首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system.MethodsA method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images. A TD treatment was simulated on a chest phantom equipped with a breast attachment. MVCT and MV2D images were performed for 7 different shifted positions of the phantom and registered by 10 different operators with the simulation kilovoltage CT images.ResultsCompared to MVCT, MV2D imaging reduces the dose by a factor of up to 45 and the acquisition time by a factor of up to 49. Comparing the registration shift values obtained for the phantom images obtained with MVCT in the coarse mode to those obtained with MV2D, the mean difference is 1.0 ± 1.1 mm, −1.1 mm ± 1.1, and −0.1 ± 2.2 mm, respectively, in the lateral, longitudinal, and vertical directions.ConclusionsWith dual advantages (very fast imaging and a potentially reduced dose to the heart and contralateral organs), MV2D topographic images may be an attractive alternative to MVCT for the localization of breast cancer patients treated with TomoDirect.  相似文献   

2.
PurposeSource to surface distance (SSD) plays a very important role in external beam radiotherapy treatment verification. In this study, a simple technique has been developed to verify the SSD automatically with lasers. The study also suggests a methodology for determining the respiratory signal with lasers.MethodsTwo lasers, red and green are mounted on the collimator head of a Clinac 2300 C/D linac along with a camera to determine the SSD. A software (SSDLas) was developed to estimate the SSD automatically from the images captured by a 12-megapixel camera. To determine the SSD to a patient surface, the external body contour of the central axis transverse computed tomography (CT) cut is imported into the software. Another important aspect in radiotherapy is the generation of respiratory signal. The changes in the lasers separation as the patient breathes are converted to produce a respiratory signal. Multiple frames of laser images were acquired from the camera mounted on the collimator head and each frame was analyzed with SSDLas to generate the respiratory signal.ResultsThe SSD as observed with the ODI on the machine and SSD measured by the SSDlas software was found to be within the tolerance limit. The methodology described for generating the respiratory signals will be useful for the treatment of mobile tumors such as lung, liver, breast, pancreas etc.ConclusionThe technique described for determining the SSD and the generation of respiratory signals using lasers is cost effective and simple to implement.  相似文献   

3.
Patients with schizophrenia show decreased processing speed on neuropsychological testing and decreased white matter integrity as measured by diffusion tensor imaging, two traits shown to be both heritable and genetically associated indicating that there may be genes that influence both traits as well as schizophrenia disease risk. The potassium channel gene family is a reasonable candidate to harbor such a gene given the prominent role potassium channels play in the central nervous system in signal transduction, particularly in myelinated axons. We genotyped members of the large potassium channel gene family focusing on putatively functional single nucleotide polymorphisms (SNPs) in a population of 363 controls, 194 patients with schizophrenia spectrum disorder (SSD) and 28 patients with affective disorders with psychotic features who completed imaging and neuropsychological testing. We then performed three association analyses using three phenotypes – processing speed, whole‐brain white matter fractional anisotropy (FA) and schizophrenia spectrum diagnosis. We extracted SNPs showing an association at a nominal P value of <0.05 with all three phenotypes in the expected direction: decreased processing speed, decreased FA and increased risk of SSD. A single SNP, rs8234, in the 3′ untranslated region of voltage‐gated potassium channel subfamily Q member 1 (KCNQ1) was identified. Rs8234 has been shown to affect KCNQ1 expression levels, and KCNQ1 levels have been shown to affect neuronal action potentials. This exploratory analysis provides preliminary data suggesting that KCNQ1 may contribute to the shared risk for diminished processing speed, diminished white mater integrity and increased risk of schizophrenia.  相似文献   

