首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 639 毫秒
1.
Background and purpose: Accelerator-Based Boron Neutron Capture Therapy is a radiotherapy based on compact accelerator neutron sources requiring an epithermal neutron field for tumour irradiations. Neutrons of 10 keV are considered as the maximum optimised energy to treat deep-seated tumours. We investigated, by means of Monte Carlo simulations, the epithermal range from 10 eV to 10 keV in order to optimise the maximum epithermal neutron energy as a function of the tumour depth.Methods: A Snyder head phantom was simulated and mono-energetic neutrons with 4 different incident energies were used: 10 eV, 100 eV, 1 keV and 10 keV. 10B capture rates and absorbed dose composition on every tissue were calculated to describe and compare the effects of lowering the maximum epithermal energy. The Therapeutic Gain (TG) was estimated considering the whole brain volume.Results: For tumours seated at 4 cm depth, 10 eV, 100 eV and 1 keV neutrons provided respectively 54%, 36% and 18% increase on the TG compared to 10 keV neutrons. Neutrons with energies between 10 eV and 1 keV provided higher TG than 10 keV neutrons for tumours seated up to 6.4 cm depth inside the head. The size of the tumour does not change these results.Conclusions: Using lower epithermal energy neutrons for AB-BNCT tumour irradiation could improve treatment efficacy, delivering more therapeutic dose while reducing the dose in healthy tissues. This could lead to new Beam Shape Assembly designs in order to optimise the BNCT irradiation.  相似文献   

2.

Aim

To employ the thermal neutron background that affects the patient during a traditional high-energy radiotherapy treatment for BNCT (Boron Neutron Capture Therapy) in order to enhance radiotherapy effectiveness.

Background

Conventional high-energy (15–25 MV) linear accelerators (LINACs) for radiotherapy produce fast secondary neutrons in the gantry with a mean energy of about 1 MeV due to (γ, n) reaction. This neutron flux, isotropically distributed, is considered as an unavoidable undesired dose during the treatment. Considering the moderating effect of human body, a thermal neutron fluence is localized in the tumour area: this neutron background could be employed for BNCT by previously administering 10B-Phenyl-Alanine (10BPA) to the patient.

Materials and methods

Monte Carlo simulations (MCNP4B-GN code) were performed to estimate the total amount of neutrons outside and inside human body during a traditional X-ray radiotherapy treatment.Moreover, a simplified tissue equivalent anthropomorphic phantom was used together with bubble detectors for thermal and fast neutron to evaluate the moderation effect of human body.

Results

Simulation and experimental results confirm the thermal neutron background during radiotherapy of 1.55E07 cm−2 Gy−1.The BNCT equivalent dose delivered at 4 cm depth in phantom is 1.5 mGy-eq/Gy, that is about 3 Gy-eq (4% of X-rays dose) for a 70 Gy IMRT treatment.

Conclusions

The thermal neutron component during a traditional high-energy radiotherapy treatment could produce a localized BNCT effect, with a localized therapeutic dose enhancement, corresponding to 4% or more of photon dose, following tumour characteristics. This BNCT additional dose could thus improve radiotherapy, acting as a localized radio-sensitizer.  相似文献   

3.
The Kansai BNCT Medical Center has a cyclotron based epithermal neutron source for clinical Boron Neutron Capture Therapy. The system accelerates a proton to an energy of 30 MeV which strikes a beryllium target producing fast neutrons which are moderated down to epithermal neutrons for BNCT use. While clinical studies in the past have shown BNCT to be highly effective for malignant melanoma of the skin, to apply BNCT for superficial lesions using this system it is necessary to shift the thermal neutron distribution so that the maximum dose occurs near the surface. A dose distribution shifter was designed to fit inside the collimator to further moderate the neutrons to increase the surface dose and reduce the dose to the underlying normal tissue. Pure polyethylene was selected, and a Monte Carlo simulation was performed to determine the optimum thickness of the polyethylene slab. Compared with the original neutron beam, the shifter increased the thermal neutron flux at the skin by approximately 4 times. The measured and simulated central axis depth distribution and off axis distribution of the thermal neutron flux were found to be in good agreement. Compared with a 2 cm thick water equivalent bolus, a 26% increase in the thermal neutron flux at the surface was obtained, which would reduce the treatment time by approximately 29%. The DDS is a safe, simple and an effective tool for the treatment of superficial tumours for BNCT if an initially fast neutron beam requires moderation to maximise the thermal neutron flux at the tissue surface.  相似文献   

