首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Both heavily calcified and ostial lesions are difficult to deal with by percutaneous transluminal coronary angioplasty (PTCA) alone. Acute results are often sub-optimal, complications are more frequent, and long-term results are disappointing. Optimal stent deployment may not be possible unless satisfactory lesion dilatation is achieved and the lesion made more compliant. The use of rotational atherectomy and cutting balloon angioplasty to a calcified ostial lesion in the left circumflex coronary artery prior to stent implantation is reported.  相似文献   

2.
The present study illustrates a possible methodology to investigate drug elution from an expanded coronary stent. Models based on finite element method have been built including the presence of the atherosclerotic plaque, the artery and the coronary stent. These models take into account the mechanical effects of the stent expansion as well as the effect of drug transport from the expanded stent into the arterial wall. Results allow to quantify the stress field in the vascular wall, the tissue prolapse within the stent struts, as well as the drug concentration at any location and time inside the arterial wall, together with several related quantities as the drug dose and the drug residence times.  相似文献   

3.
The present study illustrates a possible methodology to investigate drug elution from an expanded coronary stent. Models based on finite element method have been built including the presence of the atherosclerotic plaque, the artery and the coronary stent. These models take into account the mechanical effects of the stent expansion as well as the effect of drug transport from the expanded stent into the arterial wall. Results allow to quantify the stress field in the vascular wall, the tissue prolapse within the stent struts, as well as the drug concentration at any location and time inside the arterial wall, together with several related quantities as the drug dose and the drug residence times.  相似文献   

4.
The Cutting Balloon consists of a standard balloon dilatation catheter with four microtome-sharp blades that incise the plaque and minimize arterial wall trauma. It was used in 31 patients; nine had calcified arteries, ten had non-compliant lesions, three had in-stent restenosis and nine had aorto-ostial lesions. Seventeen lesions were predilated, 28 were post-dilated and 18 required stent implantation. The procedure was very effective in aorto-ostial lesions, non-compliant lesions that were not responsive to high-pressure balloon dilatation, and was partially successful in calcified arteries. It has a very specific niche in selected lesions.  相似文献   

5.
Based on the currently available data, the strategy of routine stent placement in unselected lesions located in small coronary arteries provides good immediate results but is still associated with a high incidence of in-stent restenosis. Randomized trials comparing elective stenting with balloon angioplasty have not provided the demonstration that routine stenting is the best strategy for percutaneous intervention in coronary arteries with a reference diameter smaller than 2.75-3.0 mm. This paper describes the rationale for provisional stenting in this clinical setting and reviews the role of quantitative coronary angiography, intracoronary ultrasound and intracoronary Doppler measurements in the identification of lesions that would benefit from adjunctive stent placement after balloon angioplasty and in guiding stent implantation.  相似文献   

6.
BACKGROUND: Coronary stents have been used with increasing frequency and in increasingly complex coronary lesions for the treatment of symptomatic coronary artery disease. A new stainless steel coronary stent, the R Stent, has been designed to provide maximum flexibility for tracking and high radial strength post-deployment. AIMS: To assess the safety and feasibility of the R Stent in patients with coronary artery disease. Specific objectives were to assess the R Stent's deployment success, angiographic and procedural success (< 20% residual stenosis and TIMI 3 flow), safety (absence of complications), 30-day and six-month clinical follow-up. METHODS: Between April 1998 and January 1999, stent deployment was attempted in 36 lesions in 30 patients with stable (43%) or unstable (57%) angina pectoris and 29/36 of the lesions were anatomically complex. Treated lesions were in the LAD (n = 15), RCA (n = 13) or LCX (n = 8). RESULTS: Stent deployment was achieved in 97% with one crossing failure in a patient with a long, calcified, proximal LAD lesion. After the procedure, patients were scheduled for one- and six-month clinical follow-up. One patient experienced a non-Q-wave myocardial infarction in hospital. At one month, there were no additional complications. Only one patient experienced recurrence of angina (CCS class 2) within the 30 days. At six-month follow-up, one sudden death had occurred. Three (10%) patients had anginal complaints, one of them received target lesion repeat PTCA. All other patients (87%) were event- and angina-free. CONCLUSION: This first clinical experience with the R Stent shows acceptable feasibility and safety with good long-term clinical results.  相似文献   

