. The intensity ratio of NADH and FAD of cancerous cells was also shown to be larger than that of normal cells.  相似文献   

15.
Nicotinamide adenine dinucleotide (NADH) plays a critical role in oxidative phosphorylation as the primary source of reducing equivalents to the respiratory chain. Using a modified fluorescence microscope, we have obtained spectra and images of the blue autofluorescence from single rat cardiac myocytes. The optical setup permitted rapid acquisition of fluorescence emission spectra (390-595 nm) or intensified digital video images of individual myocytes. The spectra showed a broad fluorescence centered at 447 +/- 0.2 nm, consistent with mitochondrial NADH. Addition of cyanide resulted in a 100 +/- 10% increase in fluorescence, while the uncoupler FCCP resulted in a 82 +/- 4% decrease. These two transitions were consistent with mitochondrial NADH and implied that the myocytes were 44 +/- 6% reduced under the resting control conditions. Intracellular fluorescent structures were observed that correlated with the distribution of a mitochondrial selective fluorescent probe (DASPMI), the mitochondrial distribution seen in published electron micrographs, and a metabolic digital subtraction image of the cyanide fluorescence transition. These data are consistent with the notion that the blue autofluorescence of rat cardiac myocytes originates from mitochondrial NADH.  相似文献   

16.
According to EU summary report on zoonoses, zoonotic agents and food‐borne outbreaks in 2017, Campylobacter was the most commonly reported gastrointestinal bacterial pathogen in humans in the EU. Unfortunately, the standard methods for the detection of thermotolerant Campylobacter spp. in foods are time‐consuming. Additionally, the qualified staff is obligatory. For this reason, new methods of pathogens detection are needed. The present work demonstrates that surface‐enhanced Raman scattering (SERS) is a reliable and fast method for detection of Campylobacter spp. in food samples. The proposed method combines the SERS measurements performed on an Ag/Si substrate with two initial steps of the ISO standard procedure. Finally, the principal component analysis (PCA) allows for statistical classification of the studied bacteria. By applying the proposed ISO‐SERS‐PCA method in the case of Campylobacter bacteria the total detection time may be reduced from 7 to 8 days required by ISO method to 3 to 4 days in the case of SERS‐based approach.  相似文献   

17.
Real‐time microscopic imaging of freshly excised tissue enables a rapid bedside‐pathology. A possible application of interest is the detection of oral squamous cell carcinomas (OSCCs). The aim of this study was to analyze the sensitivity and specificity of ex vivo fluorescence confocal microscopy (FCM) for OSCCs and to compare confocal images visually and qualitatively with gold standard histopathology. Two hundred eighty ex vivo FCM images were prospectively collected and evaluated immediately after excision. Every confocal image was blindly assessed for the presence or absence of malignancy by two clinicians and one pathologist. The results were compared with conventional histopathology with hematoxylin and eosin staining. OSCCs were detected with a very high sensitivity of 0.991, specificity of 0.9527, positive predictive value of 0.9322 and negative predictive value of 0.9938. The results demonstrate the potential of ex vivo FCM in fresh tissue for rapid real‐time surgical pathology.  相似文献   

18.
Time‐correlated single photon counting is the “gold‐standard” method for fluorescence lifetime measurements and has demonstrated potential for clinical deployment. However, the translation of the technology into clinic is hindered by the use of ultrasensitive detectors, which make the fluorescence acquisition impractical with bright lighting conditions such as in clinical settings. We address this limitation by interleaving periodic fluorescence detection with synchronous out‐of‐phase externally modulated light source, thus guaranteeing specimen illumination and a fluorescence signal free from bright background light upon temporal separation. Fluorescence lifetime maps are generated in real‐time from single‐point measurements by tracking a reference beam and using the phasor approach. We demonstrate the feasibility and practicality of this technique in a number of biological specimens, including real‐time mapping of degraded articular cartilage. This method is compatible and can be integrated with existing clinical microscopic, endoscopic and robotic modalities, thus offering a new pathway towards label‐free diagnostics and surgical guidance in a number of clinical applications.  相似文献   

19.
Laser-induced time-resolved autofluorescence from carious lesions of human teeth was studied by means of ultrashort pulsed laser systems, time-correlated single photon counting and time-gated imaging. Carious regions exhibited a slower fluorescence decay with a main 17 ns fluorescence lifetime than healthy hard dental tissue. The long-lived fluorophore present in carious lesions only emits in the red spectral region. Fluorescence decay time and spectral characteristics are typical of fluorescent metal-free porphyrin monomers. The spatial distribution of the long-lived endogenous porphyrin fluorophore within the tooth material was detected by time-gated nanosecond autofluorescence imaging. In particular, high contrast video images were obtained with an appropriate time delay of 15 ns to 25 ns between excitation and detection due to the suppression of short-lived autofluorescence of healthy tissue. First in vivo applications are reported indicating the potential of time-resolved fluorescence diagnostics for early caries- and dental plaque detection.  相似文献   

20.
A novel bioactive fluorescent nodulation (Nod) factor, NodRlv-IV(BODIPY FL-C16), has been synthesized by attaching a BODIPY FL-C16 acyl chain to the primary amino group of chitotetraose deacetylated at the nonreducing terminus by recombinant NodB. The binding of the fluorescent Nod factor to root systems of Vicia sativa was investigated with fluorescence spectral imaging microscopy (FSPIM) and fluorescence ratio imaging microscopy (FRIM). Spatially resolved fluorescence spectra of living and labeled Vicia sativa root systems were measured by FSPIM. Strong autofluorescence, inherent to many plant systems when excited at 488 nm, was corrected for by utilizing the difference in fluorescence emission spectra of the autofluorescence and NodRlv-IV(BODIPY FL-C16). A methodology is presented to break down the in situ fluorescence emission spectra into spatially resolved autofluorescence and BODIPY FL fluorescence spectra. Furthermore, an FRIM method was developed for correcting autofluorescence in fluorescence micrographs for this system. After autofluorescence correction it was shown that NodRlv-IV(BODIPY FL-C16) was concentrated in the root hairs, but was also bound to other parts of the root surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号