首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific LC–MS–MS assay has been developed and validated for barnidipine (1-benzyl-3-pyrrolidinyl)methyl-2,6-dimethyl-4(m-nitrophenyl)-1,4-dihydropyridine-3,5-dicarboxylate). The assay involves a simple and rapid solid-phase extraction procedure. Sample analysis was on a Spherisorb S3ODS2 100 mm×2 mm I.D. column, with a Finnigan TSQ 7000 mass spectrometer, using an electrospray interface and selective reaction monitoring (SRM). The intra- and inter-day precision and accuracy, determined as the coefficient of variation and relative error, respectively, were 11.8% or less. The limit of quantitation was 0.03 ng/ml, and the calibration was linear between 0.03 and 3.0 ng/ml. The method has been used successfully for the measurement of over two thousand human plasma samples from pharmacokinetic clinical trials.  相似文献   

2.
Gangliosides are a family of glycosphingolipids characterized by mono- or polysialic acid-containing oligosaccharides linked through 1,3- and 1,4-β glycosidic bonds with subtle differences in structure that are abundantly present in the central nervous systems of many living organisms. Their cellular surface expression and physiological malfunction are believed to be pathologically implicated in considerable neurological disorders, including Alzheimer and Parkinson diseases. Recently, studies have tentatively elucidated that mental retardation or physical stagnation deteriorates as the physiological profile of gangliosides becomes progressively and distinctively abnormal during the development of these typical neurodegenerative syndromes. In this work, a reverse-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay using standard addition calibration for determination of GM2, GM3, GD2, and GD3 in human plasma has been developed and validated. The analytes and internal standard were extracted from human plasma using a simple protein precipitation procedure. Then the samples were analyzed by reverse-phase ultra-performance liquid chromatography (UPLC)/MS/MS interfaced to mass spectrometry with electrospray ionization using a multiple reaction monitoring mode to obtain superior sensitivity and specificity. This assay was validated for extraction recovery, calibration linearity, precision, and accuracy. Our quick and sensitive method can be applied to monitor ganglioside levels in plasma from normal people and neurodegenerative patients.  相似文献   

3.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sorafenib in human plasma. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma with 0.5 mL acetonitrile. Analysis of the compounds of interest including the internal standard ([(2)H(3)(15)N] sorafenib) was achieved on a Waters X-Terra C(18) (150 mm x 2.1mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile/10 mM ammonium acetate (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 7.3-7260 ng/mL for the human plasma samples with values for the coefficient of determination of >0.96. The values for both within day and between day precision and accuracy were well within the generally accepted criteria for analytical methods (<15%).  相似文献   

4.
Carbofuran (CFN), carbosulfan (CSN) and fenobucarb (FBC) are carbamate pesticides that are widely used in gardening and agriculture for the control of insects. Human poisoning due to occupational or self-poisoning exposures is also reported, so assays are required to quantify the plasma concentration of these insecticides. An LC-MS/MS method was developed and validated for the simultaneous quantification of these three carbamate insecticides in the plasma of patients with acute intentional self-poisoning. Plasma samples were pretreated by acetonitrile for protein precipitation. Chromatography was carried out on a Luna C18(2) analytical column with gradient elution using a mobile phase containing acetonitrile and water with 10mM ammonium acetate. Mass spectrometric analysis was performed by an Applied Biosystems MDS Sciex API 2000 triple quadrupole mass spectrometer coupled with electrospray ionization (ESI) source in the positive ion mode. The total run time was 7 min. The assay was validated over a concentration range from 10 to 1000 ng/ml for CSN and FBC and 20-2000 ng/ml for CFN. The precision and accuracy for both intra- and inter-day determination of all analytes were acceptable (<15%). No significant matrix effect was observed. Stability of compounds was established for short term bench and autosampler storage as well as freeze/thaw cycles. The method was effectively applied to 270 clinical samples from patients with a history of acute intentional carbamate self-poisoning.  相似文献   

5.
We developed and validated a quantitative method for simultaneously determining the concentrations of tracheloside and trachelogenin in rat plasma. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate. Isocratic chromatographic separation was performed on a reversed-phase Diamonsil C(18) column (4.6×200 mm, 5 μm). The mobile phase consisted of methanol and 10mM aqueous ammonium formate (80:20, v/v). Analyte detection was achieved by positive electrospray ionization (ESI) tandem mass spectrometry. Calibration was performed by internal standardization with glipizide, and regression curves ranging from 0.625 to 625 ng/mL were constructed for both the analytes. The intra- and inter-day precision values were below 8%, and accuracy ranged from -5.33% to 2.53% in all quality control samples. In this study, the validated method was successfully applied to determine the pharmacokinetic profile of tracheloside and trachelogenin in rat plasma after oral and intravenous administration of trachelospermi total lignans.  相似文献   

