首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a novel amperometric glucose biosensor was constructed by alternative self-assembly of positively charged poly(diallydimethylammonium chloride) (PDDA) and negatively charged glucose oxidase (GOx) onto a 3D Nafion network via electrostatic adsorption. The amount of Nafion in the electrode and the number of the (PDDA/GOx)n multilayers were optimized to develop a sensitive and selective glucose biosensor. Under optimal conditions, the glucose biosensor with (PDDA/GOx)5 multilayers exhibited remarkable electrocatalytic activity, capable of detecting glucose with enhanced sensitivity of 9.55 μA/mM cm2 and a commendably low detection limit of 20 μM (S/N = 3). A linear response range of 0.05–7 mM (a linear correlation coefficient of 0.9984, n = 20) was achieved. In addition, the glucose biosensor demonstrated superior selectivity towards glucose over some interferents, such as ascorbic acid (AA) and uric acid (UA), at an optimized detection potential of 0.6 V versus Ag/AgCl reference.  相似文献   

2.
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO(4)(-)-oxidized glucose oxidase (IO(4)(-)-oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers. From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46muAmM(-1)cm(-2) and the detection limit of 8.0muM, with a fast response less than 10s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs.  相似文献   

3.
Nanofibrous glucose electrodes were fabricated by the immobilization of glucose oxidase (GOx) into an electrospun composite membrane consisting of polymethylmethacrylate (PMMA) dispersed with multiwall carbon nanotubes (MWCNTs) wrapped by a cationic polymer (poly(diallyldimethylammonium chloride) (PDDA)) and this nanofibrous electrode (NFE) is abbreviated as PMMA-MWCNT(PDDA)/GOx-NFE. The NFE was characterized for morphology and electroactivity by using electron microscopy and cyclic voltammetry, respectively. Field emission transmission electron microscopy (FETEM) image reveals the dispersion of MWCNT(PDDA) within the matrix of PMMA. Cyclic voltammetry informs that NFE is suitable for performing surface-confined electrochemical reactions. PMMA-MWCNT(PDDA)/GOx-NFE exhibits excellent electrocatalytic activity towards hydrogen peroxide (H(2)O(2)) with a pronounced oxidation current at +100 mV. Glucose is amperometrically detected at +100 mV (vs. Ag/AgCl) in 0.1M phosphate buffer solution (PBS, pH 7). The linear response for glucose detection is in the range of 20 microM to 15 mM with a detection limit of 1 microM and a shorter response time of approximately 4 s. The superior performance of PMMA-MWCNT(PDDA)/GOx-NFE is due to the wrapping of PDDA over MWCNTs that binds GOx through electrostatic interactions. As a result, an effective electron mediation is achieved. A layer of nafion is made over PMMA-MWCNT(PDDA)/GOx-NFE that significantly suppressed the electrochemical interference from ascorbic acid or uric acid. In all, PMMA-MWCNT(PDDA)/GOx-nafion-NFE has exhibited excellent properties for the sensitive determination of glucose like high selectivity, good reproducibility, remarkable stability and without interference from other co-existing electroactive species.  相似文献   

4.
We report for the first time the development of a sensitive and selective glucose biosensor based on the self-assembling of multiwall carbon nanotubes (MWCNTs) dispersed in polyhistidine (Polyhis) and glucose oxidase (GOx) on glassy carbon electrodes (GCE). The supramolecular architecture was characterized by SEM, FT-IR and electrochemical techniques. The optimum multistructure was obtained with five (MWCNT-Polyhis/GOx) bilayers and one layer of Nafion as anti-interferent barrier. The sensitivity at 0.700V was (1.94±0.03) mAM(-1) (r=0.9991), with a linear range between 0.25 and 5.00mM, a detection limit of 2.2μM and a quantification limit of 6.7μM with minimum interference from lactose (1.5%), maltose (5.7%), galactose (1.2%), ascorbic acid (1.0%), and uric acid (3.3%). The biocatalytic layer demonstrated to be highly reproducible since the R.S.D. for 10 successive amperometric calibrations using the same surface was 3.6%. The sensitivity of the biosensor after 15 day storage at 4°C remained at 90% of its original value. The combination of the excellent dispersing properties and polycationic nature of polyhistidine, the stability of the MWCNT-Polyhis dispersion, the electrocatalytic properties of MWCNTs, the biocatalytic specificity of GOx, and the permselective properties of Nafion have allowed building up a sensitive, selective, robust, reproducible and stable glucose amperometric biosensor for the quantification of glucose in milk samples.  相似文献   

