首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to study the distribution of 26 major and trace elements in six tissues from 21 human fetuses aged 16–22 wk. Brain, lung, spleen, kidney, heart, and liver were analyzed following a microwave oven digestion step carried out according to clean techniques designed for ultratrace metal analyses. Precision and accuracy controls were conducted using standard reference material #1577b Bovine Liver. Significant differences among tissues were found for most of the elements. Essential trace elements seem to be increasingly retained as fetal tissues mature and become physiologically functional. The ranges of concentrations measured in fetal tissues at this stage of development are generally lower and much narrower than in adult tissues. The age of the fetus, which is not given in most studies, as well as the different techniques and levels of quality assurance could be responsible for the discrepancies in the trace metal concentrations reported here and in the literature. Intratissue homogeneity was also assessed in five human fetal brains. Frontal, occipital, parietal and temporal lobes, striatum, hippocampus, and thalamus were isolated and analyzed separately. No significant differences were found in the distribution of any of the elements at this stage of development. Because of the relatively narrow ranges of concentrations found for most elements, we believe that the results presented in this study represent the inorganic fingerprint of the main tissues of normal fetuses at midpregnancy for the Greater Montreal area.  相似文献   

2.
As a part of an air-pollution biomonitoring survey, a procedure using inductively coupled plasma-mass spectrometry (ICP-MS) and microwave digestion was developed to achieve a high sample throughput and guarantee the accuracy of the results. This article presents an analytical method to measure 22 trace elements. As, Ba, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Ni, Pb, Rb, Sb, Sr, Th, Tl, U, V, W were analyzed in 563 mosses collected in France. The digestion was performed in polytetrafluoroethylene (PTFE) vessel using the mixture HNO3-H2O2-HF. The data were reprocessed taking into account the drift curve calculated for each element. The detection limits (DL) calculation was based on the standard deviations of the reagent blanks concentrations. The DL varied from one batch to another, because of the heterogeneity of the mosses’ elemental contents. The DL ranged between 0.001 μg/g (Cs, Tl) and 70 μg/g (Fe) and were mainly around 0.01 μg/g (As, Cd, Ce, Co, Hg, La, Mo, Sb, Sr, U, V, W). The detection limits obtained were in agreement with the concentrations observed in the samples, except for Hg and Ni. The reproducibility between duplicates and the analytical precision were near 10%. The procedure was tested with the mosses’ reference materials.  相似文献   

3.
The serum molybdenum (Mo) concentrations in 70 Japanese adults (35 males and 35 females) not receiving any medical care or treatment were determined by inductively coupled plasma-mass spectrometry. Serum Mo concentration in the subjects ranged from <0.1 to 9.11 ng/mL. More than half (55.7%) of the subjects showed values of less than 1 ng/mL and only 6 (8.6%) subjects showed more than 2 ng/mL. The mean+/-SD, geometrical mean (GM), range of GM+/-geometrical SD (GSD) and median value were 1.21+/-1.34, 0.81, 0.30 to 2.16, and 0.90 ng/mL, respectively. Among age, body mass index and several serum biochemical values, activities of aspartate aminotransferase and alanine aminotransferase showed significant associations with serum Mo; 15 subjects suspected of having liver dysfunction showed significantly higher serum Mo than others. We propose a range of 0.10-4.73 ng/mL, estimated as a range of GM+/-2GSD of serum Mo in the remaining 55 subjects without liver dysfunction, as a reference range of serum Mo in Japanese healthy adults.  相似文献   

4.
To investigate the physiological roles or toxicity of trace or toxic elements, multielement analysis of limited quantities of samples in the biological tissues is required. Inductively coupled plasma mass spectrometry (ICP-MS) suits this requirement, but spectral and nonspectral interferences are inevitable. We examined correction methods for the nonspectral interferences by analyzing signals of 21 elements in various concentrations of HNO3 as well as five major elements (Na, K, P, Ca, and Cl). Using internal standards, the interferences caused by the major elements were corrected, but the interferences caused by HNO3 were impossible to correct for elements with high ionization potentials. The analytical results using the standard addition method on 14 elements in standard reference materials and fresh brain tissues confirmed the accuracy of this method. Thus, we concluded that the standard addition method is useful to correct for the nonspectral interferences.  相似文献   

