首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present a method for the analysis of urinary 16(5alpha)-androsten-3alpha-ol together with 5beta-pregnane-3alpha,20alpha-diol and four testosterone metabolites: androsterone (Andro), etiocholanolone (Etio), 5alpha-androstane-3alpha,17beta-diol (5alphaA), 5beta-androstane-3alpha,17beta-diol (5betaA) by means of gas chromatography/combustion/isotopic ratio mass spectrometry (GC/C/IRMS). The within-assay and between-assay precision S.D.s of the investigated steroids were lower than 0.3 and 0.6 per thousand, respectively. A comparative study on a population composed of 20 subjects has shown that the differences of the intra-individual delta(13)C-values for 16(5alpha)-androsten-3alpha-ol and 5beta-pregnane-3alpha,20alpha-diol are less than 0.9 per thousand. Thereafter, the method has been applied in the frame of an excretion study following oral ingestion of 50 mg DHEA initially and oral ingestion of 50mg pregnenolone 48 h later. Our findings show that administration of DHEA does not affect the isotopic ratio values of 16(5alpha)-androsten-3alpha-ol and 5beta-pregnane-3alpha,20alpha-diol, whereas the isotopic ratio values of 5beta-pregnane-3alpha,20alpha-diol vary by more 5 per thousand upon ingestion of pregnenolone. We have observed delta(13)C-value changes lower than 1 per thousand for 16(5alpha)-androsten-3alpha-ol, though pregnenolone is a precursor of the 16-ene steroids. In contrast to 5beta-pregnane-3alpha,20alpha-diol, the 16-ene steroid may be used as an endogenous reference compound when pregnenolone is administered.  相似文献   

2.
The metabolic effect of multiple oral testosterone undecanoate (TU) doses over 4 weeks was assessed in seven voluntary men. The protocol was designed to detect accumulation of the substance by choosing the appropriate spot urines collections time and to study the urinary clearance of the substance after weeks of treatment. Urines were analysed by a new GC/C/isotope ratio mass spectrometry (IRMS) method to establish the delta(13)C-values of testosterone metabolites (androsterone and etiocholanolone) together with an endogenous reference compound (16(5alpha)-androsten-3alpha-ol). The significant differences in inter-individual metabolism following TU intake was illustrated by large variations in delta(13)C-values of both T metabolites (maximum Deltadelta(13)C-values = 5.5 per thousand), as well as by very stable longitudinal T/E profiles and carbon isotopic ratios in the first hours following administration. According to T/E ratios and delta(13)C-values, the washout period after 80 mg TU intake was less than 48 h for all subjects and no accumulation phenomenon was observed upon chronic oral administration.  相似文献   

3.
Isotope ratio monitoring (IRM) mass spectrometry was used to measure the relative abundance of stable isotopes in several samples of adult human hemoglobin expressed in E. coli, yeast, and human blood. The results showed significant differences in the distribution of (15)N and (13)C isotopes among hemoglobin samples produced in these organisms. This indicates that IRM mass spectrometry can be used in forensic protein chemistry to identify the origin of protein expression.  相似文献   

4.
Nandrolone and/or its precursors are included in the World Anti-doping Agency (WADA) list of forbidden substances and methods and as such their use is banned in sport. 19-Norandrosterone (19-NA) the main metabolite of these compounds can also be produced endogenously. The need to establish the origin of 19-NA in human urine samples obliges the antidoping laboratories to use isotope ratio mass spectrometry (IRMS) coupled to gas chromatography (GC/C/IRMS). In this work a simple liquid chromatographic method without any additional derivatization step is proposed, allowing to drastically simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis. The purity of the extracts was verified by parallel analysis by gas chromatography coupled to mass spectrometry with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision of ±0.3‰ and between assay precision of ±0.4‰). The method has been tested with samples obtained after the administration of synthetic 19-norandrostenediol and samples collected during pregnancy where 19-NA is known to be produced endogenously. Twelve drugs and synthetic standards able to produce through metabolism 19-NA have shown to present δ13C values around −29‰ being quite homogeneous (−28.8 ± 1.5; mean ± standard deviation) while endogenously produced 19-NA has shown values comparable to other endogenous produced steroids in the range −21 to −24‰ as already reported. The efficacy of the method was tested on real samples from routine antidoping analyses.  相似文献   