4.
Boron neutron capture therapy (BNCT) is a binary treatment involving selective accumulation of boron carriers in a tumor followed by irradiation with a thermal or epithermal neutron beam. The neutron capture reaction with a boron-10 nucleus yields high linear energy transfer (LET) particles, alpha and 7Li, with a range of 5 to 9 µm. These particles can only travel very short distances and release their damaging energy directly into the cells containing the boron compound. We aimed to evaluate proliferation, apoptosis and extracellular matrix (ECM) modifications of B16F10 melanoma and normal human melanocytes after BNCT. The amounts of soluble collagen and Hsp47, indicating collagen synthesis in the ECM, as well as the cellular markers of apoptosis, were investigated. BNCT decreased proliferation, altered the ECM by decreasing collagen synthesis and induced apoptosis by regulating Bcl-2/Bax in melanoma. Additionally, BNCT also increased the levels of TNF receptor and the cleaved caspases 3, 7, 8 and 9 in melanoma. These results suggest that multiple pathways related to cell death and cell cycle arrest are involved in the treatment of melanoma by BNCT.  相似文献   

5.
Boron Neutron Capture Therapy (BNCT) is a binary radiotherapy method developed to treat patients with certain malignant tumours. To date, over 300 treatments have been carried out at the Finnish BNCT facility in various on-going and past clinical trials. In this technical review, we discuss our research work in the field of medical physics to form the groundwork for the Finnish BNCT patient treatments, as well as the possibilities to further develop and optimize the method in the future. Accordingly, the following aspects are described: neutron sources, beam dosimetry, treatment planning, boron imaging and determination, and finally the possibilities to detect the efficacy and effects of BNCT on patients.  相似文献   

6.
PurposeBoron Neutron Capture Therapy (BNCT) is a form of hadrontherapy based on the selective damage caused by the products of neutron capture in 10B to tumour cells. BNCT dosimetry strongly depends on the parameters of the dose calculation models derived from radiobiological experiments. This works aims at determining an adequate dosimetry for in-vitro experiments involving irradiation of monolayer-cultured cells with photons and BNCT and assessing its impact on clinical settings.M&MDose calculations for rat osteosarcoma UMR-106 and human metastatic melanoma Mel-J cell survival experiments were performed using MCNP, transporting uncharged particles for KERMA determinations, and secondary particles (electrons, protons, 14C, 4He and 7Li) to compute absorbed dose in cultures. Dose-survival curves were modified according to the dose correction factors determined from computational studies. New radiobiological parameters of the photon isoeffective dose models for osteosarcoma and metastatic melanoma tumours were obtained. Dosimetry implications considering cutaneous melanoma patients treated in Argentina with BNCT were assessed and discussed.ResultsKERMA values for the monolayer-cultured cells overestimate absorbed doses of radiation components of interest in BNCT. Detailed dose calculations for the osteosarcoma irradiation increased the relative biological effectiveness factor RBE1% of the neutron component in more than 30%. The analysis based on melanoma cases reveals that the use of survival curves based on KERMA leads to an underestimation of the tumour doses delivered to patients.ConclusionsConsidering detailed dose calculation for in-vitro experiments significantly impact on the prediction of the tumor control in patients. Therefore, proposed methods are clinically relevant.  相似文献   

7.
《Médecine Nucléaire》2007,31(9):506-513
Internal targeted radiotherapy (ITR), which consists in irradiation of small disseminated tumour lesions using injected radiopharmaceuticals has been for a long time successfully used for differentiated thyroid carcinoma treatment, as an adjuvant treatment after surgery, but as an efficient treatment of metastatic disease (especially lung involvement) as well. New efficient radiopharmaceuticals for tumour targeting become available, making feasible such successful ITR treatment for other endocrine tumours (ET). Malignant phaeochromocytomas have firstly been treated with 131I-metaiodobenzyguanidine (MIBG) and more recently radiolabeled ligands of somatostatine receptors (SSR) which are overexpressed by most of ET have been proved to be an effective treatment of these tumours. Moreover, radiolabelled antibodies, which have been used successfully in malignant lymphoma treatment, could have an interest in ET, mainly medullary thyroid carcinoma. Using ITR for ET treatment suppose clinical indications are well defined, according to the new WHO classification of ET: only non-differentiated not eradicable and/or metastatic progressive tumours should be treated. Furthermore, efficiency of ITR is greater than could be thought as minor responses and even prolonged stabilizations are now considered as positive responses. Randomized studies are still necessary, however, in order to demonstrate, beyond its efficiency, a clinical impact of ITR on quality of life and survival, and to determine the right place of ITR in the global therapeutic management of ET.  相似文献   