5.
Interest in the biological behavior of a growing number of elements, along with increasing recognition of the importance of interactions among them, demands a versatile and reliable technique for multielement analysis of biological samples. Significant improvements over the sensitivity achieved with conventional inductively coupled plasma (ICP) optical emission spectrometries have been realized with the introduction of quadrupole mass spectrometry (MS) for detection of ions in the plasma. The hybrid technique of ICP-MS promises to be a method of rapid multielement analysis, at detection limits that approach or surpass those of other technologies. However, the application of ICP-MS to analyses of biological interest is truly in its infancy. Here we report the use of ICP-MS for the determination of more than 30 elements of biological interest in a tissue and a biological fluid (rat liver and serum, respectively). Experimental values of the elements serve as a basis for discussion of analytical protocols, performance criteria, and certain problems peculiar to ICP-MS.  相似文献   

6.
Magnetic sector field inductively coupled plasma-mass spectrometry (ICP-MS) was applied to the reliable determination of the 8 essential trace elements cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), selenium (Se), and vanadium (V) as well as the 7 nonessential and toxic elements silver (Ag), aluminum (Al), arsenic (As), gold (Au), platinum (Pt), scandium (Sc), and titanum (Ti) in 27 transitory and mature human milk samples and in 4 selected infant formulas. This advanced instrumentation can separate spectral overlaps from the analyte signal hampering significantly the determination of many trace elements by conventional ICP-MS. Moreover, superior detection limits in the picogram per liter range can be obtained with such magnetic sector field instruments. Therefore, this is the first study to report the concentrations of the elements Ag, Au, Pt, Sc, Ti, and V in human milk and in infant formulas. Concentrations of Ag (median: 0.41 μg/L; range: <0.13–42 μg/L) and Au (median: 0.29 μg/L; range 0.10–2.06 μg/L) showed large variations in human milk that might be associated with dental fillings and jewelry. Pt concentrations were very low with most of the samples below the method detection limit of 0.01 μg/L. Human milk concentrations of Co (median: 0.19 μg/L), Fe (380 μg/L), Mn (6.3 μg/L), Ni (0.79 μg/L), and Se (17 μg/L) were at the low end of the corresponding reference ranges. Concentrations of Cr (24.3 μg/L) in human milk were five times higher than the high end of the reference range. For Al (67 μg/L), As (6.7 μg/L), and V (0.18 μg/L), most of the samples had concentrations well within the reference ranges. All elemental concentrations in infant formulas (except for Cr) were approximately one order of magnitude higher than in human milk.  相似文献   

7.
A flow injection-inductively coupled plasma-mass spectrometry (FI-ICP-MS) with a simple sample preparation procedure was developed for the determination of selenium, copper, and zinc in blood serum/plasma. A serum/plasma sample was filtered through a 0.45-μm membrane filter and diluted with a mixture of trace elements in a standard solution (9∶1, v/v). Measurement of the reference serum sample confirmed the accuracy of our method for selenium, copper, and zinc concentration. In the case of blood plasma samples obtained from six healthy adult males, the selenium, copper, and zinc concentrations were similar to those of a typical healthy male in Japan. These results suggest that the sample prepartive procedure coupled with FI-ICP-MS can be used for the routine determination of selenium, copper, and zinc in human blood serum/plasma.  相似文献   

8.
Imbalance in trace metal metabolism may lead to metal interactions that may be of patho-physiological importance. Knowledge of the relation between trace metals in normal tissues is needed to assess abnormal deviations associated with disease. In this study correlations between Cu, Co, Cr, Fe, Mn, Ni, Se, Zn, Al, Ba, Cd, Pb and Sr within the same and between 6 different, normal autopsy tissues were determined using Spearman rank correlation analysis based on analytical data obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES). Fe-Co were correlated in most tissues. Cu-Mn, Zn-Cu, Zn-Mn and Zn-Cd were highly correlated in the kidney medulla. Ni-Ni, Sr-Sr and Cd-Cd were correlated between several tissues, while Fe-Fe, Zn-Zn and Cu-Cu were correlated between kidney cortex and medulla. Mn-Mn was highly correlated between the liver and brain front lobe, cerebellum and heart. High correlations were found for Ni-Co and for Se-Mn between the kidney cortex and brain front lobe and pancreas respectively. Inverse correlations were found for Se-Cd between kidney cortex and cerebellum, for Se-Cd and Cd-Zn between kidney medulla and heart, for Co-Sr and Fe-Sr between the liver and kidney cortex and heart respectively, and for Sr-Mn between kidney medulla and pancreas. A large number of trace elements are statistically correlated within and between different, normal tissues. Knowledge of these correlations may contribute to increase the understanding of kinetic interactions of trace metals in the body and the role of such interactions in normal and disturbed trace metal metabolism.  相似文献   

