首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Aim

To evaluate the influence of the beam shape created by X-rays with “flat beams” and without “flattening-filter-free [FFF] beams” a flattening filter, and the isocenter locations for FFF beams on the treatment of a large irradiated volume for tumours.

Background

The increase of dose rate and the decrease of out-of-field dose can be expected for FFF beams and lead to effective and safety radiotherapy. On the other hand, the bell-shaped dose profile is thought to be a factor of negating these advantages.

Materials and methods

Treatment plans for 15 patients with head and neck cancer were created using XiO (Elekta, Stockholm AB, Sweden) in fixed-gantry step-and-shoot delivery under the same dose constraints. Seven fields of FFF beams with 7?MV and flat beams with 6?MV were used with the technique of intensity-modulated radiation therapy (IMRT). We compared the dose homogeneity and conformity of targets and dose constraints for organs as the plan quality and evaluated physical parameters: monitor unit (MU) values, number of segments and their locations from the isocenter in beam's-eye-view.

Results

No significant differences were found in the plan quality. The isocenter locations do not affect the physical parameters for FFF beams. It has been confirmed that the number of segments and MU values were 40% higher with FFF beams than with flat beams (p?<?0.05).

Conclusion

This study demonstrates flat dose distribution is more suitable for IMRT with large and complex targets.  相似文献   

2.
Although highly conformal dose distributions can be achieved by IMRT planning, this often requires a large number of segments or beams, resulting in increased treatment times. While flattening-filter-free beams offer a higher dose rate, even more segments may be required to create homogeneous target coverage. Therefore, it is worthwhile to systematically investigate the dependence of plan quality on gantry angles and number of segments for flat vs. FFF beams in IMRT planning. For the practical example of hypopharynx cancer, we present a planning study of flat vs. FFF beams using three different configurations of gantry angles and different segment numbers. The two beams are very similar in physical properties, and are hence well-suited for comparative planning. Starting with a set of plans of equal quality for flat and FFF beams, we assess how far the number of segments can be reduced before the plan quality is markedly compromised, and compare monitor units and treatment times for the resulting plans. As long as a sufficiently large number of segments is permitted, all planning scenarios give good results, independently of gantry angles and flat or FFF beams. For smaller numbers of segments, plan quality decreases both for flat and FFF energies; this effect is stronger for fewer gantry angles and for FFF beams. For low segment numbers, FFF plans are generally worse than the corresponding flat beam plans, but they are less sensitive to a decrease in segment number if many gantry angles are used (18 beams); in this case the quality of flat and FFF plans remains comparable even for few segments.  相似文献   

3.
BackgroundThe aim was to study the impact of the flattening filter free (FFF) beam on overall treatment time for frameless intracranial radiosurgery using TrueBeam® LINAC.The development of frameless stereotactic radiosurgery (SRS) is possible due to the incorporation of image guidance in the delivery of treatment. It is important to analyze the cost and benefits of FFF beams for treating SRS by understanding the impact of FFF beams in reducing the treatment time.Materials and methodsDynamic conformal arc (DCA ) and volumetric arc therapy (VMAT) plans were generated using 6 MV with a flattening filter (FF) and FFF beams. Overall treatment time was divided into beam on time (BOT) and beam off time (BFT). Percentage beam on time reduction (PBOTR) and Percentage total time reduction (PTTR) factors were defined for the comparison.ResultsBOT reduction was observed to be significant for higher dose per fraction but subjected to the treatment technique and modulation differences. PBOTR values are much higher than PTTR values. The 39.9% of PBOTR resulted in only 8% PTTR for DCA and 65.3% resulted in 15.9% PTTR for VMAT.ConclusionMajor BFT was utilized for imaging and verification. FFF beam significantly reduced the beam on time and was found to be most effective if the fractional dose was as high as that for SRS. Newly defined PBOTR and PTTR factors are very useful indicators to evaluate the efficacy of FFF beams in terms of time reduction.  相似文献   