5.
The interfacial electron transfer of glucose oxidase (GOx) on a poly(glutamic acid)-modified glassy carbon electrode (PGA/GCE) was investigated. The redox peaks measured for GOx and flavin adenine dinucleotide (FAD) are similar, and the anodic peak of GOx does not increase in the presence of glucose in a mediator-free solution. These indicate that the electroactivity of GOx is not the direct electron transfer (DET) between GOx and PGA/GCE and that the observed electroactivity of GOx is ascribed to free FAD that is released from GOx. However, efficient electron transfer occurred if an appropriate mediator was placed in solution, suggesting that GOx is active. The PGA/GCE-based biosensor showed wide linear response in the range of 0.5–5.5 mM with a low detection limit of 0.12 mM and high sensitivity and selectivity for measuring glucose.  相似文献   

6.
He P  Hu N  Zhou G 《Biomacromolecules》2002,3(1):139-146
Layer-by-layer (PDDA/Hb)(n) films were assembled by alternate adsorption of positively charged poly(diallyldimethylammonium) (PDDA) and negatively charged hemoglobin (Hb) at pH 9.2 from their aqueous solutions on pyrolytic graphite electrodes and other substrates. The assembly process was monitored and confirmed by quartz crystal microbalance (QCM), UV-vis spectroscopy, and cyclic voltammetry (CV). CVs of (PDDA/Hb)(n) films showed a pair of well-defined, nearly reversible peaks at about -0.34 V vs SCE at pH 7.0, characteristic of Hb heme Fe(III)/Fe(II) redox couple. Positions of Soret absorption band and infrared amide II band of Hb in (PDDA/Hb)(8) films suggest that Hb in the films keeps its secondary structure similar to its native state. The electrochemical parameters of (PDDA/Hb)(8) films were estimated by square wave voltammetry, and the thickness of the PDDA/Hb bilayer was estimated by QCM and scanning electron microscopy. Trichloroacetic acid and nitrite (NO(2)(-)) were catalytically reduced at (PDDA/Hb)(8) film electrodes. The electrochemical catalytic reactions of O(2) and H(2)O(2) on (PDDA/Hb)(8) films were also studied.  相似文献   

7.
Gold nanoparticles (AuNPs) with an average diameter of 5nm were assembled on the surface of silver chloride@polyaniline (PANI) core-shell nanocomposites (AgCl@PANI). Attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) suggested that AuNPs were incorporated on AgCl@PANI through coordination bonds instead of electrostatic interaction. The resulting AuNPs-AgCl@PANI hybrid material exhibited good electroactivity at a neutral pH environment. An amperometric glucose biosensor was developed by adsorption of glucose oxidase (GOx) on an AuNPs-AgCl@PANI modified glassy carbon (GC) electrode. AuNPs-AgCl@PANI could provide a biocompatible surface for high enzyme loading. Due to size effect, the AuNPs in the hybrid material could act as a good catalyst for both oxidation and reduction of H(2)O(2). As the measurement of glucose was based on the electrochemical detection of H(2)O(2) generated by enzyme-catalyzed-oxidation of glucose, the biosensor exhibited a super highly sensitive response to the analyte with a detection limit of 4 pM. Moreover, the biosensor showed good reproducibility and operation stability. The effects of some factors, such as temperature and pH value, were also studied.  相似文献   