9.
The analysis of trace elements in biological samples will extend our understanding of the impact that environmental exposure to these elements has on human health. Measuring arsenic content in nails has proven useful in studies evaluating the chronic body burden of arsenic. In this study, we developed methodology with inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of total arsenic in nails. We assessed the utility of the washing procedures for removing surface contamination. Four types of preanalysis treatments (water bath, sonication, water bath plus sonication, and control) after sample decomposition by nitric acid were compared to evaluate the digestion efficiencies. In addition, we studied the stability of the solution over 1 wk and the effect of acidity on the arsenic signal. Arsenic content in the digested solution was analyzed by using Ar-N2 plasma with Te as the internal standard. The results suggest that washing once with 1% Triton Χ-100 for 20 min for cleaning nail samples prior to ICP-MS analysis is satisfactory. Repeated measurement analysis of variance revealed that there was no significant difference among the various sample preparation techniques. Moreover, the measurements were reproducible within 1 wk, and acidity seemed to have no substantial influence on the arsenic signal. A limit of detection (on the basis of three times the standard deviation of the blank measurement) of 7 ng As/g toenail was achieved with this system, and arsenic recoveries from reference materials (human hair and nails) were in good agreement (95–106% recovery) with the certified/reference values of the standard reference materials. ICP-MS offers high accuracy and precision, as well as highthroughput capacity in the analysis of total arsenic in nail samples.  相似文献   

10.
Inductively coupled plasma-mass spectrometry (ICP-MS) is a powerful tool for both quantitative multielement analyses of inorganic elements and measurement of isotope ratios (IRs). The main disadvantage of this technique is the existence of polyatomic isobaric interferences at some key masses. Zinc has been investigated for such potential interferences in serum or plasma. The Zn isotopes,66Zn and68Zn, have no apparent interferences, but32S16O2 and32S2 are isobaric with64Zn. The possible effects of S and other major components of blood plasma—Na, K, Cl, P, Ca—on Zn IRs were investigated using a series of mineral solutions which simulated human plasma with respect to these elements. The mixture of all mineral elements interfered only with64Zn (6.66 ng/mL) and70Zn (8.51 ng/mL). Interferences to66Zn,67Zn, and68Zn were minimal containing 0.90, 0.94, and 0.39 ng/mL, respectively. The copresence of Na or S shifted35Cl16O2 (atomic mass 67 coming from Cl solution) to35Cl2 which reduced the contribution to67Zn. The hypothesis that Zn IRs obtained from plasma at various intervals after the intravenous administration of enriched67Zn to humans would reflect those obtained after extraction of Zn was therefore tested. To compare the two pretreatment methods, “extraction” versus “nonextraction,” specimens were collected from 10 human subjects at intervals of 5 min to 24 h postinjection, and in 4 subjects from 5 min to 9 d postinjection. Two separate aliquots of plasma from each time-point were dried and digested with hydrogen peroxide, and the residue dissolved in nitric acid. One specimen was subjected to zinc extraction using ammonium diethyldithiocarbamate chelate followed by back extraction into nitric acid. The matching aliquot received no further pretreatment. The normalized IRs obtained from67Zn/66Zn and67Zn/68Zn in both the “extracted” and “nonextracted” samples agreed well(r 2 = 0.976 andr 2 = 0.985, respectively) compared to those from other ratios (r 2 = 0.838 for67Zn/64Zn andr 2 = 0.747 for67Zn/70Zn). Considering the minimum possibility of isobaric interferences in plasma samples,67Zn/68Zn obtained from “nonextracted” samples is sufficient for routine Zn kinetic analysis by ICP-MS.  相似文献   

