The rapid determination of waste-water quality of waste-water treatment plants in terms of pollutional strength, i.e. biochemical oxygen demand (BOD) is difficult or even impossible using the chemical determination method. The present study reports the determination of BOD within minutes using microbial BOD sensors, as compared to the 5-day determination using the conventional method. Multiple criteria establish the basis for the development of a BOD biosensor useful for rapid and reliable BOD estimation in industrial waste-waters. Of these, preparation of a suitable novel immobilized microbial membrane used in conjunction with an apt transducer is discussed. As a result, a microbial biosensor based on a formulated, synergistic, pre-tested microbial consortium has been developed for the measurement of BOD load of various industrial waste-waters. The sensor showed maximum response in terms of current difference, when a cell concentration of 2.25 x 10(10) CFU, harvested in their log phase of growth were utilized for microbial membrane construction. The sensor showed a stability of 180 days when the prepared membranes were stored at a temperature of 4 degrees C in 50 mM phosphate buffer of pH 6.8. The reusability of the immobilized membranes was up to 200 cycles without appreciable loss of their response characteristics. A linear relationship between the current change and a glucose-glutamic acid (GAA) concentration up to 60 mg l(-1) was observed (r=0.999). The lower detection limit was 1.0 mg l(-1) BOD. The sensor response was reproducible within +/-5% of the mean in a series of ten samples having 44 mg l(-1) BOD using standard a GGA solution. When used for the BOD estimation of industrial waste-waters, a relatively good agreement was found between the two methods, i.e. 5-day BOD and that measured by the developed microbial sensor.  相似文献   

2.
The stopped-flow system with an ozonizer was developed to estimate low biochemical oxygen demand (BOD) in rivers. Rivers contain many biopersistent organic compounds such as humic acid, lignin, and gum arabic. Free radicals generated by self-decomposition of ozone were used as powerful oxidants to split organic compounds. Ozonysis of the samples was carried out by 42.4 g N−1 m−3 ozone for 3 min at pH 7.0. Artificial wastewater (AWW) solutions were employed as standard solutions for the calibrations of the BOD sensor. At a BOD of 1 mg l−1, the sensor response after ozonation was 1.6-fold higher than that before ozonation. The response time of the BOD sensor was only 5 min, being independent of the concentrations, and the lower detection limit was 0.5 mg l−1 BOD. The degradations of lignin and tannic acid by ozonation were 54.1 and 42.3%, respectively. In the biosensor responses by ozonation, lignin, gum arabic, and surfactant increased by double or more compared with previous responses. BOD in rivers was estimated using the stopped-flow system. Environmental samples pretreated with ozone gave high responses to the biosensor that were similar to those of the conventional BOD5 method. Accordingly, a good correlation between the sensor and the conventional BOD5 was obtained (r = 0.989). The system has to evolve the highly sensitive BOD determination.  相似文献   

3.
A novel type of biochemical oxygen demand (BOD) biosensor was developed for water monitor, based on co-immobilizing of Trichosporon cutaneum and Bacillus subtilis in the sol-gel derived composite material which is composed of silica and the grafting copolymer of poly (vinyl alcohol) and 4-vinylpyridine (PVA-g-P(4-VP)). Factors that influence the performance of the resulting biosensor were examined. The biodegradable substrate spectrum could be expanded by the co-immobilized microorganisms. The biosensor prepared also exhibited good reproducibility and long-term stability. Good agreement was obtained between the results of the sensor BOD measurement and those obtained from conventional BOD(5) method for water samples.  相似文献   

4.
Liu C  Ma C  Yu D  Jia J  Liu L  Zhang B  Dong S 《Biosensors & bioelectronics》2011,26(5):2074-2079
To improve the practicability of rapid biochemical oxygen demand (BOD) method, we proposed a stable BOD sensor based on immobilizing multi-species BODseed for wastewater monitoring in the flow system. The activation time of the biofilm was greatly shortened for the biofilm prepared by BODseed in the organic-inorganic hybrid material. Some influence factors such as temperature, pH, and concentration of phosphate buffer solution (PBS) were investigated in detail in which high tolerance to environment was validated for the BOD sensor permitted a wide pH and PBS concentration ranges. The minimum detectable BOD was around 0.5 mg/l BOD under the optimized 1.0 mg/ml BODseed immobilized concentration. The as-prepared BOD sensor exhibited excellent stability and reproducibility for different samples. Furthermore, the as-prepared BOD biosensor displayed a notable advantage in indiscriminate biodegradation to different organic compounds and their mixture, similar to the character of conventional BOD(5) results. The results of the BOD sensor method are well agreed with those obtained from conventional BOD(5) method for wastewater samples. The proposed rapid BOD sensor method should be promising in practical application of wastewater monitoring.  相似文献   