6.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers.  相似文献   

7.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

8.
A sensitive and specific procedure for the simultaneous determination of dihydroergotamine (DHE) and its 8'-hydroxylated metabolite (8'-OH-DHE) in human plasma was developed and validated. The analytes were extracted from plasma samples by liquid-liquid extraction, separated through a Zorbax C18 column (50x2.1 mm I.D.) and detected by tandem mass spectrometry with an electrospray ionization interface. Caroverine was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 10.0 and 11.0 pg/ml for DHE and 8'-OH-DHE, respectively. The intra- and inter-run precision was measured to be below 9.1% for both DHE and 8'-OH-DHE. The inter-run accuracy was within 4% for the analytes. The overall extraction recoveries of DHE and 8'-OH-DHE were determined to be about 58 and 52% on average, respectively. The chromatographic run time was approximately 2.5 min. More than 120 samples could be assayed daily with this method, including sample preparation, data acquisition and processing. The method developed was successfully used to investigate plasma concentrations of DHE and 8'-OH-DHE in a pharmacokinetic study of volunteers who received DHE orally.  相似文献   

9.
10.
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively.  相似文献   

11.
A rapid LC-MS/MS method was developed and partially validated for the quantitation of montelukast in spiked sheep plasma. A total run time of 1.5 min was achieved using a short monolithic column and employing a rapid gradient. Sample preparation involved protein precipitation with twofold acetonitrile by volume during which a deuterated internal standard (montelukast D-6) was incorporated. The MRM transitions for montelukast and the deuterated internal standard were 586/422 and 592/427, respectively. A linear dynamic range of 0.25-500 ng/mL with a correlation coefficient of 0.9999 was achieved. Precision was below 5% at all levels except at the LOQ (0.36 ng/mL) which demonstrated an overall of R.S.D. of 8%. Post-column infusion experiments were performed with precipitated plasma matrix and showed minimal interference with the peaks of interest.  相似文献   

12.
A specific and sensitive methodology for the quantitative determination of hydroxysteroids dehydroepiandrosterone and pregnenolone and their main metabolites in human plasma is described. Hydroxysteroids were extracted using methanol and steroids were further separated by reverse-phase high-performance liquid chromatography, allowing for minimization of the possible chromatographic interferences. Eluted fractions were collected, pooled, and analyzed by gas chromatography-mass spectrometry as trimethylsilyl ether derivatives. The quantification was performed with single-ion monitoring of the highly abundant m/z 129 or m/z 358 fragments. The combination of the chromatographic characteristics to the specific fragments ensured the selectivity and specificity of the method. Under these conditions the method was linear (typical R2 is superior to 0.98 for all hydroxysteroids studied) over the concentration range of 2 x 10(-9) to 10(-6)M with good precision and accuracy.  相似文献   

13.
A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human plasma is described. The drugs were extracted from 200 μL human plasma using liquid-liquid extraction with tertiar-butylmethylether, followed by high performance liquid chromatography analysis using 10 mM ammonium hydroxide pH 10:methanol (3:7, v/v) as mobile phase. Chromatographic separation was obtained using a Zorbax Extend C(18) column. Labelled analogues of the analytes are used as internal standards. For detection, positive ionization electrospray tandem mass spectrometry was used. Method development including optimisation of the mass transitions and response, mobile phase optimisation and column selection are discussed. The method was validated according to FDA guidelines and the principles of Good Laboratory Practice (GLP). The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel and 2-2000 ng/mL for ritonavir. For quantification, quadratic calibration curves were used (r(2)>0.99). The total runtime of the method is 9 min and the assay combines analytes with differences in ionisation and desired concentration range. Inter-assay accuracy and precision were tested at four concentration levels and were within 10% and less than 10%, respectively, for all analytes. Carry-over was less than 6% and endogenous interferences or interferences between analytes and internal standards were less than 20% of the response at the lower limit of quantification level. The matrix factor and recovery were determined at low, mid and high concentration levels. The matrix factor was around 1 for all analytes and total recovery between 77.5 and 104%. Stability was investigated in stock solutions, human plasma, dry extracts, final extracts and during 3 freeze/thaw cycles. The described method was successfully applied in clinical studies with oral administration of docetaxel or paclitaxel in combination with ritonavir.  相似文献   

14.
An LC-MS/MS method was developed to quantitate the potential antitumor agent halofuginone in plasma. The assay uses 0.2 ml of plasma; chlorohalofuginone internal standard; acetonitrile for protein precipitation; a Phenomenex SYNERGI 4 micro Polar RP 80A (4 microm, 100 mm x 2 mm) column; an isocratic mobile phase of methanol:water:formic acid (80:20:0.02, v/v/v); and positive-ion electrospray ionization with selective reaction monitoring detection. Halofuginone eluted at approximately 2.4 min, internal standard eluted at approximately 2.9 min, and no endogenous materials interfered with their measurement. The assay was accurate, precise, and linear between 0.1 and 100 ng/ml. Halofuginone could be quantitated in dog plasma for at least 24 h after an i.v. dose of 0.1mg/kg. The assay is being used in ongoing pharmacokinetic studies of halofuginone.  相似文献   