7.
重叠支架置入术是临床上用来治疗冠状动脉弥漫性长病变的常用方法,以往曾采取重叠裸金属支架置入术,但其临床预后不佳,目前较为常用的重叠药物洗脱支架置入术被认为相对安全、有效,但仍存在许多潜在问题。本文介绍了适合使用重叠支架置入术进行治疗的冠状动脉病变的特点,回顾了重叠裸金属支架的临床应用情况,阐述了近年来药物洗脱支架的发展以及重叠药物洗脱支架置入术的优势,比较了四种负载不同药物的药物洗脱支架同种重叠置入后的临床疗效,观察了异种药物洗脱支架混合重叠置入后的临床特点和支架重叠段对临床预后的影响,分析了重叠支架置入术与几种其它治疗冠状动脉弥漫性长病变方法的应用区别,并对新一代药物支架的重叠应用进行了展望。  相似文献   

8.
BACKGROUND: Percutaneous Coronary Intervention (PCI) of coronary bifurcation lesion is technically quite demanding. It has been associated with a lower procedural success, higher rates of complication and restenosis. Side-branch occlusion and plaque shifting or 'snow plow' effect are not uncommon. Stenting of the main vessel may cause 'stent jail' of the side-branch. Modern stent design may allow passage of a balloon or stent into the side-branch through the struts of the stent placed in the main vessel. A newly developed 316 stainless steel tubular stent, the Rtrade mark stent is uniquely designed to provide flexibility, radial strength on deployment and conformability. Its large cell size facilitates PCI of bifurcation lesion. AIM: To assess the feasibility of R(trade mark) stent in the treatment of symptomatic patients with bifurcation coronary lesions. The main objective was to assess the ease of deployment, side-branch access and overall success of the R(trade mark) stent in this group of patients without any major adverse events. METHODS: Between December 1998 and September 2000 the R(trade mark) stent was used as a main stent in 28 consecutive patients with coronary bifurcation lesions, 46% of which had unstable angina. The mean age was 59 +/- 10 and 89% were male. Adjunctive medical therapy included clopidrogel, aspirin and intraprocedure heparin. Abciximab (ReoPro) was given to 9 patients. RESULTS: Successful stent deployment was achieved in all patients. Thirty-four R Stents and 16 other stents were used. Two patients had post-procedure rise in cardiac enzymes. There were no major adverse events at 30 days. LAD/D1 with LAD/diagonal was the target lesion in the majority of patients. Stenting of the side-branch was done in 18 and balloon dilatation in 9 patients. At 3-23 months (mean 11.8) follow-up, repeat angiography was done in 18 patients with restenosis in 4, two of them had repeat PCI and one had coronary artery bypass graft (CABG). CONCLUSION: Coronary bifurcation lesions are not uncommon. Current advances in stent technology offer a safe and effective revascularisation strategy for such complex lesions. The R(trade mark) stent appears to be a suitable device that provides good wall coverage, radial strength, conformability and easy side-branch access.  相似文献   