4.
This study investigates the superficial dose from FFF beams in comparison with the conventional flattened ones using a Monte Carlo (MC) method. Published phase-space files which incorporated real geometry of a TrueBeam accelerator were used for the dose calculation in phantom and clinical cases. The photon fluence on the central axis is 3 times that of a flattened beam for a 6 MV FFF beam and 5 times for a 10 MV beam. The mean energy across the field in air at the phantom surface is 0.92–0.95 MeV for the 6 MV FFF beam and 1.18–1.30 MeV for the corresponding flattened beam. At 10 MV, the values are 1.52–1.72 and 2.15–2.87 MeV for the FFF and flattened beams, respectively. The phantom dose at the depth of 1 mm in the 6 MV FFF beam is 6% ± 2.5% (of the maximum dose) higher compared to the flattened beam for a 25 × 25 cm2 field and 14.6% ± 1.9% for the 2 × 2 cm2 field. For the 10 MV beam, the corresponding differences are 3.4% ± 1.5% and 10.7% ± 0.6%. The skin dose difference at selected points on the patient's surface between the plans using FFF and flattened beams in the head-and-neck case was 6.5% ± 2.3% (1SD), and for the breast case it was 6.4% ± 2.3%. The Monte Carlo simulations showed that due to the lower mean energy in the FFF beam, the clinical superficial dose is higher without the flattening filter compared to the flattened beam.  相似文献   

5.
IntroductionThe aim of this study was to evaluate the performance of a knowledge-based planning (KBP) model for breast cancer trained on plans performed on a conventional linac with 6 MV FF (flattening filter) beams and volumetric-modulated arc therapy (VMAT) for plans performed on the new jawless Halcyon© system with 6 MV FFF (flattening filter-free) beams.Materials and methodsBased on the RapidPlan© (RP) KBP optimization engine, a DVH Estimation Model was first trained using 56 VMAT left-sided breast cancer treatment plans performed on a conventional linac, and validated on another 20 similar cases (without manual intervention). To determine the capacity of the model for Halcyon©, an additional cohort of 20 left-sided breast cancer plans was generated with RP and analyzed for both TrueBeam© and Halcyon© machines. Plan qualities between manual vs RP (followed by manual intervention) Halcyon© plans set were compared qualitatively by blinded review by radiation oncologists for 10 new independent plans.ResultsHalcyon© plans generated with the VMAT model trained with conventional linac plans showed comparable target dose distribution compared to TrueBeam© plans. Organ sparing was comparable between the 2 devices with a slight decrease in heart dose for Halcyon© plans. Nine out of ten automatically generated Halcyon© plans were preferentially chosen by the radiation oncologists over the manually generated Halcyon© plans.ConclusionA VMAT KBP model driven by plans performed on a conventional linac with 6 MV FF beams provides high quality plans performed with 6 MV FFF beams on the new Halcyon© linac.  相似文献   

6.

Aim

To measure and compare the head scatter factor for 7 MV unflattened and 6 MV flattened photon beam using a home-made designed mini phantom.

Background

The head scatter factor (Sc) is one of the important parameters for MU calculation. There are multiple factors that influence the Sc values, like accelerator head, flattening filter, primary and secondary collimators.

Materials and methods

A columnar mini phantom was designed as recommended by AAPM Task Group 74 with high and low atomic number material for measurement of head scatter factors at 10 cm and dmax dose water equivalent thickness.

Results

The Sc values measured with high-Z are higher than the low-Z mini phantoms observed for both 6MV-FB and 7MV-UFB photon energies. Sc values of 7MV-UFB photon beams were smaller than those of the 6MV-FB photon beams (0.6–2.2% (Primus), 0.2–1.4% (Artiste) and 0.6–3.7% (Clinac iX (2300CD))) for field sizes ranging from 10 cm × 10 cm to 40 cm × 40 cm. The SSD had no influence on head scatter for both flattened and unflattened beams. The presence of wedge filters influences the Sc values. The collimator exchange effects showed that the opening of the upper jaw increases Sc irrespective of FF and FFF.