5.
The reaction of demethylation mediated by cytochrome P450 (CYP) leads to the equimolar production of demethylated metabolite and formaldehyde. From a 13C-substrate labeled on a carbon of the methyl moiety, [13C]formaldehyde (H13CHO) is liberated. A highly sensitive and specific assay involving the oxidation of H13CHO to 13CO(2) by a double-enzymatic-step reaction is reported. The 13CO(2) was quantified by the method of reverse isotopic dilution based on gas chromatography-isotope ratio mass spectrometry analysis. The method first involves the limiting step of the CYP-dependent reaction, which is stopped with a mixture of zinc sulfate 5 mM and trichloroacetic acid 100 mM. Then, the transformation of H13CHO to 13CO(2) is performed with the formaldehyde (0.2 unit) and the formate (0.2 unit) dehydrogenase NAD-dependent enzymes. The recovery of 13CO(2) from the incubation mixture was equal to 91.4 +/- 3.0%. The accuracy and the precision of the present method were within 12 and 10%, respectively. The limit of quantification was set to 25 pmol. The performance of the assay was validated on human liver microsomes with five probes: [13C]erythromycin, [1-13C]caffeine, [3-13C]caffeine, [7-13C]caffeine, and [13C(2)]aminopyrine. This method is useful for the rapid determination of N-demethylase activity of human liver microsomes from methyl-13C-substrates.  相似文献   

6.
Pregnenolone (PREG) can potentially be abused by athletes to maintain an equilibration of the steroidal environment after sex steroids administrations. Five men volunteers orally ingested 50 mg PREG to determine optimal urinary markers for detection of this steroid. Our findings show that ingestion of PREG has no significant effects on the testosterone/epitestosterone (T/E) and testosterone/luteinizing hormone (T/LH) ratios, whereas variable changes on the carbon isotopic values of three T metabolites: androsterone, etiocholanolone, 5beta-androstane-3alpha,17beta-diol (5beta-androstanediol) together with 16(5alpha)-androsten-3alpha-ol (androstenol) and 5beta-pregnane-3alpha,20alpha-diol (pregnanediol) have been observed. The difference between the carbon isotopic values (delta13C-values) of androstenol and pregnanediol is potentially the most reliable marker of exogenous PREG administration in males. For all subjects, the differences differ by 3.0 per thousand or more over a period of about 10 h and for both of them the detection window for positivity is extended over 40 h.  相似文献   

7.
Wang J  Wu M  Liu X  Xu Y 《Steroids》2011,76(14):1560-1565
Androstenedione (4-androstene-3,17-dione) is banned by the World Anti-Doping Agency (WADA) as an endogenous steroid. The official method to confirm androstenedione abuse is isotope ratio mass spectrometry (IRMS). According to the guidance published by WADA, atypical steroid profiles are required to trigger IRMS analysis. However, in some situations, steroid profile parameters are not effective enough to suspect the misuse of endogenous steroids. The aim of this study was to investigate the atypical steroid profile induced by androstenedione administration and the detection of androstenedione doping using IRMS. Ingestion of androstenedione resulted in changes in urinary steroid profile, including increased concentrations of androsterone (An), etiocholanolone (Etio), 5α-androstane-3α,17β-diol (5α-diol), and 5β-androstane-3α,17β-diol (5β-diol) in all of the subjects. Nevertheless, the testosterone/epitestosterone (T/E) ratio was elevated only in some of the subjects. The rapid increases in the concentrations of An and Etio, as well as in T/E ratio for some subjects could provide indicators for initiating IRMS analysis only for a short time period, 2-22 h post-administration. However, IRMS could provide positive determinations for up to 55 h post-administration. This study demonstrated that, 5β-diol concentration or Etio/An ratio could be utilized as useful indicators for initiating IRMS analysis during 2-36 h post-administration. Lastly, Etio, with slower clearance, could be more effectively used than An for the confirmation of androstenedione doping using IRMS.  相似文献   