8.
ZCCHC14 is a CCHC-type zinc finger protein which is expressed in tissues in human and mouse. The function of ZCCHC14 in tumours remains unclear. In this research, we explored the expression, function and related molecular mechanisms of ZCCHC14 in human non–small cell lung cancer (NSCLC). Immunochemistry staining showed that ZCCHC14 was low-expressed or absent in NSCLC tissues. In NSCLC patients, the low expression of ZCCHC14 in tumour tissues was significantly correlated with TNM stage, differentiation degree and adverse clinical outcome (P < .05). The proliferation and invasion ability of cancer cells transfected with ZCCHC14 CRISPR/Ca9 KO plasmids was significantly enhanced (P < .05). Immunoblotting analysis indicated that the expression of p-P38, cyclinD1 and MMP7 were significantly up-regulated after disabling ZCCHC14 (P < .05). We used MAPK-P38 pathway inhibitor doramapimod (BIRB 796) to inhibit P38 signalling pathway activity and determined that the agent significantly disrupted the function of ZCCHC14 and hindered the proliferation and invasion of the tumour. The finding revealed that ZCCHC14 can regulate proliferation and invasion of NSCLC through the P38 pathway. ZCCHC14 plays a crucial regulatory role in the development of NSCLC and may become a zinc finger target for clinical treatment.  相似文献   

9.

Background

Glioblastoma multiform (GBM) is the most common and most aggressive type of primary brain tumour in humans. It has a very poor prognosis despite multi-modality treatments consisting of open craniotomy with surgical resection, followed by chemotherapy and/or radiotherapy. Recently, a new treatment has been proposed – Boron Neutron Capture Therapy (BNCT) – which exploits the interaction between Boron-10 atoms (introduced by vector molecules) and low energy neutrons produced by giant accelerators or nuclear reactors.

Methods

The objective of the present study is to compute the deposited dose using a natural source of neutrons (atmospheric neutrons). For this purpose, Monte Carlo computer simulations were carried out to estimate the dosimetric effects of a natural source of neutrons in the matter, to establish if atmospheric neutrons interact with vector molecules containing Boron-10.

Results

The doses produced (an average of 1 μGy in a 1 g tumour) are not sufficient for therapeutic treatment of in situ tumours. However, the non-localised yet specific dosimetric properties of 10B vector molecules could prove interesting for the treatment of micro-metastases or as (neo)adjuvant treatment. On a cellular scale, the deposited dose is approximately 0.5 Gy/neutron impact.

Conclusion

It has been shown that BNCT may be used with a natural source of neutrons, and may potentially be useful for the treatment of micro-metastases. The atmospheric neutron flux is much lower than that utilized during standard NBCT. However the purpose of the proposed study is not to replace the ordinary NBCT but to test if naturally occurring atmospheric neutrons, considered to be an ionizing pollution at the Earth''s surface, can be used in the treatment of a disease such as cancer. To finalize this study, it is necessary to quantify the biological effects of the physically deposited dose, taking into account the characteristics of the incident particles (alpha particle and Lithium atom) and radio-induced effects (by-stander and low dose effect). One of the aims of the presented paper is to propose to experimental teams (which would be interested in studying the phenomena) a simple way to calculate the dose deposition (allometric fit of free path, transmission factor of brain).  相似文献   

10.

Aim

To design the measuring device arrangement of array-type CdTe detector for BNCT-SPECT.

Background

In a boron neutron capture therapy, a very serious unsolved problem exists, namely that the treatment effect for BNCT cannot be known during irradiation in real time. Therefore, we have been developing a so-called BNCT-SPECT with a CdTe detector, which can obtain a three-dimensional image for the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of 7Li nucleus created by the 10B(n,α) reaction. However, no practical uses were realized at present, because BNCT-SPECT requires very severe conditions for spatial resolution, measuring time, statistical accuracy and energy resolution.