8.
Deng L  Liu Y  Yang G  Shang L  Wen D  Wang F  Xu Z  Dong S 《Biomacromolecules》2007,8(7):2063-2071
Supramolecular organized multilayers were constructed by multiwalled carbon nanotubes modified with ferrocene-derivatized poly(allylamine) redox polymer and glucose oxidase by electrostatic self-assembly. From the analysis of voltammetric signals and fluorescence results, a linear increment of the coverage of enzyme per bilayer was estimated, which demonstrated that the multilayer is constructed in a spatially ordered manner. The cyclic voltammograms obtained from the indium tin oxide (ITO) electrodes coated by the (Fc-PAH@CNT/GOx)n multilayers revealed that bioelectrocatalytic response is directly correlated to the number of deposited bilayers; that is, the sensitivity is tunable by controlling the number of bilayers associated with ITO electrodes. The incorporation of redox-polymer-functionalized carbon nanotubes (CNT) into enzyme films resulted in a 6-10-fold increase in the glucose electrocatalytic current; the bimolecular rate constant of FADH2 oxidation (wiring efficiency) was increased up to 12-fold. Impedance spectroscopy data have yielded the electron diffusion coefficient (De) of this nanostructure to be over 10(-8) cm2 s(-1), which is typically higher than those systems without CNT by at least a factor of 10, indicating that electron transport in the new supramolecular architecture was enhanced by communication of the redox active site of enzyme, redox polymer, and CNT.  相似文献   

9.
Gold nanotubular electrode ensembles were prepared by using electroless deposition of the metal within the pores of polycarbonate track-etched membranes. Mono-enzyme (GOx) and monolayer/bilayer bienzyme (GOx/HRP) bioelectrodes were prepared by immobilizing the enzymes onto gold nanotubes surfaces modified with mercaptoethylamine. Batch amperometric responses to glucose for the different bioelectrodes were determined and compared. The response of the two geometries (monolayer and bilayer) of the bienzyme electrodes was shown to vary with regard to sensitivity at detection potentials above 0V. On the contrary, at detection potentials below 0V, no noticeable influence of the configuration of the bienzyme on the response intensity was observed. The mono-enzyme (650 microAmM-1 in benzoquinone (BQ) at -0.8 V versus Ag/AgCl) and the two bienzyme bioelectrodes (+/-400 microAmM-1 in hydroquinone (H2Q) at -0.2V versus Ag/AgCl) display remarkable sensitivities compared to a classical GOx-modified gold macroelectrode (13 microAmM-1 in BQ at -0.8 V versus Ag/AgCl). A remarkable feature of the bienzyme electrodes is the possibility to detect glucose at very low applied potentials where the noise level and interferences from other electro-oxidizable compounds are minimal. Another important characteristic of the monolayer bienzyme electrode is the possible existence of a direct electronic communication between HRP and the transducer surface.  相似文献   

10.
Layer-by-layer assembly of glucose oxidase (GOx) with single-wall carbon nanotubes (SWCNTs) is achieved on the electrode surface based on the electrostatic attraction between positively charged GOx in pH 3.8 buffer and negatively charged carboxylic groups of CNTs. The cyclic voltammetry and electrochemical impedance spectroscopy are used to characterize the formation of multilayer films. In deaerated buffer solutions, the cyclic voltammetry of the multilayer films of {GOx/CNT}n shows two pairs of well-behaved redox peaks that are assigned to the redox reactions of CNTs and GOx, respectively, confirming the effective immobilization of GOx on CNTs using the layer-by-layer technique. The redox peak currents of GOx increase linearly with the increased number of layers indicating the uniform growth of GOx in multilayer films. The dependence of the cyclic voltammetric response of GOx in multilayer films on the scan rate and pH is also studied. A linear decrease of the reduction current of oxygen at the {GOx/CNT}-modified electrodes with the addition of glucose suggests that such multilayer films of GOx retain the bioactivity and can be used as reagentless glucose biosensors.  相似文献   