11.
 Proteins are separated by size exclusion chromatography while atomic ions from the inorganic elements are detected on-line by inductively coupled plasma-mass spectrometry. A double focusing mass analyzer provides very high sensitivity, low background, and sufficient spectral resolution to separate the atomic ions of interest from most polyatomic ions at the same nominal m/z value. The chromatograms show the distribution of the elements of interest between protein-bound and free fractions and provide the approximate molecular weights of those protein fractions that contain the elements monitored. The distribution of various elements, including V, Mo, Fe, Co, Mn, and lanthanides, in human or bovine serum samples are shown. Alkali metals and Tl are present primarily as free metal ions and are not bound to proteins. Inorganic elements spiked into the serum samples can be followed into various proteins. EDTA does not remove Fe, Pb, Sn, or Th from the proteins but does extract Mn from some proteins. Procedures for determining the effects of breaking disulfide linkages on the metal binding characteristics of proteins are also described. Received: 22 March 1999 / Accepted: 16 June 1999  相似文献   

12.
A technique for the rapid and accurate estimation of nonheme iron using inductively coupled plasma-atomic emission spectrometry is described. Yttrium was used as an internal standard. An external calibration method was used. The standards were prepared in a matrix composed of 2.5N HCl in 10% (w/v) trichloroacetic acid. The supernatant and coagulum fractions of liver nonheme iron were separated by the method of Drysdale and Ramsay with minor modification. The data determined by this procedure was compared and found to be agreement with data determined by the method of Hallgren. To evaluate the iron status of rats, hemoglobin and liver nonheme iron were determined. Hemoglobin and all of the nonheme iron fractions of the rats fed an iron-deficient diet were significantly lower than those of the rats fed an iron-sufficient diet. The blood content in the liver was estimated to be 80 microL/g from the blood iron concentration, and the difference between total and nonheme iron concentration in liver.  相似文献   

13.
Methods have been developed for the analyses of trace metals in various areas of porcine brains, (temporal, parietal, frontal cortex, both right and left hemispheres). Determinations were carried out using inductively coupled plasma-mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (ETAAS). The elements investigated were Li, Mn, Cu, Zn, Cd, Hg, and Pb by ICP-MS and Cu, Cd, and Mn by ETAAS. For determination by ICP-MS, a method of standard additions calibration coupled with internal standards was used, and for ETAAS, standard additions calibrations were prepared. The accuracy of all methods was determined using NIST and IAEA certified reference material. A small number of pig brains were analyzed by instrumental neutron activation analysis for Cr, Co, Cs, Fe, Rb, Se, Sc, Sb, and Zn using the comparator method of analysis. Four separate NIST standard reference materials have been used to examine the validity of the comparator method.  相似文献   

14.
The distribution of silver, arsenic, cadmium, cobalt, chromium, copper, iron, manganese, nickel, lead, selenium and zinc binding to species with different molecular weight in aqueous extract of krill was studied by on-line size-exclusion chromatography (SEC)/inductively coupled plasma mass spectrometry (ICP-MS). The extract was fractionated in three fractions with different molecular weight (MW) ranges (>20,000 relative molecular mass (rel. mol. mass), 2000-20,000 rel. mol. mass and <2000 rel. mol. mass), which were further analyzed by SEC with columns having different optimum fractionation ranges in order to obtain more detailed information about the MW distribution of the elements. Various distribution profiles for the target elements among different MW ranges were observed. The results obtained indicated that manganese, zinc, silver, cadmium and lead species were mostly distributed in the higher MW range (>20,000 rel. mol. mass). In the case of chromium, iron, cobalt, arsenic and selenium, most of them bind to species with lower MW (<2000 rel. mol. mass). Only copper and nickel species was predominantly present in middle MW range (2000-20,000 rel. mol. mass). Further speciation of arsenic compounds in the small MW fraction was carried out with anion exchange chromatography (AEC) coupled with ICP-MS. The results showed that the dominant arsenic species in this fraction is As(III) (63% of extractable arsenic), while As(V) (13%) and two unknown arsenic species (19% and 5%, respectively) are present in lower amounts.  相似文献   

15.
An analytical method using double focusing sector field inductively — coupled plasma mass spectrometry (sector field ICPMS) for rapid simultaneous determination of 42 elements in urine is described. Sample preparation consisted of 20-fold dilution with 0.14 mol/l nitric acid in ultrapure water. The importance of controlling possible contamination sources at different sample preparation and analysis stages in order to achieve adequate method detection limits (DL) is emphasized. Correction for matrix effects was made using indium and lutetium as internal standards. Different approaches for accuracy assessment in urine analysis are evaluated. Additional information on trace element concentrations in a urine reference material is given. Between-batch precision was assessed from the analysis of separately prepared aliquots of the reference material and was better than 10% RSD for 32 of the elements. The robustness of the procedure was tested by analysis of about 250 samples in one analytical run lasting more than 50 hours. A statistical summary of results for 19 urine samples from non-exposed subjects is presented. For a majority of the elements tested concentrations were higher than the detection limit of the method.  相似文献   