8.
Interassay variation of antibody-based routine tests hampers comparability of measurement results for growth hormone (GH) between different laboratories and decision making in clinical practice. Here it is demonstrated that quantification of GH by isotope dilution mass spectrometry (IDMS) constitutes a way to obtain precise and reliable results that can be referred to in evaluation of performance of commercial test kits. With the IDMS method developed, tryptic cleavage products YSFLQNPQTSLCFSESIPTPSNR (T6) and LEDGSPR (T12) of GH are quantified by liquid chromatography tandem mass spectrometry (LC-MS/MS) using isotopically labeled forms of the peptides as internal standards. The GH cleavage fragments are obtained by whole serum tryptic proteolysis and then extracted from the resulting mixture by semipreparative reversed-phase LC followed by strong cation exchange chromatography. Analysis of blank serum spiked with recombinant 22-kDa GH at different concentration levels would result in a mean recovery of 101.6%, a standard deviation (SD) of 2.5%, a combined uncertainty (uc) of 3.0%, and a limit of quantification (LOQ) of 1.7 μg/L when quantifying T6 as a GH-derived fragment, whereas recovery = 100.7%, SD = 2.4%, uc = 2.5%, and LOQ = 2.7 μg/L were found with T12. The potential to acquisition of reference values is exemplified by application to serum materials used in a recent quality assessment exercise for routine laboratories.  相似文献   

9.
19-Norandrosterone (19-NA) as its glucuronide derivative is the target metabolite in anti-doping testing to reveal an abuse of nandrolone or nandrolone prohormone. To provide further evidence of a doping with these steroids, the sulfoconjugate form of 19-norandrosterone in human urine might be monitored as well. In the present study, the profiling of sulfate and glucuronide derivatives of 19-norandrosterone together with 19-noretiocholanolone (19-NE) were assessed in the spot urines of 8 male subjects, collected after administration of 19-nor-4-androstenedione (100 mg). An LC/MS/MS assay was employed for the direct quantification of sulfoconjugates, whereas a standard GC/MS method was applied for the assessment of glucuroconjugates in urine specimens. Although the 19-NA glucuronide derivative was always the most prominent at the excretion peak, inter-individual variability of the excretion patterns was observed for both conjugate forms of 19-NA and 19-NE. The ratio between the glucuro- and sulfoconjugate derivatives of 19-NA and 19-NE could not discriminate the endogenous versus the exogenous origin of the parent compound. However, after ingestion of 100 mg 19-nor-4-androstenedione, it was observed in the urine specimens that the sulfate conjugates of 19-NA was detectable over a longer period of time with respect to the other metabolites. These findings indicate that more interest shall be given to this type of conjugation to deter a potential doping with norsteroids.  相似文献   

10.
The options available for processing quantitative data from isotope coded affinity tag (ICAT) experiments have mostly been confined to software specific to the instrument of acquisition. However, recent developments with data format conversion have subsequently increased such processing opportunities. In the present study, data sets from ICAT experiments, analysed with liquid chromatography/tandem mass spectrometry (MS/MS), using an Applied Biosystems QSTAR Pulsar quadrupole-TOF mass spectrometer, were processed in triplicate using separate mass spectrometry software packages. The programs Pro ICAT, Spectrum Mill and SEQUEST with XPRESS were employed. Attention was paid towards the extent of common identification and agreement of quantitative results, with additional interest in the flexibility and productivity of these programs. The comparisons were made with data from the analysis of a specifically prepared test mixture, nine proteins at a range of relative concentration ratios from 0.1 to 10 (light to heavy labelled forms), as a known control, and data selected from an ICAT study involving the measurement of cytokine induced protein expression in human lymphoblasts, as an applied example. Dissimilarities were detected in peptide identification that reflected how the associated scoring parameters favoured information from the MS/MS data sets. Accordingly, there were differences in the numbers of peptides and protein identifications, although from these it was apparent that both confirmatory and complementary information was present. In the quantitative results from the three programs, no statistically significant differences were observed.  相似文献   

11.
Field studies analyzing the stable isotope composition of xylem water are providing important information on ecosystem water relations. However, the capacity of stable isotopes to characterize the functioning of plants in their environment has not been fully explored because of methodological constraints on the extent and resolution at which samples could be collected and analysed. Here, we introduce an in situ method offering the potential to continuously monitor the stable isotope composition of tree xylem water via its vapour phase using a commercial laser‐based isotope analyser and compact microporous probes installed into the xylem. Our technique enables efficient high‐frequency measurement with intervals of only a few minutes per sample while eliminating the need for costly and cumbersome destructive collection of plant material and laboratory‐based processing. We present field observations of xylem water hydrogen and oxygen isotope compositions obtained over several days including a labelled irrigation event and compare them against results from concurrent destructive sampling with cryogenic distillation and mass spectrometric analysis. The data demonstrate that temporal changes as well as spatial patterns of integration in xylem water isotope composition can be resolved through direct measurement. The new technique can therefore present a valuable tool to study the hydraulic architecture and water utilization of trees.  相似文献   