5.
A novel design of a biochemical oxygen demand (BOD) biosensor has been developed for on-line monitoring of easily biodegradable organic compounds in aqueous samples. The biological recognition element of the sensor could be easily renewed by injecting new bacterial paste without disassembling the sensor system. The sensor measurements were carried out in the initial-rate mode using a flow injection (FI) system, resulting in 60 s for one sample analysis followed by a recovery time less than 10 min. The sensor performance achieved showed a wide detection linearity over the range of 5-700 mg BOD5.l(-1) and a generally good agreement between the BOD values estimated by the biosensor and the conventional 5-day test. Furthermore, the precision test was in the control range (i.e. repeatability < or = /+/-7.5%/, reproducibility < or = /+/-7.3%/). The sensor could be used over 1 week in continuous test, however, the best performance was found within the first 24 h where standard deviation of the sensor response was +/-2.4%. The design of the sensor allows easy and fast renewal of the cells used as sensing elements. Replacement of biological recognition element and calibration of the sensor responses can be performed in a rather simple procedure on a daily regular basis. By using a mixed culture as the bio-receptor, one gets a sensor that reacts to a wide range of substrates. The new sensor construction will thus allow fast and convenient replacement of the bio-receptor and on-line assay of a broad range of substrates. This makes the sensor being an interesting and promising candidate for on-line monitoring of biological treatment process.  相似文献   

6.
生物传感器快速测定BOD的研究   总被引:13,自引:0,他引:13  
生化需氧量(biochemicaloxygendemand,BOD)是一种表征水体有机污染程度的综合指标,广泛应用于水体监测和废水处理厂的运行控制。由于BOD的标准测定方法需时5天,不能及时地反映水质状况和反馈处理信息,因此快速测定BOD的方法和仪器化研究近年来得到广泛的重视。利用生物传感器测定BOD是一种有效地快速测定废水中可生化降解有机物的方法。介绍生物传感器的工作原理及其生物敏感材料,讨论BOD传感器的性能参数以及BOD快速测定值(BODst)与标准BOD5值的一致性问题。对现阶段市场上常见的几种BOD快速测定仪进行简单的介绍,并对它们的性能进行比较 。  相似文献   

7.
A microbial fuel cell type of biosensor was used to determine the biochemical oxygen demand (BOD) of wastewater. The biosensor gave a good correlation between the BOD value and the coulomb produced. The BOD sensor has been operated for over 5 years in a stable manner without any servicing. This is much longer that that of previously reported BOD biosensors.  相似文献   

8.
We characterized a mediator-type biochemical oxygen demand (BOD) sensor with a three-electrode system using potassium ferricyanide (FC) and Pseudomonas fluorescens in our previous study. In the present study, we have utilized the advantages of a mediator-type biosensor, which does not require air-supply equipment for on-site measurements, and made a fully disposable sensor tip for a portable device. The tip consists of a two-electrode system with P. fluorescens immobilized on a cellulose acetate membrane and is packaged in polyester film to prevent it from drying out. By aeration with a 0.1 M NaCl solution of P. fluorescens (after growth), the sensor responses as well as their reproducibility and stability have been successfully improved. The responses increased more than seven times, and the calibration curve from 15 to 260 mg l(-1) also remained linear although the response decreased approximately half the original after at least 35 days in storage. The reproducibility of the sensor responses improved to 12.7% (average of relative standard deviations (RSDs)) in the calibration curve obtained by using the Organization for Economic Cooperation and Development synthetic sewage. Examination of real samples from three different sources showed that the BOD as determined by the sensor correlates well with the conventional 5-day BOD method (r(2)=0.982, 0.823, and 0.809). Consequently, the aeration process makes it possible to realize rapid, and in situ measurements without the long conditioning process that is generally required to activate the microorganisms immobilized on bio-films before use. Finally, we have designed a portable device that utilizes our disposable sensor tip.  相似文献   