4.
PurposeThis study evaluates the radiological properties of different 3D printing materials for a range of photon energies, including kV and MV CT imaging and MV radiotherapy beams.MethodsThe CT values of a number of materials were measured on an Aquilion One CT scanner at 80 kVp, 120 kVp and a Tomotherapy Hi Art MVCT imaging beam. Attenuation of the materials in a 6 MV radiotherapy beam was investigated.ResultsPlastic filaments printed with various infill densities have CT values of −743 ± 4, −580 ± 1 and −113 ± 3 in 120 kVp CT images which approximate the CT values of low-density lung, high-density lung and soft tissue respectively. Metal-infused plastic filaments printed with a 90% infill density have CT values of 658 ± 1 and 739 ± 6 in MVCT images which approximate the attenuation of cortical bone. The effective relative electron density REDeff is used to describe the attenuation of a megavoltage treatment beam, taking into account effects relating to the atomic number and mass density of the material. Plastic filaments printed with a 90% infill density have REDeff values of 1.02 ± 0.03 and 0.94 ± 0.02 which approximate the relative electron density RED of soft tissue. Printed resins have REDeff values of 1.11 ± 0.03 and 1.09 ± 0.03 which approximate the RED of bone mineral.Conclusions3D printers can model a variety of body tissues which can be used to create phantoms useful for both imaging and dosimetric studies.  相似文献   

5.
BackgroundThis study aimed to investigate the effect of demographic characteristics and disease stage on the survival outcomes of patients with myoepithelial carcinoma (MECA) of the salivary glands, and to assess the role of radiotherapy in these patients.MethodsThe Epidemiology, Surveillance and End Results database was queried from 2000 to 2018 to identify patients with MECA. Data pertaining to the tumor stage, size, histological grade, and demographic characteristics were analyzed. The relationship between clinicopathological features and overall survival (OS) was assessed using statistical analyses.ResultsIn total, 290 patients (137 men and 153 women) were identified. The parotid gland was the most common tumor location (76.6% patients). Approximately half of the patients had locally advanced tumors, and 14.5 and 6.6% had lymph node and distant organ involvement, respectively. The median OS was 142 months, while the survival rates at 120 months and 180 months were 53% and 39%, respectively. In the cohort, 160 patients (55.2%) underwent surgery alone, while 130 patients (44.8%) underwent surgery combined with radiotherapy. Multivariate Cox analysis revealed that histopathological grade, stage, T3 stage (hazard ratio [HR]: 2.47, P = 0.039), T4 stage (HR: 3.33, P = 0.011), N2 stage (HR: 6.59, P = 0.002), and M1 stage (HR: 2.72, 95%confidence interval [CI]: 1.03–7.19; P = 0.044) were associated with poor prognosis. Radiotherapy (HR: 0.58, P = 0.042) was a favorable factor for OS, and it reduced the mortality risk by 42%.ConclusionsHistological grade, stage, and radiotherapy are independent risk factors for OS. The decision to administer chemotherapy for MECA should be made with caution. Adjuvant radiotherapy is recommended in high-risk patients.  相似文献   

6.
This study investigates the feasibility of exploiting the Čerenkov radiation (CR) present during external beam radiotherapy (EBRT) for significant therapeutic gain, using titanium dioxide (titania) nanoparticles (NPs) delivered via newly designed radiotherapy biomaterials. Using Monte Carlo radiation transport simulations, we calculated the total CR yield inside a tumor volume during EBRT compared to that of the radionuclides. We also considered a novel approach for intratumoral titania delivery using radiotherapy biomaterials (e.g. fiducials) loaded with NPs. The intratumoral distribution/diffusion of titania released from the fiducials was calculated. To confirm the CR induced enhancement in EBRT experimentally, we used 6 MV radiation to irradiate human lung cancer cells with or without titania NPs and performed clonogenic assays. For a radiotherapy biomaterial loaded with 20 μg/g of 2-nm titania NPs, at least 1 μg/g could be delivered throughout a tumor sub-volume of 2-cm diameter after 14 days. This concentration level could inflict substantial damage to cancer cells during EBRT. The Monte Carlo results showed the CR yield by 6 MV radiation was higher than by the radionuclides of interest and hence greater damage might be obtained during EBRT. In vitro study showed significant enhancement with 6 MV radiation and titania NPs. These preliminary findings demonstrate a potential new approach that can be used to take advantage of the CR present during megavoltage EBRT to boost damage to cancer cells. The results provide significant impetus for further experimental studies towards the development of nanoparticle-aided EBRT powered by the Čerenkov effect.  相似文献   