Materials and methods

The design study was performed with numerical simulations carried out by a 3-dimenaional transport code, MCNP5 considering the detector assembly, irradiation room and even arrangement of arrayed CdTe crystals.

Results

The estimated count rate of 478 keV gamma-rays was sufficiently large being more than the target value of over 1000 counts/h. However, the S/N ratio did not meet the target of S/N > 1. We confirmed that deterioration of the S/N ratio was caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Theoretical calculations were thereafter carried out to find out whether anti-Compton measurement in an array-type CdTe detector could decrease the noise due to Compton scatterings.

Conclusions

The calculation result showed that the anti-coincidence would possibly increase the S/N ratio. In the next phase, an arrayed detector with two CdTe crystals will be produced to test removal possibility of the anti-coincident event.  相似文献   

11.
Boron neutron capture therapy (BNCT) is based on selective accumulation of 10B carriers in tumor followed by neutron irradiation. We previously proved the therapeutic success of BNCT mediated by the boron compounds boronophenylalanine and sodium decahydrodecaborate (GB-10) in the hamster cheek pouch oral cancer model. Based on the clinical relevance of the boron carrier sodium borocaptate (BSH) and the knowledge that the most effective way to optimize BNCT is to improve tumor boron targeting, the specific aim of this study was to perform biodistribution studies of BSH in the hamster cheek pouch oral cancer model and evaluate the feasibility of BNCT mediated by BSH at nuclear reactor RA-3. The general aim of these studies is to contribute to the knowledge of BNCT radiobiology and optimize BNCT for head and neck cancer. Sodium borocaptate (50 mg 10B/kg) was administered to tumor-bearing hamsters. Groups of 3–5 animals were killed humanely at nine time-points, 3–12 h post-administration. Samples of blood, tumor, precancerous pouch tissue, normal pouch tissue and other clinically relevant normal tissues were processed for boron measurement by optic emission spectroscopy. Tumor boron concentration peaked to therapeutically useful boron concentration values of 24–35 ppm. The boron concentration ratio tumor/normal pouch tissue ranged from 1.1 to 1.8. Pharmacokinetic curves showed that the optimum interval between BSH administration and neutron irradiation was 7–11 h. It is concluded that BNCT mediated by BSH at nuclear reactor RA-3 would be feasible.  相似文献   

12.
Invasive nonfunctional pituitary adenomas (NFPAs) are difficult to completely resect and often develop tumor recurrence after initial surgery. Currently, no medications are clinically effective in the control of NFPA. Although radiation therapy and radiosurgery are useful to prevent tumor regrowth, they are frequently withheld because of severe complications. Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively and maximally damages tumor cells without harming the surrounding normal tissue. Folate receptor (FR)-targeted boron-10 containing carbon nanoparticles is a novel boron delivery agent that can be selectively taken up by FR-expressing cells via FR-mediated endocytosis. In this study, FR-targeted boron-10 containing carbon nanoparticles were selectively taken up by NFPAs cells expressing FR but not other types of non-FR expressing pituitary adenomas. After incubation with boron-10 containing carbon nanoparticles and following irradiation with thermal neutrons, the cell viability of NFPAs was significantly decreased, while apoptotic cells were simultaneously increased. However, cells administered the same dose of FR-targeted boron-10 containing carbon nanoparticles without neutron irradiation or received the same neutron irradiation alone did not show significant decrease in cell viability or increase in apoptotic cells. The expression of Bcl-2 was down-regulated and the expression of Bax was up-regulated in NFPAs after treatment with FR-mediated BNCT. In conclusion, FR-targeted boron-10 containing carbon nanoparticles may be an ideal delivery system of boron to NFPAs cells for BNCT. Furthermore, our study also provides a novel insight into therapeutic strategies for invasive NFPA refractory to conventional therapy, while exploring these new applications of BNCT for tumors, especially benign tumors.  相似文献   