9.
An optical fiber biosensor was developed for the evaluation of low Biochemical Oxygen Demand (BOD) values in river waters. Artificial wastewater (AWW) solution was employed as standards for the calibration of the BOD sensor. The response time of the sensor was 15 min, and the optimal BOD response was observed at 30 degrees C, pH 7.0. A linear relationship was obtained between the output voltage and BOD5 values, and the range of determination was 1-10 mg l(-1) BOD. The sensor response was almost not influenced by chloride ion up to 1000 mg l(-1), and also not affected by heavy metal ions (Fe3+, Cu2+, Mn2+, Cr3+, Zn2+). The BOD of river waters was estimated by using the optical fiber biosensor, and good correlation between the sensor and BOD5 test was obtained (r2 = 0.971).  相似文献   

10.
A method to determine the spectrophotometric biochemical oxygen demand (BOD(sp)) was studied with high sensitivity and reproducibility by employing 2,6-dichlorophenolindophenol (DCIP) as a redox color indicator, the yeast Saccharomyces cerevisiae, and a temperature-controlling system providing a three-consecutive-stir unit. The absorbance of DCIP decreased due to the metabolism of organic substances in aqueous samples by S. cerevisiae. Under optimum conditions, a calibration curve for glucose glutamic acid concentration between 1.1 and 22mg O(2) L(-1) (r=0.988, six points, n=3) was obtained when the incubation mixture was incubated for 10min at 30 degrees C. The reproducibility of the optical responses in the calibration curve was 1.77% (average of relative standard deviations; RSD(av)). Subsequently, the characterization of this method was studied. The optical responses to pure organic substances and the influence of chloride ions, artificial seawater, and heavy metal ions on the sensor response were investigated before use with real samples. Measurements of real samples using river water were performed and compared with those obtained using the BOD(5) method. Finally, stable responses were obtained for 36 days when the yeast cell suspension was stored at 4 degrees C (response reduction, 89%; RSD(av) value for 9 testing days, 8.4%).  相似文献   

11.
Aeromonas hydrophila P69.1 (A. hydrophila) was used to construct a semi-specific biosensor to estimate biochemical oxygen demand (BOD) in high fat and grease content wastewaters. A. hydrophila cells were grown in fat containing medium to induce necessary enzymes for transport and degradation of fatty substances. Universal biosensor based on non-specific Pseudomonas fluorescens P75 (P. fluorescens) was used to conduct comparison experiments. Biosensors were calibrated using OECD synthetic wastewater and steady-state method, subsequently several experiments with synthetic and industrial wastewaters were conducted. A linear range up to 45 mg l(-1) BOD(7) was gained using A. hydrophila biosensor, in comparison to 40 mg l(-1) BOD(7) obtained using P. fluorescens biosensors. The lower limit of detection was 5 mg l(-1) BOD(7). Service life of A. hydrophila and P. fluorescens biosensors were 110 and 115 days, respectively. The response time of the biosensors depended on the BOD(7) of measuring solution and was up to 20 min when analyzing different wastewaters. Both biosensors underestimated BOD in meat industry wastewater from 43% up to 71%, but more accurate results could be obtained with A. hydrophila biosensor. Semi-specific A. hydrophila biosensor was able to measure proportion of fat found in wastewater sample, while other refractory compounds remained undetectable to both biosensors.  相似文献   