7.
PurposeQuality assurance (QA) is one of the most important issues that should be addressed for intraoperative electron radiotherapy (IOERT), which is not benefiting from image-based treatment planning system. The aim of this study is to evaluate the dosimetric characteristics of Gafchromic EBT2 film for breast IOERT QA procedure.MethodsDue to the fact that some dedicated accelerators are being used for IOERT, dependence of the film response to energy, field size, dose rate and incidence angle of electron beam from the LIAC IOERT accelerator was studied. Then, film response curve to breast IOERT doses was obtained and its accuracy was evaluated and justified through comparison to the results of ionometric dosimetry.ResultsThe results of this study indicated that there are no significant differences between the film responses at different energies of 6, 8, 10 and 12 MeV (P-value = 0.99). Similarly, no field size dependency was found when evaluating the response of the film to different field sizes ranging from 4 to 10 cm (P-value = 0.94). Film response was found to be independent of the dose rate of intraoperative electron beam (P-value = 0.12). Film response variations with changing the beam incidence angle were not significant (P-value > 0.8). Calibration curve at the dose range of 8–24 Gy had an acceptable accuracy. The difference between the results of film dosimetry and ionometric dosimetry was around 5% which was in agreement with the results of dose uncertainty estimation.ConclusionThe EBT2 film was found to be a potentially appropriate tool for breast IOERT verification.  相似文献   

8.
Purpose: Dosimetry of ionizing radiation quantifies the energy deposited by an incident beam to the medium. This study presents the relative response of two types of gel dosimeters describing their differences by estimating radiation chemical yields produced in water radiolysis.Methods: Two types of gel dosimeter were used, namely an acid ferrous ion solution infused with xylenol orange known as Fricke gel and a polymer gel based on acrylamide and N,N’-methylenebis(acrylamide) known as PAGAT. Samples were irradiated using two photon beam energies, one from a conventional X-ray tube operated at 44 kV and the other one from a LINAC operated at 6 MV. The dosimeters were analyzed by optical absorbance and magnetic resonance imaging. Additionally, the linear energy transfer of each beam was calculated using Monte Carlo simulations for further estimation of the radiation chemical yields produced during water radiolysis.Results: Obtained results for both gel dosimeters indicate that their response at 44 kV and 6 MV are different, regardless of the read-out technique. On average, the sensitivity at 44 kV was found to be 65 % of the response at 6 MV. The calculated radiation chemical yields are in agreement with the observed experimental results.Conclusions: The main reason for the difference in the response of the dosimeters may be related to the linear energy transfer of each photon beam, which varies the production of primary chemical species during water radiolysis.  相似文献   

9.
10.
PurposeTo assess the dosimetric impact of a patient positioning device for prone breast radiotherapy and assess the accuracy of a treatment planning system (TPS) in predicting this impact.MethodsBeam attenuation and build-up dose perturbations, quantified by ionization chamber and radiochromic film dosimetry, were evaluated for 3 components of the patient positioning device: the carbon fiber baseplate, the support cushions and the support wedge for the contralateral breast. Dose calculations were performed using the XVMC dose engine implemented in the Monaco TPS. All components were included during planning CT acquisition.ResultsBeam attenuation amounted to 7.57% (6 MV) and 5.33% (15 MV) for beams obliquely intersecting the couchtop–baseplate combination. Beams traversing large sections of the support wedge were attenuated by 12.28% (6 MV) and 9.37% (15 MV). For the support cushion foam, beam attenuation remained limited to 0.11% (6 MV) and 0.08% (15 MV) per centimeter thickness. A substantial loss of dose build-up was detected when irradiating through any of the investigated components. TPS dose calculations accurately predicted beam attenuation by the baseplate and support wedge. A manual density overwrite was needed to model attenuation by the support cushion foam. TPS dose calculations in build-up regions differed considerably from measurements for both open beams and beams traversing the device components.ConclusionsIrradiating through the components of the positioning device resulted in a considerable degradation of skin sparing. Inclusion of the device components in the treatment planning CT allowed to accurately model the most important attenuation effect, but failed to accurately predict build-up doses.  相似文献   

11.