Conclusions

There were significant differences in Sc values measured for 6MV-FB and unflattened 7MV-UFB photon beams over the range of field sizes from 10 cm × 10 cm to 40 cm × 04 cm. Different results were obtained for measurements performed with low-Z and high-Z mini phantoms.  相似文献   

7.
PurposeWe experimentally determined the radiophotoluminescent glass dosimeter (RPLD) dose responses for TomoTherapy, CyberKnife, and flattening-filter-free (FFF) linear accelerator (linac) outputs for dosimetry audits in Japan.MethodsA custom-made solid phantom with a narrow central-axis spacing of three RPLD elements was used for output measurement to minimise the dose-gradient effect of the non-flattening filter beams. For RPLD dose estimation, we used the ISO 22127 formalism. Additional unit-specific correction factors were introduced and determined via the measured data. For TomoTherapy (7 units) and CyberKnife (4 units), the doses were measured under machine-specific reference fields. For FFF linac (5 units), in addition to the reference condition, we obtained the field-size effects for the range from 5×5 cm to 25×25 cm.ResultsThe correction factors were estimated as 1.008 and 0.999 for TomoTherapy and CyberKnife, respectively. For FFF linac, they ranged from 1.011 to 0.988 for 6 MV and from 1.011 to 0.997 for 10 MV as a function of the side length of the square field from 5 to 25 cm. The estimated uncertainties of the absorbed dose to water measured by RPLD for the units were 1.32%, 1.35%, and 1.30% for TomoTherapy, CyberKnife, and FFF linac, respectively. A summary of the dosimetry audits of these treatment units using the obtained correction factors is also presented. The average percentage differences between the measured and hospital-stated doses were <1% under all conditions.ConclusionRPLD can be successfully used as a dosimetry audit tool for modern treatment units.  相似文献   

8.
PurposeRestricted studies comparing different dose rate parameters are available while ITV-based VMAT lung SBRT planning leads to perform the analysis of the most suitable parameters of the external beams used. The special emphasis was placed on the impact of dose rate on dose distribution variations in target volumes due to interplay effects.MethodsFour VMAT plans were calculated for 15 lung tumours using 6 MV photon beam quality (flattening filter FF vs. flattening filter free FFF beams) and maximum dose rate of 600 MU/min, 1000 MU/min and 1400 MU/min. Three kinds of motion simulations were performed finally giving 180 plans with perturbed dose distributions.Results6FFF-1400 MUs/min plans were characterized by the shortest beam on time (1.8 ± 0.2 min). Analysing the performed motion simulation results, the mean dose (Dmean) is not a sensitive parameter to related interplay effects. Looking for local maximum and local minimum doses, some discrepancies were found, but their significance was presented for individual patients, not for the whole cohort. The same was observed for other verified dose metrics.ConclusionsGenerally, the evaluation of VMAT robustness between FF and FFF concepts against interplay effect showed a negligible effect of simulated motion influence on tumour coverage among different photon beam quality parameters. Due to the lack of FFF beams, smaller radiotherapy centres are able to perform ITV-based VMAT lung SBRT treatment in a safe way. Radiotherapy department having FFF beams could perform safe, fast and efficient ITV-based VMAT lung SBRT without a concern about significance of interplay effects.  相似文献   

9.
AimTo show our preliminary experience in using TrueBeam with RapidArc technology and FFF beam for stereotactic re-irradiation of nasopharyngeal carcinoma.BackgroundThanks to new advanced techniques, as well as intensity modulated radiation therapy, it is possible to approach head and neck recurrences in selected patients. Volumetric Modulated Arc Therapy (VMAT) in its RapidArc® format, permits to reduce significantly the time to deliver complex intensity modulated plans, allowing to treat hypofractionated regimes within a few minutes. With TrueBeam it is possible to perform photon beams without usage of the flattening filter. It seems possible to expect a reduction of out-of-field dose when flattening filter free (FFF) beams are used. While research into the physics domain for FFF beams is increasing, there are very few clinical data where FFF beams are applied in clinical practice.Materials and methodsWe present here the cases of 4 patients with local or regional recurrence of nasopharyngeal carcinoma. All patients were treated using TrueBeam with RapidArc technology and FFF beam for stereotactic hypofractionated re-irradiation.ResultsAll patients concluded SBRT and showed good tolerability. During follow-up, complete response at imaging evaluation (PET and/or MRI) for all treated patients was documented.ConclusionsOur preliminary experience using TrueBeam with RapidArc technology and FFF beam for stereotactic hypofractionated re-irradiation of nasopharyngeal carcinoma was safe and effective in all 4 treated patients. Longer follow-up and a larger population of study is needed to confirm these promising results.  相似文献   

10.