12.
The measurement of stable isotope natural abundance variations   总被引:6,自引:2,他引:4  
Precise stable isotope natural abundance analysis of the elements of organic matter, yields a wealth of information for the biologist. Robust sample preparation methodology and analytical instrumentation is necessary to achieve precise results. Basic principles of isotope ratio mass spectrometry (IRMS) are detailed, with particular regard to sample size, gas production and transfer into the IRMS ion source. Gas preparation methods developed to give quantitative yields of pure simple gases from organic and inorganic materials include vacuum line combustion, ampoule combustion and automated elemental analysers used off and on-line. The new technique of GC-C-IRMS, where individual volatile organic compounds are separated by GC, combusted and analysed on-line by IRMS, is also described. The conventional dual batch inlet developed by geochemists for the most precise analysis of stable isotopes, is contrasted with continuous flow-IRMS analysis. The needs of the biological scientist for rapid throughput of small samples are discussed in this context. It is argued that the development of new instrumental approaches will permit many new applications of stable isotope methodology in the biological sciences.  相似文献   

13.
Proteomics technologies are continually advancing, providing opportunities to develop stronger and more robust protein interaction networks (PINs). In part, this is due to the ever-growing number of high-throughput proteomics methods that are available. This review discusses how data-independent acquisition (DIA) and co-fractionation mass spectrometry (CF-MS) can be integrated to enhance interactome mapping abilities. Furthermore, integrating these two techniques can improve data quality and network generation through extended protein coverage, less missing data, and reduced noise. CF-DIA-MS shows promise in expanding our knowledge of interactomes, notably for non-model organisms (NMOs). CF-MS is a valuable technique on its own, but upon the integration of DIA, the potential to develop robust PINs increases, offering a unique approach for researchers to gain an in-depth understanding into the dynamics of numerous biological processes.  相似文献   

14.
A method to determine 18 O kinetic isotope effects (KIEs) in the hydrolysis of GTP that is generally applicable to reactions involving other nucleotide triphosphates is described. Internal competition, where the substrate of the reaction is a mixture of 18 O-labeled and unlabeled nucleotides, is employed, and the change in relative abundance of the two species in the course of the reaction is used to calculate KIE. The nucleotide labeled with 18 O at sites of mechanistic interest also contains 13C at all carbon positions, whereas the 16 O-labeled nucleotide is depleted of 13C. The relative abundance of the labeled and unlabeled substrates or products is reflected in the carbon isotope ratio (13C/12C) in GTP or GDP, which is determined by the use of a liquid chromatography-coupled isotope ratio mass spectrometer (LC-coupled IRMS). The LC is coupled to the IRMS by an Isolink interface. Carbon isotope ratios can be determined with accuracy and precision greater than 0.04% and are consistent over an order of magnitude in sample amount. KIE values for Ras/NF1(333)-catalyzed hydrolysis of [beta18 O3,13C]GTP were determined by change in the isotope ratio of GTP or GDP or the ratio of the isotope ratio of GDP to that of GTP. KIE values computed in the three ways agree within 0.1%, although the method using the ratio of isotope ratios of GDP and GTP gives superior precision (<0.1%). A single KIE measurement can be conducted in 25 min with less than 5 microg nucleotide reaction product.  相似文献   

15.
Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500) nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program.  相似文献   

16.
Strategies employing non-gel based methods for quantitative proteomic profiling such as isotope coded affinity tags coupled with mass spectrometry (ICAT-MS) are gaining attention as alternatives to two-dimensional gel electrophoresis (2-DE). We have conducted a large-scale investigation to determine the degree of reproducibility and depth of proteome coverage of a typical ICAT-MS experiment by measuring protein changes in Escherichia coli treated with triclosan, an inhibitor of fatty acid biosynthesis. The entire ICAT-MS experiment was conducted on four independent occasions where more than 24 000 peptides were quantitated using an ion-trap mass spectrometer. Our results demonstrated that quantitatively, the technique provided good reproducibility (median coefficient of variation of ratios was 18.6%), and on average identified more than 450 unique proteins per experiment. However, the method was strongly biased to detect acidic proteins (pI < 7), under-represented small proteins (<10 kDa) and failed to show clear superiority over 2-DE methods in monitoring hydrophobic proteins from cell lysates.  相似文献   