Purpose

Patients with acute myocardial infarction (AMI) and respiratory impairment may be treated with either invasive or non-invasive mechanical ventilation (MV). However, there has been little testing of non-invasive MV in the setting of AMI. Our objective was to evaluate the incidence and associated clinical outcomes of patients with AMI who were treated with non-invasive or invasive MV.

Methods

This was a retrospective observational study in which consecutive patients with AMI (n = 1610) were enrolled. The association between exclusively non-invasive MV, invasive MV and outcomes was assessed by multivariable models.

Results

Mechanical ventilation was used in 293 patients (54% invasive and 46% exclusively non-invasive). In-hospital mortality rates for patients without MV, with exclusively non-invasive MV, and with invasive MV were 4.0%, 8.8%, and 39.5%, respectively (P<0.001). The median lengths of hospital stay were 6 (5.8–6.2), 13 (11.2–4.7), and 28 (18.0–37.9) days, respectively (P<0.001). Exclusively non-invasive MV was not associated with in-hospital death (adjusted HR = 0.90, 95% CI 0.40–1.99, P = 0.79). Invasive MV was strongly associated with a higher risk of in-hospital death (adjusted HR = 3.07, 95% CI 1.79–5.26, P<0.001).

Conclusions

In AMI setting, 18% of the patients required MV. Almost half of these patients were treated with exclusively non-invasive strategies with a favorable prognosis, while patients who needed to be treated invasively had a three-fold increase in the risk of death. Future prospective randomized trials are needed to compare the effectiveness of invasive and non-invasive MV for the initial approach of respiratory failure in AMI patients.  相似文献   

12.
Electron beam dose distribution is dependent on the beam energy and complicated trajectory of particles. Recent treatment planning systems using Monte Carlo calculation algorithm provide accurate dose calculation. However, double check of monitor units (MUs) based on an independent algorithm is still required. In this study, we have demonstrated single equation that reproduces the measured relative output factor (ROF) that can be used for MU calculation for electron radiotherapy. Electron beams generated by an iX (Varian Medical Systems) and a PRIMUS (Siemens) accelerator were investigated. For various energies of electron beams, the ROF at respective dmax were measured using diode detector in a water phantom at SSD of 100 cm. Curve fitting was performed with an exponential generalized equation ROF = α(β – e−γR) including three variables (α, β, γ) as a function of field radius and electron energy. The correlation coefficients between the ROF measured and that calculated by the equation were greater than 0.998. For ROF of Varian electron beams, the average values of all fitting formulas were applied for two of the constants; α and β. The parameter γ showed good agreement with the quadratic approximation as a function of mean energy at surface (E0). The differences between measured and calculated ROF values were within ±3% for beams with cutout radius of ≥1.5 cm for electron beams with energies from 6 MeV to 15 MeV. The proposed formula will be helpful for double-check of MUs, as it requires minimal efforts for MU calculation.  相似文献   

13.
This study investigates the superficial dose from FFF beams in comparison with the conventional flattened ones using a Monte Carlo (MC) method. Published phase-space files which incorporated real geometry of a TrueBeam accelerator were used for the dose calculation in phantom and clinical cases. The photon fluence on the central axis is 3 times that of a flattened beam for a 6 MV FFF beam and 5 times for a 10 MV beam. The mean energy across the field in air at the phantom surface is 0.92–0.95 MeV for the 6 MV FFF beam and 1.18–1.30 MeV for the corresponding flattened beam. At 10 MV, the values are 1.52–1.72 and 2.15–2.87 MeV for the FFF and flattened beams, respectively. The phantom dose at the depth of 1 mm in the 6 MV FFF beam is 6% ± 2.5% (of the maximum dose) higher compared to the flattened beam for a 25 × 25 cm2 field and 14.6% ± 1.9% for the 2 × 2 cm2 field. For the 10 MV beam, the corresponding differences are 3.4% ± 1.5% and 10.7% ± 0.6%. The skin dose difference at selected points on the patient's surface between the plans using FFF and flattened beams in the head-and-neck case was 6.5% ± 2.3% (1SD), and for the breast case it was 6.4% ± 2.3%. The Monte Carlo simulations showed that due to the lower mean energy in the FFF beam, the clinical superficial dose is higher without the flattening filter compared to the flattened beam.  相似文献   

14.