Background

Medical Linear accelerators manufactured without flattening filters are increasing popular in recent days. The removal of flattening filter results in increased dose rate, reduced mean energy, reduction in head leakage and lateral scattering, which have shown advantageous when used for special treatment procedures.

Aim

This study aims to analyze physical parameters of FFF beams and to determine the inflection point for standardizing the beam flatness and penumbra.

Materials and methods

The beam profiles and depth dose patterns were measured using Radiation Field Analyzer (RFA) with 0.13 cc cylindrical ion chamber. The beam energy characteristics, head scatter factor (Sc) were obtained for 6FFF and 10FFF beams and compared with 6 MV and 10 MV photons, respectively. The symmetry and stability of unflattened regions were also analyzed. In addition, the study proposes a simple physical concept for obtaining inflection point for FFF beams and results were compared using the Akima spline interpolation method. The inflection point was used to determine the field size and penumbra of FFF beams.

Results

The Sc varied from 0.922 to 1.044 for 6FFF and from 0.913 to 1.044 for 10FFF with field sizes from 3 cm × 3 cm to 40 cm × 40 cm which is much less than FF beams. The obtained value of field size and penumbra for both simple physical concept and Akima spline interpolation methods is within the ±1.0 mm for the field size and ±2 mm penumbra. The results indicate that FFF beams reduce Sc compared with FF beams due to the absence of a flattening filter.

Conclusion

The proposed simple method to find field size and penumbra using inflection point can be accepted as it is closely approximated to mathematical results. Stability of these parameters was ascertained by repeated measurements and the study indicates good stability for FFF beam similar to that of FF beams.  相似文献   

11.
MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.  相似文献   

12.
PurposeFlattening filter free (FFF) beams are frequently used for stereotactic body radiation therapy with various treatment modalities: conventional static fields, dynamic conformal arc (DCA) or Rapid Arc (RA). The goal of this study was to obtain some criteria to enable a conscious choice of the employment of FFF beams and of the DCA or RA technique, depending on the PTV size.Methods and materials24 PTVs from 1.52 cm3 to 445.24 cm3 were studied in various sites: virtual phantom, lung and liver. For each PTV, DCA and RA plans were prepared using two flattened (FF) and two unflattened photon beams. Parameters such as conformity index, gradient index, healthy-tissue and organs at risk mean doses, number of monitor units (MU), beam on time (BOT) were used to quantify obtained dose distributions. Friedman tests and Spearman’s rank correlation coefficients were also performed.ResultsNo significant differences were found between FF and FFF beams for RA regarding conformity and gradient indices. For DCA, 10FFF is less suitable and forward planning becomes more challenging as PTV volume increases. FFF beams provided a better sparing of healthy-tissues except for 10FFF used with DCA. 6FFF was slightly better than 10FFF in terms of healthy-tissue mean doses. FFF beams generated significantly reduced BOTs and increased MUs. These effects were more pronounced for larger volumes and especially for RA plans.ConclusionsFFF showed better results than FF beams for the considered plans. 10FFF used with DCA should be used with caution for medium and large volumes.  相似文献   

13.
14.
Characterizing the biological effects of flattening filter-free (FFF) X-ray beams from linear accelerators is of importance, due to their increasing clinical availability. The purpose of this work is to determine whether in vitro cell survival is affected by the higher dose-per-pulse present in FFF beams in comparison with flattened X-ray beams. A Varian TrueBeam® linear accelerator was used to irradiate the T98G, V79-4 and U87-MG cell lines with a single fraction of 5 Gy or 10 Gy doses of X-rays. Beams with energies of 6 MegaVolt (MV), 6 MV FFF and 10 MV FFF were used, with doses-per-pulse as measured at the monitor chamber of 0.28, 0.78 and 1.31 mGy/pulse for 6 MV, 6 MV FFF and 10 MV FFF, respectively. The dose delivered to each Petri dish was verified by means of ionization chamber measurements. No statistically significant effects on survival fraction were observed for any of the cell lines considered, either as a function of dose-per-pulse, average dose rate or total dose delivered. Biological effects of higher instantaneous rates should not be excluded on the basis of in vitro experimental results such as the ones presented in this work. The next step toward an assessment of the biological impact of FFF beams will require in vivo studies.  相似文献   

15.