12.
A bench scale reactor using a sequencing batch reactor process was used to evaluate the applicability of biosensors for the process optimization of biological carbon and nitrogen removal. A commercial biochemical oxygen demand (BOD) biosensor with a novel microbial membrane was used to determine the duration of each phase by measuring samples in real time in an SBR cycle with filling/anoxic-anaerobic/aerobic/sludge wasting/settling/withdrawal periods. Possible strategies to increase the efficiency for the biological removal of carbon and nitrogen from synthetic wastewater have been developed. The results show that application of a BOD biosensor enables estimation of organic carbon, in real time, allowing the optimization or reduction the SBR cycle time. Some typical consumption patterns for organic carbon in the non-aeration phase of a typical SBR operation were identified. The rate of decrease of BOD measured using a sensor BOD, was the highest in the initial glucose breakdown period and during denitrification. It then slowed down until a 'quiescent period' was observed, which may be considered as the commencement of the aeration period. Monitoring the BOD curve with a BOD biosensor allowed the reduction of the SBR cycle time, which leads to an increase in the removal efficiency. By reducing the cycle time from 8 to 4 h cycle, the removal efficiencies of nitrate, glucose, and phosphorus in a given time interval, were increased to nearly double, while the removal of nitrogen ammonium was increased by one-third.  相似文献   

13.
The microorganisms Trichosporon cutaneum and Bacillus licheniformis were used to develop a microbial biochemical oxygen demand (BOD) sensor. It was found that T. cutaneum gave a greater response to glucose, whereas B. licheniformis gave a better response to glutamic acid. Hence, co-immobilized T. cutaneum and B. licheniformis were used to construct a glucose and glutamic acid sensor with improved sensitivity and dynamic range. A membrane loading of T. cutaneum at 1.1x10(8 )cells ml(-1) cm(-2) and B. licheniformis at 2.2x10(8) cells ml(-1) cm(-2) gave the optimum result: a linear range up to 40 mg BOD l(-1) with a sensitivity of 5.84 nA mg(-1) BOD l. The optimized BOD sensor showed operation stability for 58 intermittent batch measurements, with a standard deviation of 0.0362 and a variance of 0.131 nA. The response time of the co-immobilized microbial BOD sensor was within 5-10 min by steady-state measurement and the detection limit was 0.5 mg BOD l(-1). The BOD sensor was insensitive to pH in the range of pH 6.8-7.2.  相似文献   

14.
A fast estimation of biochemical oxygen demand using microbial sensors   总被引:7,自引:0,他引:7  
Summary Microbial amperometric sensors for biochemical oxygen demand (BOD) determination using Bacillus subtilis or Trichosporon cutaneum cells immobilized in polyvinylalcohol have been developed. These sensors allow BOD measurements with very short response times (15–30s), a level of precision of ±5% and an operation stability of 30 days. A linear range was obtained for a B. subtilis-based sensor up to 20 mg/l BOD and for a T. cutaneum-based sensor up to 100 mg/l BOD using a glucose/glutamic acid standard.  相似文献   

15.
Biochemical oxygen demand (BOD) is a measure of the amount of dissolved oxygen that is required for the biochemical oxidation of the organic compounds in 5 days. New biosensor-based methods have been conducted for a faster determination of BOD. In this study, a mathematical model to evaluate the feasibility of using a BOD sensor, based on disposable alginate-entrapped bacteria, for monitoring BOD in situ was applied. The model considers the influences of alginate bead size and bacterial concentration. The disposable biosensor can be adapted according to specific requirements depending on the organic load contained in the wastewater. Using Klein and Washausen parameter in a Lineweaver–Burk plot, the glucose diffusivity was calculated in 6.4 × 10−10 (m2/s) for beads of 1 mm in diameter and slight diffusion restrictions were observed (n = 0.85). Experimental results showed a correlation (p < 0.05) between the respirometric peak and the standard BOD test. The biosensor response was representative of BOD.  相似文献   

16.
The International Organization for Standardization (ISO) was used to evaluate antibacterial activity by titanium dioxide (TiO(2)) photocatalysis since 2006. We evaluated photocatalytic inactivation of Qβ and T4 bacteriophages induced by low-intensity, long-wavelength ultraviolet A (UVA; 0.1 mW cm(-2) and 0.001 mW cm(-2)) irradiation on a TiO(2)-coated glass plate using the ISO methodology. The results indicated that both bacteriophages were inactivated at 0.001 mW cm(-2) UVA. The intensity of UV light, including long-wavelength light (UVA), is very low in an actual indoor environment. Thus, TiO(2) photocatalysis can be beneficial for inactivating viruses in an indoor environment. Experiments using qPCR and bovine serum albumin degradation assume that viral inactivation is caused by outer viral protein disorder and not by viral RNA reduction by reactive oxygen species produced during TiO(2) photocatalysis. Furthermore, we showed that the ISO methodology for standard testing of antibacterial activity by TiO(2) photocatalysis can be applied to assess antiviral activity.  相似文献   