13.
closo-Dodecaborate lipid liposomes were developed as new vehicles for boron delivery system (BDS) of neutron capture therapy. The current approach is unique because the liposome shell itself possesses cytocidal potential in combination with neutron irradiation. The liposomes composed of closo-dodecaborate lipids DSBL and DPBL displayed high cytotoxicity with thermal neutron irradiation. The closo-dodecaborate lipid liposomes were taken up into the cytoplasm by endocytosis without degradation of the liposomes. Boron concentration of 22.7 ppm in tumor was achieved by injection with DSBL-25% PEG liposomes at 20 mg B/kg. Promising BNCT effects were observed in the mice injected with DSBL-25% PEG liposomes: the tumor growth was significantly suppressed after thermal neutron irradiation (1.8 × 1012 neutrons/cm2).  相似文献   

14.
Abstract

The synthesis and encouraging biological findings with boron-containing nucleosides, such as 5-dihydroxyboryl-2′-deoxyuridine, which could be used for boron neutron capture therapy (BNCT) for the treatment of various malignancies, has provided momentum to synthesize several boron containing nucleosides and oligomers. BNCT is based on the property of the non-radioactive boron-10 isotope to capture low energy neutrons, thereby producing a localized cell-destroying nuclear reaction. Thus, irradiation of tumor cells with neutrons, following incorporation of the boronated nucleoside, would result in the destruction of tumor tissue only. Intracellular phosphorylation by nucleoside kinases, and/or incorporation into the cancer cell DNA as a false nucleotide precursor, followed by irradiation by neutrons, would lead primarily to tumor cell death. The synthetic and biological approaches for boronated pyrimidines, nucleosides, and oligonucleotides for BNCT are reviewed.  相似文献   

15.
PurposeCombined PET/CT imaging has been proposed as an integral part of radiotherapy treatment planning (TP). Contrast-enhanced CT (ceCT) images are frequently acquired as part of the PET/CT examination to support target delineation. The aim of this dosimetric planning study was to investigate the error introduced by using a ceCT for intensity modulated radiotherapy (IMRT) TP with Monte Carlo dose calculation for non-small cell lung cancer (NSCLC).Material and methodsNine patients with NSCLC prior to chemo-RT were included in this retrospective study. For each patient non-enhanced, low-dose CT (neCT), ceCT and [18F]-FDG-PET emission data were acquired within a single examination. Manual contouring and TP were performed on the ceCT. An additional set of independent target volumes was auto-segmented in PET images. Dose distributions were recalculated on the neCT. Differences in dosimetric parameters were evaluated.ResultsDose differences in PTV and lungs were small for all patients. The maximum difference in all PTVs when using ceCT images for dose calculation was ?2.1%, whereas the mean difference was less than ?1.7%. Maximum differences in the lungs ranged from ?1.8% to 2.1% (mean: ?0.1%). In four patients an underestimation of the maximum spinal cord dose between 2% and 3.2% was observed, but treatment plans remained clinically acceptable.ConclusionsMonte Carlo based IMRT planning for NSCLC patients using ceCT allows for correct dose calculation. A direct comparison to neCT-based treatment plans revealed only small dose differences. Therefore, ceCT-based TP is clinically safe as long as the maximum acceptable dose to organs at risk is not approached.  相似文献   

16.
Cripto‐1 (CR‐1) is related to the biological behaviour and prognosis of carcinomas. The purpose of this study was to investigate the significance of CR‐1 expression in surgically resected stage I non‐small cell lung cancer (NSCLC). One hundred and forty‐eight patients with completely resected stage I NSCLC and available clinical follow‐up data were assessed. The protein expression of CR‐1 in the tumours was detected by immunohistochemistry. CR‐1 was highly expressed in 64 of 148 tumours. Among patients with high CR‐1 expression, progression‐free survival and overall survival rate were significantly lower than those of patients with low CR‐1 levels (P = .013 and P = .019, respectively). The incidence of distant metastasis in patients with high CR‐1 expression was significantly higher than that of in patients with low CR‐1 expression (57.13% vs 21.43%, P = .001). The results of the multivariate analysis confirmed that a high CR‐1 was a significant factor for poor prognosis. In conclusion, CR‐1 could be a useful prognostic factor in patients with stage I NSCLC, likely as an indicator of the metastatic propensity of the tumour.  相似文献   