11.
In this study, a novel glucose biosensor was fabricated by reconstitutional immobilization of glucose oxidase (GOx) onto a poly(glycidyl methacrylate-co-vinylferrocene) (poly(GMA-co-VFc)) film coated pencil graphite electrode (PGE). The amperometric current response of poly(GMA-co-VFc)-GOx to glucose is linear in the concentration range between 1 and 16 mM (correlation coefficient of 0.9998) with a detection limit of 2.7 μM (S/N = 3). Experimental parameters were studied in detail and optimized, including the pH and temperature governing the analytical performance of the biosensor. The stability and reusability of the biosensor as well as its kinetic parameters have also been studied.  相似文献   

12.
We constructed a fusion protein (GOx-R5) consisting of R5 (a polypeptide component of silaffin) and glucose oxidase (GOx) that was expressed in Pichia pastoris. Silaffin proteins are responsible for the formation of a silica-based cell matrix of diatoms, and synthetic variants of the R5 protein can perform silicification in vitro[1]. GOx secreted by P. pastoris was self-immobilized (biosilicification) in a pH 5 citric buffer using 0.1 M tetramethoxysilane as a silica source. This self-entrapment property of GOx-R5 was used to immobilize GOx on a graphite rod electrode. An electric cell designed as a biosensor was prepared to monitor the glucose concentrations. The electric cell consisted of an Ag/AgCl reference electrode, a platinum counter electrode, and a working electrode modified with poly(neutral red) (PNR)/GOx/Nafion. Glucose oxidase was immobilized by fused protein on poly(neutral red) and covered by Nafion to protect diffusion to the solution. The morphology of the resulting composite PNR/GOx/Nafion material was analyzed by scanning electron microscopy (SEM). This amperometric transducer was characterized electrochemically using cyclic voltammetry and amperometry in the presence of glucose. An image produced by scanning electron microscopy supported the formation of a PNR/GOx complex and the current was increased to 1.58 μA cm−1 by adding 1 mM glucose at an applied potential of −0.5 V. The current was detected by way of PNR-reduced hydrogen peroxide, a product of the glucose oxidation by GOx. The detection limit was 0.67 mM (S/N = 3). The biosensor containing the graphite rod/PNR/GOx/Nafion detected glucose at various concentrations in mixed samples, which contained interfering molecules. In this study, we report the first expression of R5 fused to glucose oxidase in eukaryotic cells and demonstrate an application of self-entrapped GOx to a glucose biosensor.  相似文献   

13.
A nanobiocomposite film consisted of polypyrrole (PPy), functionalized multiwalled carbon nanotubes (cMWNTs), and glucose oxidase (GOx) were electrochemically synthesized by electrooxidation of 0.1M pyrrole in aqueous solution containing appropriate amounts of cMWNTs and GOx. Potentiostatic growth profiles indicate that the anionic cMWNTs is incorporated within the growing PPy-cMWNTs nanocomposite for maintaining its electrical neutrality. The morphology of the PPy-cMWNTs nanocomposite was characterized by scanning electron microscopy (SEM). The PPy-cMWNTs nanocomposite was deposited homogeneously onto glassy carbon electrode. The amperometric responses vary proportionately to the concentration of hydrogen peroxide at the PPy-cMWNTs nanocomposite modified electrode at an operating potential of 0.7V versus Ag/AgCl (3M). The results indicate that the electroanalytical PPy-cMWNTs-GOx nanobiocomposite film was highly sensitive and suitable for glucose biosensor based on GOx function. The GOx concentration within the PPy-cMWNTs-GOx nanobiocomposite and the film thickness are crucial for the performance of the glucose biosensor. The amperometric responses of the optimized PPy-cMWNTs-GOx glucose biosensor (1.5 mgmL(-1) GOx, 141 mCcm(-2) total charge) displayed a sensitivity of 95 nAmM(-1), a linear range up to 4mM, and a response time of about 8s.  相似文献   