9.
BACKGROUND: Coronary stents have been used with increasing frequency and in increasingly complex coronary disease. A new 316 LVM stainless steel coronary stent, the R Stent, has been designed to provide maximum flexibility for tracking and high radial strength post-deployment. PURPOSE: To assess the clinical feasibility of the R Stent in a tertiary referral population of patients with coronary heart disease. Specific objectives are to assess the R Stent's deployment success, angiographic and procedural success (<20% residual stenosis and >TIMI 2 flow), safety (absence of complications), and 30-day clinical success (angiographic/procedural success plus no major adverse coronary events). METHODS: Between April and November 1998, stent deployment was attempted in 27 patients with stable (46%) or unstable (54%) angina pectoris who qualified for percutaneous transluminal coronary angioplasty. Eighty per cent of patients had a pre-existing history of myocardial infarction, coronary bypass surgery or percutaneous transluminal coronary angioplasty, and several of the lesions were anatomically complex (totally occluded, n 32; thrombus present, n 32; heavily calcified, n 33; ostial, n 31; >20 mm long, n 39; angulation >45 degrees, n 37). Lesions in aortocoronary saphenous vein grafts were excluded. Adjunctive medical management included intraprocedural aspirin and heparin and post-procedural aspirin and ticlopidine. After deployment, patients were followed up in the hospital and at 30 days post procedure. RESULTS: Stent deployment was achieved in 32 of 33 attempts (26 of 27 patients). There was one deployment failure in a long, calcified ostial and proximal left coronary lesion. In the 26 successful deployments, TIMI 3 flow was achieved. One other patient experienced a painless increase in creatine kinase to 375 (CK-MB of 59) at 12 h without ECG changes. At 30 days, there were no deaths, no myocardial infarctions, no subacute thromboses, no repeat interventions, no bypass surgeries and no bleeding complications. Only the patient with post-procedural CK-MB elevation experience recurrence of CCS class 2 angina within the 30 days. CONCLUSION: The R Stent is a promising new device for the treatment of complex coronary heart disease. A larger, more broadly-based study is warranted.  相似文献   

10.
Subacute stent thrombosis (SAST) is a major thrombotic complication of coronary stenting. Its occurrence has been substantially reduced by thienopyridine treatment. However, information on clinical profile of patients with SAST in clopidogrel era is limited. In order to define the incidence and factors predisposing to stent thrombosis, we analyzed the computerized angiographic database of three interventional cardiology centers. Out of a total number of 5903 percutaneous coronary interventions (PCIs) with stent implantation, we found 10 patients with SAST (0.17%). The indication for PCI was usually an early invasive approach (90%) during an acute coronary syndrome. All patients were treated with an apparently optimal antithrombotic regimen (90% received heparin or LMWH and 70% received IIb/IIIa receptor inhibitors and all given aspirin). In each of the patients, we could identify high-risk angiographic findings. SAST presentation was always clinically significant with definite myocardial infarction in 100% of cases. 80% of cases occurred during the first six days post PCI. Two patients had a recurrent event. Finally, despite earlier reports of atorvastatin-mediated inhibition of clopidogrel activation we did not find any patient with SAST taking both drugs. Thus, patients with stent thrombosis during thienopyridine treatment usually exhibit high-risk angiographic features. Prospective studies should be performed to elucidate drug interactions that may reduce clopidogrel efficacy and contribute to stent thrombosis.  相似文献   

11.
The treatment of coronary bifurcation lesions represents a challenge for the interventional cardiologists due to the lower rate of procedural success and the higher risk of restenosis. The advent of drug-eluting stents (DES) has dramatically reduced restenosis and consequently the request for re-intervention. The aim of the present work is to provide further insight about the effectiveness of DES by means of a computational study that combines virtual stent implantation, fluid dynamics and drug release for different stenting protocols currently used in the treatment of a coronary artery bifurcation. An explicit dynamic finite element model is developed in order to obtain realistic configurations of the implanted devices used to perform fluid dynamics analysis by means of a previously developed finite element method coupling the blood flow and the intramural plasma filtration in rigid arteries. To efficiently model the drug release, a multiscale strategy is adopted, ranging from lumped parameter model accounting for drug release to fully 3-D models for drug transport to the artery. Differences in drug delivery to the artery are evaluated with respect to local drug dosage. This model allowed to compare alternative stenting configurations (namely the Provisional Side Branch, the Culotte and the Inverted Culotte techniques), thus suggesting guidelines in the treatment of coronary bifurcation lesions and addressing clinical issues such as the effectiveness of drug delivery to lesions in the side branch, as well as the influence of incomplete strut apposition and overlapping stents.  相似文献   