Purpose

To investigate the relationship between various characteristics of a normal population and laser speckle flowgraphy (LSFG) measurements of mean blur rate (MBR) in the optic nerve head (ONH).

Methods

A total of 189 eyes of 189 normal subjects (93 male, 96 female, mean age 45 ± 14 years old, age range: 20–72) without any history of hypertension, hyperlipidemia or diabetes were enrolled. ONH microcirculation was measured with LSFG and overall MBR (MA), vessel-area MBR (MV), and tissue-area MBR (MT) were derived from these measurements. The statistical association of these measurements with characteristics such as sex, age, intraocular pressure (IOP) and systolic blood pressure (SBP) was then determined.

Results

There was a trend towards decreased IOP and MV and increased SBP with age (P = 0.002, P = 0.035, and P = 0.006, respectively). Furthermore, IOP, MV and SBP were correlated with age (r = -0.23, P = 0.011; r = -0.24, P < 0.001; and r = 0.30, P < 0.001, respectively). Separate multiple regression analyses of independent contributing factors revealed that sex and IOP contributed to MA (P < 0.001 and P = 0.002, respectively), sex, IOP, and age contributed to MV (P < 0.001, P = 0.003, and P = 0.024, respectively), while only IOP contributed to MT (P = 0.003).

Conclusion

In a normal population, MBR was affected by IOP in both the large vessel and capillary areas of the ONH, but not by SBP. MV was also affected by age and sex, while MT was stable independent of age or sex.  相似文献   

15.
PurposeTo estimate fetal dose and its components from three-dimensional conformal radiotherapy for several malignancies presented during pregnancy.Materials and methodsFetal dose was measured from radiotherapy for Hodgkin's lymphoma and for tumors in the region of nasopharynx, breast and lung. Anthropomorphic phantoms were used to simulate an average pregnant patient at the first, second and third trimesters of gestation. Thermoluminescent dosemeters (TLD) were employed for fetal dose measurements. Phantom exposures were also performed to estimate fetal dose due to head leakage, scatter from collimators and beam modifiers and scatter generated inside the phantom (Din). All treatments were delivered for 6 MV photon beams.ResultsRadiotherapy of Hodgkin's lymphoma resulted in a fetal dose of 5.6–57.9 cGy depending upon the gestational age and the distance between the fetal level and the field edge. The corresponding dose ranges for treatment of nasopharyngeal, breast and lung cancer was 4.0–17.1 cGy, 3.9–24.8 cGy and 5.7–74.3 cGy, respectively. The Din at the first trimester of gestation was always smaller than 10 cGy for all examined malignancies. Pregnancy progression resulted in Din values above or below 10 cGy depending upon the treatment site and gestational age.ConclusionThis study provides data about the fetal exposure and the contribution of Din to the total fetal dose from conformal radiation therapy. The Din knowledge prior to patient's irradiation enables radiation oncologists and medical physicists to decide whether fetal dose may be limited to 10 cGy or less with or without the introduction of special shielding materials.  相似文献   