14.
Yin B  Yuan R  Chai Y  Chen S  Cao S  Xu Y  Fu P 《Biotechnology letters》2008,30(2):317-322
A glucose biosensor based on layer-by-layer (LBL) self-assembling of chitosan and glucose oxidase (GOD) on a Prussian blue film was developed. First, Prussian blue was deposited on a cleaned gold electrode then chitosan and GOD were assembled alternately to construct a multilayer film. The resulting amperometric glucose biosensor exhibited a fast response time (within 10 s) and a linear calibration range from 6 μM to 1.6 mM with a detection limit of 3.1 μM glucose (s/n = 3). With the low operating potential, the biosensor showed little interference to the possible interferents, including ascorbic acid, acetaminophen and uric acid, indicating an excellent selectivity.  相似文献   

15.
The performance of an implantable glucose sensor is strongly dependent on the ability of their outer membrane to govern the diffusion of the various participating species. In this contribution, using a series of layer-by-layer (LBL) assembled outer membranes, the role of outwards of H(2)O(2) diffusion through the outer membrane of glucose sensors has been correlated to sensor sensitivity. Glucose sensors with highly permeable humic acids/ferric cations (HAs/Fe(3+)) outer membranes displayed a combination of lower sensitivities and better linearities when compared with sensors coated with lesser permeable outer membranes (namely HAs/poly(diallyldimethylammonium chloride) (PDDA) and poly(styrene sulfonate) (PSS)/PDDA). On the basis of a comprehensive evaluation of the oxygen dependence of these sensors in conjunction with the permeability of H(2)O(2) through these membranes, it was concluded that the outer diffusion of H(2)O(2) is crucial to attain optimized sensor performance. This finding has important implications to the design of various bio-sensing elements employing perm-selective membranes.  相似文献   

16.
A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+Br) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+Br) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+(CF3SO2)2N) and poly(ViEtIm+BF4). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.  相似文献   

17.
We report on an amperometric biosensor that is based on a nanocomposite of carbon nanotubes (CNT), a nano-thin plasma-polymerized film (PPF), and glucose oxidase (GOx) as an enzyme model. A mixture of the GOx and a CNT film is sandwiched with 10-nm-thick acetonitrile PPFs. Under PPF layer was deposited onto a sputtered gold electrode. To facilitate the electrochemical communication between the CNT layer and GOx, CNT was treated with nitrogen or oxygen plasma. The resulting device showed that the oxidizing current response due to enzymatic reaction was 4-16-fold larger than that with only CNT or PPF, showing that the PPF and/or plasma process is an enzyme-friendly platform for designing electrochemical communication from the reaction center of GOx to the electrode via CNTs. The optimized glucose biosensor showed high sensitivity (sensitivity of 42 microA mM(-1)cm(-2), correlation coefficient of 0.992, linear response range of 0.025-2.2 mM, and a detection limit of 6 microM at signal/noise ratio of 3, +0.8 V versus Ag/AgCl), high selectivity (almost no interference by 0.5 mM ascorbic acid) for glucose quantification, and rapid response (<4 s to reach 95% of maximum response). Additionally, the devices showed a small and stable background current (0.35+/-0.013 microA) compared with the glucose response (ca. 10 microA at 10mM glucose) and suitable reproducibility from sample-to-sample (<3%, n=4).  相似文献   