12.
This review concisely recapitulates the different existing modes of stent‐mediated gene/drug delivery, their considerable advancement in clinical trials and a rationale for other merging new technologies such as nanotechnology and microRNA‐based therapeutics, in addition to addressing the limitations in each of these perpetual stent platforms. Over the past decade, stent‐mediated gene/drug delivery has materialized as a hopeful alternative for cardiovascular disease and cancer in contrast to routine conventional treatment modalities. Regardless of the phenomenal recent developments achieved by coronary interventions and cancer therapies that employ gene and drug‐eluting stents, practical hurdles still remain a challenge. The present review highlights the limitations that each of the existing stent‐based gene/drug delivery system encompasses and therefore provides a vision for the future with respect to discovering an ideal stent therapeutic platform that would circumvent all the practical hurdles witnessed with the existing technology. Further study of the improvisation of next‐generation drug‐eluting stents has helped to overcome the issue of restenosis to some extent. However, current stent formulations fall short of the anticipated clinically meaningful outcomes and there is an explicit need for more randomized trials aiming to further evaluate stent platforms in favour of enhanced safety and clinical value. Gene‐eluting stents may hold promise in contributing new ideas for stent‐based prevention of in‐stent restenosis through genetic interventions by capitalizing on a wide variety of molecular targets. Therefore, the central consideration directs us toward finding an ideal stent therapeutic platform that would tackle all of the gaps in the existing technology.  相似文献   

13.
Background: Pericardial fat has a higher secretion of inflammatory cytokines than subcutaneous fat. Cytokines released from pericardial fat around coronary arteries may act locally on the adjacent cells. Objective: We examined the relationship between pericardial fat and calcified coronary plaque. Methods and Procedures: Participants in the community‐based Multi‐Ethnic Study of Atherosclerosis (MESA) underwent a computed tomography (CT) scan for the assessment of calcified coronary plaque in 2000/2002. We measured the volume of pericardial fat using these scans in 159 whites and blacks without symptomatic coronary heart disease from Forsyth County, NC, aged 55–74 years. Results: Calcified coronary plaque was observed in 91 participants (57%). After adjusting for height, a 1 s.d. increment in pericardial fat was associated with an increased odds of calcified coronary plaque (odds ratio (95% confidence interval): 1.92 (1.27, 2.90)). With further adjustment of other cardiovascular factors, pericardial fat was still significantly associated with calcified coronary plaque. This relationship did not differ by gender and ethnicity. On the other hand, BMI and height‐adjusted waist circumference were not associated with calcified coronary plaque. Discussion: Pericardial fat is independently associated with calcified coronary plaque.  相似文献   

14.
The introduction of the drug-eluting stent (DES) proved to be an important step forward in reducing the rates of restenosis and target lesion revascularization after percutaneous coronary intervention (PCI). However, the rapid implementation of DES in standard practice and the expansion of the indications for PCI to high-risk patients and complex lesions also introduced a new problem. DES in-stent restenosis (ISR) occurs in 3 ?? 20% of patients, depending on the patient, lesion characteristics and the DES type. The initial commercially available DES used a stainless steel platform coated with a permanent polymer to provide a controlled release of an anti-restenotic drug. The platform, polymer and drug are all targets for improvement. More advanced metallic and fully biodegradable stent platforms are currently under investigation. The permanent polymer coating, a likely contributor to adverse events, is being superseded by biocompatible and bioabsorbable alternatives. New drugs and drug combinations are also a research goal, as interventional cardiologists and the industry strive towards a safer anti-restenotic DES. This paper reviews the benefits, risks, and current status of biodegradable drug-eluting stents.  相似文献   

15.
The current treatment for coronary restenosis following balloon angioplasty involves the use of a mechanical or a drug-eluting stent. Despite the high usage of commercially-available drug-eluting stents in the cardiac field, there are a number of limitations. This review will present the background ofrestenosis, go briefly into the molecular and cellular mechanisms of restenosis, the use of mechanical stents in coronary restenosis, and will provide an overview of the drugs and genes tested to treat restenosis. The primary focus of this article is to present a comprehensive overview on the use of nanoparticulate delivery systems in the treatment of restenosis both in-vitro and in-vivo. Nanocarriers have been tested in a variety of animal models and in human clinical trials with favorable results. Polymer-based nanoparticles, liposomes, and micelles will be discussed, in addition to the findings presented in the field of cardiovascular drug targeting. Nanocarrier-based delivery presents a viable alternative to the current stent based therapies.  相似文献   