Aim

Lipiodol was used for stereotactic body radiotherapy combining trans arterial chemoembolization. Lipiodol used for tumour seeking in trans arterial chemoembolization remains in stereotactic body radiation therapy. In our previous study, we reported the dose enhancement effect in Lipiodol with 10× flattening-filter-free (FFF). The objective of our study was to evaluate the dose enhancement and energy spectrum of photons and electrons due to the Lipiodol depth with flattened (FF) and FFF beams.

Methods

FF and FFF for 6 MV beams from TrueBeam were used in this study. The Lipiodol (3 × 3 × 3 cm3) was located at depths of 1, 3, 5, 10, 20, and 30 cm in water. The dose enhancement factor (DEF) and the energy fluence were obtained by Monte Carlo calculations of the particle and heavy ion transport code system (PHITS).

Results

The DEFs at the centre of Lipiodol with the FF beam were 6.8, 7.3, 7.6, 7.2, 6.1, and 5.7% and those with the FFF beam were 20.6, 22.0, 21.9, 20.0, 12.3, and 12.1% at depths of 1, 3, 5, 10, 20, and 30 cm, respectively, where Lipiodol was located in water. Moreover, spectrum results showed that more low-energy photons and electrons were present at shallow depth where Lipiodol was located in water. The variation in the low-energy spectrum due to the depth of the Lipiodol position was more explicit with the FFF beam than that with the FF beam.

Conclusions

The current study revealed variations in the DEF and energy spectrum due to the depth of the Lipiodol position with the FF and FFF beams. Although the FF beam could reduce the effect of energy dependence due to the depth of the Lipiodol position, the dose enhancement was overall small. To cause a large dose enhancement, the FFF beam with the distance of the patient surface to Lipiodol within 10 cm should be used.  相似文献   

16.
BackgroundHigh-energy photon and electron therapeutic beams generated in medical linear accelerators can cause the electronuclear and photonuclear reactions in which neutrons with a broad energy spectrum are produced. A low-energy component of this neutron radiation induces simple capture reactions from which various radioisotopes originate and in which the radioactivity of a linac head and various objects in the treatment room appear.AimThe aim of this paper is to present the results of the thermal/resonance neutron fluence measurements during therapeutic beam emission and exemplary spectra of gamma radiation emitted by medical linac components activated in neutron reactions for four X-ray beams and for four electron beams generated by various manufacturers’ accelerators installed in typical concrete bunkers in Polish oncological centers.Materials and methodsThe measurements of neutron fluence were performed with the use of the induced activity method, whereas the spectra of gamma radiation from decays of the resulting radioisotopes were measured by means of a portable high-purity germanium detector set for field spectroscopy.ResultsThe fluence of thermal neutrons as well as resonance neutrons connected with the emission of a 20 MV X-ray beam is ~106 neutrons/cm2 per 1 Gy of a dose in water at a reference depth. It is about one order of magnitude greater than that for the 15 MV X-ray beams and about two orders of magnitude greater than for the 18–22 MeV electron beams regardless of the type of an accelerator.ConclusionThe thermal as well as resonance neutron fluence depends strongly on the type and the nominal potential of a therapeutic beam. It is greater for X-ray beams than for electrons. The accelerator accessories and other large objects should not be stored in a treatment room during high-energy therapeutic beam emission to avoid their activation caused by thermal and resonance neutrons. Half-lives of the radioisotopes originating from the simple capture reaction (n,γ) (from minutes to hours) are long enough to accumulate radioactivity of components of the accelerator head. The radiation emitted by induced radioisotopes causes the additional doses to staff operating the accelerators.  相似文献   

17.

Purpose

Flattening filter free (FFF) beams show the potential for a higher dose rate and lower peripheral dose. We investigated the planning study of FFF beams with their role for volumetric modulated arc therapy (VMAT) in squamous cell carcinoma of the scalp.