15.
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for the simultaneous analysis of hydrocodone (HYC) and its metabolite hydromorphone (HYM) in human plasma. A robotic liquid handler and a 96-channel liquid handling workstation were used to aliquot samples, to add internal standard (I.S.), and to extract analytes of interest. A 96-well mixed-mode solid-phase cartridge plate was used to extract the analytes and I.S. The chromatographic separation was on a silica column (50 x 3 mm, 5-microm) with a mobile phase consisting of acetonitrile, water and trifluoroacetic acid (TFA) (92:8:0.01, v/v). The run time for each injection was 2.5 min with the retention times of approximately 2.1 and 2.2 min for HYC and HYM, respectively. The tandem mass spectrometric detection was by monitoring singly charged precursor-->product ion transition 300-->199 (m/z) for HYC, and 28-->185 (m/z) for HYM. The validated calibration curve range was 0.100-100 ng/ml, based on a plasma volume of 0.3 ml. The correlation coefficients were greater than or equal to 0.9996 for both HYC and HYM. The low limit of quantitation (LLOQ) was 0.100 ng/ml for both HYC and HYM with signal-to-noise ratio (S/N) of 50 and 10. respectively. The deuterated analytes, used as internal standards, were monitored at mass transitions 303-->199 (m/z) for HYC-d3 and 289-->185 (m/z) for HYM-d3. The inter-day (n= 17) precision of the quality control (QC) samples were < or = 3.5% RSD (relative standard deviation) for HYC and < or = 4.7% RSD for HYM, respectively. The inter-day accuracy of the QC samples were < or = 2.1% RE (relative error) for HYC and < or = 1.8% RE for HYM. The intra-day (n=6) precision and accuracy of the QC samples were < or = 2.6% RSD and < or = 3.0% RE for HYC, and < or = 4.7% RSD and < or = 2.4% RE for HYM. There was no significant deviation from the nominal values after a 5-fold dilution of high concentration QC samples by blank matrix. The QC samples were stable when kept at room temperature for 24-h or experienced three freeze-thaw cycles. The extraction recoveries were 86% for HYC and 78% for HYM. No detectable carryover was observed when a blank sample was injected immediately after a 2500 ng/ml sample that was 25-fold more concentrated than the upper limit of quantitation (ULOQ).  相似文献   

16.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for quantification of chlorpromazine in rat plasma and brain tissue. Chlorpromazine was extracted from rat plasma and brain homogenate using liquid-liquid extraction. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/20 mM ammonium formate (pH 4.25 adjusted with formic acid) with gradient elution. Chlorpromazine was detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The LLOQ was 0.2 ng/ml for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/ml for plasma and from 0.833 to 833.3 ng/g for brain tissue. The correlation coefficient (R(2)) values were more than 0.998 for both plasma and brain homogenate. The precision and accuracy for intra-day and inter-day were better than 7.54%. The relative and absolute recovery was above 84.9% and matrix effects were lower than 5.6%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of chlorpromazine after chronic treatment.  相似文献   

17.
An HPLC assay was developed using three methods of plasma sample preparation in order to quantitate curcumin, the main constituent in the herbal dietary supplement turmeric. Each method involves simple and rapid processing of samples (either an ethyl acetate or chloroform extraction) with resulting different quantitation limits for curcumin. The assay was developed in an effort to quantify extremely low curcumin plasma concentrations observed in preliminary in vivo studies. The most sensitive assay can reliably detect concentrations down to 2.5 ng/ml. Plasma quantitation was precise and accurate based on both intra- and inter-day validations as indicated by low values for coefficients of variation and bias, respectively (< or =15%). The analytical validation was reproducible between different analysts. The resulting analytical method couples desired sensitivity with the ease of an isocratic system.  相似文献   

18.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for determination of fosfomycin was developed and validated. Following protein-precipitation, the analyte and internal standard (fudosteine) were separated from human plasma using an isocratic mobile phase on an Ultimate XB-CN column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 137-->79 and m/z 178-->91 was performed to quantify fosfomycin and fudosteine, respectively. The method was linear in the concentration range of 0.10-12.0 microg/mL using 50 microL of plasma. The lower limit of quantification was 0.10 microg/mL. The intra- and inter-day relative standard deviation over the entire concentration range was less than 10.6%. Accuracy determined at three concentrations (0.25, 1.00 and 8.00 microg/mL for fosfomycin) ranged from -1.0% to -4.2% in terms of relative error. Each plasma sample was chromatographed within 5.0 min. The method was successfully used in a bioequivalence study of fosfomycin in human plasma after an oral administration of capsules containing 1.0 g fosfomycin (approximately 1.3g calcium fosfomycin).  相似文献   

19.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

20.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号