17.
Studies that investigate the radiation of human tumour xenografts require an appropriate radiation source and highly standardized conditions during radiation. This work reports on the design of a standardized irradiation device using a commercially available X-ray tube with a custom constructed lead collimator with two circular apertures and an animal bed plate, permitting synchronous irradiation of two animals. Dosimetry and the corresponding methodology for radiotherapy of human non-small cell lung cancer xenograft tumours transplanted to and growing subcutaneously on the right lower limb in a nude rat model were investigated. Procedures and results described herein prove the feasibility of use of the device, which is applicable for any investigation involving irradiation of non-tumorous and tumorous lesions in small animals.  相似文献   

18.
PurposeVentricular tachycardia (VT) is a life-threatening heart disorder. The aim of this preliminary study is to assess the feasibility of stereotactic body radiation therapy (SBRT) photon and proton therapy (PT) plans for the treatment of VT, adopting robust optimization technique for both irradiation techniques.MethodsECG gated CT images (in breath hold) were acquired for one patient. Conventional planning target volume (PTV) and robust optimized plans (25GyE in single fraction) were simulated for both photon (IMRT, 5 and 9 beams) and proton (SFO, 2 beams) plans. Robust optimized plans were obtained both for protons and photons considering in the optimization setup errors (5 mm in the three orthogonal directions), range (±3.5%) and the clinical target volume (CTV) motion due to heartbeat and breath-hold variability.ResultsThe photon robust optimization method, compared to PTV-based plans, showed a reduction in the average dose to the heart by about 25%; robust optimization allowed also reducing the mean dose to the left lung from 3.4. to 2.8 Gy for 9-beams configuration and from 4.1 to 2.9 Gy for 5-beams configuration. Robust optimization with protons, allowed further reducing the OAR doses: average dose to the heart and to the left lung decreased from 7.3 Gy to 5.2 GyE and from 2.9 Gy to 2.2 GyE, respectively.ConclusionsOur study demonstrates the importance of the optimization technique adopted in the treatment planning system for VT treatment. It has been shown that robust optimization can significantly reduce the dose to healthy cardiac tissues and that PT further increases this gain.  相似文献   

19.
Preclinical studies for boron neutron capture therapy (BNCT) using epithermal neutrons are ongoing at several laboratories. The absorbed dose in tumor cells is a function of the thermal neutron flux at depth, the microscopic boron concentration, and the size of the cell. Dosimetry is therefore complicated by the admixture of thermal, epithermal, and fast neutrons, plus gamma rays, and the array of secondary high-linear-energy-transfer particles produced within the patient from neutron interactions. Microdosimetry can be a viable technique for determining absorbed dose and radiation quality. A 2.5-cm-diameter tissue-equivalent gas proportional counter has been built with 50 parts per million (ppm) 10B incorporated into the walls and counting gas to simulate the boron uptake anticipated in tumors. Measurements of lineal energy (y) spectra for BNCT in simulated volumes of 1-10 microns diameter show a dose enhancement factor of 4.3 for 30 ppm boron, and a "y" of 250 keV/microns for the boron capture process. Chamber design plus details of experimental and calculated linear energy spectra will be presented.  相似文献   

20.
The effect of 3-aminobenzamide (3AB) and benzamide (BZ) (inhibitors of poly(ADP-ribose) synthetase) on radiosensitivity was investigated in normal human fibroblasts and three human cell lines established from tumours with varying degrees of clinical radiocurability. The human tumour cell lines selected were: Ewing's sarcoma, a bone tumour usually considered radiocurable with moderate radiation doses; lung adenocarcinoma, a tumour considered radiocurable with high doses of radiotherapy; and osteosarcoma, a very resistant tumour which is rarely controlled by standard doses of radiotherapy. Poly(ADP-ribose) synthetase inhibitors were added to cultures 2 h prior to irradiation and removed 24 h after. Inhibitors were used at doses producing little or no toxicity in cells. In the presence of these inhibitors, a differential radiosensitization was observed. Ewing's sarcoma cells and normal human fibroblasts were sensitized to an equal extent by either 8 mM 3AB or 4 mM BZ. However, no sensitization was observed at these concentrations in the lung adenocarcinoma cells or osteosarcoma cells. The degree of radiosensitization in vitro by 3AB and BZ correlates well with the clinical radiocurability of these tumours in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号