17.
Titanium dioxide (TiO(2)) under ultraviolet (UV) light produces a strong oxidative effect and may therefore be used as a photocatalytic disinfectant. Although many studies on the photocatalytic inactivation of bacteria have been reported, few studies have addressed virus inactivation. In the present study, we demonstrated the inactivation of influenza virus through TiO(2) photocatalysis using TiO(2) nanoparticles immobilized on a glass plate. The influences of the UV intensity, UV irradiation time and bovine serum albumin (BSA) concentration in the viral suspensions on the inactivation kinetics were investigated. Additionally, we also determined whether the International Organization for Standardization (ISO) methodology for the evaluation of antibacterial activity of TiO(2) photocatalysis could be applied to the evaluation of antiviral activity. The viral titers were dramatically reduced by the photocatalytic reaction. Even with a low intensity of UV-A (0.01 mW cm(-2)), a viral reduction of approximately 4-log(10) was observed within a short irradiation time. The viral inactivation kinetics were associated with the exposure time, the UV intensity and the BSA concentration in virus suspensions. These results show that TiO(2) photocatalysis could be used to inactivate the influenza virus. Furthermore, a minor modification of the ISO test method for anti-bacterial effects of TiO(2) photocatalysis could be useful for the evaluation of antiviral activity.  相似文献   

18.
Studies were made to improve the performance of a microbial fuel cell (MFC) as a biochemical oxygen demand (BOD) sensor. The signal from MFCs decreased in the presence of electron acceptors of higher redox potential such as nitrate and oxygen. The addition of azide and cyanide did not change the signal in the absence of the electron acceptors. The respiratory inhibitors eliminated the inhibitory effects of the electron acceptors on the current generation from MFCs. Similar results were obtained using oligotrophic MFCs fed with an environmental sample that contained nitrate. The use of the respiratory inhibitors is therefore recommended for the accurate BOD measurement of environmental samples containing nitrate and/or oxygen with an MFC-type BOD sensor.  相似文献   

19.
This paper demonstrates the functionality, laboratory testing and field application of a microbial sensor that is capable of monitoring the organic pollution extent of wastewaters both off-line in a laboratory and on-line in a wastewater treatment plant. The biosensor was first developed in the laboratory using synthetic wastewater and then applied to monitor the effluent of the unit. The basic working principle of the biosensor is based on the on-line measurement of CO2 concentration in the off gas produced during carbon compound degradation by microbial respiration activities. CO2 concentration under operation conditions (constant oxygen flow rate, residence time and pH) is closely related to the extent of organic pollution (biochemical oxygen demand, chemical oxygen demand). CO2 monitoring is carried out by an infrared spectrometer, whereas current organic pollution is determined off-line according to the conventional 5-day lasting BOD analysis. Off gas analysis of CO2 concentration strongly correlates with off-line biochemical oxygen demand measurements allowing continuous on-line monitoring of the organic load within a wastewater treatment plant. Thus, real time process control and operation become feasible.  相似文献   

20.
生化需氧量(Biochemical oxygen demand,BOD)微生物传感器是一种快速检测水样中有机污染物含量的设备,固定化微生物是其核心部件之一,对其稳定性、响应时间、使用寿命及实际应用范围等性能有着重要影响。生物膜式BOD传感器较其他类型的BOD微生物传感器具有结构简单、灵敏度高、响应时间短等优点,受到广泛的研究和应用。本文主要针对固定化微生物在生物膜式BOD传感器中的应用情况,概述较典型的微生物固定化方式的原理、特点及应用;总结几类应用较多或具有较好前景的载体材料,并讨论载体特性与传感器性能之间的关系;综述微生物在该领域的应用现状;简要介绍生物膜式BOD传感器的实际应用及商业化现状,比较其与另外几种BOD微生物传感器的优缺点;分析生物膜式BOD传感器中固定化微生物现存的一些问题及其发展趋势。  相似文献   