17.
Two mass spectrometric methods were established for the quantitative analyses of alpha-tocopherol (TH) and its oxidation product alpha-tocopherolquinone (TQ) in human plasma. Both methods make use of isotopically labeled internal standards of different levels of deuteration (d3-TH and d6-TQ). Plasma (100 microl) was saponified in the presence of a mixture of antioxidants, and then TH and TQ were extracted with hexane. With the GC-MS method, the analytes were first converted into O-trimethylsilyl derivatives before analysis in the selective ion monitoring mode. The derivatization procedure led to the quantitative conversion of TQ into the O-trimethylsilyl derivative of tocopherolhydroquinone, giving rise to a more stable molecule with less fragmentation than for TQ. The increased stability of the molecule resulted in an enhanced contribution of the base peak to the total observed ions and therefore an increased sensitivity of the base peak for quantification. With the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, TH and TQ were detected by multiple reaction monitoring after positive electrospray ionization. The GC-MS and LC-MS/MS methods showed nearly the same accuracy (>95%) and the same within-day precisions, with less than 5 and 10% for TH and TQ, respectively. The between-day precision and the limit of quantification for TQ in plasma were better by LC-MS/MS (4%; 3 nM) than by GC-MS (21%; 10 nM). Analysis and method validation were carried out with plasma samples obtained from a male volunteer pre- and postexercise. Both techniques showed that the ratio of TQ/TH was elevated by 35% immediately after exercise and had returned to basal levels when measured 24 h later.  相似文献   

18.
Imaging mass spectrometry (IMS) is two-dimensional mass spectrometry to visualize the spatial distribution of biomolecules, which does not need either separation or purification of target molecules, and enables us to monitor not only the identification of unknown molecules but also the localization of numerous molecules simultaneously. Among the ionization techniques, matrix assisted laser desorption/ionization (MALDI) is one of the most generally used for IMS, which allows the analysis of numerous biomolecules ranging over wide molecular weights. Proper selection and preparation of matrix is essential for successful imaging using IMS. Tandem mass spectrometry, which is referred to MSn, enables the structural analysis of a molecule detected by the first step of IMS. Applications of IMS were initially developed for studying proteins or peptides. At present, however, targets of IMS research have expanded to the imaging of small endogenous metabolites such as lipids, exogenous drug pharmacokinetics, exploring new disease markers, and other new scientific fields. We hope that this new technology will open a new era for biophysics.  相似文献   

19.
This work demonstrates that amino acid analysis based on isotope dilution mass spectrometry (IDMS) can be applied to quantify proteins having different complexities and natures. Five proteins and one decapeptide were selected for the study: C-reactive protein (CRP), beta-2-microglobulin (B2 M), cystatine C (CysC), human serum albumin (HSA), Ara h1, and angiotensin I. The quantification was based on the determination of four amino acids, proline (Pro), isoleucine (Ile), valine (Val), and phenylalanine (Phe) within a working range between 5 and 100 pmol/injection of each amino acid, after 60 min digestion with HCl at 150 °C. The amino acids were selected taking into account their abundance in the protein sequence and to include the more difficult to break peptide bonds. Quantification of the protein amounts calculated from each amino acid is consistent, indicating that the method is working reliably. This consistency points to a complete hydrolysis of the proteins. The trueness of the method was proven when dry mass determination after dialysis was applied to HSA and CRP and the results were compared to those from amino acid analysis. Traceability to SI was assured by extensive characterisation of the amino acid calibrants by nuclear magnetic resonance, neutron activation analysis, and Karl Fischer titration.  相似文献   

20.
Mass spectrometry has emerged as a powerful tool for the analysis of all lipids. Lipidomic analysis of biological systems using various approaches is now possible with a quantitative measurement of hundreds of lipid molecular species. Although availability of reference and internal standards lags behind the field, approaches using stable isotope-labeled derivative tagging permit precise determination of specific phospholipids in an experimental series. The use of reactivity of ozone has enabled assessment of double bond positions in fatty acyl groups even when species remain in complex lipid mixtures. Rapid scanning tandem mass spectrometers are capable of quantitative analysis of hundreds of targeted lipids at high sensitivity in a single on-line chromatographic separation. Imaging mass spectrometry of lipids in tissues has opened new insights into the distribution of lipid molecular species with promising application to study pathophysiological events and diseases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号