18.
Gu H  Yu Y  Liu X  Ni B  Zhou T  Shi G 《Biosensors & bioelectronics》2012,32(1):118-126
In this work, a novel amperometric biosensor for hydrogen peroxide was fabricated through the layer-by-layer (LBL) self-assembling of amine-terminated ionic liquid (IL-NH(2)), and sulfonic acid (SO(3)(-)) functionalized graphene by covalent bonding. The modification of the two functionalities introduced positive and negative charge onto the surface of graphene respectively, thus facilitating the formation of a multilayer film denoted with {IL-RGO/S-RGO}(n) through electrostatic interaction and further immobilization of glucose oxidase (GOx). The resulting {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor displayed an excellent response to glucose at a potential of -200 mV. Combined with on-line microdialysis system, the glucose biosensor in the on-line system showed good linear range from 10 μM to 500 μM with the detection limit of 3.33 μM (S/N=3). Consequently, the basal level of glucose in the striatum of anesthetic rats was calculated to be 0.376 ± 0.028 mM (mean ± s.d., n=3). The {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor was further applied for in vivo sensing of the glucose level in the striatum when rats received intraperitoneal (i.p.) injection of 30 μL insulin, which resulted in an obvious decrease in the extracellular concentration of glucose within 30 min. The method was proved to be sensitive and reproducible, which enabled its promising application in physiology and pathology.  相似文献   

19.
Chemical sensors utilizing immobilized enzymes and proteins are important for monitoring chemical processes and biological systems. In this study, calcium-cross-linked alginate hydrogel microspheres were fabricated as enzyme carriers by an emulsification technique. Glucose oxidase (GOx) was encapsulated in alginate microspheres using three different methods: physical entrapment (emulsion), chemical conjugation (conjugation), and a combination of physical entrapment and chemical conjugation (emulsion-conjugation). Nano-organized coatings were applied on alginate/GOx microspheres using the layer-by-layer self-assembly technique in order to stabilize the hydrogel/enzyme system under biological environment. The encapsulation of GOx and formation of nanofilm coating on alginate microspheres were verified with FTIR spectral analysis, zeta-potential analysis, and confocal laser scanning microscopy. To compare both the immobilization properties of enzyme encapsulation techniques and the influence of nanofilms with uncoated microspheres, the relationship between enzyme loading, release, and effective GOx activity (enzyme activity per unit protein loading) were studied over a period of four weeks. The results produced four key findings: (1) the emulsion-conjugation technique improved the stability of GOx in alginate microspheres compared to the emulsion technique, reducing the GOx leaching from microsphere from 50% to 17%; (2) the polyelectrolyte nanofilm coatings increased the GOx stability over time, but also reduced the effective GOx activity; (3) the effective GOx activity for the emulsion-conjugation technique (about 3.5 x 10(-)(5) AU microg(-)(1) s(-)(1)) was higher than that for other methods, and did not change significantly over four weeks; and (4) the GOx concentration, when compared after one week for microspheres with three bilayers of poly(allylamine hydrochloride)/sodium poly(styrene sulfonate) ({PAH/PSS}) coating, was highest for the emulsion-conjugation technique. As a result, the comparison of these three techniques showed the emulsion-conjugation technique to be a potentially effective and practical way to fabricate alginate/GOx microspheres for implantable glucose biosensor application.  相似文献   

20.
Boron-doped diamond has drawn much attention in electrochemical sensors. However there are few reports on non-doped diamond because of its weak conductivity. Here, we reported a glucose biosensor based on electrochemical pretreatment of non-doped nanocrystalline diamond (N-NCD) modified gold electrode for the selective detection of glucose. N-NCD was coated on gold electrode and glucose oxidase (GOx) was immobilized onto the surfaces of N-NCD by forming amide linkages between enzyme amine residues and carboxylic acid groups on N-NCD. The anodic pretreatment of N-NCD modified electrode not only promoted the electron transfer rate in the N-NCD thin film, but also resulted in a dramatic improvement in the reduction of the dissolved oxygen. This performance could be used to detect glucose at negative potential through monitoring the current change of oxygen reduction. The biosensor effectively performs a selective electrochemical analysis of glucose in the presence of common interferents, such as ascorbic acid (AA), acetaminophen (AP) and uric acid (UA). A wide linear calibration range from 10 microM to 15 mM and a low detection limit of 5 microM were achieved for the detection of glucose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号