16.
BackgroundThe rates and routes of Helicobacter pylori transmission, in a high-prevalent country like Iran, with gastric cancer as the leading cause of male cancer mortality, are of great essence. Here, we have studied the H. pylori-associated risk factors and the likelihood of interspousal transmission.MethodsIn a cohort of 686 young prewed couples, questionnaires were self-administered and serum samples were collected, for assessment of risk factors and H. pylori serostatus, at baseline and follow-up. Of the 475 H. pylori single- or double-seronegative couples, 201 returned for follow-up. The average follow-up duration was 2.2 (SD 0.6) years, with a total of 560.1 person-years. Logistic regression and Cox regression models were used to estimate the odds ratios (ORs) and hazard ratios (HRs).ResultsThe risk of infection was higher in men than women (OR: 1.3, 95% CI: 1.0–1.8) and among metropolitan than rural residents (OR = 1.4, 95% CI: 1.1–1.9). It was also significantly higher among those with three (OR = 1.6, 95% CI: 1.1–2.2), and four or more siblings (OR = 1.4, 95% CI: 1.0–1.9), in reference to those with one or no siblings. Adult H. pylori acquisition occurred in 10.9% (27/247) of the seronegative participants. The risk of the acquisition was significantly associated with age (P value for trend=0,000). It was also significantly lower among participants who had various degrees of education as compared to illiterate subjects (HR = 0.2, 95% CI: 0.1–0.9). Nevertheless, our analysis did not find any evidence for interspousal transmission (HR = 1.0, 95% CI: 0.4–2.2).ConclusionWhilst H. pylori acquisition was detected in the young adult Iranian population, our findings did not support interspousal transmission, as a mode of acquisition.  相似文献   

17.
PurposeTo commission and assess the performance of AlignRT InBore™, a Halcyon™ and Ethos™-dedicated Surface Guided Radiation Therapy (SGRT) platform which combines ceiling-mounted cameras for patient setup and bore-mounted cameras for in-bore tracking.MethodsTo check the potential impact of InBore™ cameras on dose delivery, 16 SRS, H&N, breast and pelvis patients’ quality assurance (QA) treatment plans were measured with/without AlignRT InBore™ and using ArcCHECK® and SRS MapCHECK®. Impact on image quality was determined using Catphan® 540 phantom and considering all available MV and CBCT protocols (head, breast, chest and pelvis). The stability, accuracy and overall performance of AlignRT InBore™ was assessed using an MV Cube and anthropomorphic phantoms.ResultsComparison of 2D dose distributions with/without AlignRT InBore™ showed no impact on treatment delivery for all 16 QA checks (p-value > 0.25). 2D and CBCT images showed no artefacts or change in the contrast-to-noise ratio, resolution and noise values measured with Catphan® 540. Anti-collision sensors were unaffected by the bore-mounted cameras. Additionally, AlignRT InBore™ cameras allowed for motion detection with sub-0.5 mm accuracy and sub-0.4 mm stability with surface coverage of >50 × 60 × 35 cc. Accurate transition (sub-0.3 mm) from virtual to treatment isocentres was achieved. Finally, Halcyon™ rotations during CBCT and beam delivery resulted in limited camera vibrations with translation uncertainty <0.5 mm in left-right and anterior-posterior directions and <0.1 mm in head-feet direction.ConclusionAlignRT InBore™ provides SGRT setup and intrafraction monitoring capabilities with a performance comparable to standard SGRT solutions while having no adverse effect on Halcyon™.  相似文献   

18.
《Endocrine practice》2021,27(3):245-253
ObjectiveTo examine risk factors that might be associated with thyroid eye disease (TED) in patients with Graves’ disease (GD), which may guide physicians in the prevention and management of TED.MethodsMedline and Embase were searched for articles discussing risk factors of TED. Comparisons were made between GD patients with and without TED, and between active and inactive TED GD patients. Weighted mean differences (WMDs) and odds ratios (ORs) were determined for continuous and dichotomous outcomes, respectively. Results were pooled with random effects using the DerSimonian and Laird model.ResultsFifty-six articles were included in the analysis. Smoking, inclusive of current and previous smoking status, was a significant risk factor for TED (OR: 2.401; CI: 1.958-2.945; P < .001). Statistical significance was found upon meta-regression between male sex and the odds of smoking and TED (β = 1.195; SE = 0.436; P = .013). Other risk factors were also examined, and patients with TED were significantly older than those without TED (WMD: 1.350; CI: 0.328-2.372; P = .010). While both age (WMD: 5.546; CI: 3.075-8.017; P < .001) and male sex (OR: 1.819; CI: 1.178-2.808; P = .007) were found to be significant risk factors for active TED patients compared to inactive TED patients, no statistical significance was found for family history, thyroid status, cholesterol levels, or body mass index.ConclusionFactors such as smoking, sex, and age predispose GD patients to TED, and TED patients to active TED. A targeted approach in the management of GD and TED is required to reduce the modifiable risk factor of smoking.  相似文献   