16.
The coupling of the techniques, high-performance liquid chromatography (HPLC), orthogonal acceleration time-of-flight mass spectrometry (OATOF-MS) and inductively coupled plasma mass spectrometry (ICP-MS) provides a very powerful method for identifying and quantifying the products of bradykinin metabolism. In this study, we were able to identify the major metabolites of bradykinin degradation reported in the literature. In addition, a new bradykinin metabolite corresponding to bradykinin 5,9 fragment (BK-(5,9)-fragment) was identified as a product of neutral endopeptidase (NEP) activity. This finding establishes that NEP cleaves bradykinin simultaneously at the positions 4-5 and 7-8. We also demonstrate the equivalent participation of NEP and angiotensin-converting enzyme (ACE) within the rat lung tissue membranes (RLTM) in bradykinin degradation, suggesting its suitability as a model for the assay of dual ACE/NEP inhibitors. On the contrary, in rat kidney brush border membranes (KBBM), ACE is not significantly involved in bradykinin metabolism, with NEP being the major enzyme.  相似文献   

17.
Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) has been developed as a new strategy for detection and imaging of β-amyloid protein in immunohistochemical sections from the brains of a transgenic mouse model of Alzheimer’s disease. The distribution of β-amyloid deposits in tissue was based on measurement of Eu- and Ni-coupled antibodies. The laser-based methodologies (spot ablation, single line raster, and two-dimensional imaging) were also used to detect and map trace element distributions and thus provide a novel probe for both elemental and protein data. We also report the combination of laser capture microdissection with LA-ICP-MS as an alternative strategy for microanalysis of immunohistochemical sections.  相似文献   

18.
Cell culture media metal content is critical in mammalian cell growth and monoclonal antibody productivity. The variability in metal concentrations has multiple sources of origin. As such, there is a need to analyze media before, during, and after production. Furthermore, it is not the simple presence of a given metal that can impact processes, but also their chemical form that is, speciation. To a first approximation, it is instructive to simply and quickly ascertain if the metals exist as inorganic (free metal) ions or are part of an organometallic complex (ligated). Here we present a simple workflow involving the capture of ligated metals on a fiber stationary phase with passage of the free ions to an inductively coupled plasma optical emission spectrometry for quantification; the captured species are subsequently eluted for quantification. This first level of speciation (free vs. ligated) can be informative towards sources of contaminant metal species and means to assess bioreactor processes.  相似文献   

19.
Inductively coupled plasma atomic emission spectroscopy (ICP-AES) was used for analyzing the new cholesterol-based compounds (BCH, BCH-Da, BCH-Db and BCH-Dc) in liposomal formulations. Not only the boron compounds but also the phospholipid compositions of the liposome formulation were quantitatively analyzed. Reasonable limit of detection for boron (0.5?µg/ml) and phosphorous (0.09?µg/ml), respectively, was observed. ICP-MS was also utilized for analyzing BCH in a brain distribution study. The detection limit of boron analysis by ICP-MS is at least three orders of magnitude lower than of that of ICP-AES (1?ng B/ml). The method was linear in the range of 500-1?ng B/ml and the linearity correlation coefficient was 1. In addition, an ultracentrifugation method was developed to separate liposomes from low-density lipoprotein (LDL). Factors such as density gradient and size of liposomes were adjusted to optimize separation and it was observed that in conjunction to time, speed and density gradient, size of the liposome also had impact on the separation using centrifugation method. These findings show the importance of ICP-AES as an analytical method for the analysis of element-based compounds encapsulated in phospholipid vesicles.  相似文献   

20.
The determination of trace and ultratrace elements in human serum by ICP-MS is described. The accuracy of the method is tested using a “second generation” human serum reference material. Elements determined include Fe, Co, Cu, Zn, Br, Rb, Sr, Mo, and Cs. The method is compared to nuclear analytical methods (NAA, PIXE). Perspectives for the future are also discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号