16.
Wang Q  Sirois E  Sun W 《Journal of biomechanics》2012,45(11):1965-1971
The objective of this study was to develop a patient-specific computational model to quantify the biomechanical interaction between the transcatheter aortic valve (TAV) stent and the stenotic aortic valve during TAV intervention. Finite element models of a patient-specific stenotic aortic valve were reconstructed from multi-slice computed tomography (MSCT) scans, and TAV stent deployment into the aortic root was simulated. Three initial aortic root geometries of this patient were analyzed: (a) aortic root geometry directly reconstructed from MSCT scans, (b) aortic root geometry at the rapid right ventricle pacing phase, and (c) aortic root geometry with surrounding myocardial tissue. The simulation results demonstrated that stress, strain, and contact forces of the aortic root model directly reconstructed from MSCT scans were significantly lower than those of the model at the rapid ventricular pacing phase. Moreover, the presence of surrounding myocardium slightly increased the mechanical responses. Peak stresses and strains were observed around the calcified regions in the leaflets, suggesting the calcified leaflets helped secure the stent in position. In addition, these elevated stresses induced during TAV stent deployment indicated a possibility of tissue tearing and breakdown of calcium deposits, which might lead to an increased risk of stroke. The potential of paravalvular leak and occlusion of coronary ostia can be evaluated from simulated post-deployment aortic root geometries. The developed computational models could be a valuable tool for pre-operative planning of TAV intervention and facilitate next generation TAV device design.  相似文献   

17.
In-stent restenosis occurs in coronary arteries after implantation of drug-eluting stents with non-uniform restenosis thickness distribution in the artery cross section. Knowledge of the spatio-temporal drug uptake in the arterial wall is useful for investigating restenosis growth but may often be very expensive/difficult to acquire experimentally. In this study, local delivery of a hydrophobic drug from a drug-eluting stent implanted in a coronary artery is mathematically modelled to investigate the drug release and spatio-temporal drug distribution in the arterial wall. The model integrates drug diffusion in the coating and drug diffusion with reversible binding in the arterial wall. The model is solved by the finite volume method for both high and low drug loadings relative to its solubility in the stent coating with varied isotropic–anisotropic vascular drug diffusivities. Drug release profiles in the coating are observed to depend not only on the coating drug diffusivity but also on the properties of the surrounding arterial wall. Time dependencies of the spatially averaged free- and bound-drug levels in the arterial wall on the coating and vascular drug diffusivities are discussed. Anisotropic vascular drug diffusivities result in slightly different average drug levels in the arterial wall but with very different spatial distributions. Higher circumferential vascular diffusivity results in more uniform drug loading in the upper layers and is potentially beneficial in reducing in-stent restenosis. An analytical expression is derived which can be used to determine regions in the arterial with higher free-drug concentration than bound-drug concentration.  相似文献   

18.
Transcatheter Aortic Valves rely on the tissue-stent interaction to ensure that the valve is secured within the aortic root. Aortic stenosis presents with heavily calcified leaflets and it has been proposed that this calcification also acts to secure the valve, but this has never been quantified. In this study, we developed an in vitro calcified aortic root model to quantify the role of calcification on the tissue-stent interaction. The in vitro model incorporated artificial calcifications affixed to the leaflets of porcine aortic heart valves. A self-expanding nitinol braided stent was deployed into non-calcified and artificially calcified porcine aortic roots and imaged by micro computed tomography. Mechanical tests were then conducted to dislodge the stent from the aortic root and it was found that, in the presence of calcification, there was a significant increase in pullout force (8.59 ± 3.68 N vs. 2.84 ± 1.55 N p = 0.045), stent eccentricity (0.05 ± 0.01 vs. 0.02 ± 0.01, p = 0.049), and coefficient of friction between the stent and aortic root (0.36 ± 0.12 vs. 0.09 ± 0.05, p = 0.018), when compared to non-calcified roots. This study quantifies for the first time the impact of calcification on the friction between the aortic tissue and transcatheter aortic valve stent, showing the role of calcification in anchoring the valve stent in the aortic root.  相似文献   