19.
《Endocrine practice》2011,17(6):891-896
Objectiveo characterize endocrine dysfunction in pediatric patients with brain tumors who received proton beam (PB) radiation therapy and to compare those treated with PB radiotherapy only versus combined conventional and PB irradiation.MethodsA retrospective review of medical records of patients ≤ 18 years of age who received PB radiation therapy for a brain tumor between 2000 and 2008 was performed. Variables analyzed included patient demographics, tumor type, therapeutic modalities, radiation doses, and types and timing of endocrine dysfunction.ResultsThirty-eight patients were identified, of whom 31 (19 boys and 12 girls; mean age, 11.9 ± 3.3 years) had undergone endocrine evaluation. Of these patients, 19 received PB radiotherapy only and 12 received conventional plus PB irradiation. Before irradiation, a cranial surgical procedure was performed in 28 study subjects, and 22 received chemotherapy. The mean duration of follow-up after radiation therapy was 1.8 ± 0.8 years. Nine patients (47%) in the PB only group and 4 (33%) in the conventional plus PB group developed endocrine dysfunction (no significant difference) after cranial irradiation. Children with endocrine sequelae treated with PB irradiation alone received fewer cobalt gray equivalents than those treated with conventional plus PB irradiation (5,384 ± 268 versus 5,775 ± 226, respectively; P < .02), and pituitary hormone deficiencies were detected later during follow-up in those who received PB radiotherapy only versus conventional plus PB irradiation (1.17 ± 0.4 years versus 0.33 ± 0.11 year, respectively; P < .01).ConclusionA high rate of endocrine sequelae was seen in our study. Children with brain tumors treated with conventional plus PB irradiation developed endocrine dysfunction faster and received a higher radiation dose than those receiving PB radiotherapy only. Prior surgical treatment and chemotherapy were additional risk factors. Large prospective studies are needed to evaluate further the incidence of endocrine sequelae after PB irradiation in children. (Endocr Pract. 2011;17:891-896)  相似文献   

20.
PurposeThe aim of this work was to extend an in-vivo dosimetry (IVD) method, previously developed by the authors for 3D-conformal radiotherapy, to step and shoot IMRT treatments for pelvic tumors delivered by Elekta linacs.Materials and methodsThe algorithm is based on correlation functions to convert EPID transit signals into in-vivo dose values at the isocenter point, Diso. The EPID images were obtained by the so-called “IMRT Dosimetric Weighting” mode as a superposition of many segment fields. This way each integral dosimetric image could be acquired in about 10 s after the end of beam delivery and could be processed while delivering the successive IMRT beams. A specific algorithm for Diso reconstruction especially featured for step and shoot IMRT was implemented using a fluence inhomogeneity index, FI, introduced to describe the degree of beam modulation with respect to open beams. A γ-analysis of 2D-EPID images obtained day to day, resulted rapid enough to verify the plan delivery reproducibility.ResultsFifty clinical IMRT beams, planned for patients undergoing radiotherapy of pelvic tumors, were used to irradiate a homogeneous phantom. For each beam the agreement between the reconstructed dose, Diso, and the TPS computed dose, Diso,TPS, was well within 5%, while the mean ratio R = Diso/Diso,TPS resulted for 250 tests equal to 1.006 ± 0.036. The same beams were checked in vivo, i.e. during patient treatment delivery, obtaining 500 tests whose average R ratio resulted equal to 1.011 ± 0.042. The γ-analysis of the EPID images with 5% 3 mm criteria supplied 85% of the tests with pass rates γmean ≤ 0.5 and Pγ<1 ≥ 90%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号