Methods and Materials

One patient with squamous cell carcinoma which had involvement of entire scalp was subjected to VMAT using TrueBeam linear accelerator. As it was a rare skin malignancy, CT data of 7 patients with brain tumors were also included in this study, and their entire scalps were outlined as target volumes. Three VMAT plans were employed with RapidArc form: two half-field full-arcs VMAT using 6 MV standard beams (HFF-VMAT-FF), eight half-field quarter-arcs VMAT using 6 MV standard beams (HFQ-VMAT-FF), and HFQ-VMAT using FFF beams (HFQ-VMAT-FFF). Prescribed dose was 25×2 Gy (50 Gy). Plan quality and efficiency were assessed for all plans.

Results

There were no statistically significant differences among the three VMAT plans in target volume coverage, conformity, and homogeneity. For HFQ-VMAT-FF plans, there was a significant decrease by 12.6% in the mean dose to the brain compared with HFF-VMAT-FF. By the use of FFF beams, the mean dose to brain in HFQ-VMAT-FFF plans was further decreased by 7.4% compared with HFQ-VMAT-FF. Beam delivery times were similar for each technique.

Conclusions

The HFQ-VMAT-FF plans showed the superiority in dose distributions compared with HFF-VMAT-FF. HFQ-VMAT-FFF plans might provide further normal tissue sparing, particularly in the brain, showing their potential for radiation therapy in squamous cell carcinoma of the scalp.  相似文献   

18.
PurposeFlattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named “Octa” and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison.MethodsOutput factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry.ResultsThe dosimeter was shown to be a ‘correction-free’ silicon array detector for OFs and PDD measurements for all the beam qualities investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications.ConclusionsResults were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualities and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.  相似文献   

19.
BackgroundThe most common secondary cancer is contralateral breast (CLB) cancer after whole breast irradiation (WBI). The aim of this study was to quantify the reduction of CLB dose in tangential intensity modulated radiotherapy (t-IMRT) for WBI using flattening-filter-free (FFF) beams.Materials and methodsWe generated automated planning of 20 young breast cancer patients with limited user interaction. Dose-volume histograms of the planning target volume (PTV), ipsilateral lung, heart, and CLB were calculated. The dose of PTV, the most medial CLB point, and the CLB point below the nipple was measured using an ionization chamber inserted in a slab phantom. We compared the two t-IMRT plans generated by FFF beams and flattening-filter (FF) beams.ResultsAll plans were clinically acceptable. There was no difference in the conformal index, the homogeneity for FFF was significantly worse. For the ipsilateral lung, the maximum dose (Dmax) was significantly higher; however, V20 showed a tendency to be lower in the FFF plan. No differences were found in the Dmax and V30 to the heart of the left breast cancer. FF planning showed significantly lower Dmax and mean dose to the CLB. In contrast to the calculation results, the measured dose of the most medial CLB point and the CLB point below the nipple were significantly lower in FFF mode than in FF mode, with mean reductions of 21.1% and 20%, respectively.ConclusionsT-IMRT planning using FFF reduced the measured out-of-field dose of the most medial CLB point and the CLB point below the nipple.  相似文献   

20.

Purpose

To evaluate the dosimetric impacts of flattening filter-free (FFF) beams in intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for sinonasal cancer.

Methods

For fourteen cases, IMRT and VMAT planning was performed using 6-MV photon beams with both conventional flattened and FFF modes. The four types of plans were compared in terms of target dose homogeneity and conformity, organ-at-risk (OAR) sparing, number of monitor units (MUs) per fraction, treatment time and pure beam-on time.

Results

FFF beams led to comparable target dose homogeneity, conformity, increased number of MUs and lower doses to the spinal cord, brainstem and normal tissue, compared with flattened beams in both IMRT and VMAT. FFF beams in IMRT resulted in improvements by up to 5.4% for sparing of the contralateral optic structures, with shortened treatment time by 9.5%. However, FFF beams provided comparable overall OAR sparing and treatment time in VMAT. With FFF mode, VMAT yielded inferior homogeneity and superior conformity compared with IMRT, with comparable overall OAR sparing and significantly shorter treatment time.

Conclusions

Using FFF beams in IMRT and VMAT is feasible for the treatment of sinonasal cancer. Our results suggest that the delivery mode of FFF beams may play an encouraging role with better sparing of contralateral optic OARs and treatment efficiency in IMRT, but yield comparable results in VMAT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号