19.
OBJECTIVE: Assessment of safety and efficacy of coronary stent deployment, without balloon predilatation. BACKGROUND: With newer high-performance balloon-premounted stents it has become more common to attempt coronary stent deployment without balloon pre- or postdilatation. METHODS: During 1998 524 coronary angioplasties were performed in the authors' institute, of which 279 resulted in coronary stenting. Of these 101 (36.2%) were stents without balloon predilatation (SWBP). PTCA was performed according to standard technique using mostly 7 F. guiding catheters, and 'rapid exchange' balloons and pre-mounted stents. RESULTS: Seventy-two patients had acute coronary syndromes (41 acute MI or post-MI angina, 28 unstable angina, 10 rescue PTCA after failed thrombolysis). Mean age was 56.4 3 11.1 years, 84.5% were males. Sixty per cent of the lesions were ACC-AHA type B2 or C. Target arteries were LAD 57.6%, LCX 21.2%, RCA 14.1% and SVG 7.1%. Procedure time was 18.2 3 17.3 minutes. Mean heparin dose was 3850 3 1570 units. Twenty-two patients received abciximab prior to stent deployment. Seven stents were not deployed without previous balloon dilatation and were retrieved safely via the guiding catheters and deployed after balloon dilatation. There was no stent embolization, ectopic suboptimal or partial stent deployment. Immediate angiographic success was obtained in 95 patients (94.1%). Minimal lumin diameter (MLD) increased from 0.27 3 0.15 to 3.23 3 2.1 mm. There were two in-hospital deaths (1.9%) due to cardiogenic shock. An intra-aortic balloon pump was required in eight patients. Two patients (1.9%) experienced subacute stent thrombosis. CONCLUSION: SWBP in selective groups of patients and lesions is feasible and safe. Larger randomized comparative trials are needed to assess the benefits and cost saving of this approach.  相似文献   

20.
BACKGROUND: Over the past 10 years stents have been used more frequently for the treatment of de novo coronary artery stenosis. Initally these devices were used primarily in coronary arteries with diameters ranging from 3.0 to 4.0 mm. Traditionally, coronary arteries less than 3.0 mm in diameter were treated with only balloon angioplasty, due to the unavailablity of flexible, low profile, small diameter stents. In the past three years, many stents have been designed to be implanted in small coronary arteries. OBJECTIVE: The objective of this study was to evaluate the safety and feasiblity of the R Stent in patients with coronary lesions located in coronary arteries with a reference diameter 2.5-3.0 mm. METHODS AND RESULTS: Between November 1998 and September 1999, 32 patients with stable (37%) and unstable (63%) angina treated with the R Stent were included in this study. The treated lesions were in the right coronary artery (RCA) (n = 13), left cirumflex coronary artery (LCX) (n = 10), and left anterior descending coronary artery (LAD) (n = 9). Of these lesions thirteen were anatomically complex. Stent deployment was successful in 97% with one crossing failure in a patient with a vessel tortuosity of greater than 75 degrees of the circumflex artery. No post-procedual major adverse cardiac and cerebrovascular event (MACCE) occurred within 30 days of stent implantation. After the procedure, patients were scheduled for a two-week telephone follow-up and a one-month clinical evaluation. At 30 days, only one patient (3%) experienced the recurrence of angina Canadian cardiovascular society classification ((CCS) Class 2). All other patients were event and angina free. CONCLUSION: This first clinical experience in patients with small vessel disease shows that the use of the R stent is safe and feasible with low rates of acute stent thrombosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号